Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Cornea ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38692691

RESUMO

PURPOSE: The aim of this study was to describe the clinical features and endothelial involvement in a case of Mpox virus keratitis by in vivo confocal microscopy (IVCM). METHODS: This is a case report. RESULTS: A 35-year-old man presented with redness, photophobia, pain, tearing, and a low visual acuity of 0.09 (decimal) in the left eye with a 6-week history of Mpox and corneal trauma. Previous testing of blood, interdigital skin lesions, and conjunctival and eyelid margin swabs confirmed the presence of Mpox by polymerase chain reaction. Biomicroscopy displayed superficial stromal infiltrates with a continuous but irregular epithelium. IVCM revealed the presence of pseudoguttata, loss of defined cell boundaries, infiltration of inflammatory cells in the endothelial layer, endothelial ridges, and precipitated pigmented granules, consistent with endotheliitis. After this episode, the patient had 4 reactivations, also treated with topical corticoids and oral tecovirimat 600 mg twice a day for 2 weeks. On the fourth reactivation, this treatment was extended to 4 weeks. On the last visit, the patient presented a visual acuity of 0.5 with disciform keratitis and reduced endotheliitis signs. The endothelial cell density remained normal during the follow-up (2763 ± 376 cell/mm2 at baseline and 2795 ± 238 cell/mm2 at the last visit). Polymegathism and pleomorphism showed altered values during the follow-up. CONCLUSIONS: Patients with an altered corneal epithelial barrier could suffer Mpox endotheliitis, like other DNA viruses, before disciform keratitis appears. IVCM is a useful tool for the early detection of endotheliitis and for describing its evolution, improving patient care.

2.
Bioengineering (Basel) ; 10(9)2023 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-37760115

RESUMO

To build a representative 3D finite element model (FEM) for intracorneal ring segment (ICRS) implantation and to investigate localized optical changes induced by different ICRS geometries, a hyperelastic shell FEM was developed to compare the effect of symmetric and progressive asymmetric ICRS designs in a generic healthy and asymmetric keratoconic (KC) cornea. The resulting deformed geometry was assessed in terms of average curvature via a biconic fit, sagittal curvature (K), and optical aberrations via Zernike polynomials. The sagittal curvature map showed a locally restricted flattening interior to the ring (Kmax -11 to -25 dpt) and, in the KC cornea, an additional local steepening on the opposite half of the cornea (Kmax up to +1.9 dpt). Considering the optical aberrations present in the model of the KC cornea, the progressive ICRS corrected vertical coma (-3.42 vs. -3.13 µm); horizontal coma (-0.67 vs. 0.36 µm); and defocus (2.90 vs. 2.75 µm), oblique trefoil (-0.54 vs. -0.08 µm), and oblique secondary astigmatism (0.48 vs. -0.09 µm) aberrations stronger than the symmetric ICRS. Customized ICRS designs inspired by the underlying KC phenotype have the potential to achieve more tailored refractive corrections, particularly in asymmetric keratoconus patterns.

3.
J Refract Surg ; 39(2): 128-134, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36779470

RESUMO

PURPOSE: To report the visual and refractive outcomes, intraoperative and postoperative complications, and main causes of bilensectomy in the different types of phakic intraocular lenses (pIOLs). METHODS: This was a retrospective multicenter study that included 234 eyes of 185 patients that underwent bilensectomy. Patients were divided into three groups depending on the pIOL that was explanted (angle-supported, iris-fixated, or posterior chamber). The main reasons leading to the indication for bilensectomy, time elapsed between pIOL implantation and bilensectomy, intraoperative and postoperative complications, uncorrected and corrected distance visual acuity (UDVA and CDVA), and endothelial cell density loss 1 year after bilensectomy were evaluated. RESULTS: There was a statistically significant improvement in UDVA and CDVA after bilensectomy in all groups. Cataract development was the main reason for bilensectomy, followed by significant endothelial cell density loss. Time between pIOL implantation and bilensectomy was significantly greater in eyes with an anterior chamber pIOL. CONCLUSIONS: Bilensectomy outcomes in general are good. Iris-fixated lenses, particularly hyperopic, are more prone to intraoperative complications and endothelial cell loss than the other pIOLs models. The results show that bilensectomy is a safe and effective procedure with a relatively low rate of intraoperative and postoperative complications and acceptable refractive predictability. [J Refract Surg. 2023;39(3):128-134.].


Assuntos
Lentes Intraoculares Fácicas , Humanos , Acuidade Visual , Refração Ocular , Complicações Pós-Operatórias , Iris/cirurgia , Estudos Retrospectivos , Seguimentos
4.
Graefes Arch Clin Exp Ophthalmol ; 261(1): 161-170, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35857089

RESUMO

PURPOSE: To analyze the anatomical and functional results of Boston type I keratoprosthesis (B1-KPro) as a primary corneal procedure in high-risk (HR) cases and non-high-risk (NHR) cases. METHODS: In this retrospective interventional case series, all patients who underwent B1-KPro at a single center between January 2006 and March 2021 were reviewed and identified. Cases were classified according to the primary diagnosis. Anatomical failure was considered in the case of prosthesis extrusion or phthisis bulbi. Functional failure was a postoperative corrected distance visual acuity (CDVA) ≥ 1.3 LogMAR (≤ 0.05 decimal) at the end of the follow-up period. RESULTS: Twenty-three eyes were included for analysis. Thirteen eyes were classified as HR and 10 as NHR. The mean age was 46.5 ± 26.5 years (5-84 years) in the HR group and 49.5 ± 26.9 years (2-78 years) in the NHR group. The mean follow-up was 42.0 ± 35.9 months (1.5-118 months) in HR and 44.8 ± 38.8 months (1-107 months) in NHR. Three eyes in the HR and none in the NHR group showed anatomical failure. Functional failure was reported in 5/13 eyes in the HR and 8/10 in the NHR group. Functional cumulative survival probability was 92% and 82% for the HR group at 1 and 2 years, respectively. In the NHR group, it was 27% at both times. No significant differences were found between groups, except for functional survival in the HR group due to better visual potential of the eyes. CONCLUSIONS: B1-KPro as a primary corneal procedure is a valid option for visual rehabilitation in high-risk cases.


Assuntos
Órgãos Artificiais , Doenças da Córnea , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Córnea/cirurgia , Próteses e Implantes , Estudos Retrospectivos , Doenças da Córnea/diagnóstico , Doenças da Córnea/cirurgia , Implantação de Prótese , Complicações Pós-Operatórias/cirurgia , Seguimentos
5.
Int J Mol Sci ; 23(21)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36362082

RESUMO

Soemmerring's rings consist of a ring of lens epithelial derived cells that grow along the periphery of an aphakic lens capsule, or around an intraocular lens. These rings when visualized frontally, appear opaque, however, in some cases the cells that compose these rings are organized in the same fashion as those in normal transparent adult lenses. Thus, our purpose was to test whether any part of the adult Soemmerring's ring could be transparent and how this related to morphological factors. To study this, 16 Soemmerring's rings were extracted from donor eye globes. After imaging, they were thickly sectioned sagittally in order to analyze the degrees of transparency of different areas. All samples were also histologically analyzed using alpha smooth muscle actin, Vimentin, wheat germ agglutinin and DAPI. Our results showed that many samples had some transparent areas, mostly towards the center of their cross-section. Of the factors that we analyzed, only lens fiber organization at the bow region and an increased area of mature lens fiber cells had a significant relation to the degree of transparency at the center. Thus, we can conclude that as Soemmerring's rings mature, they can develop organized and transparent areas of lens cells.


Assuntos
Cápsula do Cristalino , Cristalino , Lentes Intraoculares , Humanos , Epitélio
6.
Rev Esp Patol ; 55 Suppl 1: S7-S10, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36075668

RESUMO

We present a case of a 53-year-old female with an 11 year history of myasthenia gravis (MG) with palpebral ptosis in the left eye which had become more marked over the previous year. Examination revealed a painless left orbital mass causing ptosis. The tumor was surgically removed and histopathology revealed deposits of a hyaline substance which when stained with Congo Red had an apple-green birefringence with polarized light, typical of amyloid. In the absence of amyloid deposits elsewhere in the body, amyloid tumor (AT) was diagnosed. No myelo- or lymphoproliferative syndromes, systemic involvement by amyloidosis or any autoimmune disease were found. The evolution and aesthetic results where satisfactory. Only two cases of orbital AT associated with MG have been described previously; however, in one of the cases, the symptoms of the AT had led to a false diagnosis of MG.


Assuntos
Amiloidose , Miastenia Gravis , Neoplasias Orbitárias , Amiloide , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Miastenia Gravis/complicações
7.
J Cataract Refract Surg ; 48(1): 32-36, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074995

RESUMO

PURPOSE: To compare the accuracy of the equivalent keratometry reading (EKR) from a color LED corneal topographer (Cassini) with that of other no-history formulas for intraocular lens (IOL) power calculation in eyes with previous myopic excimer laser surgery. SETTING: Centro de Oftalmología Barraquer, Barcelona, Spain. DESIGN: Retrospective case series. METHODS: The refractive outcomes of the Cassini EKR entered into the Haigis formula were compared with those of the Barrett True-K, Haigis-L, and Shammas-PL formulas and the Triple-S method combined with the Haigis formula. Optimized lens constants for virgin eyes were used. The mean prediction error (PE), the median absolute error (MedAE), and the percentage of eyes with a PE within ±0.25 diopter (D), ±0.50 D, ±0.75 D, and ±1.00 D were calculated. RESULTS: The study comprised 37 patients (37 eyes). The Haigis-L, Shammas-PL, and Barrett True-K no-history methods produced a myopic mean PE that was significantly different from zero (P < .001, P < .001 and P = .004, respectively), whereas the mean PEs of Cassini EKR and the Triple-S combined with the Haigis formula were not different from zero (P > .05). Repeated-measures analysis of variance disclosed a significant difference among the PE of all methods (P < .0001). The MedAE of the Cassini EKR, Barrett True-K, Haigis-L, Shammas-PL, and Triple-S was, respectively, 0.34 D, 0.34 D, 0.49 D, 0.48 D, and 0.31 D (P = .0026). CONCLUSIONS: The performance of the combination of standard Haigis formula with Cassini EKR was comparable to other no-history formulas in eyes with previous myopic excimer laser surgery.


Assuntos
Lentes Intraoculares , Facoemulsificação , Procedimentos Cirúrgicos Refrativos , Biometria , Humanos , Implante de Lente Intraocular , Óptica e Fotônica , Leitura , Refração Ocular , Estudos Retrospectivos
8.
Eur J Ophthalmol ; 32(5): 2954-2960, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34854773

RESUMO

PURPOSE: To compare the accuracy of Sirius ray tracing software with the Barrett Universal II formula for intraocular lens power prediction in virgin eyes. METHODS: Retrospective case series including 86 eyes that have undergone uneventful cataract surgery with SN60WF implantation. The median absolute error, mean prediction error, variance, and the percentage of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the prediction error in refraction were calculated. The correlation of prediction error with different baseline parameters was investigated. RESULTS: No differences were found between the median absolute error of the Barrett Universal II formula (0.226 D) and the ray tracing software with different intraocular lens centerings; apex (0.331 D), limbus (0.345 D), and pupil (0.342 D) (p = 0.084). The variance, from lowest to highest, was the Barrett Universal II (0.144 D2), ray tracing-limbus (0.285 D2), ray tracing-pupil (0.285 D2), and ray tracing-apex (0.287 D2) (p = 0.027). The Barrett Universal II formula showed a higher percentage of eyes within ± 0.25 D (56.98%), ± 0.50 D (82.56%), and ± 0.75 D (93.02%) compared to ray tracing software (p < 0.01). A significant correlation between the prediction error of the Barrett Universal II formula and corneal diameter (r = 0.322, p = 0.002) and pupil diameter (r = 0.230, p = 0.033) was found. Also, a positive correlation between the prediction error of Sirius ray tracing and axial length (p < 0.001) and pupil diameter (p = 0.01) was found. CONCLUSION: There is a trend of the Barrett Universal II formula to be more accurate than Sirius ray tracing software for intraocular lens power calculation in virgin eyes. This should be confirmed in future prospective comparative studies.


Assuntos
Lentes Intraoculares , Facoemulsificação , Comprimento Axial do Olho , Biometria , Humanos , Implante de Lente Intraocular , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos , Software
9.
Front Med (Lausanne) ; 8: 749063, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660651

RESUMO

Purpose: To analyze the long-term anatomical survival, functional survival, and complications of Boston type 1 keratoprosthesis (KPro) in the eyes with congenital aniridia-associated keratopathy (AAK). Methods: A retrospective review of 12 eyes with congenital aniridia that underwent a Boston type 1 KPro surgery was conducted. A Kaplan-Meier analysis was performed. Anatomical and functional success criteria were KPro retention and a best corrected visual acuity (BCVA) ≤1.3 LogMAR (≥0.05 decimal) at the end of a follow-up period. Postoperative complications were recorded. Results: The mean preoperative BCVA was 2.1 ± 0.9 (range: 3.8-1) LogMAR, and glaucoma was a comorbidity in all the cases. Five years after the surgery, the overall retention rate was 10/12 (83.3%), and 50% had functional success. Only three (25%) of the 12 cases did not achieve a BCVA ≤1.3 LogMAR. The cumulative probability of anatomical success was 92, 79, and 79% after 1, 5, and 10 years, respectively. The cumulative probability of functional success was 57 and 46% after 1 and 5 years, respectively. The mean anatomical and functional survival time was 10 ± 1.3 (95% IC = 7.5-12.3 years) and 3.8 ± 0.9 years (95% IC = 1.8-5.8 years), respectively. The most common postoperative complication was retroprosthetic membrane (RPM) formation in 8/16 cases (66%). The mean number of complications per case was 2.4 ± 1.8 (0-6). Conclusions: The Boston type 1 KPro is a viable option for patients with AAK with good anatomical and functional long-term results. Glaucoma is an important preoperative condition that affects functional results. Retroprosthetic membrane formation seems to have a higher incidence in this condition.

10.
J Refract Surg ; 37(10): 693-699, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34661475

RESUMO

PURPOSE: To analyze the clinical outcomes obtained with asymmetric intracorneal corneal ring segments (ICRS) of variable thickness and width in patients with keratoconus, identifying predictive parameters of the final visual outcome. METHODS: This prospective, longitudinal, non-comparative clinical trial enrolled 35 eyes of 27 patients with keratoconus with a significant difference among corneal topographic and comatic axes. All eyes underwent implantation of AJL-pro+ ICRS (AJL Ophthalmic). Visual, refractive, corneal topographic and aberrometric, and pachymetric changes were evaluated during a 3-month follow-up. RESULTS: Significant changes were detected at 3 months after surgery in manifest sphere and cylinder, spherical equivalent, overall blur strength, and corrected distance visual acuity (CDVA) (P < .001). No losses of two or more lines of CDVA were observed, whereas 94.3% (33) of eyes gained one or more lines of CDVA. Keratometric readings and the magnitude of anterior corneal astigmatism were significantly reduced with surgery (P < .001), as well as the levels of corneal coma (P < .001) and spherical aberration (P = .007). Likewise, a significant change toward less prolateness was observed (P < .001). Significant correlations were found among the change in CDVA and preoperative CDVA (r = -0.532, P = .001), and between the change in primary coma root mean square and the preoperative level of spherical aberration (r = -0.542, P = .001) and coma root mean square (r = -0.719, P < .001). CONCLUSIONS: The implantation of the ICRS evaluated in keratoconus with no coincidence between topographic and comatic axes regularizes the corneal shape and reduces the level of higher order aberrations, inducing a significant visual improvement. [J Refract Surg. 2021;37(10):693-699.].


Assuntos
Ceratocone , Substância Própria/cirurgia , Humanos , Ceratocone/cirurgia , Lasers , Estudos Prospectivos , Próteses e Implantes , Implantação de Prótese
11.
PLoS One ; 16(9): e0257222, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34525102

RESUMO

PURPOSE: To evaluate the local geometric effects of a unilateral intrastromal ring segment with a combined variation of ring thickness and base width in a finite element simulation, and to compare it against the isolated effect of thickness or base width variation alone. METHODS: A two-dimensional finite-element model of a transversely isotropic cornea was created assuming either axisymmetric stress or plane strain condition. The model geometry was composed of a three-layered corneal tissue (epithelium, anterior and posterior stroma) fixed at the limbus. The implantation of a triangular-shape asymmetric ring segment with varying ring thickness (150 to 300 µm) and base width (600 to 800 µm) was simulated. Also, changes induced by thickness or base width alone were studied and compared their combined effect in the asymmetric ring segment. Geometrical deformation of the simulated cornea and sagittal curvature were the main parameters of study. RESULTS: Increasing ring thickness and base width along the arc of the asymmetric ring segment produced a more pronounced flattening in this part of the ring. The asymmetric design did find a good balance between maximizing corneal flattening at one end and minimizing it at the other end, compared to the isolated effect of ring thickness and width. Ring thickness was the most robust parameter in flattening both, the central and peripheral cornea. CONCLUSION: The finite-element model permitted a theoretical study of corneal deformation undergoing implantation of realistic and hypothetical ring geometries. Intracorneal asymmetric ring segments with varying thickness and base width can be a good alternative in corneas with asymmetric keratoconus phenotypes.


Assuntos
Córnea/cirurgia , Topografia da Córnea , Ceratocone/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Refração Ocular , Simulação por Computador , Substância Própria/cirurgia , Olho Artificial , Análise de Elementos Finitos , Humanos , Implantação de Prótese/métodos , Software , Testes Visuais
12.
Invest Ophthalmol Vis Sci ; 62(1): 12, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33427852

RESUMO

Purpose: Human cortical opacities are most commonly accompanied by changes in lens fiber structure in the equatorial region at the lens nucleus-cortex interface. Cortex and nucleus have different elastic properties, which change with age. We therefore subjected ex vivo lenses to simulated accommodation and studied the internal deformations to better understand the mechanism of cortical cataract formation. Methods: Nine human donor lenses (33-88 years old) were tested using a bespoke radial stretching device for anterior eye segments. Seven of the lenses exhibited cortical cataracts. The other two lenses, without cataract, were used as controls. Frontal and cross-sectional images of the lens obtained during stretching facilitated measurements on equatorial lens diameter and central lens thickness in the stretched and unstretched states. Results: Stretching caused the lens equatorial diameter to increase in all cases. Conversely, the lens central thickness showed no systematic variation during stretching. For four of the lenses with cortical cataract, ruptures were observed during stretching at the nucleus-cortex boundary adjacent to the cortical cataracts. Ruptures were not observed in the control lenses or in the three other lenses with cortical cataract. Conclusions: Internal ruptures can occur in aged ex vivo lenses subjected to simulated disaccommodation. These ruptures occur at the nucleus-cortex interface; at this location, a significant stiffness discontinuity is expected to develop with age. It is hypothesized that ruptures occur in in vivo lenses during accommodation-or attempted accommodation.


Assuntos
Acomodação Ocular/fisiologia , Catarata/fisiopatologia , Córtex do Cristalino/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Catarata/diagnóstico por imagem , Estudos Transversais , Humanos , Córtex do Cristalino/diagnóstico por imagem , Pessoa de Meia-Idade , Fotografação , Ruptura Espontânea , Estresse Fisiológico , Doadores de Tecidos
13.
Acta Ophthalmol ; 99(6): e922-e928, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33421330

RESUMO

PURPOSE: To identify the causes of failure of the different surgical corneal graft techniques: penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK), Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK). METHODS: This multicentric retrospective study enrolled a consecutive cohort of patients who had undergone any type of keratoplasty between 2001 and 2016. The clinical data were obtained from the patient's medical records, following ethical guidelines, permissions and data protection. The main outcome measured in the study was the cause of graft failure, defined as any irreversible loss of graft transparency capable of compromising vision. The main causes of graft failure were classified as follows: (A) primary graft failure (PGF), (B) immunological rejection, (C) non-rejection (which includes endothelial decompensation without rejection, IOP elevation/glaucoma, diseases of the ocular surface, recurrence of the primary disease, wound dehiscence/hypotonia and trauma, among others) and (D) specific causes of lamellar keratoplasty failure. A descriptive study of the obtained data was carried out. The distribution of the causes of failure was evaluated according to the type of corneal transplant. RESULTS: Our research included a cohort of 571 keratoplasty failures, of which 509 met the inclusion criteria. The analysis of the causes of the PK failure showed that immunological allograft rejection represented the main cause, with 28.2% of the failures, followed by surface diseases (17.8%) and endothelial decompensation without rejection (17.3%). For the PK re-grafts group, the main cause of failure was immunological allograft rejection (34.0%), followed by diseases of the ocular surface (18.5%). For the DALK group, the failures mainly occurred due to surface diseases such as limbal stem cell insufficiency, infectious keratitis, keratolysis or persistent epithelial defect (37.8%). However, the main reason for failure in the DSAEK group was endothelial decompensation without rejection (31.9%) while primary graft failure was the main cause of failure in the DMEK group (64.1%). CONCLUSION: The main reason for failure in PK was immunological allograft rejection, both in primary and secondary transplants. The leading causes for failure were diseases of the ocular surface in the DALK population, endothelial decompensation without rejection in DSAEK and primary graft failure in DMEK.


Assuntos
Doenças da Córnea/cirurgia , Transplante de Córnea/efeitos adversos , Previsões , Rejeição de Enxerto/etiologia , Acuidade Visual , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos/imunologia , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/imunologia , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Eur J Ophthalmol ; 31(2): NP33-NP38, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32141311

RESUMO

INTRODUCTION: Mooren's ulcer is a painful, inflammatory chronic keratitis that affects corneal periphery, progressing centripetally, ultimately ending in perforation. The first line of treatment includes systemic immunomodulators, with surgery being the last option. We present a case of bilateral Boston keratoprosthesis implantation for severe Mooren's ulcer that responded differently in each eye. CLINICAL CASE: A 32-year-old male with corneal opacification, anterior staphylomas, vision of hand movement, was started on systemic immunosuppression with cyclosporine. After two failed penetrating keratoplasties in each eye, high intraocular pressure despite diode cyclophotocoagulation, and cystic macular edema, we performed Boston keratoprosthesis type 1 in both eyes. The right eye responded initially well, with a best-corrected visual acuity of 20/80 and normal intraocular pressure. The left eye presented high intraocular pressure, which required cyclophotocoagulation, ultimately resulting in hypotony. Boston keratoprosthesis was performed but had peripheral corneal necrosis that progressed despite amniotic membrane transplantation and aggressive intensive treatment with medroxyprogesterone, autologous platelet-rich-in-growth-factors eye drops, and oral doxycycline. Thus, replacement of the semi-exposed Boston keratoprosthesis with tectonic penetrating keratoplasty was necessary. However, both eyes developed phthisis bulbi with final visual acuity of perception of light with poor localization. CONCLUSION: Mainstay treatment of Mooren's ulcer is systemic immunomodulation. Surgical treatment must be considered only when risk of perforation, preferably with inflammation under control. Penetrating keratoplasty frequently fails, and Boston keratoprosthesis may be a viable option. However, postoperative complications, especially uncontrolled high intraocular pressure, corneal necrosis, and recurrence of Mooren's ulcer may jeopardize the outcomes and need to be addressed promptly with intensive topical and systemic treatment.


Assuntos
Órgãos Artificiais , Córnea , Úlcera da Córnea/cirurgia , Próteses e Implantes , Adulto , Antibacterianos/uso terapêutico , Terapia Combinada , Anticoncepcionais Orais Hormonais/uso terapêutico , Doxiciclina/uso terapêutico , Seguimentos , Humanos , Ceratoplastia Penetrante , Masculino , Medroxiprogesterona/uso terapêutico , Soluções Oftálmicas/uso terapêutico , Plasma Rico em Plaquetas/fisiologia , Recidiva , Úlcera , Acuidade Visual
15.
Eur J Ophthalmol ; 31(2): NP136-NP140, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31530022

RESUMO

PURPOSE: To report a case of a unilateral spontaneous filtering bleb dissecting into the cornea in a patient with high myopia. CLINICAL CASE: A 33-year-old woman with high myopia (-18 D) presented with discomfort in the left eye. Ocular history included pars plana vitrectomy and cataract extraction and posterior chamber intraocular lens implantation in the left eye. Best-corrected visual acuity was 0.65 and intraocular pressure was 20 mmHg. Slit-lamp examination showed a filtering bleb in the upper-temporal quadrant, which extended and dissected the proximal cornea without affecting the visual axis. The morphology and content of the bleb was studied with anterior segment optical coherence tomography, which ruled out a corneal-scleral fistulization into the subconjunctival space. The spontaneous filtering bleb was resected surgically. Due to her high myopia, two strips of fascia lata were used to strengthen the area. In the postoperative period, a complete resection of the bleb was confirmed, without apparent leaking points and with a well-vascularized conjunctiva. No complications were noted. The patient maintained the same best-corrected visual acuity and intraocular pressure than before surgery. CONCLUSION: The formation of a spontaneous filtering bleb is a rare entity in patients with high myopia, whose risk increases due to their thinned sclerae. The risk is even greater if they have undergone ocular surgeries. Resection of the filtering bleb in our case halted the progression of the corneal dissection, therefore respecting the transparency of the visual axis and preserving visual acuity.


Assuntos
Doenças da Córnea , Oftalmopatias , Miopia Degenerativa , Malha Trabecular , Adulto , Feminino , Humanos , Extração de Catarata , Doenças da Córnea/etiologia , Oftalmopatias/diagnóstico por imagem , Oftalmopatias/etiologia , Oftalmopatias/cirurgia , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Miopia Degenerativa/complicações , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica/métodos , Malha Trabecular/diagnóstico por imagem , Malha Trabecular/patologia , Malha Trabecular/cirurgia , Acuidade Visual/fisiologia , Vitrectomia
16.
Acta Ophthalmol ; 99(3): e319-e323, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32833309

RESUMO

PURPOSE: To assess correlation between results from both eyes of the same patient after implantation of intrastromal corneal ring segments (ICRS) and define whether they can be used together in clinical studies. METHODS: A review of medical records of 74 patients with keratoconus implanted with bilateral Ferrara ICRS at Centro de Oftalmología Barraquer from January 2005 until December 2014. Data were collected on uncorrected visual acuity, best-corrected visual acuity and subjective refractive values (sphere, cylinder and axis). RESULTS: A total of 39 patients were male (53%), and 35 were female (47%). Mean age at the time of implantation was 32.5 ± 10 years. No major complications occurred. A significant correlation between the results from right and left eyes was found (p < 0.0043), indicating that both eyes significantly resembled each other. No significant interaction in the magnitude of change between eye and surgery was observed under classic and mixed models. CONCLUSION: Based on our data, whenever application is not possible under mixed-model analyses, we recommend the use of a first eye operated only, either right or left, in order to avoid bias and errors derived from autocorrelation and guarantee the independence of the registered observations.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Implantação de Prótese/métodos , Adulto , Feminino , Humanos , Masculino , Próteses e Implantes , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
17.
Am J Ophthalmol ; 222: 351-358, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33011155

RESUMO

PURPOSE: To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and define the incidence rate. DESIGN: Multicenter, observational consecutive case series. METHODS: Consecutive cases of ICRSs explanted in the last 10 years were reviewed. Clinical data included age of the patients at explantation, reasons for implantation and explantation, date of implantation and explantation, tunnel creation technique, and ICRS type. Main outcomes measures were the reasons for ICRS removal and the incidence rate. RESULTS: During the study period, 121 ICRSs (119 patients) were explanted, with an explantation rate of 5.60%. Functional failure (74 eyes, 61.16%) represents the main cause for ICRS removal: of them, 48 (39.67%) ICRSs were removed for refractive failure and 26 (21.49%) in the setting of a keratoplasty related to poor visual performance of the implanted eye. In addition, 47 eyes (38.84%) had ICRS removal for anatomic failure: among them, 36 (29.75%) were explanted for spontaneous extrusion (overall extrusion rate: 1.58%), 7 (5.79%) for suspected infectious keratitis, 3 (2.48%) for corneal melting, and 1 (0.83%) for corneal perforation. Mild cases of keratoconus were more prone to be explanted because of a loss of the initial improved visual acuity, whereas spontaneous extrusion happened often in advanced cases of keratoconus. CONCLUSIONS: We report the largest series of ICRS explantation as of this writing. The main cause of explantation was functional refractive failure followed by spontaneous extrusion of the ICRS, that is, correlated to an anatomic failure at the site of implantation in an advanced disease.


Assuntos
Substância Própria/cirurgia , Remoção de Dispositivo/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Próteses e Implantes/efeitos adversos , Implantação de Prótese/efeitos adversos , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Substância Própria/patologia , Topografia da Córnea , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Miopia/cirurgia , Falha de Prótese , Estudos Retrospectivos
18.
Eye Vis (Lond) ; 7: 34, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32626790

RESUMO

BACKGROUND: To evaluate the safety, efficacy, refractive outcomes and causes for bilensectomy (phakic intraocular lens - pIOL - explantation with cataract surgery and pseudophakic intraocular lens implantation) in patients previously implanted with posterior chamber pIOLs. METHODS: This multi-center retrospective study included 87 eyes of 55 patients who underwent bilensectomy for posterior chamber pIOL with a follow up time of 12 months. The uncorrected and best corrected distance visual acuities (UDVA, CDVA), endothelial cell density before and after bilensectomy were assessed, as well as the cause of bilensectomy and intra or postoperative complications. RESULTS: There was a statistically significant improvement in uncorrected and best corrected visual acuities after bilensectomy (p = 0.00). The main reason for bilensectomy was cataract development (93.1% of the cases), followed by miscalculation of lens size, and corneal edema. The endothelial cell count remained stable without a statistically significant change after surgery (p = 0.67). The refractive efficacy index was 0.8, none of the patients lost lines of CDVA after surgery, 73% of the patients were within ±1 D (spherical equivalent) of the target refraction. Intraoperative complications were one posterior capsule rupture with the intraocular lens (IOL) implanted in the sulcus, and 3 eyes required the use of pupil expanders for adequate pupil dilation. Postoperatively, one eye developed retinal detachment. The three pIOLs models explanted were the Implantable Collamer Lens (ICL), Implantable Phakic Contact Lens (IPCL) and the Phakic Refractive Lens (PRL). CONCLUSIONS: Good safety and visual outcomes were observed 1 year after bilensectomy for posterior chamber phakic intraocular lenses (PC pIOLs). There were few intra and postoperative complications and there was no significant endothelial cell loss after the bilensectomy procedure.

20.
Retina ; 40(5): 903-907, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30845020

RESUMO

PURPOSE: To analyze functional and anatomical results of pars plana vitrectomy (PPV) to treat endophthalmitis in eyes with osteokeratoprosthesis. METHODS: An observational, retrospective study of five eyes suffering from endophthalmitis, after an osteokeratoprosthesis implantation, which underwent PPV associated with intravitreal antibiotics. The minimum follow-up after PPV was 6 months. A descriptive study and a Kaplan-Meier survival analysis for anatomical (attached retina during the follow-up) and functional success (visual acuity ≥20/400) were performed. RESULTS: Best-corrected visual acuity during the final follow-up was 20/100 in 1 case (20%), hand movement in another case (20%), and no light perception in 3 cases (60%). The anatomical survival rates were recorded at 80%, 60%, and 40% at 1, 6, and 8 months respectively, and this last value was maintained at 12 months after PPV. The functional survival rates were recorded at 40% and 20% at 1 month and 8 months, respectively, and this last value was maintained at 12 months after PPV. CONCLUSION: Endophthalmitis in eyes with previous osteokeratoprosthesis is a very severe complication with a reserved prognosis. Pars plana vitrectomy associated with intravitreal antibiotics leads to maintaining or increasing visual acuity in a small proportion of patients who otherwise would end up blind.


Assuntos
Córnea/cirurgia , Doenças da Córnea/cirurgia , Endoftalmite/cirurgia , Infecções Oculares Bacterianas/cirurgia , Próteses e Implantes , Acuidade Visual , Vitrectomia/métodos , Adulto , Idoso , Doenças da Córnea/complicações , Endoftalmite/complicações , Infecções Oculares Bacterianas/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA