Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39111771

RESUMO

Photothermal therapy (PTT) is a method for eradicating tumor tissues through the use of photothermal materials and photosensitizing agents that absorb light energy from laser sources and convert it into heat, which selectively targets and destroys cancer cells while sparing healthy tissue. MXenes have been intensively investigated as photosensitizing agents for PTT. However, achieving the selectivity of MXenes to the tumor cells remains a challenge. Specific antibodies (Ab) against tumor antigens can achieve homing of the photosensitizing agents toward tumor cells, but their immobilization on MXene received little attention. Here, we offer a strategy for the selective ablation of melanoma cells using MXene-polydopamine-antiCEACAM1 Ab complexes. We coated Ti3C2Tx MXene with polydopamine (PDA), a natural compound that attaches Ab to the MXene surface, followed by conjugation with an anti-CEACAM1 Ab. Our experiments confirm the biocompatibility of the Ti3C2Tx-PDA and Ti3C2Tx-PDA-antiCEACAM1 Ab complexes across various cell types. We also established a protocol for the selective ablation of CEACAM1-positive melanoma cells using near-infrared irradiation. The obtained complexes exhibit high selectivity and efficiency in targeting and eliminating CEACAM1-positive melanoma cells while sparing CEACAM1-negative cells. These results demonstrate the potential of MXene-PDA-Ab complexes for cancer therapy. They underline the critical role of targeted therapies in oncology, offering a promising avenue for the precise and safe treatment of melanoma and possibly other cancers characterized by specific biomarkers. Future research will aim to refine these complexes for clinical use, paving the way for new strategies for cancer treatment.

2.
Sci Total Environ ; 950: 175190, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094638

RESUMO

Lead ions are especially harmful to human health, causing significant developmental and behavioral abnormalities even at small concentrations. In real-life samples, lead ions are present in mixtures with other metal ions, creating a challenge to detect it selectively at low quantities. To address these challenges, we prepared an electrochemical sensor based on delaminated Ti3C2Tx MXene, which can selectively detect low concentrations of Pb2+ in a solution containing other common metal ions. Cyclic voltammetry was applied as an electrochemical detection method. The proposed reaction mechanism involves a reversible transition between Pb2+ ions and PbO at the MXene-based layer. The sensitivity of the sensor towards Pb2+ ions and a limit of detection were determined. The sensor, as prepared, had a linear response range within 0.15-1.0 µM, with a sensitivity of 26.7 µA/µM and LOD value of 48.7 nM, which meets the requirements set by the World Health Organization.

3.
ACS Nano ; 18(20): 13184-13195, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38710100

RESUMO

Extending applications of Ti3C2Tx MXene in nanocomposites and across fields of electronics, energy storage, energy conversion, and sensor technologies necessitates simple and efficient analytical methods. Raman spectroscopy is a critical tool for assessing MXene composites; however, high laser powers and temperatures can lead to the materials' deterioration during the analysis. Therefore, an in-depth understanding of MXene photothermal degradation and changes in its oxidation state is required, but no systematic studies have been reported. The primary aim of this study was to investigate the degradation of the MXene lattice through Raman spectroscopic analysis. Distinct spectral markers were related to structural alterations within the Ti3C2Tx material after subjecting it to thermal- and laser-induced degradation. During the degradation processes, spectral markers were revealed for several specific steps: a decrease in the number of interlayer water molecules, a decrease in the number of -OH groups, formation of C-C bonds, oxidation of the lattice, and formation of TiO2 nanoparticles (first anatase, followed by rutile). By tracking of position shifts and intensity changes for Ti3C2Tx, the spectral markers that signify the initiation of each step were found. This spectroscopic approach enhances our understanding of the degradation pathways of MXene, and facilitating enhanced and dependable integration of these materials into devices for diverse applications, from energy storage to sensors.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36892008

RESUMO

New conductive materials for tissue engineering are needed for the development of regenerative strategies for nervous, muscular, and heart tissues. Polycaprolactone (PCL) is used to obtain biocompatible and biodegradable nanofiber scaffolds by electrospinning. MXenes, a large class of biocompatible 2D nanomaterials, can make polymer scaffolds conductive and hydrophilic. However, an understanding of how their physical properties affect potential biomedical applications is still lacking. We immobilized Ti3C2Tx MXene in several layers on the electrospun PCL membranes and used positron annihilation analysis combined with other techniques to elucidate the defect structure and porosity of nanofiber scaffolds. The polymer base was characterized by the presence of nanopores. The MXene surface layers had abundant vacancies at temperatures of 305-355 K, and a voltage resonance at 8 × 104 Hz with the relaxation time of 6.5 × 106 s was found in the 20-355 K temperature interval. The appearance of a long-lived component of the positron lifetime was observed, which was dependent on the annealing temperature. The study of conductivity of the composite scaffolds in a wide temperature range, including its inductive and capacity components, showed the possibility of the use of MXene-coated PCL membranes as conductive biomaterials. The electronic structure of MXene and the defects formed in its layers were correlated with the biological properties of the scaffolds in vitro and in bacterial adhesion tests. Double and triple MXene coatings formed an appropriate environment for cell attachment and proliferation with mild antibacterial effects. A combination of structural, chemical, electrical, and biological properties of the PCL-MXene composite demonstrated its advantage over the existing conductive scaffolds for tissue engineering.

5.
ACS Appl Mater Interfaces ; 14(25): 28683-28696, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35704779

RESUMO

Innovative therapies are urgently needed to combat cancer. Thermal ablation of tumor cells is a promising minimally invasive treatment option. Infrared light can penetrate human tissues and reach superficial malignancies. MXenes are a class of 2D materials that consist of carbides/nitrides of transition metals. The transverse surface plasmons of MXenes allow for efficient light absorption and light-to-heat conversion, making MXenes promising agents for photothermal therapy (PTT). To date, near-infrared (NIR) light lasers have been used in PTT studies explicitly in a continuous mode. We hypothesized that pulsed NIR lasers have certain advantages for the development of tailored PTT treatment targeting tumor cells. The pulsed lasers offer a wide range of controllable parameters, such as power density, duration of pulses, pulse frequency, and so on. Consequently, they can lower the total energy applied and enable the ablation of tumor cells while sparing adjacent healthy tissues. We show for the first time that a pulsed 1064 nm laser could be employed for selective ablation of cells loaded with Ti3C2Tx MXene. We demonstrate both low toxicity and good biocompatibility of this MXene in vitro, as well as a favorable safety profile based on the experiments in vivo. Furthermore, we analyze the interaction of MXene with cells in several cell lines and discuss possible artifacts of commonly used cellular metabolic assays in experiments with MXenes. Overall, these studies provide a basis for the development of efficient and safe protocols for minimally invasive therapies for certain tumors.


Assuntos
Hipertermia Induzida , Linhagem Celular Tumoral , Humanos , Hipertermia Induzida/métodos , Raios Infravermelhos , Lasers , Terapia Fototérmica
6.
Biosens Bioelectron ; 207: 114141, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35298947

RESUMO

Continuous painless glucose monitoring is the greatest desire of more than 422 million diabetics worldwide. Therefore, new non-invasive and convenient approaches to glucose monitoring are more in demand than other tests for microanalytical diagnostic tools. Besides, blood glucose detection can be replaced by continuous glucose monitoring of other human biological fluids (e.g. sweat) collected non-invasively. In this study, a skin-attachable and stretchable electrochemical enzymatic sensor based on ZnO tetrapods (TPs) and a new class of 2D materials - transition metal carbides, known as MXene, was developed and their electroanalytical behavior was tailored for continuous detection glucose in sweat. The high specific area of ZnO TPs and superior electrical conductivity of MXene (Ti3C2Tx) nanoflakes enabled to produce enzymatic electrochemical glucose biosensor with enhanced sensitivity in sweat sample (29 µA mM-1 cm-2), low limit of detection (LOD ≈ 17 µM), broad linear detection range (LDR = 0.05-0.7 mM) that satisfices glucose detection application in human sweat, and advanced mechanical stability (up to 30% stretching) of the template. The developed skin-attachable stretchable electrochemical electrodes allowed to monitor the level of glucose in sweat while sugar uptake and during physical activity. Continuous in vivo monitoring of glucose in sweat obtained during 60 min correlated well with data collected by a conventional amperometric blood glucometer in vitro mode. Our findings demonstrate the high potential of developed ZnO/MXene skin-attachable stretchable sensors for biomedical applications on a daily basis.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Óxido de Zinco , Glicemia , Automonitorização da Glicemia , Técnicas Eletroquímicas , Eletrodos , Glucose , Humanos , Suor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA