Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Clin Microbiol ; : e0052524, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888304

RESUMO

Candida auris is a multidrug-resistant fungal pathogen with a propensity to colonize humans and persist on environmental surfaces. C. auris invasive fungal disease is being increasingly identified in acute and long-term care settings. We have developed a prototype cartridge-based C. auris surveillance assay (CaurisSurV cartridge; "research use only") that includes integrated sample processing and nucleic acid amplification to detect C. auris from surveillance skin swabs in the GeneXpert instrument and is designed for point-of-care use. The assay limit of detection (LoD) in the skin swab matrix was 10.5 and 14.8 CFU/mL for non-aggregative (AR0388) and aggregative (AR0382) strains of C. auris, respectively. All five known clades of C. auris were detected at 2-3-5× (31.5-52.5 CFU/mL) the LoD. The assay was validated using a total of 85 clinical swab samples banked at two different institutions (University of California Los Angeles, CA and Wadsworth Center, NY). Compared to culture, sensitivity was 96.8% (30/31) and 100% (10/10) in the UCLA and Wadsworth cohorts, respectively, providing a combined sensitivity of 97.5% (40/41), and compared to PCR, the combined sensitivity was 92% (46/50). Specificity was 100% with both clinical (C. auris negative matrix, N = 31) and analytical (non-C. auris strains, N = 32) samples. An additional blinded study with N = 60 samples from Wadsworth Center, NY yielded 97% (29/30) sensitivity and 100% (28/28) specificity. We have developed a completely integrated, sensitive, specific, and 58-min prototype test, which can be used for routine surveillance of C. auris and might help prevent colonization and outbreaks in acute and chronic healthcare settings. IMPORTANCE: This study has the potential to offer a better solution to healthcare providers at hospitals and long-term care facilities in their ongoing efforts for effective and timely control of Candida auris infection and hence quicker response for any potential future outbreaks.

2.
Sci Rep ; 13(1): 21927, 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081834

RESUMO

The continued emergence of vaccine-resistant SARS-CoV-2 variants of concern (VOC) requires specific identification of each VOC as it arises. Here, we report an expanded version of our previously described sloppy molecular beacon (SMB) melting temperature (Tm) signature-based assay for VOCs, now modified to include detection of Delta (B.1.617.2) and Omicron (B.1.1.529) sub-variants. The SMB-VOC assay targets the signature codons 501, 484 and 452 in the SARS-CoV-2 spike protein which we show can specifically detect and differentiate all known VOCs including the Omicron subvariants (BA.1, BA.2, BA.2.12.1, BA.4/BA.5). The limit of detection (LOD) of the assay was 20, 22 and 36 genomic equivalents (GE) per reaction with the Delta, Omicron BA.1 and BA.2 respectively. Clinical validation of the 3-codon assay in the LC480 instrument showed the assay detected 94% (81/86) of the specimens as WT or VOCs and 6% (5/86) of the tests producing indeterminate results compared to sequencing. Sanger sequencing also failed for four samples. None of the specimens were incorrectly identified as WT or as a different VOC by our assay. Thus, excluding specimens with indeterminant results, the assay was 100% sensitive and 100% specific compared to Sanger sequencing for variant identification. This new assay concept can be easily expanded to add newer variants and can serve as a robust diagnostic tool for selecting appropriate monoclonal antibody therapy and rapid VOC surveillance.


Assuntos
COVID-19 , Magnoliopsida , Humanos , COVID-19/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética , Temperatura , Teste para COVID-19
3.
PLoS One ; 18(3): e0282708, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36928472

RESUMO

Saliva has been a COVID-19 diagnostic specimen of interest due to its simple collection, scalability, and yield. Yet COVID-19 testing and estimates of the infectious period remain largely based on nasopharyngeal and nasal swabs. We sought to evaluate whether saliva testing captured prolonged presence of SARS-CoV-2 and potential infectiousness later in the disease course. We conducted an observational study of symptomatic COVID-19 patients at University Hospital in Newark, NJ. Paired saliva and nasal specimens from 96 patients were analyzed, including longitudinal analysis of paired observations from 28 of these patients who had multiple time-points. Saliva detected significantly more cases of COVID-19 beyond 5 days (86.1% [99/115] saliva vs 48.7% [56/115] nasal, p-value < 0.001), 9 days (79.4% [50/63] saliva vs 36.5% [23/63] nasal, p-value < 0.001) and 14 days (71.4% [20/28] saliva vs 32.1% [9/28] nasal, p-value = 0.010) of symptoms. Additionally, saliva yielded lower cycle thresholds across all time periods, indicative of higher viral loads in saliva. In the longitudinal analysis, a log-rank analysis indicated that the survival curve for saliva was significantly different from the curve for nasal swabs (p<0.001) with a median survival time for saliva of 18 days compared to 13 days for nasal swabs. We additionally performed saliva viral cultures among a similar COVID-19 patient cohort and noted patients with positive saliva viral cultures between 7 to 28 days of symptoms. Findings from this study suggest that SARS-CoV-2 RNA persists longer and in higher abundance in saliva compared to nasal swabs, with potential of prolonged propagating virus. Testing saliva may thus increase yield for detecting potentially infectious virus even beyond the first five days of symptomatic COVID-19.


Assuntos
COVID-19 , Doenças Transmissíveis , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , RNA Viral/genética , Manejo de Espécimes , Nasofaringe
4.
BMC Infect Dis ; 22(1): 149, 2022 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-35152885

RESUMO

BACKGROUND: COVID-19 is a multi-system infection with emerging evidence-based antiviral and anti-inflammatory therapies to improve disease prognosis. However, a subset of patients with COVID-19 signs and symptoms have repeatedly negative RT-PCR tests, leading to treatment hesitancy. We used comparative serology early in the COVID-19 pandemic when background seroprevalence was low to estimate the likelihood of COVID-19 infection among RT-PCR negative patients with clinical signs and/or symptoms compatible with COVID-19. METHODS: Between April and October 2020, we conducted serologic testing of patients with (i) signs and symptoms of COVID-19 who were repeatedly negative by RT-PCR ('Probables'; N = 20), (ii) signs and symptoms of COVID-19 but with a potential alternative diagnosis ('Suspects'; N = 15), (iii) no signs and symptoms of COVID-19 ('Non-suspects'; N = 43), (iv) RT-PCR confirmed COVID-19 patients (N = 40), and (v) pre-pandemic samples (N = 55). RESULTS: Probables had similar seropositivity and levels of IgG and IgM antibodies as propensity-score matched RT-PCR confirmed COVID-19 patients (60.0% vs 80.0% for IgG, p-value = 0.13; 50.0% vs 72.5% for IgM, p-value = 0.10), but multi-fold higher seropositivity rates than Suspects and matched Non-suspects (60.0% vs 13.3% and 11.6% for IgG; 50.0% vs 0% and 4.7% for IgM respectively; p-values < 0.01). However, Probables were half as likely to receive COVID-19 treatment than the RT-PCR confirmed COVID-19 patients with similar disease severity. CONCLUSIONS: Findings from this study indicate a high likelihood of acute COVID-19 among RT-PCR negative with typical signs/symptoms, but a common omission of COVID-19 therapies among these patients. Clinically diagnosed COVID-19, independent of RT-PCR positivity, thus has a potential vital role in guiding treatment decisions.


Assuntos
Tratamento Farmacológico da COVID-19 , Anticorpos Antivirais , Humanos , Imunoglobulina M , Pandemias , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Estudos Soroepidemiológicos
5.
J Med Microbiol ; 70(9)2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34486972

RESUMO

Introduction. Non-invasive sample collection and viral sterilizing buffers have independently enabled workflows for more widespread COVID-19 testing by reverse-transcriptase polymerase chain reaction (RT-PCR).Gap statement. The combined use of sterilizing buffers across non-invasive sample types to optimize sensitive, accessible, and biosafe sampling methods has not been directly and systematically compared.Aim. We aimed to evaluate diagnostic yield across different non-invasive samples with standard viral transport media (VTM) versus a sterilizing buffer eNAT- (Copan diagnostics Murrieta, CA) in a point-of-care diagnostic assay system.Methods. We prospectively collected 84 sets of nasal swabs, oral swabs, and saliva, from 52 COVID-19 RT-PCR-confirmed patients, and nasopharyngeal (NP) swabs from 37 patients. Nasal swabs, oral swabs, and saliva were placed in either VTM or eNAT, prior to testing with the Xpert Xpress SARS-CoV-2 (Xpert). The sensitivity of each sampling strategy was compared using a composite positive standard.Results. Swab specimens collected in eNAT showed an overall superior sensitivity compared to swabs in VTM (70 % vs 57 %, P=0.0022). Direct saliva 90.5 %, (95 % CI: 82 %, 95 %), followed by NP swabs in VTM and saliva in eNAT, was significantly more sensitive than nasal swabs in VTM (50 %, P<0.001) or eNAT (67.8 %, P=0.0012) and oral swabs in VTM (50 %, P<0.0001) or eNAT (58 %, P<0.0001). Saliva and use of eNAT buffer each increased detection of SARS-CoV-2 with the Xpert; however, no single sample matrix identified all positive cases.Conclusion. Saliva and eNAT sterilizing buffer can enhance safe and sensitive detection of COVID-19 using point-of-care GeneXpert instruments.


Assuntos
Teste de Ácido Nucleico para COVID-19 , Manejo de Espécimes/métodos , Adulto , Idoso , COVID-19/diagnóstico , Contenção de Riscos Biológicos , Meios de Cultura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca/virologia , Nasofaringe/virologia , Nariz/virologia , Testes Imediatos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Saliva/virologia , Sensibilidade e Especificidade , Manejo de Espécimes/normas
6.
J Clin Microbiol ; 59(10): e0084521, 2021 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-34288729

RESUMO

The increased transmission of SARS-CoV-2 variants of concern (VOC), which originated in the United Kingdom (B.1.1.7/alpha), South Africa (B1.351/beta), Brazil (P.1/gamma), the United States (B.1.427/429 or epsilon), and India (B.1.617.2/delta), requires a vigorous public health response, including real-time strain surveillance on a global scale. Although genome sequencing is the gold standard for identifying these VOCs, it is time-consuming and expensive. Here, we describe a simple, rapid, and high-throughput reverse transcriptase PCR (RT-PCR) melting-temperature (Tm) screening assay that identifies the first three major VOCs. RT-PCR primers and four sloppy molecular beacon (SMB) probes were designed to amplify and detect the SARS-CoV-2 N501Y (A23063T) and E484K (G23012A) mutations and their corresponding wild-type sequences. After RT-PCR, the VOCs were identified by a characteristic Tm of each SMB. Assay optimization and testing was performed with RNA from SARS-CoV-2 USA WA1/2020 (wild type [WT]), B.1.1.7, and B.1.351 variant strains. The assay was then validated using clinical samples. The limit of detection for both the WT and variants was 4 and 10 genomic copies/reaction for the 501- and 484-codon assays, respectively. The assay was 100% sensitive and 100% specific for identifying the N501Y and E484K mutations in cultured virus and in clinical samples, as confirmed by Sanger sequencing. We have developed an RT-PCR melt screening test for the major VOCs that can be used to rapidly screen large numbers of patient samples, providing an early warning for the emergence of these variants and a simple way to track their spread.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Temperatura
7.
PLoS One ; 16(6): e0252687, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34115762

RESUMO

BACKGROUND: Upper respiratory samples used to test for SARS-CoV-2 virus may be infectious and present a hazard during transport and testing. A buffer with the ability to inactivate SARS-CoV-2 at the time of sample collection could simplify and expand testing for COVID-19 to non-conventional settings. METHODS: We evaluated a guanidium thiocyanate-based buffer, eNAT™ (Copan) as a possible transport and inactivation medium for downstream Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR) testing to detect SARS-CoV-2. Inactivation of SARS-CoV-2 USA-WA1/2020 in eNAT and in diluted saliva was studied at different incubation times. The stability of viral RNA in eNAT was also evaluated for up to 7 days at room temperature (28°C), refrigerated conditions (4°C) and at 35°C. RESULTS: SARS-COV-2 virus spiked directly in eNAT could be inactivated at >5.6 log10 PFU/ml within a minute of incubation. When saliva was diluted 1:1 in eNAT, no cytopathic effect (CPE) on VeroE6 cells was observed, although SARS-CoV-2 RNA could be detected even after 30 min incubation and after two cell culture passages. A 1:2 (saliva:eNAT) dilution abrogated both CPE and detectable viral RNA after as little as 5 min incubation in eNAT. SARS-CoV-2 RNA from virus spiked at 5X the limit of detection remained positive up to 7 days of incubation in all tested conditions. CONCLUSION: eNAT and similar guanidinium thiocyanate-based media may be of value for transport, stabilization, and processing of clinical samples for RT-PCR based SARS-CoV-2 detection.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Guanidina/farmacologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/genética , Saliva/efeitos dos fármacos , Saliva/virologia , Manejo de Espécimes/métodos , Inativação de Vírus/efeitos dos fármacos , Animais , COVID-19/virologia , Chlorocebus aethiops , Meios de Cultura , Voluntários Saudáveis , Humanos , RNA Viral/genética , Células Vero
8.
medRxiv ; 2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33758892

RESUMO

BACKGROUND: The increased transmission of SARS-CoV-2 variants of concern (VOC) which originated in the United Kingdom (B.1.1.7), South Africa (B1.351), Brazil (P.1) and in United States (B.1.427/429) requires a vigorous public health response, including real time strain surveillance on a global scale. Although genome sequencing is the gold standard for identifying these VOCs, it is time consuming and expensive. Here, we describe a simple, rapid and high-throughput reverse-transcriptase PCR (RT-PCR) melting temperature (Tm) screening assay that identifies these three major VOCs. METHODS: RT-PCR primers and four sloppy molecular beacon (SMB) probes were designed to amplify and detect the SARS-CoV-2 N501Y (A23063T) and E484K (G23012A) mutations and their corresponding wild type sequences. After RT-PCR, the VOCs were identified by a characteristic Tm of each SMB. Assay optimization and testing was performed with RNA from SARS-CoV-2 USA WA1/2020 (WT), a B.1.17 and a B.1.351 variant strains. The assay was then validated using clinical samples. RESULTS: The limit of detection (LOD) for both the WT and variants was 4 and 10 genomic copies/reaction for the 501 and 484 codon assays, respectively. The assay was 100% sensitive and 100% specific for identifying the N501Y and E484K mutations in cultured virus and in clinical samples as confirmed by Sanger sequencing. CONCLUSION: We have developed an RT-PCR melt screening test for the three major VOCs which can be used to rapidly screen large numbers of patient samples providing an early warning for the emergence of these variants and a simple way to track their spread.

9.
medRxiv ; 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33688680

RESUMO

Sensitive, accessible, and biosafe sampling methods for COVID-19 reverse-transcriptase polymerase chain reaction (RT-PCR) assays are needed for frequent and widespread testing. We systematically evaluated diagnostic yield across different sample collection and transport workflows, including the incorporation of a viral inactivation buffer. We prospectively collected nasal swabs, oral swabs, and saliva, from 52 COVID-19 RT-PCR-confirmed patients, and nasopharyngeal (NP) swabs from 37 patients. Nasal and oral swabs were placed in both viral transport media (VTM) and eNAT™, a sterilizing transport buffer, prior to testing with the Xpert Xpress SARS-CoV-2 (Xpert) test. The sensitivity of each sampling strategy was compared using a composite positive standard. Overall, swab specimens collected in eNAT showed superior sensitivity compared to swabs in VTM (70% vs 57%, P=0.0022). Direct saliva 90.5%, (95% CI: 82%, 95%), followed by NP swabs in VTM and saliva in eNAT, was significantly more sensitive than nasal swabs in VTM (50%, P<0.001) or eNAT (67.8%, P=0.0012) and oral swabs in VTM (50%, P<0.0001) or eNAT (56%, P<0.0001). Saliva and use of eNAT buffer each increased detection of SARS-CoV-2 with the Xpert test; however, no single sample matrix identified all positive cases.

10.
medRxiv ; 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33501462

RESUMO

BACKGROUND: Upper respiratory samples used to test for SARS-CoV-2 virus may be infectious and present a hazard during transport and testing. A buffer with the ability to inactivate SARS-CoV-2 at the time of sample collection could simplify and expand testing for COVID-19 to non-conventional settings. METHODS: We evaluated a guanidium thiocyanate-based buffer, eNAT™ (Copan) as a possible transport and inactivation medium for downstream RT-PCR testing to detect SARS-CoV-2. Inactivation of SARS-CoV-2 USA-WA1/2020 in eNAT and in diluted saliva was studied at different incubation times. The stability of viral RNA in eNAT was also evaluated for up to 7 days at room temperature (28°C), refrigerated conditions (4°C) and at 35°C. RESULTS: SARS-COV-2 virus spiked directly in eNAT could be inactivated at >5.6 log 10 PFU/ml within a minute of incubation. When saliva was diluted 1:1 in eNAT, no cytopathic effect (CPE) on vero-E6 cell lines was observed, although SARS-CoV-2 RNA could be detected even after 30 min incubation and after two cell culture passages. A 1:2 (saliva:eNAT) dilution abrogated both CPE and detectable viral RNA after as little as 5 min incubation in eNAT. SARS-CoV-2 RNA from virus spiked at 5X the limit of detection remained positive up to 7 days of incubation in all tested conditions. CONCLUSION: eNAT and similar guanidinium thiocyanate-based media may be of value for transport, preservation, and processing of clinical samples for RT-PCR based SARS-CoV-2 detection.

11.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32366669

RESUMO

Nucleic acid amplification tests (NAATs) are the primary means of identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and isolation resources and allow rapid therapeutic interventions. We evaluated the analytical and clinical performance characteristics of the Xpert Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2; other infectious coronavirus species, including SARS-CoV; and 85 nasopharyngeal swab specimens positive for other respiratory viruses, including endemic human coronaviruses (hCoVs). Clinical performance was assessed using 483 remnant upper- and lower-respiratory-tract specimens previously analyzed by standard-of-care (SOC) NAATs. The limit of detection of the Xpert test was 0.01 PFU/ml. Other hCoVs, including Middle East respiratory syndrome coronavirus, were not detected by the Xpert test. SARS-CoV, a closely related species in the subgenus Sarbecovirus, was detected by a broad-range target (E) but was distinguished from SARS-CoV-2 (SARS-CoV-2-specific N2 target). Compared to SOC NAATs, the positive agreement of the Xpert test was 219/220 (99.5%), and the negative agreement was 250/261 (95.8%). A third tie-breaker NAAT resolved all but three of the discordant results in favor the Xpert test. The Xpert test provided sensitive and accurate detection of SARS-CoV-2 in a variety of upper- and lower-respiratory-tract specimens. The high sensitivity and short time to results of approximately 45 min may impact patient management.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação Laboratorial/métodos , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Criança , Pré-Escolar , Infecções por Coronavirus/virologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2 , Sensibilidade e Especificidade , Adulto Jovem
12.
J Clin Microbiol ; 57(5)2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30842226

RESUMO

Francisella tularensis, Bacillus anthracis, and Yersinia pestis are tier 1 select agents with the potential to rapidly cause severe disease. Rapid detection of these bacteria from patient samples at the point of care could contribute to improved clinical outcomes in the event of a bioterrorism attack. A multiplex nested PCR assay for detection of F. tularensis, B. anthracis, and Y. pestis directly from patient blood samples was developed using the GeneXpert system. The multiplex GeneXpert cartridge-based assay includes all necessary sample processing and amplification reagents. Blood samples spiked with different numbers of CFU were used to measure the analytical limit of detection (LOD) and dynamic range. Sensitivity was determined by testing spiked blood samples and negative-control blood in a blind manner. Specificity was determined by testing against nontarget pathogens and blood samples from clinical patients. The assay LOD was 8.5 CFU/ml for F. tularensis, 10 CFU/ml for B. anthracis, and 4.5 CFU/ml for Y. pestis The sensitivity was 100% at the LOD for all three select agent bacteria in spiked patient blood samples. The assay specificity was 100% when it was tested against both nontarget pathogens and clinical patient blood samples. The total assay time was approximately 100 min. This automated assay, which is suitable for use at the point of care, identifies three select agents directly in blood without the need for enrichment with a high sensitivity within 100 min. This assay may enable rapid detection and treatment of patients infected with the target organisms in the event of a bioterrorism attack.


Assuntos
Bacillus anthracis/isolamento & purificação , Sangue/microbiologia , Francisella tularensis/isolamento & purificação , Reação em Cadeia da Polimerase Multiplex , Yersinia pestis/isolamento & purificação , Antraz/sangue , Antraz/diagnóstico , Ensaios de Triagem em Larga Escala , Humanos , Limite de Detecção , Peste/sangue , Peste/diagnóstico , Sensibilidade e Especificidade , Tularemia/sangue , Tularemia/diagnóstico
13.
J Clin Microbiol ; 56(9)2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29997199

RESUMO

The microbiological diagnosis of tuberculosis (TB) in children is challenging, as it relies on the collection of relatively invasive specimens by trained health care workers, which is not feasible in many settings. Mycobacterium tuberculosis is detectable from the stools of children using molecular methods, but processing stool specimens is resource intensive. We evaluated a novel, simple, centrifugation-free processing method for stool specimens for use on the Xpert MTB/RIF assay (Xpert), using two different stool masses: 0.6 g and a swab sample. Two hundred eighty children (median age, 15.5 months; 35 [12.5%] HIV infected) with suspected intrathoracic TB were enrolled from two sites in South Africa. Compared to a single Xpert test on respiratory specimens, the sensitivity of Xpert on stools using the 0.6-g and swab samples was 44.4% (95% confidence interval [CI], 13.7 to 78.8%) for both methods, with a specificity of >99%. The combined sensitivities of two stool tests versus the first respiratory Xpert were 70.0% (95% CI, 34.8 to 93.3) and 50.0% (95% CI, 18.7 to 81.3) for the 0.6-g and swab sample, respectively. Retesting stool specimens with nondeterminate Xpert results improved nondeterminate rates from 9.3% to 3.9% and from 8.6% to 4.3% for 0.6-g and swab samples, respectively. Overall, stool Xpert detected 14/94 (14.9%) children who initiated antituberculosis treatment, while respiratory specimens detected 23/94 (24.5%). This stool processing method is well suited for settings with low capacity for respiratory specimen collection. However, the overall sensitivity to detect confirmed and clinical TB was lower than that of respiratory specimens. More sensitive rapid molecular assays are needed to improve the utility of stools for the diagnosis of intrathoracic TB in children from resource-limited settings.


Assuntos
Fezes/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/genética , Tuberculose/diagnóstico , Tuberculose/microbiologia , Pré-Escolar , Feminino , Infecções por HIV/complicações , Humanos , Lactente , Masculino , Mycobacterium tuberculosis/isolamento & purificação , Nasofaringe/microbiologia , Sensibilidade e Especificidade , África do Sul , Manejo de Espécimes , Tuberculose Pulmonar/diagnóstico
14.
mBio ; 8(4)2017 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-28851844

RESUMO

The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection.IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R.


Assuntos
Antibióticos Antituberculose/farmacologia , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Testes Imediatos , Rifampina/farmacologia , Tuberculose/diagnóstico , Proteínas de Bactérias/genética , RNA Polimerases Dirigidas por DNA/genética , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Mutação , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Escarro/microbiologia , Tuberculose/microbiologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia
15.
J Clin Microbiol ; 55(10): 2964-2971, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28747367

RESUMO

Bacillus anthracis is a tier 1 select agent with the potential to quickly cause severe disease. Rapid identification of this pathogen may accelerate treatment and reduce mortality in the event of a bioterrorism attack. We developed a rapid and sensitive assay to detect B. anthracis bacteremia using a system that is suitable for point-of-care testing. A filter-based cartridge that included both sample processing and PCR amplification functions was loaded with all reagents needed for sample processing and multiplex nested PCR. The assay limit of detection (LOD) and dynamic range were determined by spiking B. anthracis DNA into individual PCR mixtures and B. anthracis CFU into human blood. One-milliliter blood samples were added to the filter-based detection cartridge and tested for B. anthracis on a GeneXpert instrument. Assay specificity was determined by testing blood spiked with non-anthrax bacterial isolates or by testing blood samples drawn from patients with concurrent non-B. anthracis bacteremia or nonbacteremic controls. The assay LODs were 5 genome equivalents per reaction and 10 CFU/ml blood for both the B. anthracis Sterne and V1B strains. There was a 6-log10 dynamic range. Assay specificity was 100% for tests of non-B. anthracis bacterial isolates and patient blood samples. Assay time was less than 90 min. This automated system suitable for point-of-care detection rapidly identifies B. anthracis directly from blood with high sensitivity. This assay might lead to early detection and more rapid therapy in the event of a bioterrorism attack.


Assuntos
Antraz/diagnóstico , Bacillus anthracis/genética , Bacteriemia/diagnóstico , DNA Bacteriano/sangue , Testes Imediatos , Bacillus anthracis/isolamento & purificação , Bacteriemia/microbiologia , DNA Bacteriano/genética , Sistemas Inteligentes , Genoma Bacteriano/genética , Humanos , Limite de Detecção
16.
J Clin Microbiol ; 55(1): 291-301, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27847371

RESUMO

Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection.


Assuntos
Automação Laboratorial/métodos , Técnicas Bacteriológicas/métodos , Sangue/microbiologia , Francisella tularensis/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Tularemia/diagnóstico , Animais , Francisella tularensis/genética , Humanos , Macaca , Sensibilidade e Especificidade
17.
PLoS One ; 11(3): e0151980, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27007974

RESUMO

BACKGROUND: Tuberculosis (TB) is difficult to diagnose in children using molecular tests, because children have difficulty providing respiratory samples. Stool could replace sputum for diagnostic TB testing if adequate sample processing techniques were available. METHODS: We developed a rapid method to process large volumes of stool for downstream testing by the Xpert MTB/RIF (Xpert) TB-detection assay. The method was tested and optimized on stool samples spiked with known numbers of M. tuberculosis colony forming units (CFU), and stools from M. tuberculosis-infected cynomolgus macaques (Macaca fascicularis). Performance was scored on number of positive Xpert tests, the cycle thresholds (Cts) of the Xpert sample-processing control (SPC), and the Cts of the M. tuberculosis-specific rpoB probes. The method was then validated on 20 confirmed TB cases and 20 controls in Durban, South Africa. RESULTS: The assay's analytical limit of detection was 1,000 CFU/g of stool. As much as one gram of spiked stool could be tested without showing increased PCR inhibition. In analytical spiking experiments using human stool, 1g samples provided the best sensitivity compared to smaller amounts of sample. However, in Macaques with TB, 0.6g stool samples performed better than either 0.2g or 1.2g samples. Testing the stool of pediatric TB suspects and controls suggested an assay sensitivity of 85% (95% CI 0.6-0.9) and 84% (95% CI 0.6-0.96) for 0.6g and 1.2g stool samples, respectively, and a specificity of 100% (95% CI 0.77-1) and 94% (95% CI 0.7-0.99), respectively. CONCLUSION: This novel approach may permit simple and rapid detection of TB using pediatric stool samples.


Assuntos
Fezes/microbiologia , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Animais , Criança , Humanos , Macaca fascicularis , Macaca mulatta , Sensibilidade e Especificidade , Manejo de Espécimes
18.
J Clin Microbiol ; 54(4): 1051-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26865685

RESUMO

The Epistem Genedrive assay rapidly detects the Mycobacterium tuberculosis omplex from sputum and is currently available for clinical use. However, the analytical and clinical performance of this test has not been fully evaluated. The analytical limit of detection (LOD) of the Genedrive PCR amplification was tested with genomic DNA; the performance of the complete (sample processing plus amplification) system was tested by spiking M. tuberculosismc(2)6030 cells into distilled water andM. tuberculosis-negative sputum. Specificity was tested using common respiratory pathogens and nontuberculosis mycobacteria. A clinical evaluation enrolled adults with suspected pulmonary tuberculosis, obtained three sputum samples from each participant, and compared the accuracy of the Gene drive to that of the Xpert MTB/RIF assay using M. tuberculosiscultures as the reference standard. The Genedrive assay had an LOD of 1 pg/µl (100 genomic DNA copies/reaction). The LODs of the system were 2.5 × 10(4)CFU/ml and 2.5 × 10(5)CFU/ml for cells spiked into water and sputum, respectively. False-positiverpoBprobe signals were observed in 3/32 (9.4%) of the negative controls and also in few samples containing Mycobacterium abscessus,Mycobacterium gordonae, o rMycobacterium thermoresistibile In the clinical study, among 336 analyzed participants, the overall sensitivities for the tuberculosis case detection of Gene drive, Xpert, and smear microscopy were 45.4% (95% confidence interval [CI], 35.2% to 55.8%), 91.8% (95% CI, 84.4% to 96.4%), and 77.3% (95% CI, 67.7% to 85.2%), respectively. The sensitivities of Gene drive and Xpert for the detection of smear-microscopy-negative tuberculosis were 0% (95% CI, 0% to 15.4%) and 68.2% (95% CI, 45.1% to 86.1%), respectively. The Genedrive assay did not meet performance standards recommended by the World Health Organization for a smear microscopy replacement tuberculosis test. Epistem is working on modifications to improve the assay.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Adulto , Estudos Transversais , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Escarro/microbiologia
19.
J Clin Microbiol ; 51(12): 4161-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24108610

RESUMO

The utility of the GeneXpert MTB/RIF (Xpert) assay for detection of Mycobacterium tuberculosis in sputum samples has been extensively studied. However, the performance of the Xpert assay as applied to other readily accessible body fluids such as exhaled breath condensate (EBC), saliva, urine, and blood has not been established. We used the Xpert assay to test EBC, saliva, urine, and blood samples from HIV-negative, smear- and culture-positive pulmonary tuberculosis (TB) patients for the presence of M. tuberculosis. To compare the ability of the assay to perform bacterial load measurements on sputum samples with versus without sample processing, the assay was also performed on paired direct and processed sputum samples from each patient. The Xpert assay detected M. tuberculosis in none of the 26 EBC samples (sensitivity, 0.0%; 95% confidence interval [95% CI], 0.0%, 12.9%), 10 of the 26 saliva samples (sensitivity, 38.5%; 95% CI, 22.4%, 57.5%), 1 of 26 urine samples (sensitivity, 3.8%; 95% CI, 0.7%, 18.9%), and 2 of 24 blood samples (sensitivity, 8.3%; 95% CI, 2.3%, 25.8%). For bacterial load measurements in the different types of sputum samples, the cycle thresholds of the two M. tuberculosis-positive sputum types were well correlated (Spearman correlation of 0.834). This study demonstrates that the Xpert assay should not be routinely used to detect M. tuberculosis in EBC, saliva, urine, or blood samples from HIV-negative patients suspected of having pulmonary tuberculosis. As a test of bacterial load, the assay produced similar results when used to test direct versus processed sputum samples. Sputum remains the optimal sample type for diagnosing pulmonary tuberculosis in HIV-negative patients with the Xpert assay.


Assuntos
Técnicas Bacteriológicas/métodos , Líquidos Corporais/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Adulto , Humanos , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade
20.
J Clin Microbiol ; 51(7): 2311-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23678061

RESUMO

Tuberculosis (TB) remains a leading cause of death among HIV-infected adults, in part because of delayed diagnosis and therefore delayed initiation of treatment. Recently, the Gene-Xpert platform, a rapid, PCR-based diagnostic platform, has been validated for the diagnosis of TB with sputum. We have evaluated the Xpert MTB/RIF assay for the diagnosis of Mycobacterium tuberculosis bacteremia and investigated its impact on clinical outcomes. Consecutive HIV-infected adults with fever and cough presenting to Queen Elizabeth Central Hospital, Blantyre, Malawi, were recruited and followed up for 2 months. At presentation, three sputum samples were examined by smear, culture, and Xpert MTB/RIF assay for the presence of M. tuberculosis and blood was drawn for PCR with Xpert, for mycobacterial culture (Myco/F Lytic), and for aerobic culture. One hundred four patients were recruited, and 44 (43%) were sputum culture positive for M. tuberculosis. Ten were Xpert blood positive, for a sensitivity of 21% and a specificity of 100%. The 2-week mortality rate was significantly higher among patients who were Xpert blood positive than among those who were negative (40% versus 3%; multivariate odds ratio [OR] for death if positive, 44; 95% confidence interval [CI], 3 to 662). This effect persisted on assessment of the mortality rate at 2 months (40% versus 11%; OR, 5.6; 95% CI, 1.3 to 24.6). When screening uncomplicated patients presenting with a productive cough for pulmonary TB, Xpert blood offers no diagnostic advantage over sputum testing. Despite this, Xpert blood positivity is highly predictive of early death and this test rapidly identifies a group of patients in urgent need of initiation of treatment.


Assuntos
Bacteriemia/diagnóstico , Técnicas Bacteriológicas/métodos , Infecções por HIV/complicações , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Adulto , Estudos de Coortes , Feminino , Humanos , Malaui , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA