Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Heart J Case Rep ; 8(5): ytae236, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774774

RESUMO

Background: The acquired communication between the aorta and the pulmonary artery is a rare and potentially life-threatening condition. Its diagnosis is challenging and may require a multimodality imaging approach. Case summary: A 67-year-old Caucasian man, admitted for acute respiratory failure unresponsive to medical therapy and non-invasive ventilation, was diagnosed with an aortopulmonary fistula (APF) complicating a pseudoaneurysm of the aortic root. This condition developed after Bentall cardiac surgery, which entailed the use of a straight Dacron aortic graft coupled with a mechanical prosthesis. A multimodal imaging approach, combining echocardiography and computed tomography angiography, was diagnostic and supported the development of a surgical treatment strategy. The patient underwent successful surgical closure of the APF and correction of the aortic pseudoaneurysm. Discussion: Aortopulmonary fistula can result in rapid clinical deterioration if left untreated. The combination of echocardiography and computed tomography angiography techniques allowed for the diagnosis and surgical correction of the APF.

2.
Eur Heart J Cardiovasc Imaging ; 25(3): 315-324, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-37930715

RESUMO

AIMS: In acute heart failure (AHF), the consequences of impaired left atrial (LA) mechanics are not well understood. We aimed to define the clinical trajectory of LA mechanics by left atrial strain (LAS) analysis. METHODS AND RESULTS: Eighty-five consecutive AHF patients with reduced, mildly reduced, and preserved left ventricular ejection fraction (LVEF) were enrolled in the LAS-AHF trial and underwent LA mechanics analysis by speckle tracking echocardiography. Seventy-seven patients were followed-up (FU) at 6 and 12 months. At hospital admission, discharge, 6 and 12 months post-discharge, LA reservoir function (LAS), LA pump strain, LAVi, LA stiffness, indicators of right ventricular (RV) and left ventricular (LV) function, congestion indexes (B lines, inferior vena cava, X-ray congestion score index), and biomarkers (NT-pro-BNP) were measured. The primary outcome was time to first event of re-hospitalization, worsening HF, or cardiovascular death. From admission to discharge, RV function significantly improved after decongestion, whereas no significant differences were observed in LA dynamics and LV function. In sinus rhythm patients with mild or no mitral regurgitation, decongestion was associated with a significant improvement of LAS and LA pump strain rate during hospitalization. At 12 months, 24 CV events occurred and lack of LAS improvement at 12 months FU emerged as the most powerful predictor followed by NT-pro-BNP. Kaplan-Meier curves showed a better survival for LAS >16%, improvement of LAS > 5%, and an LAS/LAVi ratio >0.25%/mL/m2 compared with lower cut-off values [log-rank: heart rate (HR) 3.5, 95% confidence interval (CI) 1.8-7.3, P = 0.004; log-rank: HR 3.6, 95% CI 2-7.9, P < 0.01; log-rank: HR 3.27, 95% CI 1.4-7.7, P = 0.007]. CONCLUSION: In AHF of any LVEF, LA dynamics is highly predictive of re-hospitalization and cardiovascular outcome and allows to ease risk-stratification, potentially becoming an early reference target for improving long-term outcome.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Humanos , Assistência ao Convalescente , Átrios do Coração , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Alta do Paciente , Prognóstico , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia
3.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
4.
Eur Heart J Suppl ; 25(Suppl C): C189-C199, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125282

RESUMO

Treatments for structural heart diseases (SHD) have been considerably evolved by the widespread of transcatheter approach in the last decades. The progression of transcatheter treatments for SHD was feasible due to the improvement of devices and the advances in imaging techniques. In this setting, the cardiovascular imaging is pivotal not only for the diagnosis but even for the treatment of SHD. With the aim of fulfilling these tasks, a multimodality imaging approach with new imaging tools for pre-procedural planning, intra-procedural guidance, and follow-up of SHD was developed. This review will describe the current state-of-the-art imaging techniques for the most common percutaneous interventions as well as the new imaging tools. The imaging approaches will be addressed describing the use in pre-procedural planning, intra-procedural guidance, and follow-up.

6.
J Clin Med ; 11(4)2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-35207232

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for patients with severe, symptomatic AS, regardless of the transcatheter heart valve (THV) implanted. Prior studies demonstrated a higher device success with lower paravalvular leak (PVL) using the balloon-expandable (BE) Sapien/XT THV vs. a self-expanding (SE) THV. However, few data are available on the performance of a novel BE THV. PURPOSE: to compare early clinical performance and safety of the newly available BE Myval THV (Myval, Meril Life Sciences Pvt. Ltd., India) vs. the commonly used SE (Evolut R, Medtronic) THV. METHODS:  A single-center, retrospective cohort analysis was performed with 166 consecutive patients undergoing TAVR from March 2019 to March 2021 for severe symptomatic AS treated with either the novel BE Myval or the SE Evolut R (ER) bioprosthesis. The primary endpoint was device success at day 30 according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included 30-day all-cause mortality, cardiovascular mortality, more than mild PVL, permanent pacemaker implantation (PPI) rates and a composite of all-cause mortality and disabling stroke at 6 months. RESULTS:  Among the 166 included patients, 108 patients received the SE ER THV and 58 patients were treated with the BE Myval THV. At baseline, the two groups showed comparable demographic characteristics. The primary composite endpoint of early device success occurred in 55 patients (94.8%) in the BE Myval group and in 90 patients (83.3%) in the SE ER group (OR 3.667, 95% CI 1.094-12.14; p = 0.048). At day 30, the BE Myval THV group exhibited a significantly lower incidence of more than mild PVL (BE Myval 3.45% vs. SE ER 14.8%, OR 0.2, 95% CI 0.05-0.8; p = 0.0338), along with a lower rate of PPI (BE Myval 11% vs. SE ER 24.2%, OR 0.38, 95% CI 0.15-0.99; p = 0.0535). At the 6-month follow-up, the incidence of all-cause mortality and disabling stroke did not significantly differ between the two groups, while the incidence of PPI (BE Myval 11% vs. SE ER 27.5%, OR 0.32, CI 95% 0.1273-0.8; p = 0.02) and ≥moderate PVL (BE Myval 6.9% vs. SE ER 19.8%, OR 0.31, 95% CI 0.1-0.94; p = 0.0396) was significantly lower in the BE Myval group. CONCLUSIONS: In patients with severe symptomatic AS undergoing TAVR, the novel Myval BE THV provided a comparable performance to the well-known ER SE THV, and it was associated with a lower rate of PPI and ≥moderate PVL within 30 days and 6 months after the procedure. Randomized, head-to-head comparison trials are needed to confirm our results.

7.
J Cardiovasc Med (Hagerstown) ; 22(12): e29-e31, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34747930
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA