Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 517
Filtrar
1.
Hand (N Y) ; : 15589447241259804, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38902997

RESUMO

BACKGROUND: A2 pulley release is often needed for exposure of the lacerated tendon, retrieval of retracted tendons, placement of core sutures, or to permit full motion and gliding of the repaired and edematous tendon. However, there is no agreement in the literature on the specific quantity of pulley venting that can be performed and recommendations are limited to an undefined "judicious release" of the pulleys when necessary. METHODS: Following a previously developed testing protocols, finger kinematics, tendon excursion, and bowstringing were evaluated on cadaveric hands for venting in increments of 20% of the pulley length. RESULTS: In our study, we found a statistically significant influence of venting on bowstringing, although no difference was found between fingers, and a significant difference in tendon slack, which was variable depending on the finger. Bowstringing started increasing at 20% of A2 venting and peaked at full release. Tendon slack did not start until 40% of A2 venting on the index finger, but started at 20% on the middle, ring, and small fingers. CONCLUSIONS: Venting of the A2 pulley leads to an incremental increase in tendon bowstringing and tendon slack. However, differences in metacarpophalangeal flexion angle were not observed until full A2 pulley release, and only observed in the index finger, and no differences were observed in proximal interphalangeal flexion angles. Therefore, the benefit of releasing the A2 pulley when clinically necessary will likely outweigh the risks of loss of motion or strength.

2.
Orthop Traumatol Surg Res ; : 103900, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38703888

RESUMO

BACKGROUND: The Terrible Triad of the elbow is a constellation of elbow dislocation, radial head fracture and coronoid process fracture. A common type of coronoid fracture documented with this triad is type II Regan-Morrey coronoid fractures. The preferred fixation method for this fracture type is the lasso technique, medial-lateral tunnel orientation being the traditional approach. Considering elbow anatomy, we saw an opportunity to potentially improve fixation by altering the suture lasso tunnel orientation to a proximal-distal orientation. HYPOTHESIS: Two tunnels in the proximal-distal direction would result in greater biomechanical stability as compared to the traditional lasso technique. MATERIAL AND METHODS: A type 2 Regan-Morrey fracture was created in 12 fresh frozen cadaveric elbows at 50% of the coronoid height using an oscillating saw. The humero-ulnar joint was placed in 0 degrees flexion then loaded at a rate of 10mm/min to failure. RESULTS: The control technique (medio-lateral tunnels) showed failure load of 150±81N that was not significantly different (p=0.825) than the 134±116N measured for the modified technique (distal-proximal tunnels). The portion of the load-displacement curve used to calculate stiffness was linear (R^2=0.94±0.04) with determination coefficients that did not differ between the two groups (p=0.351). For stiffness, we measured 17±13N/mm and 14±12N/mm respectively for control and modified techniques that did not result in a significant difference (p=0.674). CONCLUSION: In this attempt to improve the shortcomings of the lasso technique, we found that changing from medio-lateral to proximal-distal drilling directions did not result in an appreciable biomechanical benefit. LEVEL OF EVIDENCE: Basic science study; Biomechanics.

3.
Lancet Respir Med ; 12(6): 467-475, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38490228

RESUMO

BACKGROUND: Systematic mediastinal lymph node staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) improves accuracy of staging in patients with early-stage non-small-cell lung cancer (NSCLC). However, patients with locally advanced NSCLC commonly undergo only selective lymph node sampling. This study aimed to determine the proportion of patients with locally advanced NSCLC in whom systematic endoscopic mediastinal staging identified PET-occult lymph node metastases, and to describe the consequences of PET-occult disease on radiotherapy planning. METHODS: This prospective, international, multicentre, single-arm, international study was conducted at seven tertiary lung cancer centres in four countries (Australia, Canada, the Netherlands, and the USA). Patients aged 18 years or older with suspected or known locally advanced NSCLC underwent systematic endoscopic mediastinal lymph node staging before combination chemoradiotherapy or high-dose palliative radiotherapy. The primary endpoint was the proportion of participants with PET-occult mediastinal lymph node metastases shown following systematic endoscopic staging. The study was prospectively registered with Australian New Zealand Clinical Trials Registry, ACTRN12617000333314. FINDINGS: From Jan 30, 2018, to March 23, 2022, 155 patients underwent systematic endoscopic mediastinal lymph node staging and were eligible for analysis. 58 (37%) of patients were female and 97 (63%) were male. Discrepancy in extent of mediastinal disease identified by PET and EBUS-TBNA was observed in 57 (37% [95% CI 29-44]) patients. PET-occult lymph node metastases were identified in 18 (12% [7-17]) participants, including 16 (13% [7-19]) of 123 participants with clinical stage IIIA or cN2 NSCLC. Contralateral PET-occult N3 disease was identified in nine (7% [2-12]) of 128 participants staged cN0, cN1, or cN2. Identification of PET-occult disease resulted in clinically significant changes to treatment in all 18 patients. In silico dosimetry studies showed the median volume of PET-occult lymph nodes receiving the prescription dose of 60 Gy was only 10·1% (IQR 0·1-52·3). No serious adverse events following endoscopic staging were reported. INTERPRETATION: Our findings suggests that systematic endoscopic mediastinal staging in patients with locally advanced or unresectable NSCLC is more accurate than PET alone in defining extent of mediastinal involvement. Standard guideline-recommended PET-based radiotherapy planning results in suboptimal tumour coverage. Our findings indicate that systematic endoscopic staging should be routinely performed in patients with locally advanced NSCLC being considered for radiotherapy to accurately inform radiation planning and treatment decision making in patients with locally advanced NSCLC. FUNDING: None.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Metástase Linfática , Mediastino , Estadiamento de Neoplasias , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Masculino , Feminino , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Mediastino/patologia , Metástase Linfática/radioterapia , Austrália , Países Baixos , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Canadá , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estados Unidos , Tomografia por Emissão de Pósitrons/métodos
4.
Instr Course Lect ; 73: 109-121, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090891

RESUMO

Simulation-based training is required by many medical specialties. Barriers, however, have prevented widespread implementation of simulators for arthroscopic training. The advantages of arthroscopic simulator-based training of residents include decreased errors, decreased cost of training, and improved patient care. Before an educational program can focus on the type of simulator, it is essential to have a validated curriculum and framework for how to use those simulators. One of the most validated systems is called proficiency-based progression training. Proficiency-based progression is essentially a paradigm in which basic skills must be mastered and demonstrated via objective evaluation, before moving on to more advanced skills. There are a variety of different validation methods and tools that have been described, with the Arthroscopic Surgical Skill Evaluation Tool being the most widely used tool. It is essential that any simulator has evidence and validation that it will ultimately improve surgical skills in the operating room. In the future, emerging technologies such as virtual reality, augmented reality, and three-dimensional printing will likely play a major role in the creation of newer simulators and may improve access to residents throughout the world.


Assuntos
Internato e Residência , Treinamento por Simulação , Humanos , Competência Clínica , Artroscopia/educação , Treinamento por Simulação/métodos , Salas Cirúrgicas
5.
Pathophysiology ; 30(2): 83-91, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37092522

RESUMO

Total hip arthroplasty is a widely performed operation allowing disabled patients to improve their quality of life to a degree greater than any other elective procedure. Planning for a THA requires adequate patient assessment and preoperative characterizations of acetabular bone loss via radiographs and specific classification schemes. Some surgeons may be inclined to ream at a larger diameter thinking it would lead to a more stable press-fit, but this could be detrimental to the acetabular wall, leading to intraoperative fracture. In the attempt to reduce the incidence of intraoperative fractures, the current study aims to identify how increased reaming diameter degrades and weakens the acetabular rim strength. We hypothesized that there is proportionality between the reaming diameter and the reduction in acetabular strength. To test this hypothesis, this study used bone surrogates, templated from CT scans, and reamed at different diameters. The obtained bone surrogate models were then tested using an Intron 8874 mechanical testing machine (Instron, Norwood, MA) equipped with a custom-made fixture. Analysis of variance (ANOVA) was used to identify differences among reamed diameters while linear regression was used to identify the relationship between reamed diameters and acetabular strength. We found a moderate correlation between increasing reaming diameter that induced thinning of the acetabular wall and radial load damage. For the simplified acetabular model used in this study, it supported our hypothesis and is a promising first attempt in providing quantitative data for acetabular weakening induced by reaming.

6.
J Prev Alzheimers Dis ; 10(1): 19-24, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36641606

RESUMO

BACKGROUND: Alzheimer's disease is a large and growing unmet medical need. Clinical trial designs need to assess disease-related outcomes earlier to accelerate the development of better treatments for Alzheimer's disease. ACU193 is a monoclonal antibody that selectively targets amyloid ß oligomers, thought to be the most toxic species of Aß that accumulates early in AD and contributes to downstream pathological effects. Nonclinical data indicate that ACU193 can reduce the toxic effects of amyloid ß oligomers. ACU193 is currently being investigated in a phase 1 clinical trial designed with the properties described in this report. This phase 1 trial is designed to provide data to enable a go/no-go decision regarding the initiation of a subsequent phase 2/3 study. OBJECTIVES: To design a phase 1 study that assesses target engagement and incorporates novel measures to support more rapid development of a potential disease-modifying treatment for Alzheimer's disease. DESIGN: The INTERCEPT-AD trial for ACU193 is an ongoing randomized, placebo-controlled phase 1a/b study that assesses safety, tolerability, pharmacokinetics, target engagement, clinical measures, and several Alzheimer's disease biomarkers, including novel digital and imaging biomarkers. SETTING: For INTERCEPT-AD, brief inpatient stays for patients in the single ascending dose portion of the study, with the remainder of the evaluations being performed as outpatients at multiple clinical trial sites in the U.S. PARTICIPANTS: Patients with early Alzheimer's disease (mild cognitive impairment or mild dementia with a positive florbetapir positron emission tomography scan). INTERVENTION: ACU193 administered intravenously at doses of 2- 60 mg/kg. MEASUREMENTS: Safety assessments including magnetic resonance imaging for the presence of amyloid-related imaging abnormalities, clinical assessments for Alzheimer's disease including the Alzheimer's Disease Rating Scale-cognition and Clinical Dementia Rating scale, pharmacokinetics, a measure of target engagement, and digital and imaging biomarkers, including a computerized cognitive test battery and a measure of cerebral blood flow using arterial spin labelling magnetic resonance imaging. RESULTS: A phase 1 study design was developed for ACU193 that allows collection of data that will enable a go/no-go decision for initiation of a subsequent adaptive phase 2/3 study. CONCLUSIONS: A phase 1a/b trial and an overall clinical development plan for an Alzheimer's disease treatment can be designed that maintains patient safety, allows informed decision-making, and achieves an accelerated timeline by using novel biomarkers and adaptive study designs.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/psicologia , Peptídeos beta-Amiloides , Anticorpos Monoclonais/efeitos adversos , Biomarcadores , Planejamento Social , Ensaios Clínicos Fase I como Assunto
7.
Ochsner J ; 22(3): 204-210, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36189099

RESUMO

Background: Early (2020) reports on mortality in patients with coronavirus disease 2019 (COVID-19) who underwent orthopedic surgery ranged from 20.5% to 56%, but these studies included elderly patients with multiple comorbidities. The mortality rate for younger and asymptomatic COVID-19-positive patients undergoing orthopedic surgery after high-energy trauma is underreported. The purpose of this study was to compare the 30-day mortality of asymptomatic COVID-19-positive patients and COVID-19-negative patients surgically treated for orthopedic trauma at a Level I trauma center during the coronavirus pandemic. A secondary objective was to compare the patients' postoperative hospital course and length of stay. Methods: This study is a single-center retrospective review of all patients who underwent an orthopedic surgical procedure at a Level I trauma center during a 3-month period early in the COVID-19 pandemic. All patients received a preoperative nasopharyngeal swab to determine COVID-19 infection status. Preoperative demographic variables, perioperative and postoperative mortality within 30 days, length of stay, and intensive care unit days were compared between COVID-19-positive and COVID-19-negative patients. Results: Of the 471 total patients, 13 were COVID-19-positive and 458 were COVID-19-negative prior to surgery. The average age of all patients was 40.5 ± 19.8 years. The mortality rate in the COVID-19-positive group was 0% vs 0.7% in the COVID-19-negative group, with no significant difference between groups (P=0.77). The COVID-19-positive group vs the COVID-19-negative group had no significant difference in hospital length of stay (7.4 days vs 4.4 days, respectively, P=0.12). Conclusion: Asymptomatic COVID-19-positive orthopedic trauma patients treated with surgery at a Level I trauma center in a 3-month period during the COVID-19 pandemic had a 0% mortality rate, and we found no differences between COVID-19-positive and COVID-19-negative patients with respect to mortality and hospital length of stay.

8.
BMC Pulm Med ; 22(1): 364, 2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36153502

RESUMO

BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is established as the preferred method of mediastinal lymph node (LN) staging in non-small cell lung cancer (NSCLC). Selective (targeted) LN sampling is most commonly performed however studies in early stage NSCLC and locally advanced NSCLC confirm systematic EBUS-TBNA evaluation improves accuracy of mediastinal staging. This study aims to establish the rate of detection of positron emission tomography (PET)-occult LN metastases following systematic LN staging by EBUS-TBNA, and to determine the utility of systematic mediastinal staging for accurate delineation of radiation treatment fields in patients with locally advanced NSCLC. METHODS: Consecutive patients undergoing EBUS-TBNA for diagnosis/staging of locally advanced NSCLC will be enrolled in this international multi-centre single arm study. Systematic mediastinal LN evaluation will be performed, with all LN exceeding 6 mm to be sampled by TBNA. Where feasible, endoscopic ultrasound staging (EUS-B) may also be performed. Results of minimally invasive staging will be compared to FDG-PET. The primary end-point is proportion of patients in whom systematic LN staging identified PET-occult NSCLC metastases. Secondary outcome measures include (i) rate of nodal upstaging, (ii) false positive rate of PET for mediastinal LN assessment, (iii) analysis of clinicoradiologic risk factors for presence of PET-occult LN metastases, (iv) impact of systematic LN staging in patients with discrepant findings on PET and EBUS-TBNA on target coverage and dose to organs at risk (OAR) in patients undergoing radiotherapy. DISCUSSION: With specificity of PET of 90%, guidelines recommend tissue confirmation of positive mediastinal LN to ensure potentially early stage patients are not erroneously denied potentially curative resection. However, while confirmation of pathologic LN is routinely sought, the exact extent of mediastinal LN involvement in NSCLC in patient with Stage III NSCLC is rarely established. Studies examining systematic LN staging in early stage NSCLC report a significant discordance between PET and EBUS-TBNA. In patients with locally advanced disease this has significant implications for radiation field planning, with risk of geographic miss in the event of PET-occult mediastinal LN metastases. The SEISMIC study will examine both diagnostic outcomes following systematic LN staging with EBUS-TBNA, and impact on radiation treatment planning. TRIAL REGISTRATION: ACTRN12617000333314, ANZCTR, Registered on 3 March 2017.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/patologia , Mediastino/diagnóstico por imagem , Mediastino/patologia , Estudos Multicêntricos como Assunto , Estadiamento de Neoplasias , Estudos Prospectivos
9.
OTA Int ; 5(2): e203, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35919107

RESUMO

Background: Intertrochanteric femur fractures are a common orthopaedic injury that are often treated surgically. Cephalomedullary nails (CMN) are frequently the implant of choice for intertrochanteric femur fractures, resulting in low complication rates. Implant failure is a rare but reported complication. Common locations of failure include the proximal nail aperture, distal screw holes, and implant shaft. In this case report, we describe a CMN failure pattern through fenestrated cephalic screw holes. Case: A 70-year-old female sustained an OTA 31A-2.2 peritrochanteric fracture during a motor vehicle collision. She was treated the following day with a Synthes Trochanteric Fixation Nail-Advanced CMN utilizing a fenestrated cephalic screw. There were no intraoperative complications. She was made non-weight bearing for 8 weeks after the procedure due to ipsilateral foot fractures. At 6 months follow-up she was noted to have a delayed union. 11 months postoperatively she suffered a ground level fall and the cephalic lag screw failed through its fenestrations, resulting in varus collapse of her fracture at the femoral neck. The patient then underwent nail extraction and salvage total hip arthroplasty. Conclusion: Cephalomedullary nail implant failure is presented with implant fracture propagation through a fenestrated cephalic screw. Cephalomedullary lag screw failure is rare and can be difficult to manage. It is important to monitor new implants for unique failure mechanisms.

10.
Arthrosc Sports Med Rehabil ; 4(3): e927-e933, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35747650

RESUMO

Purpose: To evaluate Workers' Compensation (WC) patients who underwent arthroscopic shoulder surgery for workplace shoulder injuries and to determine whether there was an association between earlier return to light duty and earlier return to full duty. Methods: After receiving institutional review board approval, we performed a retrospective chart review of all WC patients treated with shoulder arthroscopic surgery by 2 senior authors between 2011 and 2018. The patients were divided into 2 groups: Group 1 went back to light-duty work within the first 100 days after surgery, whereas group 2 performed light-duty work after 100 days or performed no light-duty work. The primary outcomes included the length of time from surgery to light-duty work and the length of time from surgery to return to the full-duty work level. Results: A total of 59 patients met the inclusion criteria. There was a moderate correlation between the number of days at which the patients were released to light duty and the days they were able to be released to full duty (r = 0.35). In group 1 (light duty ≤ 100 days), 18 patients (75%) went back to full duty, whereas only 16 patients (46%) in group 2 were able to return to full-duty work (P = .025). Conclusions: Earlier return to light duty is associated with earlier return to full duty after shoulder arthroscopic surgery in patients with a Workers' Compensation claim. Additionally, WC patients who returned to early light duty in the first 100 days postoperatively had a higher rate of return to full duty than did patients who did not return to early light duty. Level of Evidence: Level III, case-control study.

11.
Agric Ecosyst Environ ; 332: 1-13, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35400773

RESUMO

Nitrogen (N) fertilizer applications are important for agricultural yield, yet not all the applied N is taken up by crops, leading to surplus N storage in soil or leaching to groundwater and surface water. Leaching loss of fertilizer N represents a cost for farmers and has consequences for human health and the environment, especially in the southern Willamette Valley, Oregon, USA, where groundwater nitrate contamination is prevalent. While improved nutrient management and conservation practices have been implemented to minimize leaching, nitrate levels in groundwater continue to increase in many long-term monitoring wells. To elucidate controls on leaching rates and N dynamics in agricultural soils across soil depths, and in response to seasonal and annual variation in management (e.g., fertilizer input amount and summer irrigation), we intensively monitored the transport of water and nitrate every two weeks for four years through the vadose zone at three depths (0.8, 1.5, and 3.0 m) in a sweet corn (maize) field. Though nitrate leaching was highly variable among lysimeters at the same depth and across years, a strong pattern emerged: annual nitrate leaching significantly decreased with depth across the study, averaging ~104 kg N ha-1 yr-1 near the surface (0.8 m) versus ~56 kg N ha-1 yr-1 in the deep soil (3.0 m), a 54% reduction in leaching between the soil layers. Even though crops were irrigated in summer, most leaching (~72% below 3.0 m) occurred during the wet fall and winter. Based on steady state assumptions, a net equivalent of ~29% of surface N inputs leached below 3.0 m into the deeper soil and groundwater, while ~44% was removed in crop harvest, indicating considerable N retention in the soil (~27% of inputs or approximately 58 kg N ha-1 yr-1). The accumulation and long-term dynamics of deep soil N is a legacy of agricultural management that should be further studied to better manage and reduce nitrate loss to groundwater.

12.
Artigo em Inglês | MEDLINE | ID: mdl-35355780

RESUMO

Radiation exposure of orthopaedic residents should be accurately monitored to monitor and mitigate risk. The purpose of this study was to determine whether a personalized lead protocol (PLP) with a radiation monitoring officer would improve radiation exposure monitoring of orthopaedic surgery residents. Materials and Methods: This was a retrospective case-control study of 15 orthopaedic surgery residents monitored for radiation exposure during a 2-year period (March 2017 until February 2019). During the first 12-month period (phase 1), residents were given monthly radiation dosimeter badges and instructed to attach them daily to the communal lead aprons hanging outside the operating rooms. During the second 12-month period (phase 2), a PLP (PLP group) was instituted in which residents were given lead aprons embroidered with their individual names. A radiation safety officer was appointed who placed the badges monthly on all lead aprons and collected them at the end of the month, whereas faculty ensured residents wore their personalized lead apron. Data collected included fluoroscopy use time and radiation dosimeter readings during all orthopaedic surgeries in the study period. Results: There were 1,252 orthopaedic surgeries using fluoroscopy during phase 1 in the control group and 1,269 during phase 2 in the PLP group. The total monthly fluoroscopy exposure time for all cases averaged 190 minutes during phase 1 and 169 minutes during phase 2, with no significant difference between the groups (p < 0.45). During phase 1, 73.1% of the dosimeters reported radiation exposure, whereas during phase 2, 88.7% of the dosimeters reported radiation exposure (p < 0.001). During phase 1, the average monthly resident dosimeter exposure reading was 7.26 millirems (mrem) ± 37.07, vs. 19.00 mrem ± 51.16 during phase 2, which was significantly higher (p < 0.036). Conclusions: Institution of a PLP increased the compliance and exposure readings of radiation dosimeter badges for orthopaedic surgery residents, whereas the actual monthly fluoroscopy time did not change. Teaching hospitals should consider implementing a PLP to more accurately monitor exposure. Level of Evidence: 3.

13.
Orthop Traumatol Surg Res ; 108(4): 103273, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35331920

RESUMO

INTRODUCTION: Pelvic internal fixation has become a popular method for treatment of unstable pelvic ring injuries. Although successful, one complication is femoral nerve palsy from compression of the connecting rod. In light of this complication, this study was designed to evaluate sagittal inclinations of the rod and the feasibility of using a rod with a constant curvature. HYPOTHESIS: It is hypothesized that that there is a connection between the sagittal inclination of the rod and the rod to bone distance, as well as single rod can be contoured with a constant curvature to be used in the majority of all patients. METHODS: Three dimensional models of pelvis CTs from a single level 1 trauma center were created and imported into a program where software superimposed a pre-contoured rod in the sagittal planes upon the pelvic slices. The sagittal inclination was deemed acceptable is no interference occurred between the area of compression risk and the rod. For each pelvis and considered sagittal rod inclination, the rod radius of curvature (ROC), minimal rod to bone distance (RTB) and transverse inclinations (φL and φR) were measured at which the pedicle screws should be inserted to follow the direction of the smallest RTB. RESULTS: The sagittal inclinations feasible for all subjects were between 15° to 30°. In this sagittal range, the average RTB varied in values ranging from 4.0±0.9mm to 25.4±11.4mm (p<0.01). Only 46% of subjects allowed a rod with constant curvature. DISCUSSION AND CONCLUSION: Our study found that a rod to bone distance of 15mm was not safe for all models. As well, many subject models did not allow placement of pre-contoured rod. Patient specific templating of pelvic subcutaneous internal fixation is strictly needed to limit complications. LEVEL OF EVIDENCE: VII; Basic Science.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Ossos Pélvicos , Traumatismos dos Nervos Periféricos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Pelve
14.
Eur J Orthop Surg Traumatol ; 32(8): 1609-1616, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34652554

RESUMO

PURPOSE: To evaluate whether graft-type and tunnel location in ACL reconstruction impact patient-reported outcomes in individuals over the age of 45. METHODS: From 2015 to 2018, patients over 45 years old undergoing primary ACL reconstruction without multi-ligamentous injuries were enrolled in an institutional registry. Baseline International Knee Documentation Committee (IKDC) subjective scores, Knee Injury and Osteoarthritis Outcome Scores (KOOS), Marx Activity Scale, and patient characteristics were collected. Follow-up occurred at a minimum of two years to obtain patient-reported outcomes. RESULTS: Of the 51 patients who qualified for the study, 44 (86.3%) patients were available at a minimum of two years after surgery date (range 24-60 months). Average age at time of surgery of the available patients was 51.6 ± 4.87 (range 45-66). Between femoral tunnel drilling methods, there were no differences in the proportion of patients achieving clinically significant improvement or post-operative outcome scores. While patients who received patellar tendon autografts were more likely to achieve clinically significant improvement in the KOOS sports subscale, there were no other differences in outcomes measures between graft types. Two patients had a retear of their graft, and an additional five patients complained of subjective instability. CONCLUSIONS: In patients over the age of 45, neither the method used to create the femoral tunnel nor the graft type used in ACL reconstruction caused a significant difference in post-operative PROMs with a minimum of two years of follow-up. LEVEL OF EVIDENCE: Therapeutic IV, Case Series.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Pré-Escolar , Pessoa de Meia-Idade , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/etiologia , Reoperação , Autoenxertos , Articulação do Joelho/cirurgia
15.
Respirology ; 27(2): 152-160, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34792268

RESUMO

BACKGROUND AND OBJECTIVE: Endosonography with intrathoracic nodal sampling is proposed as the single test with the highest granuloma detection rate in suspected sarcoidosis stage I/II. However, most studies have been performed in limited geographical regions. Studies suggest that oesophageal endosonographic nodal sampling has higher diagnostic yield than endobronchial endosonographic nodal sampling, but a head-to-head comparison of both routes has never been performed. METHODS: Global (14 hospitals, nine countries, four continents) randomized clinical trial was conducted in consecutive patients with suspected sarcoidosis stage I/II presenting between May 2015 and August 2017. Using an endobronchial ultrasound (EBUS) scope, patients were randomized to EBUS or endoscopic ultrasound (EUS)-B-guided nodal sampling, and to 22- or 25-G ProCore needle aspiration (2 × 2 factorial design). Granuloma detection rate was the primary study endpoint. Final diagnosis was based on cytology/pathology outcomes and clinical/radiological follow-up at 6 months. RESULTS: A total of 358 patients were randomized: 185 patients to EBUS-transbronchial needle aspiration (EBUS-TBNA) and 173 to EUS-B-fine-needle aspiration (FNA). Final diagnosis was sarcoidosis in 306 patients (86%). Granuloma detection rate was 70% (130/185; 95% CI, 63-76) for EBUS-TBNA and 68% (118/173; 95% CI, 61-75) for EUS-B-FNA (p = 0.67). Sensitivity for diagnosing sarcoidosis was 78% (129/165; 95% CI, 71-84) for EBUS-TBNA and 82% (115/141; 95% CI, 74-87) for EUS-B-FNA (p = 0.46). There was no significant difference between the two needle types in granuloma detection rate or sensitivity. CONCLUSION: Granuloma detection rate of mediastinal/hilar nodes by endosonography in patients with suspected sarcoidosis stage I/II is high and similar for EBUS and EUS-B. These findings imply that both diagnostic tests can be safely and universally used in suspected sarcoidosis patients.


Assuntos
Endossonografia , Sarcoidose , Biópsia por Agulha Fina , Broncoscopia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Linfonodos/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Mediastino/patologia , Sarcoidose/diagnóstico por imagem
16.
World J Orthop ; 12(11): 931-937, 2021 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34888153

RESUMO

BACKGROUND: Allergic contact dermatitis (ACD) secondary to Dermabond Prineo™ is rare, but documented. To our knowledge, there are no described reports of this ACD reaction within the pediatric population following arthroscopic surgery. CASE SUMMARY: We report two cases of pediatric ACD upon second exposure to Dermabond Prineo™ after knee arthroscopy. Both cases presented within two weeks of the inciting second exposure. The cases resolved with differing described combinations of sterile cleaning, diphenhydramine, and antibiotic administration. No long-term sequelae were found. CONCLUSION: This case report elucidates the rare complication of allergic dermatitis secondary to Dermabond Prineo™ repeat exposure use in pediatric arthroscopy.

17.
Arthrosc Tech ; 10(10): e2357-e2363, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34754745

RESUMO

This article reviews a technique for arthroscopic fixation of an osteochondritis dissecans fragment with bone marrow aspirate concentrate augmentation. This technique involves safe harvest of bone marrow arthroscopically from the intercondylar notch, proper preparation and debridement of the parent bone, reduction of the progeny osteochondritis dissecans fragment, insertion of the bone marrow aspirate concentrate, and placement of multiple headless compression screws for fixation.

18.
Arthrosc Sports Med Rehabil ; 3(5): e1255-e1262, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34712961

RESUMO

PURPOSE: To determine the ideal location for anterior cruciate ligament (ACL) suspensory cortical button placement on the lateral femur with the highest failure load and to establish the relationship of tunnel diameter and cortical thickness on load to failure. METHODS: Computed tomography (CT) data were obtained from 45 cadaveric distal femurs. A Cartesian coordinate system was established along the lateral femur with the lateral epicondyle (LE) as a reference point. Locations 0, 20 and 30 mm from the LE along lines 0°, 25°, 50°, and 75° posterioproximal from the axial plane were created. Tunnels connecting from each location to the center of the ACL footprint were simulated. Cortical thickness and long axis diameter of the oval cortical holes were determined for each location. Based on the CT data, custom drill guides were created and used to drill 4.5 mm tunnels at each lateral femur location to the ACL footprint on the cadaver femurs. Cortical buttons were placed at each location and pulled using a servohydraulic testing system. The correlation of tunnel diameter and cortical thickness to button failure load were analyzed using a regression analysis. RESULTS: Significant differences were found for failure load (P<.0001) and cortical thickness between the locations tested (P<.0001). The location 30 mm proximal from the LE and 75° from the axial plane had the highest failure load of 573 N. A regression analysis (R2 = .15) indicated that the cortical thickness was significantly correlated with load to failure (P <.0001), whereas the long-axis diameter was not (P = .33). CONCLUSION: The ideal cortical button location on the lateral femur for ACL suspensory fixation was located 30 mm proximal from the lateral epicondyle, based on this area's high failure load. Oblique tunnel drilling of this proximal location may cause a larger long-axis diameter cortical hole, but the cortex is also thicker, which is more closely correlated with failure load. CLINICAL RELEVANCE: Different ACL suspensory cortical button locations on the lateral femur have different failure loads based on the cortical thickness of the bone supporting the button. It is important for surgeons to understand which drilling techniques place the button in a proximal and posterior location, especially if the bone quality of the patient is of concern.

19.
JSES Int ; 5(3): 549-553, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34136869

RESUMO

BACKGROUND: The ulnar collateral ligament (UCL) complex of the elbow plays a primary role in valgus and posteromedial stability of the elbow. The anterior oblique ligament (AOL) of the UCL is believed to provide the majority of resistance to external forces on the medial elbow. The transverse ligament (TL) of the UCL is generally thought to have minimal contribution to the elbow's overall stability. However, recent studies have suggested a more significant role for the TL. The primary aim of this study was to identify the TL's contribution to the stability of the elbow joint in determining the joint stiffness and neutral zone variation in internal rotation. METHODS: Twelve cadaveric elbows, set at a 90° flexion angle, were tested by applying an internal rotational force on the humerus to generate a medial opening torque at the level of the elbow. The specimens were preconditioned with 10 cycles of humeral internal rotation with sinusoidal torque ranging from 0 to 5 Nm. Elbow stiffness measures and joint neutral zone were first evaluated in its integrity during a final ramp loading. The test was subsequently repeated after cutting the TL at 33%, 66%, and 100% followed by the AOL in the same fashion. RESULTS: The native UCL complex joint stiffness to internal rotation measured 1.52 ± 0.51 Nm/°. The first observable change occurred with 33% sectioning of the AOL, with further sectioning of the AOL minimizing the joint stiffness to 1.26 ± 0.32 Nm/° (P = .004). A 33% resection of the TL found an initial neutral zone variation of 0.376 ± 0.23° that increased to 0.771 ± 0.41° (P < .01) at full resection. These values were marginal when compared with the full resection of the AOL for which we have found 3.69 ± 1.65° (P < .01). CONCLUSION: The TL had no contribution to internal rotation elbow joint stiffness at a flexion angle of 90°. However, sequential sectioning of the TL was found to significantly increase the joint neutral zone when compared with the native cadaveric elbow at a flexion angle of 90°. This provides evidence toward the TL having some form of contribution to the elbow's overall stability.

20.
Cartilage ; 13(1_suppl): 928S-936S, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33855864

RESUMO

OBJECTIVE: To compare radius of curvature (RoC) of distal femur osteochondral autograft transfer (OAT) donor sites from the intercondylar notch and trochlear ridge with recipient sites on the distal and posterior condyles and evaluate differences between recipient sites. DESIGN: Nineteen cadaveric femurs were scanned with a 3-dimensional high-resolution sensor. Donor regions included the lateral (LTR) and medial trochlear ridges (MTR), and the lateral (LICN) and medial intercondylar notch (MICN). Recipient regions analyzed were the distal medial (DMFC), posterior medial (PMFC), distal lateral (DLFC), and posterior lateral femur condyle (PLFC). Six-millimeter OAT grafts were simulated, and average RoC of all regions was compared using an analysis of variance. Post hoc testing was performed using Fisher's least significant difference. RESULTS: We found no significant differences in RoC of the LICN compared with all 4 recipient sites (P = 0.19, 0.97, 0.11, and 0.75 for DLFC, PLFC, DMFC, and PMFC, respectively) or the LTR and MTR to the posterior condyles (LTR vs. PLFC and PMFC; P = 0.72, 0.47, MTR vs. PLFC and PMFC P = 0.39, 0.22, respectively). Significant differences were found for RoC of the MICN compared with each recipient site (P < 0.001) and between distal and posterior femoral condyles (DLFC vs. PLFC, P = 0.016; DMFC vs. PMFC, P = 0.023). CONCLUSION: The LICN is the ideal donor option for all recipient sites on the femoral condyles with respect to RoC of 6-mm OAT plugs. The MTR and LTR were acceptable donor sources for the posterior condyles, while the MICN was a poor match for all recipient sites. Additionally, the distal femur condyle and posterior femur condyle have different RoCs.


Assuntos
Autoenxertos , Fêmur/cirurgia , Fraturas Intra-Articulares , Rádio (Anatomia) , Sítio Doador de Transplante , Idoso , Cadáver , Feminino , Humanos , Joelho , Masculino , Pessoa de Meia-Idade , Transplante Autólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA