Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Front Cardiovasc Med ; 11: 1388171, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756751

RESUMO

Background: Advancements in cardiac imaging have revolutionized our understanding of ventricular contraction. While ejection fraction (EF) is still the gold standard parameter to assess left ventricle (LV) function, strain imaging (SI) has provided valuable insights into ventricular mechanics. The lack of an integrative method including SI parameters in a single, validated formula may limit its use. Our aim was to compare different methods for evaluating global circumferential strain (GCS) and their relationship with global longitudinal strain (GLS) and EF in CMR and how the different evaluations fit in the theoretical relationship between EF and global strain. Methods: Retrospective monocenter study. Inclusion of every patient who underwent a CMR during a 15 months period with various clinical indication (congenital heart defect, myocarditis, cardiomyopathy). A minimum of three LV long-axis planes and a stack of short-axis slices covering the LV using classical steady-state free precession cine sequences. A single assessment of GLS on long axis (LAX) slices and a double assessment of GCS and EF with both short axis (SAX) and LAX slices were made by a single experienced CMR investigator. Results: GCS-SAX and GCS-LAX were correlated (r = 0.77, P < 0.001) without being interchangeable with a high reproducibility for GCS, GLS and EF. EF calculated from LAX images showed an overestimation compared to EF derived from SAX images of 7%. The correlation between calculated EF and theoretical EF derived from SI was high (r = 0.88 with EF-SAX, 0.95 with EF-LAX). Data conclusion: This study highlights the need to integrate strain imaging techniques into clinical by incorporating strain parameters into EF calculations, because it gives a deeper understanding of cardiac mechanics.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38490258

RESUMO

OBJECTIVES: Surgical management of mitral valve disease is challenging in infants <1 year old. We aimed at reviewing the French experience with Melody mitral valve replacement in critically ill infants. METHODS: A retrospective cohort study reporting the French experience with Melody mitral valve replacement. RESULTS: Seven symptomatic infants [complete atrioventricular septal defect (n = 4, Down syndrome: n = 3), hammock valve (n = 3)] underwent Melody mitral valve replacement [age: 3 months (28 days to 8 months), weight: 4.3 kg (3.2-6.4 kg)] because of severe mitral valve regurgitation (6) or mixed valve disease (1) and 14 mm (11-16 mm) mitral valve annulus. In 2 patients whose valve was felt irreparable, Melody mitral valve replacement was performed straightaway. The others underwent 2 (1-3) previous attempts of valve repair; 3 were on extracorporeal membrane oxygenation. Melody mitral valve replacement led to competent valve and low gradient [3 mmHg, (1-4 mmHg)]. One patient died 3 days post-implant from extracorporeal membrane oxygenation-related stroke. Of the 6 discharged home patients, 3 (50%) were readmitted for a definite diagnosis (1) or high suspicion (2) of infective endocarditis, of which 2 died. Over the follow-up, 1 underwent balloon expansions of the valve at 9- and 16-months post-implant, and mechanical mitral valve replacement at 2 years; another is currently planned for transcatheter Melody valve dilation. CONCLUSIONS: Melody mitral valve replacement may be considered in selected infants with small mitral valve annulus as an alternative to mechanical mitral valve replacement. Our experience highlights a high-risk of late infective endocarditis that deserves further consideration.

3.
Cardiol Young ; : 1-3, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38439635

RESUMO

Pulmonary atresia with ventricular septal defect, non-confluent pulmonary arteries, and bilateral arterial duct is a rare and complex CHD. Physiologic ductal closure may lead to life-threatening hypoxia. We present a case of successful bilateral ductal stenting as a bridge to further lower-risk surgical repair.

4.
Eur J Pediatr ; 183(5): 2193-2201, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38381375

RESUMO

Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence.          Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Recém-Nascido Prematuro , Complicações Pós-Operatórias , Humanos , Permeabilidade do Canal Arterial/cirurgia , Estudos Retrospectivos , Recém-Nascido , Feminino , Ligadura/métodos , Ligadura/efeitos adversos , Masculino , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Recém-Nascido de Baixo Peso , Incidência , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Síndrome , Pontuação de Propensão , Dispositivo para Oclusão Septal , Fatores de Risco , Doenças do Prematuro/cirurgia , Doenças do Prematuro/etiologia , Doenças do Prematuro/terapia , Doenças do Prematuro/epidemiologia
5.
Paediatr Drugs ; 26(1): 83-93, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978159

RESUMO

BACKGROUND: Patent ductus arteriosus (PDA) in preterm infants is associated with increased morbidities and mortality. Prophylactic treatment with cyclooxygenase inhibitors, as indomethacin or ibuprofen, failed to demonstrate significant clinical benefits. Acetaminophen may represent an alternative treatment option. OBJECTIVE: This study evaluated the minimum effective dose of prophylactic acetaminophen to close the ductus and assessed the safety and tolerability profile in extremely preterm infants at 23-26 weeks of gestation. METHODS: A dose finding trial with Bayesian continual reassessment method was performed in a multicenter study with premature infants hospitalized in neonatal intensive care unit. Infants of 23-26 weeks of gestation and post-natal age ≤ 12 h were enrolled. Four intravenous acetaminophen dose levels were predefined. The primary outcome was the ductus arteriosus closing at two consecutive echocardiographies or at day 7. The main secondary objectives included the safety of acetaminophen on hemodynamics and biological hepatic function. RESULTS: A total of 29 patients were analyzed sequentially for the primary analysis with 20 infants assigned to the first dose level followed by 9 infants to the second dose level. No further dose level increase was necessary. The posterior probabilities of success, estimated from the Bayesian logistic model, were 46.1% [95% probability interval (PI), 24.9-63.9] and 67.6% (95% PI, 51.5-77.9) for dose level 1 and 2, respectively. A closing or closed pattern was observed among 19 patients at the end of treatment [65.5% (95% confidence interval (CI), 45.7-82.0)]. No change in alanine aminotransferase values was observed during treatment. A significant decrease in aspartate aminotransferase values was observed with postnatal age. No change in systolic and diastolic blood pressures was observed during treatment. CONCLUSIONS: Minimum effective dose to close the ductus was 25 mg/kg loading dose then 10 mg/kg/6 h for 5 days in extremely preterm infants. Acetaminophen was well tolerated in this study following these doses. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04459117.


Assuntos
Acetaminofen , Permeabilidade do Canal Arterial , Humanos , Recém-Nascido , Acetaminofen/administração & dosagem , Acetaminofen/efeitos adversos , Teorema de Bayes , Permeabilidade do Canal Arterial/tratamento farmacológico , Ibuprofeno , Indometacina , Lactente Extremamente Prematuro
6.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38132644

RESUMO

Persistent patent ductus arteriosus is a very common condition in preterm infants. Although there is no management agreed by consensus, despite numerous randomized controlled trials, hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. Medical treatment is usually offered as first-line therapy, although it carries a limited success rate and potential severe adverse events. In recent years, transcatheter patent ductus arteriosus closure has fast developed and become widely accepted as a safe and efficient alternative to surgical ductal ligation in extremely low birth weight infants >700 g, using most often the dedicated Amplatzer Piccolo Occluder device. This article aims to provide an appraisal of the patients' selection process, and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.

7.
Arch Cardiovasc Dis ; 116(12): 580-589, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37951755

RESUMO

BACKGROUND: The Amplatzer™ Trevisio™ Intravascular Delivery System (Trevisio DS; Abbott Laboratories, Chicago, IL, USA) facilitates the delivery of Amplatzer™ Occluders and features an ultraflexible tip, which improves assessment of occluder position before release. AIMS: To assess the safety and efficacy of the Trevisio DS for transcatheter closure of patent foramen ovale and atrial septal defect. METHODS: The Amplatzer™ Trevisio™ Intravascular Delivery System Post-Approval Study was a prospective, postmarket, single-arm, multicentre, observational study of the Trevisio DS. Enrolled patients were indicated for transcatheter closure of patent foramen ovale or atrial septal defect. In all procedures, the Trevisio DS was used to deliver Amplatzer™ Occluders. Technical success was defined as successful deployment and release of at least one occluder. Device- or procedure-related serious adverse events were tracked until discharge or day 7, whichever occurred earlier. RESULTS: The study enrolled 144 patients with patent foramen ovale and 107 patients with atrial septal defect at 22 European sites; 53 patients with atrial septal defect (49.6%) were aged<18years. The rate of technical success was 98.4% (97.2% for atrial septal defect, 99.3% for patent foramen ovale). There was one serious adverse event (0.4%), an acute periprocedural device embolization that occurred after occluder release in a patient with atrial septal defect; the device was retrieved percutaneously. This was determined by the implanter to be unrelated to the performance of the Trevisio DS. CONCLUSIONS: The Trevisio DS exhibited a high rate of technical success and an excellent safety profile during transcatheter closure of patent foramen ovale and atrial septal defect.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Estudos Prospectivos , Cateterismo Cardíaco , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Resultado do Tratamento
8.
J Clin Med ; 12(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37959330

RESUMO

Technological advancements have greatly impacted the healthcare industry, including the integration of e-health in pediatric cardiology. The use of telemedicine, mobile health applications, and electronic health records have demonstrated a significant potential to improve patient outcomes, reduce healthcare costs, and enhance the quality of care. Telemedicine provides a useful tool for remote clinics, follow-up visits, and monitoring for infants with congenital heart disease, while mobile health applications enhance patient and parents' education, medication compliance, and in some instances, remote monitoring of vital signs. Despite the benefits of e-health, there are potential limitations and challenges, such as issues related to availability, cost-effectiveness, data privacy and security, and the potential ethical, legal, and social implications of e-health interventions. In this review, we aim to highlight the current application and perspectives of e-health in the field of fetal and neonatal cardiology, including expert parents' opinions.

9.
JACC Cardiovasc Interv ; 16(21): 2587-2599, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37855807

RESUMO

Superior sinus venosus defect is a communication between the right and left atrium located above the upper margin of the oval fossa, immediately inferior to the junction of the superior vena cava and the right atrium. It is systematically associated with partial anomalous pulmonary venous drainage, especially of the right upper pulmonary vein. Surgical repair has been the gold standard approach to close that defect. Introduced in 2014, percutaneous closure has gradually become a safe and effective alternative to surgery in carefully selected patients, although worldwide experience remains limited. This article provides an appraisal of the patients' selection process and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.


Assuntos
Comunicação Interatrial , Veias Pulmonares , Humanos , Veia Cava Superior/diagnóstico por imagem , Resultado do Tratamento , Comunicação Interatrial/terapia , Comunicação Interatrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades
10.
Cardiol Young ; 33(10): 2113-2115, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37139926

RESUMO

Device-induced aortic obstruction is a known rare complication following transcatheter closure of patent ductus arteriosus in extremely low-birth-weight infants. Various mechanisms have been proposed. We report the first description of late aortic obstruction due to ductal vasoconstriction on pulmonic end causing device to be gradually pushed out of aortic end in a 980-gram premature infant.


Assuntos
Permeabilidade do Canal Arterial , Recém-Nascido , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Vasoconstrição , Recém-Nascido Prematuro , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Aorta
11.
Cardiol Young ; 33(10): 2119-2121, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37114721

RESUMO

Therapeutic options are limited for the management of extremely low-birth-weight infants with critical aortic coarctation despite high doses of prostaglandin infusion. We report successful hybrid, fluoroscopy-free, echocardiography-guided primary stenting of native aortic coarctation in a 920-grams premature infant.


Assuntos
Coartação Aórtica , Recém-Nascido , Lactente , Humanos , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Recém-Nascido Prematuro , Ecocardiografia , Recém-Nascido de Peso Extremamente Baixo ao Nascer
12.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36864617

RESUMO

OBJECTIVES: The antiarrhythmic effects of dexmedetomidine (DEX) have been suggested, but there are controversial reports on the effectiveness of intraoperative use of DEX to reduce the incidence of postoperative tachyarrhythmia (POT). METHODS: From a local European Congenital Heart Surgery Association database, we included patients operated for congenital heart diseases under cardiopulmonary bypass within a 5-year period (2017-2021), during which intraoperative use of high dose of DEX (1-1.4 µg/kg/h) was implemented. A doubly robust matching estimation of the causal effect of DEX on the incidence of POT was conducted. We combined a multimodal estimation model in patients not exposed to DEX (disease risk score) as well as a regression analysis in a matched cohort for patients exposured to DEX. RESULTS: From a cohort of 593 surgeries (514 patients) occurring during the study period, doubly matched analysis consisted of the analysis of 426 surgeries conducted under DEX or not (213 per group). The probability of developing POT in patients exposed to DEX was 6.6% (95% confidence interval 0.032-0.099) vs 14.5% (95% confidence interval 0.098-0.193) in the group of patients not exposed to DEX. The doubly robust matched estimation method showed a mean reduction of 8.8% (95% confidence interval -0.137 to -0.023) of POT when DEX is used for intraoperative anaesthesia. CONCLUSIONS: The use of high doses of DEX during anaesthesia for congenital heart surgery in neonates and infants is associated with a moderate but significant reduction of POT.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Dexmedetomidina , Cardiopatias Congênitas , Recém-Nascido , Humanos , Lactente , Dexmedetomidina/uso terapêutico , Incidência , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Taquicardia/epidemiologia , Taquicardia/prevenção & controle , Taquicardia/induzido quimicamente , Cardiopatias Congênitas/cirurgia
13.
Cardiol Young ; 33(5): 793-794, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36756904

RESUMO

We report the exceptional case of transcatheter treatment of a partial anomalous pulmonary venous drainage of the right lung to the innominate vein and dual drainage to the left atrium.


Assuntos
Veias Pulmonares , Síndrome de Cimitarra , Humanos , Veias Pulmonares/anormalidades , Pulmão , Átrios do Coração/anormalidades , Drenagem
14.
Open Heart ; 10(1)2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36631173

RESUMO

OBJECTIVES: To evaluate bare-metal Optimus and polytetrafluoroethylene (PTFE)-covered Optimus-CVS balloon-expandable, cobalt-chromium, hybrid cell-designed stents in congenital heart disease (CHD) interventions. METHODS: Retrospective multicentre review of patients with CHD receiving Optimus stents. Stent mechanical behaviour, clinical indications and outcomes were assessed. RESULTS: 183 stents (49.2% XXL/15-ZIG, 33.3% XL/12-ZIG, 17.5% L/9-ZIG) were implanted (98.9% success rate, 2.3% serious procedural complication rate) in 170 patients (57.6% men, 64.1% adults), median age 23.6 years (IQR, 15.2-39.2) and weight 63.5 kg (IQR, 47-75.7). Indications were right ventricular outflow tract stand-alone stenting or before revalvulation (62.4%), aortic coarctation treatment (15.3%), Fontan-circuit fenestration closure (12.4%) and miscellaneous (10%). 86/170 (50.6%) patients had PTFE-covered stenting (50% prophylactic). In 86/170 (50.6%) patients with stenotic lesions, median percentage of achieved stent expansion was 93.4% (IQR, 85.5%-97.7%), median gradient decreased from 28 mm Hg (IQR, 19-41) to 5 mm Hg (IQR, 1-9) (p<0.001), median vessel diameters increased from 13 mm (IQR, 7.9-17) to 18.9 mm (IQR, 15.2-22) (p<0.001) and percentage of vessel expansion was 45.2% (IQR, 19.8%-91.3%). In 30/36 (83.3%) patients with graft, median dilation of 2 mm (IQR, 2-5) above nominal diameter was achieved. Median stent shortening was 10.9% (IQR, 6.1-15.1) and was associated only with expansion diameter (OR: 0.66, 95% CI: 0.38 to 0.93). No clinically relevant fracture, stent embolisation or dysfunction occurred on a median follow-up of 9 (IQR, 4-14) months. CONCLUSIONS: Optimus stents are effective tools for transcatheter treatment of simple and complex CHD. Optimus stents' reliable mechanical behaviour and particular covering design can promote widespread use.


Assuntos
Coartação Aórtica , Cardiopatias Congênitas , Adulto , Masculino , Humanos , Adulto Jovem , Feminino , Cromo , Cobalto , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Stents , Politetrafluoretileno
15.
Front Cardiovasc Med ; 10: 1332395, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38288053

RESUMO

Background: The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD). Objectives: The authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy. Methods: This is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged < 18 years with PH or cardiomyopathy needing AFR implantation were included. Results: A total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5-142.5) and the median weight was 17 kg (IQR: 10-46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125-593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened. Conclusions: AFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up.

16.
Circ Genom Precis Med ; 15(1): e003391, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35113648

RESUMO

BACKGROUND: Acquired long QT syndrome (aLQTS) is a serious unpredictable adverse drug reaction. Pharmacogenomic markers may predict risk. METHODS: Among 153 aLQTS patients (mean age 58 years [range, 14-88], 98.7% White, 85.6% symptomatic), computational methods identified proteins interacting most significantly with 216 QT-prolonging drugs. All cases underwent sequencing of 31 candidate genes arising from this analysis or associating with congenital LQTS. Variants were filtered using a minor allele frequency <1% and classified for susceptibility for aLQTS. Gene-burden analyses were then performed comparing the primary cohort to control exomes (n=452) and an independent replication aLQTS exome sequencing cohort. RESULTS: In 25.5% of cases, at least one rare variant was identified: 22.2% of cases carried a rare variant in a gene associated with congenital LQTS, and in 4% of cases that variant was known to be pathogenic or likely pathogenic for congenital LQTS; 7.8% cases carried a cytochrome-P450 (CYP) gene variant. Of 12 identified CYP variants, 11 (92%) were in an enzyme known to metabolize at least one culprit drug to which the subject had been exposed. Drug-drug interactions that affected culprit drug metabolism were found in 19% of cases. More than one congenital LQTS variant, CYP gene variant, or drug interaction was present in 7.8% of cases. Gene-burden analyses of the primary cohort compared to control exomes (n=452), and an independent replication aLQTS exome sequencing cohort (n=67) and drug-tolerant controls (n=148) demonstrated an increased burden of rare (minor allele frequency<0.01) variants in CYP genes but not LQTS genes. CONCLUSIONS: Rare susceptibility variants in CYP genes are emerging as potentially important pharmacogenomic risk markers for aLQTS and could form part of personalized medicine approaches in the future.


Assuntos
Predisposição Genética para Doença , Síndrome do QT Longo , Exoma/genética , Frequência do Gene , Testes Genéticos , Humanos , Síndrome do QT Longo/genética , Pessoa de Meia-Idade
17.
JACC Cardiovasc Imaging ; 15(2): 299-308, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34538632

RESUMO

OBJECTIVES: The aim of this study was to assess the diagnostic performances of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) in congenital heart disease (CHD) patients with pulmonary prosthetic valve or conduit endocarditis (PPVE) suspicion. BACKGROUND: PPVE is a major issue in the growing CHD population. Diagnosis is challenging, and usual imaging tools are not always efficient or validated in this specific population. Particularly, the diagnostic yield of 18F-FDG PET/CT remains poorly studied in PPVE. METHODS: A retrospective multicenter study was conducted in 8 French tertiary centers. Children and adult CHD patients who underwent 18F-FDG PET/CT in the setting of PPVE suspicion between January 2010 and May 2020 were included. The cases were initially classified as definite, possible, or rejected PPVE regarding the modified Duke criteria and finally by the Endocarditis Team consensus. The result of 18F-FDG PET/CT had been compared with final diagnosis consensus used as gold-standard in our study. RESULTS: A total of 66 cases of PPVE suspicion involving 59 patients (median age 23 years, 73% men) were included. Sensitivity, specificity, positive predictive value, and negative predictive value of 18F-FDG PET/CT in PPVE suspicion were respectively: 79.1% (95% CI: 68.4%-91.4%), 72.7% (95% CI: 60.4%-85.0%), 91.9% (95% CI: 79.6%-100.0%), and 47.1% (95% CI: 34.8%-59.4%). 18F-FDG PET/CT findings would help to correctly reclassify 57% (4 of 7) of possible PPVE to definite PPVE. CONCLUSIONS: Using 18F-FDG PET/CT improves the diagnostic accuracy of the Duke criteria in CHD patients with suspected PPVE. Its high positive predictive value could be helpful in routine to shorten diagnosis and treatment delays and improve clinical outcomes.


Assuntos
Endocardite , Próteses Valvulares Cardíacas , Valva Pulmonar , Adulto , Criança , Endocardite/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Adulto Jovem
18.
Pediatr Cardiol ; 43(2): 465-466, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34528131

RESUMO

Isoproterenol stress test during cardiac catheterization unmasked dynamic bulbo-ventricular foramen restriction in a 5-year-old boy with bidirectional Glenn anastomosis for tricuspid atresia/transposed great arteries and unexplained syncope.


Assuntos
Atresia Tricúspide , Anastomose Cirúrgica , Cateterismo Cardíaco , Pré-Escolar , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Isoproterenol , Masculino , Atresia Tricúspide/cirurgia
20.
Cardiol Young ; 31(10): 1557-1562, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34551835

RESUMO

The long-term prospective multi-centre nationwide (French) observational study FRANCISCO will provide new information on perimembranous ventricular septal defect with left ventricular overload but no pulmonary hypertension in children older than 1 year. Outcomes will be compared according to treatment strategy (watchful waiting, surgical closure, or percutaneous closure) and anatomic features of the defect. The results are expected to provide additional guidance about the optimal treatment of this specific population, which is unclear at present. BACKGROUND: The management of paediatric isolated perimembranous ventricular septal defect (pmVSD) with left ventricle (LV) volume overload but no pulmonary arterial hypertension (PAH) remains controversial. Three therapeutic approaches are considered: watchful waiting, surgical closure, and percutaneous closure. We aim to investigate the long-term outcomes of these patients according to anatomic pmVSD characteristics and treatment strategy. METHODS: The Filiale de Cardiologie Pediatrique et Congénitale (FCPC) designed the FRANCISCO registry, a long-term prospective nationwide multi-centre observational cohort study sponsored by the French Society of Cardiology, which enrolled, over 2 years (2018­2020), patients older than 1 year who had isolated pmVSD with LV volume overload. Prevalent complications related to pmVSD at baseline were exclusion criteria. Clinical, echocardiographic, and functional data will be collected at inclusion then after 1, 5, and 10 years. A core lab will analyse all baseline echocardiographic data to depict anatomical pmVSD features. The primary outcome is the 5-year incidence of cardiovascular events (infective endocarditis, sub-aortic stenosis, aortic regurgitation, right ventricular outflow tract stenosis, tricuspid regurgitation, PAH, arrhythmia, stroke, haemolysis, heart failure, or death from a cardiovascular event). We plan to enrol 200 patients, given the 10% estimated 5-year incidence of cardiovascular events with a 95% confidence interval of ±5%. Associations linking anatomical pmVSD features and treatment strategy to the incidence of complications will be assessed. CONCLUSIONS: The FRANSCICO study will provide the long-term incidence of complications in patients older than 1 year with pmVSD and LV volume overload. The results are expected to improve guidance for treatment decisions.


Assuntos
Insuficiência Cardíaca , Comunicação Interventricular , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Criança , Pré-Escolar , Comunicação Interventricular/epidemiologia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estudos Observacionais como Assunto , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA