Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Medicina (Ribeirao Preto, Online) ; 56(4)dez. 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1538285

RESUMO

Introduction: The change in handgrip strength (HGS) is an indicator of the emergence of some chronic diseases, such as diabetes mellitus (DM) and systemic arterial hypertension (SAH). Objective: Analyze the relationship between HGS and body composition and laboratory indicators of diabetic and hypertensive patients assisted in Primary Health Care. Methods: The sample consisted of 185 users of a Basic Health Unit in the city of Santarém, Pará, distributed into two groups: control (CTL) ­ users without a diagnosis of DM and/or SAH (n=66); and DM/SAH (n=119) ­ users with DM or SAH or both diseases. Data collection involved sociodemographic, clinical, anthropometric, biochemical, and HGS information. Data were analyzed using descriptive and inferential statistics, adopting p<0.05. Results: It was noted that low HGS in the DM/SAH group was associated with high values of body mass index, abdominal circumference, fat percentage, fat mass, total cholesterol, and triglycerides and with more factors for metabolic syndrome (p<0.05). The CTL group, in relation to DM/SAH for the same HGS classification, demonstrated significance for lower blood pressure values, body mass index, abdominal circumference, fat percentage, and fat mass, as well as a lower chance of developing metabolic syndrome (p<0.05). Conclusion: According to the study proposal, it is concluded that the evaluation and follow-up of HGS in individuals with chronic diseases, especially DM and SAH, is relevant to monitor body adiposity and dyslipidemia and avoid the aggravation of existing diseases or the emergence of new ones (AU).


Introdução: A alteração na força de preensão (FP) manual é indicador para surgimento de algumas doenças crônicas, como a diabetes mellitus (DM) e hipertensão arterial sistêmica (HAS). Objetivo: Analisar a relação da FP com a composição corporal e indicadores laboratoriais de diabéticos e hipertensos assistidos na Atenção Primária à Saúde. Métodos: A amostra foi composta por 185 usuários de uma Unidade Básica de Saúde na cidade de Santarém, Pará, sendo distribuídos em dois grupos: controle (CTL) ­ usuários sem o diagnóstico para DM e/ou HAS (n=66); e DM/HAS (n=119) ­ usuários com DM ou HAS ou as duas doenças. A coleta de dados envolveu informações sócio-demográficas, clínicas, antropométricas, bioquímicas e FP. Os dados foram analisados por estatística descritiva e inferencial, adotando-se p<0,05. Resultados: Notou-se que a FP baixa no grupo DM/HAS apresentou associação com valores elevados do índice de massa corporal, circunferência abdominal, percentual de gordura, massa gorda, colesterol total, triglicerídeos e com mais fatores para a síndrome metabólica (p<0,05). Já o grupo CTL, em rela-ção do DM/HAS para uma mesma classificação de FP, demonstrou significância para menores valores pressóricos, do índice de massa corporal, da circunferência abdominal, percentual de gordura, massa gorda, bem como menor chance para o desenvolvimento da síndrome metabólica (p<0,05). Conclusão: Conclui-se, conforme a proposta do estudo, que é relevante a avaliação e acompanhamento da FP em indivíduos com doenças crônicas, em especial a DM e a HAS, a fim de monitorar a adiposidade corporal e a dislipidemia, evitando o agravo das doenças instaladas ou o surgimento de novas (AU).


Assuntos
Humanos , Força da Mão , Diabetes Mellitus , Hipertensão
2.
Photodiagnosis Photodyn Ther ; 31: 101947, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32768587

RESUMO

Porphyrins are photoactive compounds that can absorb the energy of light and transfer it to oxygen molecules, producing reactive oxygen species (ROS). Once produced, ROS may alter biological molecules and cellular mechanisms, leading to cell apoptosis or inactivation of microorganisms, such as bacteria, fungi, and viruses. Therefore, the objective of this study was to evaluate the in vitro virucidal activity of six tetra-cationic porphyrins against two bovine viruses (Bovine alphaherpesvirus 1, BoHV-1, enveloped; and Bovine adenovirus, BAV, non-enveloped). For this, viral suspensions were incubated with each porphyrin (H2TMeP, ZnTMeP, and CuTMeP at 4.0 µM, NiTMeP at 5.0 µM, and CoClTMeP and MnClTMeP at 1.0 µM) and exposed to white-light irradiation for 0, 60, 120, and 180 min (BAV) or 0, 30, 60, 90, and 120 min (BoHV-1). Then, the remaining viral titers were determined by limiting dilution and compared with the control (virus + porphyrins without light exposition). The porphyrins H2TMeP and ZnTMeP showed the highest virucidal activity against both viruses. ZnTMeP inactivated BoHV-1 after 30 min of photoactivation and H2TMeP after 60 min. The BAV was photo-inactivated by both porphyrins at 180 min of white-light exposition. CuTMeP, NiTMeP, and CoClTMeP porphyrins had weak virucidal activity against BoHV-1 and MnClTMeP showed no virucidal activity against both viruses. These results indicated that free-base H2TMeP and ZnTMeP porphyrins present virucidal activity against non-enveloped and enveloped viruses, opening the possibility for their use to inactivate viruses on surfaces, biological substrates, and solutions.


Assuntos
Fotoquimioterapia , Porfirinas , Adenoviridae , Animais , Bovinos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Porfirinas/farmacologia , Água
3.
Braz. j. otorhinolaryngol. (Impr.) ; 81(5): 479-484, Sept.-Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-766299

RESUMO

ABSTRACT INTRODUCTION: To attain an accurate otoscopic diagnosis, a functioning device with adequate capacity must be used. OBJECTIVE: Evaluate the light intensity of otoscopes, comparing it utilizing the batteries present at the moment of calibration and after new batteries were supplied. METHODS: Cross-sectional study of a historical cohort, which assessed 38 otoscopes, measuring the light intensity with the batteries present at the moment of assessment compared to the intensity with new batteries, as well as charge of the test batteries and the new batteries. RESULTS: The mean of the sum of new batteries' charge was 3.19 V, and of the test batteries was 2.70 V, representing a decrease of 18.02% in charge. The mean luminosity with the new batteries was 366.89 lumens, whereas in the test batteries it was 188.32 lumens, representing a decrease of 83.75% in the light intensity. Student's t-test was applied for data comparison, showing a statistical difference between the light intensity with the original batteries and the new batteries (p = 0.0001; CI = 0.95). CONCLUSION: There was a statistically significant difference between the proportions of light intensity in the otoscopes. A small variation in battery charge results in a great variation in light.


RESUMO Introdução: Para a realização de um diagnóstico otoscópico preciso deve-se utilizar um aparelho funcionando com uma capacidade adequada. Objetivo: Avaliar a intensidade luminosa dos otoscópios comparando a intensidade da luz comas pilhas encontradas no momento da aferição e com pilhas novas. Método: Estudo de coorte histórica com corte transversal, onde foram analisados 38 otoscópios, sendo realizada a aferição da qualidade luminosa com a pilha utilizada e comparado com uma pilha nova, e a aferição da carga das pilhas novas e em utilização no momento do exame. Resultados: A média da soma das cargas das pilhas novas foi de 3,19 V, e a das pilhas testes foi de 2,70 V, representando decréscimo de 18,02% na carga das pilhas. A média da luminosidade comas pilhas novas foi de 366.89 lúmens, e com a pilha teste foi de 188.32 lúmens, representando decréscimo de 83,75% na intensidade luminosa. Foi aplicado o teste T para comparação entre os dados, onde percebe-se diferença estatística entre a intensidade luminosa com pilhas testes e novas (p = 0,0000; IC = 0,95). Conclusão: Houve diferença estatisticamente significativa entre a proporção de intensidade da luz dos otoscópios. Uma pequena variação da pilha proporciona uma grande variação na luz.


Assuntos
Humanos , Fontes de Energia Elétrica/normas , Iluminação/normas , Otoscópios/normas , Otoscopia/normas , Estudos Transversais , Fontes de Energia Elétrica/estatística & dados numéricos , Hospitais de Ensino
4.
Braz J Otorhinolaryngol ; 81(5): 479-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26277834

RESUMO

INTRODUCTION: To attain an accurate otoscopic diagnosis, a functioning device with adequate capacity must be used. OBJECTIVE: Evaluate the light intensity of otoscopes, comparing it utilizing the batteries present at the moment of calibration and after new batteries were supplied. METHODS: Cross-sectional study of a historical cohort, which assessed 38 otoscopes, measuring the light intensity with the batteries present at the moment of assessment compared to the intensity with new batteries, as well as charge of the test batteries and the new batteries. RESULTS: The mean of the sum of new batteries' charge was 3.19V, and of the test batteries was 2.70V, representing a decrease of 18.02% in charge. The mean luminosity with the new batteries was 366.89lumens, whereas in the test batteries it was 188.32lumens, representing a decrease of 83.75% in the light intensity. Student's t-test was applied for data comparison, showing a statistical difference between the light intensity with the original batteries and the new batteries (p=0.0001; CI=0.95). CONCLUSION: There was a statistically significant difference between the proportions of light intensity in the otoscopes. A small variation in battery charge results in a great variation in light.


Assuntos
Fontes de Energia Elétrica/normas , Iluminação/normas , Otoscópios/normas , Otoscopia/normas , Estudos Transversais , Fontes de Energia Elétrica/estatística & dados numéricos , Hospitais de Ensino , Humanos