Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Am J Cardiol ; 228: 24-33, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39097151

RESUMO

Transcatheter mitral edge-to-edge repair (TEER) with transcatheter devices has become a mainstay in the minimally invasive treatment of patients with severe mitral regurgitation at increased surgical risk. Despite its apparently favorable risk profile, there is uncertainty on the risk and features of cerebrovascular accidents (CVAs) early and long after transcatheter mitral valve repair. We aimed to appraise the incidence and predictors of CVA in patients who underwent TEER. We explicitly queried the data set of an ongoing multicenter prospective observational study dedicated to TEER with MitraClip (Abbott Vascular, Santa Clara, California). The incidence of CVAs after TEER was formally appraised, and we explored potential predictors of such events. Descriptive, bivariate, and diagnostic accuracy analyses were performed. Of 2,238 patients who underwent TEER, CVAs occurred in 33 patients (1.47% [95% confidence interval 1.02% to 2.06%]), including 6 (0.27% [0.10% to 0.58%]) in-hospital strokes and 27 events after discharge (0.99% [0.66% to 1.44%]), over a median follow-up of 14 months. Most CVAs were major ischemic strokes during and after the in-hospital phase. Overall, CVAs were more common in patients with atrial fibrillation (p = 0.018), renal dysfunction (p = 0.032), higher EuroSCORE II (p = 0.033), and, as expected, higher CHA2DS2-VASc score (p = 0.033), despite the limited prognostic accuracy of the score. Notably, the occurrence of CVA did not confer a significantly increased risk of long-term (p = 0.136) or cardiac death (p = 0.397). The incidence of CVA in patients who underwent TEER is low, with most events occurring after discharge and being associated with preexisting risk features. These findings, although reassuring on the safety of TEER, call for proactive antithrombotic therapy whenever CVA risk is increased before and after TEER.

2.
Front Cardiovasc Med ; 11: 1367515, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39015678

RESUMO

Background: Even though the optimal management of a moderate or large residual shunt following patent foramen ovale (PFO) closure is open to question, recent data confirmed that it is associated with an increased risk of stroke recurrence. Case summary: A 48-year-old woman, a migraineur with visual aura, was diagnosed with a PFO associated with a huge multifenestrated atrial septal aneurysm (mfASA) and a moderate right-to-left shunt, detectable only after a Valsalva maneuver on contrast-transthoracic echocardiography. Brain magnetic resonance imaging showed a 1-mm silent white matter lesion in the right frontal lobe. Although the indication was not supported by guidelines, a transcatheter PFO closure was performed at another center with implantation of a large, equally sized, double-disc device (Figulla UNI 33/33 mm). At 6-month follow-up, a 2D/3D transesophageal echocardiography (TEE) color Doppler showed incorrect orientation of the device, which was not parallel to the interatrial septum, with two discs failing to capture the aortic muscular rim and partially protruding in the right atrium; furthermore, a 4 mm × 7 mm ASA fenestration was documented with a residual bidirectional shunt. Thereafter, the same team performed a minimally invasive cardiac surgery under femoro-femoral cardiopulmonary bypass; however, the procedure proved ineffective and was complicated by postoperative pericarditis with pericardial effusion, requiring further rehospitalization 1 month later due to persistent pericarditis, bilateral pleuritis, phrenic nerve palsy, and atrial flutter, which was treated with amiodarone. The patient asked for a second opinion, and our multidisciplinary heart team decided to offer a percutaneous redo intervention. An uneventful implantation of a regular PFO occluder (Figulla Flex II 16/18 mm) across the septal defect was performed successfully. Twelve-month follow-up with 2D TTE color Doppler and contrast transcranial Doppler showed correct position and good interaction between the two devices, with no residual shunt. Discussion: In addition to the incorrect indication for PFO closure and the failure of minimally invasive surgery, the procedural mishap in this case could have been due to the inappropriate implantation of the first large device within the tunnel. It would have been better to deploy the same large device in the most central fenestration, covering the PFO and a greater part of the remaining mfASA at the same time.

3.
Int J Cardiol ; 413: 132317, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986745

RESUMO

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal M-TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing M-TEER had a Euroscore<4% with a median age of 81. An optimally successful M-TEER was associated with a lower mortality regardless of EuroSCORE.

4.
J Clin Med ; 13(14)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39064213

RESUMO

Ischemic heart disease is currently the most common cause of mortality and morbidity worldwide. Although myocardial ischemia is classically determined by epicardial coronary atherosclerosis, up to 40% of patients referred for coronary angiography have no obstructive coronary artery disease (CAD). Ischemia with non-obstructive coronary artery disease (INOCA) has typically been underestimated in the past because, until recently, its prognostic significance was not completely clear. This review aims to highlight differences and patterns in myocardial ischemia caused by epicardial obstructive CAD, coronary microvascular dysfunction (CMD) or vasomotor abnormalities and to elucidate the state of the art in correctly diagnosing these different patterns.

5.
Clin Res Cardiol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046472

RESUMO

BACKGROUND: To assess the interaction between heart failure (HF) severity and optimal reduction of secondary mitral regurgitation (SMR) on mortality in patients undergoing transcatheter edge-to-edge repair (M-TEER). METHODS AND RESULTS: Among 1656 patients included in the Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) 984 had SMR and complete data on advanced HF. Advanced HF was defined as NYHA class III or IV, left ventricular ejection fraction ≤ 30%, and > 1 HF hospitalization during the last 12 months. Optimal M-TEER was defined as residual SMR ≤ 1 + at discharge. One hundred sixteen patients (11.8%) had advanced HF. Achievement of an optimal SMR reduction was similar in patients with and without advanced HF (65% and 60% respectively). Advanced HF was an independent predictor of 2-year all-cause death (adjusted HR 1.52, 95% CI 1.09-2.10). Optimal M-TEER, as compared to a no-optimal M-TEER, was associated with a reduced risk of death both in patients with advanced (HR 0.55, 95% CI 0.32-0.97; p = 0.039) and no-advanced HF (HR 0.59, 95% CI 0.46-0.78; p < 0.001; p = 0.778 for interaction). CONCLUSIONS: Advanced HF is associated with poor outcome in patients undergoing M-TEER. However, an optimal SMR reduction reduces the risk of 2-year mortality regardless of HF severity.

6.
Eur Heart J Suppl ; 26(Suppl 1): i6-i10, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38867865

RESUMO

The COAPT 5-year data demonstrate that compared with medical treatment transcatheter edge-to-edge repair (TEER) with the MitraClip in symptomatic patients with Grade 3+/Grade 4+ secondary mitral regurgitation (SMR) reduced by nearly half the annualized hospitalization risk (33 vs. 57%), by almost 30% the death rate (57 vs. 67%) and achieved significant and durable SMR reduction in 95% of patients. Control patients who crossed over to TEER at 2 years had better prognosis, but nearly half of them died before reaching crossover eligibility. Death or hospitalization for heart failure (HHF) occurred in 73.6% of TEER patients and 91.5% of controls within 5 years, pointing to a need for further study to address left ventricle (LV) dysfunction, the underlying cause of patient's disease. MTRA-FR targeted SMR using the same device and did not improve the composite endpoint of all-cause mortality or HHF at 12 months. Possible reasons for the discrepancy include enrolment of patients with more severe MR and less-advanced LV disease (dilation/dysfunction), less-procedural complications, and higher success in reducing MR in COAPT compared with MITRA-FR. Thus, the ideal patient for MitraClip treatment would be one with severe MR, but with no too severe LV dilation/dysfunction, which is what differentiates COAPT patients from those in MITRA-FR.

7.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38742523

RESUMO

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Itália/epidemiologia , Idoso de 80 Anos ou mais , Readmissão do Paciente/estatística & dados numéricos , Falha de Tratamento , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia
8.
Artigo em Inglês | MEDLINE | ID: mdl-38714459

RESUMO

BACKGROUNDS: The impact of quantitative assessment to differentiate total occlusions (TOs) from severe stenoses on coronary computed tomography angiography (CCTA) remains unknown. OBJECTIVE: This study investigated whether quantitative characteristics assessed on CCTA could help differentiate a TO from a severe stenosis on invasive coronary angiography (ICA). METHODS: This study is a sub-analysis of the FASTTRACK CABG (NCT04142021) in which both CCTA and ICA were routinely performed. Quantitative analysis was performed with semi-automated CCTA plaque-analysis software. Blinded analysts compared TOs on CCTA, defined as a complete lack of contrast opacification within the coronary occlusion, with corresponding ICA. RESULTS: Eighty-four TOs were seen on CCTA in 59 of the 114 patients enrolled in the trial. The concordance in diagnosing a TO between ICA and CCTA was 56.0% (n â€‹= â€‹47). Compared to severe stenoses, TOs had a significantly longer lesion length (25.1 â€‹± â€‹23.0 â€‹mm vs 9.4 â€‹± â€‹11.2 â€‹mm, P â€‹< â€‹0.001). The best cut-off value to differentiate a TO from severe stenosis was a lesion length of 5.5 â€‹mm (area under the curve 0.77, 95% CI: 0.66-0.87), with a 91.1% sensitivity and 61.1% specificity. Dense calcium percentage atheroma volume (PAV) was significantly higher in TOs compared to severe stenoses (18.7 â€‹± â€‹19.6% vs. 6.6 â€‹± â€‹13.0%, P â€‹< â€‹0.001), whilst the opposite was seen for fibro-fatty PAV (31.3 â€‹± â€‹14.2% vs. 19.5 â€‹± â€‹10.5%, P â€‹< â€‹0.001). On a multivariable logistic regression analysis, lesion length (>5.5 â€‹mm) was the only parameter associated with differentiating a TO from a severe stenosis. CONCLUSION: In quantitative CCTA analysis, a lesion length >5.5 â€‹mm was the only independent predictor differentiating a TO from a severe stenosis. NCT REGISTRATION NUMBER: NCT04142021.

9.
J Cardiovasc Comput Tomogr ; 18(4): 375-382, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38641453

RESUMO

INTRODUCTION: Congenital coronary artery anomalies (CCAA) represent one of the most challenging conditions as their clinical presentation may range from sudden cardiac death to a complete subclinical form. The aim of the present study was to evaluate the diagnostic and prognostic role of cardiac CT (CCT) evaluation in patients with CCAA, focusing on anomalies of origin. MATERIAL AND METHODS: The present is a retrospective analysis of a prospective clinical registry including a consecutive cohort of patients who underwent clinically indicated CCT from January 2007 to October 2015 for suspected but unknown coronary artery disease (CAD) and were diagnosed for having a congenital coronary abnormality compared to a control group matched for age, sex and segment stenosis score (SSS). Dedicated analysis of all CCT was performed for the present study and only coronary anomalies of origin were considered and included in the study. Two different composite end-points were identified for the present analysis: major cardiovascular events (MACE) and all-cause of death. RESULTS: Among the 81 patients with CCAAs enrolled the most frequent anomaly was left main artery absence, which was identified in 41 individuals (50.6%). Forty-five subjects (55.5%) have an anomalous origin of the coronary artery from a different sinus of Valsalva and 45 subjects had also an anomalous course with the retro-aortic being the most common (32%). Eleven participants (13.6%) displayed also an intramural segment, while 10 (10.3%) had a slit-like ostial morphology. At multivariate analysis CT identification of ARCA, anomalous inter-arterial course and abnormal ostial morphology were significantly associated with MACE even when adjusted for age and SSS, without any differences in all-cause mortality between the two groups (6.2% vs 2.4% p â€‹= â€‹0.2478). CONCLUSION: The result of the present study is that CCT can be successfully used to define the anatomy and features of CAA. It suggested that in middle-aged patients, the identification of high risk characteristics at CT may have a prognostic value in term of cardiovascular events occurrence at follow-up even if the rate of events strictly linked to CCAA is low.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Anomalias dos Vasos Coronários , Valor Preditivo dos Testes , Sistema de Registros , Humanos , Feminino , Masculino , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/mortalidade , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Prognóstico , Vasos Coronários/diagnóstico por imagem , Causas de Morte , Idoso , Medição de Risco , Seguimentos , Adulto , Tomografia Computadorizada Multidetectores , Progressão da Doença
10.
J Invasive Cardiol ; 36(8)2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38598251

RESUMO

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Feminino , Masculino , Cateterismo Cardíaco/métodos , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Estudos Prospectivos , Sistema de Registros , Ecocardiografia Transesofagiana/métodos , Seguimentos , Próteses Valvulares Cardíacas
11.
Int J Cardiol ; 406: 131997, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556216

RESUMO

AIMS: Myocardial bridging (MB) is a frequent congenital anomaly of the epicardial coronary arteries commonly considered a benign condition. However, in some cases a complex interplay between anatomical, clinical and physiology factors may lead to adverse events, including sudden cardiac death. Coronary CT angiography (CCTA) emerged as the gold standard noninvasive imaging technique for the evaluation of MB. Aim of the study was to evaluate MB prevalence and anatomical features in a large population of patients who underwent CCTA for suspected CAD and to identify potential anatomical and clinical predictors of adverse cardiac events at long-term follow-up. METHODS AND RESULTS: Two-hundred and six patients (mean age 60.3 ± 11.8 years, 128 male) with MB diagnosed at CCTA were considered. A long MB was defined as ≥25 mm of overlying myocardium, whereas a deep MB as ≥2 mm of overlying myocardium. The study endpoint was the sum of the following adverse events: cardiac death, bridge-related acute coronary syndrome, hospitalization for angina or bridge-related ventricular arrhythmias and MB surgical treatment. Of the 206 patients enrolled in the study, 9 were lost to follow-up, whereas 197 (95.6%) had complete follow-up (mean 7.01 ± 3.0 years) and formed the analytic population. Nineteen bridge-related events occurred in 18 patients (acute coronary syndrome in 7, MB surgical treatment in 2 and hospitalization for bridge-related events in 10). Typical angina at the time of diagnosis and long MB resulted as significant independent predictors of adverse outcome. CONCLUSIONS: Typical angina and MB length ≥ 25 mm were independent predictors of cardiac events.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte Miocárdica , Valor Preditivo dos Testes , Humanos , Masculino , Ponte Miocárdica/diagnóstico por imagem , Ponte Miocárdica/complicações , Ponte Miocárdica/epidemiologia , Feminino , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Seguimentos , Angiografia Coronária/métodos , Estudos Retrospectivos
13.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100347, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-39131939

RESUMO

Background: Coronary obstruction following transcatheter aortic valve replacement (TAVR) is a life-threatening complication. For patients at elevated risk, it is not known how valve choice is influenced by clinical and anatomic factors and how outcomes differ between valve platforms. For patients at high risk of coronary obstruction, we sought to describe the anatomical and clinical characteristics of patients treated with both balloon-expandable (BE) and self-expanding (SE) valves. Methods: This was a multicenter international registry of patients undergoing TAVR who are considered to be at high risk of coronary obstruction and receiving pre-emptive coronary protection. Results: A total of 236 patients were included. Patients receiving SE valves were more likely to undergo valve-in-valve procedures and also had smaller sinuses of Valsalva and valve-to-coronary distance. Three-year cardiac mortality was 21.6% with SE vs 3.7% with BE valves. This was primarily driven by increased rates of definite or probable coronary occlusion, which occurred in 12.1% of patients with SE valves vs 2.1% in patients with BE valves. Conclusions: In patients undergoing TAVR with coronary protection, those treated with SE valves had increased rates of clinical and anatomic features that increase the risk of coronary obstruction. These include an increased frequency of valve-in-valve procedures, smaller sinuses of Valsalva, and smaller valve-to-coronary distances. These patients were observed to have increased cardiac mortality compared with patients treated with BE valves, but this is likely due to their higher risk clinical and anatomic phenotypes rather than as a function of the valve type itself.

14.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1353336

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite , Substituição da Valva Aórtica Transcateter
15.
Circ., cariovasc. interv. (Print) ; 14(6): 010440, June. 2021. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352656

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bio prostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population.


Assuntos
Estenose da Valva Aórtica , Próteses e Implantes , Substituição da Valva Aórtica Transcateter
16.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1148174
17.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Assuntos
Sistema de Registros , Incidência , Endocardite , Substituição da Valva Aórtica Transcateter
18.
Catheter. cardiovasc. interv ; 93(1): 1-7, Jan. 2019. gráfico, tabela
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024591

RESUMO

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. (AU)


Assuntos
Humanos , Trombose , Intervenção Coronária Percutânea , Everolimo
19.
Catheter Cardiovasc Interv ; 91(7): 1-8, June 2018. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061868

RESUMO

BACKGROUND: Preclinical data showed that overlapping (OVP) scaffolds might result in delayed healing and strut coverage compared to nonOVP scaffold segments. Furthermore, OVP in patients could result in increased periprocedure myocardial infarction (MI) rate secondary to side branch occlusion; however, little is known whether this may have an impact on long-term clinical outcomes. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. In this study, we compared the immediate and 2-year clinical outcomes of patients with OVP scaffolds (n = 115) to those of patients with nonOVP scaffolds (n = 697). The primary objective was the comparison of major adverse cardiac event (MACE) (cardiac death, MI and ischemic-driven target lesion revascularization [TLR]) and scaffold thrombosis (ST) rates up to 2 years...


Assuntos
Assistência Perioperatória , Cicatrização , Infarto do Miocárdio
20.
Catheter Cardiovasc Interv ; 91(3): 387-395, 2018. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061866

RESUMO

OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. METHODS:The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups...


Assuntos
Coração , Stents , Stents Farmacológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA