Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(11)2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-38004917

RESUMO

Metal oxide semiconductor (MOS) gas sensors are widely used for gas detection. Typically, the hotplate element is the key component in MOS gas sensors which provide a proper and tunable operation temperature. However, the low power efficiency of the standard hotplates greatly limits the portable application of MOS gas sensors. The miniaturization of the hotplate geometry is one of the most effective methods used to reduce its power consumption. In this work, a new method is presented, combining electron beam lithography (EBL) and focused ion beam (FIB) technologies to obtain low power consumption. EBL is used to define the low-resolution section of the electrode, and FIB technology is utilized to pattern the high-resolution part. Different Au++ ion fluences in FIBs are tested in different milling strategies. The resulting devices are characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), and secondary ion mass spectrometry (SIMS). Furthermore, the electrical resistance of the hotplate is measured at different voltages, and the operational temperature is calculated based on the Pt temperature coefficient of resistance value. In addition, the thermal heater and electrical stability is studied at different temperatures for 110 h. Finally, the implementation of the fabricated hotplate in ZnO gas sensors is investigated using ethanol at 250 °C.

2.
Sensors (Basel) ; 22(13)2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35808284

RESUMO

Platelets are emerging as a promising source of blood biomarkers for several pathologies, including cancer. New automated techniques for easier manipulation of platelets in the context of lab-on-a-chips could be of great support for liquid biopsy. Here, several polymeric materials were investigated for their behavior in terms of adhesion and activation of human platelets. Polymeric materials were selected among the most used in microfabrication (PDMS, PMMA and COC) and commercial and home-made resins for 3D printing technology with the aim to identify the most suitable for the realization of microdevices for human platelets isolation and analysis. To visualize adherent platelets and their activation state scanning, electron microscopy was used, while confocal microscopy was used for evaluating platelets' features. In addition, atomic force microscopy was employed to further study platelets adherent to the polymeric materials. Polymers were divided in two main groups: the most prone to platelet adhesion and materials that cause few or no platelets to adhere. Therefore, different polymeric materials could be identified as suitable for the realization of microdevices aimed at capturing human platelets, while other materials could be employed for the fabrication of microdevices or parts of microdevices for the processing of platelets, without loss on surfaces during the process.


Assuntos
Plaquetas , Adesividade Plaquetária , Adsorção , Materiais Biocompatíveis , Humanos , Biópsia Líquida , Microscopia Eletrônica de Varredura , Adesividade Plaquetária/fisiologia , Polímeros
3.
Nanotechnology ; 33(30)2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35385839

RESUMO

Highly porous Germanium surfaces with uniformly distributed columnar nanovoid structures are fabricated over a large area (wafer scale) by large fluence Sn+irradiation through a thin silicon nitride layer. The latter represents a one-step highly reproducible approach with no material loss to strongly increase photon harvesting into a semiconductor active layer by exploiting the moth-eye antireflection effect. The ion implantation through the nitride cap layer allows fabricating porous nanostructures with high aspect ratio, which can be tailored by varying ion fluence. By comparing the reflectivity of nanoporous Ge films with a flat reference we demonstrate a strong and omnidirectional reduction in the optical reflectivity by a factor of 96% in the selected spectral regions around 960 nm and by a factor of 67.1% averaged over the broad spectral range from 350 to 1800 nm. Such highly anti-reflective nanostructured Ge films prepared over large-areas with a self-organized maskless approach have the potential to impact real world applications aiming at energy harvesting.

4.
Micromachines (Basel) ; 9(7)2018 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-30424278

RESUMO

A chromatic vectorial strain sensor constituted by hexagonal voids on transparent elastomeric substrate has been successfully fabricated via soft colloidal lithography. Initially a highly ordered 1.6 microns polystyrene spheres monolayer colloidal crystal has been realized by wedge-shaped cell method and used as a suitable mold to replicate the periodic structure on a polydimethylsiloxane sheet. The replicated 2D array is characterized by high periodicity and regularity over a large area, as evidenced by morphological and optical properties obtained by means of SEM, absorption and reflectance spectroscopy. In particular, the optical features of the nanostructured elastomer have been investigated in respect to uniaxial deformation up to 10% of its initial length, demonstrating a linear, tunable and reversible response, with a sensitivity of 4.5 ± 0.1 nm/%. Finally, it has been demonstrated that the specific geometrical configuration allows determining simultaneously the vectorial strain-stress information in the x and y directions.

5.
J Phys Condens Matter ; 30(32): 324001, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-29947619

RESUMO

Germanium (Ge) surfaces have been irradiated with 26 keV gold (Au) ions at a constant fluence and at incidence angles varying from 0° to 85°. The evolution of the emerging nanostructures is studied by atomic force microscopy (AFM), scanning electron microscopy, x-ray photoelectron spectroscopy (XPS), and cross-sectional transmission electron microscopy. The obtained results are compared with findings reported in the literature. Periodic rippled patterns with the wave vector parallel to the projection of the ion beam direction onto the Ge surface develop between 30° and 45°. From 75° the morphology changes from parallel-mode ripples to parallel-mode terraces, and by further increasing the incidence angle the terraces coarsen and show a progressive break-up of the front facing the ion beam. No perpendicular-mode ripples or terraces have been observed. The analysis of the AFM height profiles and slope distributions shows in the 45°-85° range an angular dependence of the temporal scale for the onset of nonlinear processes. For incidence angles below 45°, the surface develops a sponge-like structure, which persists at higher incidence angles on the top and partially on the face of the facets facing the ion beam. The XPS and the energy-dispersive x-ray spectroscopy evidence the presence of Au nano-aggregates of different sizes for the different incidence angles. This study points out the peculiar behavior of Ge surfaces irradiated with medium-energy Au ions and warns about the differences to be faced when trying to build a universal framework for the description of semiconductor pattern evolution under ion-beam irradiation.

6.
J Nanobiotechnology ; 13: 51, 2015 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-26311037

RESUMO

BACKGROUND: Molecularly imprinted polymer (MIP) technique is a powerful mean to produce tailor made synthetic recognition sites. Here precipitation polymerization was exploited to produce a library of MIP nanoparticles (NPs) targeting the N terminus of the hormone Hepcidin-25, whose serum levels correlate with iron dis-metabolisms and doping. Biotinylated MIP NPs were immobilized to NeutrAvidin™ SPR sensor chip. The response of the MIP NP sensor to Hepcidin-25 was studied. FINDINGS: Morphological analysis showed MIP NPs of 20-50 nm; MIP NP exhibited high affinity and selectivity for the target analyte: low nanomolar Kds for the interaction NP/Hepcidin-25, but none for the NP/non regulative Hepcidin-20. The MIP NP were integrated as recognition element in SPR allowing the detection of Hepcidin-25 in 3 min. Linearity was observed with the logarithm of Hepcidin-25 concentration in the range 7.2-720 pM. LOD was 5 pM. The response for Hepcidin-20 was limited. Hepcidin-25 determination in real serum samples spiked with known analyte concentrations was also attempted. CONCLUSION: The integration of MIP NP to SPR allowed the determination of Hepcidin-25 at picomolar concentrations in short times outperforming the actual state of art. Optimization is still needed for real sample measurements in view of future clinical applications.


Assuntos
Hepcidinas/sangue , Impressão Molecular , Nanopartículas/química , Ressonância de Plasmônio de Superfície/métodos , Hepcidinas/metabolismo , Humanos , Ferro/metabolismo , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA