Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 7956, 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38042952

RESUMO

Serial crystallography at X-ray free-electron lasers (XFELs) permits the determination of radiation-damage free static as well as time-resolved protein structures at room temperature. Efficient sample delivery is a key factor for such experiments. Here, we describe a multi-reservoir, high viscosity extruder as a step towards automation of sample delivery at XFELs. Compared to a standard single extruder, sample exchange time was halved and the workload of users was greatly reduced. In-built temperature control of samples facilitated optimal extrusion and supported sample stability. After commissioning the device with lysozyme crystals, we collected time-resolved data using crystals of a membrane-bound, light-driven sodium pump. Static data were also collected from the soluble protein tubulin that was soaked with a series of small molecule drugs. Using these data, we identify low occupancy (as little as 30%) ligands using a minimal amount of data from a serial crystallography experiment, a result that could be exploited for structure-based drug design.


Assuntos
Elétrons , Proteínas , Cristalografia , Cristalografia por Raios X , Proteínas/química , Síncrotrons , Lasers
2.
Science ; 382(6674): 1015-1020, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38033070

RESUMO

Photolyase is an enzyme that uses light to catalyze DNA repair. To capture the reaction intermediates involved in the enzyme's catalytic cycle, we conducted a time-resolved crystallography experiment. We found that photolyase traps the excited state of the active cofactor, flavin adenine dinucleotide (FAD), in a highly bent geometry. This excited state performs electron transfer to damaged DNA, inducing repair. We show that the repair reaction, which involves the lysis of two covalent bonds, occurs through a single-bond intermediate. The transformation of the substrate into product crowds the active site and disrupts hydrogen bonds with the enzyme, resulting in stepwise product release, with the 3' thymine ejected first, followed by the 5' base.


Assuntos
Desoxirribodipirimidina Fotoliase , Cristalografia , Desoxirribodipirimidina Fotoliase/química , Desoxirribodipirimidina Fotoliase/metabolismo , Reparo do DNA , Dano ao DNA , Transporte de Elétrons
3.
IUCrJ ; 10(Pt 6): 678-693, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37727961

RESUMO

Fixed targets are a popular form of sample-delivery system used in serial crystallography at synchrotron and X-ray free-electron laser sources. They offer a wide range of sample-preparation options and are generally easy to use. The supports are typically made from silicon, quartz or polymer. Of these, currently, only silicon offers the ability to perform an aperture-aligned data collection where crystals are loaded into cavities in precise locations and sequentially rastered through, in step with the X-ray pulses. The polymer-based fixed targets have lacked the precision fabrication to enable this data-collection strategy and have been limited to directed-raster scans with crystals randomly distributed across the polymer surface. Here, the fabrication and first results from a new polymer-based fixed target, the micro-structured polymer fixed targets (MISP chips), are presented. MISP chips, like those made from silicon, have a precise array of cavities and fiducial markers. They consist of a structured polymer membrane and a stabilization frame. Crystals can be loaded into the cavities and the excess crystallization solution removed through apertures at their base. The fiducial markers allow for a rapid calculation of the aperture locations. The chips have a low X-ray background and, since they are optically transparent, also allow for an a priori analysis of crystal locations. This location mapping could, ultimately, optimize hit rates towards 100%. A black version of the MISP chip was produced to reduce light contamination for optical-pump/X-ray probe experiments. A study of the loading properties of the chips reveals that these types of fixed targets are best optimized for crystals of the order of 25 µm, but quality data can be collected from crystals as small as 5 µm. With the development of these chips, it has been proved that polymer-based fixed targets can be made with the precision required for aperture-alignment-based data-collection strategies. Further work can now be directed towards more cost-effective mass fabrication to make their use more sustainable for serial crystallography facilities and users.

4.
Acta Crystallogr D Struct Biol ; 79(Pt 8): 668-672, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37463110

RESUMO

Fixed-target crystallography has become a widely used approach for serial crystallography at both synchrotron and X-ray free-electron laser (XFEL) sources. A plethora of fixed targets have been developed at different facilities and by various manufacturers, with different characteristics and dimensions and with little or no emphasis on standardization. These many fixed targets have good reasons for their design, shapes, fabrication materials and the presence or absence of apertures and fiducials, reflecting the diversity of serial experiments. Given this, it would be a Sisyphean task to design and manufacture a new standard fixed target that would satisfy all possible experimental configurations. Therefore, a simple standardized descriptor to fully describe fixed targets is proposed rather than a standardized device. This descriptor is a dictionary that could be read by fixed-target beamline software and straightforwardly allow data collection from fixed targets new to that beamline. The descriptor would therefore allow a much easier exchange of fixed targets between sources and facilitate the uptake of new fixed targets, benefiting beamlines, users and manufacturers. This descriptor was first presented at, and was developed following, a meeting of representatives from multiple synchrotron and XFEL sources in Hamburg in January 2023.


Assuntos
Software , Síncrotrons , Cristalografia por Raios X , Coleta de Dados , Lasers
5.
Nat Commun ; 14(1): 903, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36807348

RESUMO

The binding and release of ligands from their protein targets is central to fundamental biological processes as well as to drug discovery. Photopharmacology introduces chemical triggers that allow the changing of ligand affinities and thus biological activity by light. Insight into the molecular mechanisms of photopharmacology is largely missing because the relevant transitions during the light-triggered reaction cannot be resolved by conventional structural biology. Using time-resolved serial crystallography at a synchrotron and X-ray free-electron laser, we capture the release of the anti-cancer compound azo-combretastatin A4 and the resulting conformational changes in tubulin. Nine structural snapshots from 1 ns to 100 ms complemented by simulations show how cis-to-trans isomerization of the azobenzene bond leads to a switch in ligand affinity, opening of an exit channel, and collapse of the binding pocket upon ligand release. The resulting global backbone rearrangements are related to the action mechanism of microtubule-destabilizing drugs.


Assuntos
Microtúbulos , Tubulina (Proteína) , Tubulina (Proteína)/metabolismo , Cristalografia , Ligantes , Microtúbulos/metabolismo , Cristalografia por Raios X
6.
IUCrJ ; 9(Pt 5): 610-624, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36071813

RESUMO

Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.

7.
Sci Total Environ ; 849: 157826, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-35932859

RESUMO

Rivers are dynamic landscape features that change in response to natural and anthropogenic factors through hydrological, geomorphic and ecological processes. The severity and magnitude of human impacts on river system and riparian vegetation has dramatically increased over the last century with the proliferation of valley-spanning dams, intensification of agriculture, urbanization, and more widespread channel engineering. This study aims to determine how changes in geomorphic form and dynamics caused by these human alterations relate to changes in channels and riparian vegetation in the lower Beas and Sutlej Rivers. These rivers are tributaries of the Indus that drain the Western Himalayas but differ in the type and magnitude of geomorphic change in recent decades. Winter season vegetation was analysed over 30 years, revealing increasing trends in vegetated land cover in the valleys of both rivers, consistent with large-scale drivers of change. Greater trends within the active channels indicate upstream drivers are influencing river flow and geomorphology, vegetation growth and human exploitation. The spatial patterns of vegetation change differ between the rivers, emphasizing how upstream human activities (dams and abstraction) control geomorphic and vegetation community response within the landscape context of the river. The increasing area of vegetated land is reinforcing the local evolutionary trajectory of the river planform from wide-braided wandering to single thread meandering. Narrowing of the active channels is altering the balance of resource provision and risk exposure to people. New areas being exploited for agriculture are exposed to greater risk from river erosion, inundation, and sediment deposition. Moreover, the change from braided to meandering planform has concentrated erosion on riverbanks, placing communities and infrastructure at risk. By quantifying and evaluating the spatial variations in vegetation cover around these rivers, we can better understand the interaction of vegetation and geomorphology alongside the impacts of human activity and climate change in these, and many similar, large systems, which can inform sustainable development.


Assuntos
Hidrologia , Rios , Agricultura , Mudança Climática , Ecossistema , Humanos , Urbanização
8.
Acta Crystallogr D Struct Biol ; 78(Pt 8): 964-974, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916221

RESUMO

Continuous developments in cryogenic X-ray crystallography have provided most of our knowledge of 3D protein structures, which has recently been further augmented by revolutionary advances in cryoEM. However, a single structural conformation identified at cryogenic temperatures may introduce a fictitious structure as a result of cryogenic cooling artefacts, limiting the overview of inherent protein physiological dynamics, which play a critical role in the biological functions of proteins. Here, a room-temperature X-ray crystallographic method using temperature as a trigger to record movie-like structural snapshots has been developed. The method has been used to show how TL00150, a 175.15 Da fragment, undergoes binding-mode changes in endothiapepsin. A surprising fragment-binding discrepancy was observed between the cryo-cooled and physiological temperature structures, and multiple binding poses and their interplay with DMSO were captured. The observations here open up new promising prospects for structure determination and interpretation at physiological temperatures with implications for structure-based drug discovery.


Assuntos
Proteínas , Ácido Aspártico Endopeptidases , Cristalografia por Raios X , Ligantes , Substâncias Macromoleculares , Proteínas/química , Temperatura
9.
Acta Crystallogr D Struct Biol ; 77(Pt 9): 1153-1167, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34473086

RESUMO

Serial data collection has emerged as a major tool for data collection at state-of-the-art light sources, such as microfocus beamlines at synchrotrons and X-ray free-electron lasers. Challenging targets, characterized by small crystal sizes, weak diffraction and stringent dose limits, benefit most from these methods. Here, the use of a thin support made of a polymer-based membrane for performing serial data collection or screening experiments is demonstrated. It is shown that these supports are suitable for a wide range of protein crystals suspended in liquids. The supports have also proved to be applicable to challenging cases such as membrane proteins growing in the sponge phase. The sample-deposition method is simple and robust, as well as flexible and adaptable to a variety of cases. It results in an optimally thin specimen providing low background while maintaining minute amounts of mother liquor around the crystals. The 2 × 2 mm area enables the deposition of up to several microlitres of liquid. Imaging and visualization of the crystals are straightforward on the highly transparent membrane. Thanks to their affordable fabrication, these supports have the potential to become an attractive option for serial experiments at synchrotrons and free-electron lasers.


Assuntos
Cristalografia por Raios X/métodos , Substâncias Macromoleculares/química , Proteínas/química , Coleta de Dados
10.
Nat Commun ; 12(1): 4461, 2021 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294694

RESUMO

Serial femtosecond crystallography has opened up many new opportunities in structural biology. In recent years, several approaches employing light-inducible systems have emerged to enable time-resolved experiments that reveal protein dynamics at high atomic and temporal resolutions. However, very few enzymes are light-dependent, whereas macromolecules requiring ligand diffusion into an active site are ubiquitous. In this work we present a drop-on-drop sample delivery system that enables the study of enzyme-catalyzed reactions in microcrystal slurries. The system delivers ligand solutions in bursts of multiple picoliter-sized drops on top of a larger crystal-containing drop inducing turbulent mixing and transports the mixture to the X-ray interaction region with temporal resolution. We demonstrate mixing using fluorescent dyes, numerical simulations and time-resolved serial femtosecond crystallography, which show rapid ligand diffusion through microdroplets. The drop-on-drop method has the potential to be widely applicable to serial crystallography studies, particularly of enzyme reactions with small molecule substrates.


Assuntos
Cristalografia por Raios X/métodos , Enzimas/química , Enzimas/metabolismo , Animais , Proteínas Aviárias/química , Proteínas Aviárias/metabolismo , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Biocatálise , Domínio Catalítico , Galinhas , Cristalografia por Raios X/instrumentação , Desenho de Equipamento , Modelos Moleculares , Muramidase/química , Muramidase/metabolismo , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , beta-Lactamases/química , beta-Lactamases/metabolismo
11.
J Vis Exp ; (168)2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33616091

RESUMO

Here, a protocol is presented to facilitate the creation of large volumes (> 100 µL) of micro-crystalline slurries suitable for serial crystallography experiments at both synchrotrons and XFELs. The method is based upon an understanding of the protein crystal phase diagram, and how that knowledge can be utilized. The method is divided into three stages: (1) optimizing crystal morphology, (2) transitioning to batch, and (3) scaling. Stage 1 involves finding well diffracting, single crystals, hopefully but not necessarily, presenting in a cube-like morphology. In Stage 2, the Stage 1 condition is optimized by crystal growth time. This strategy can transform crystals grown by vapor diffusion to batch. Once crystal growth can occur within approximately 24 h, a morphogram of the protein and precipitant mixture can be plotted and used as the basis for a scaling strategy (Stage 3). When crystals can be grown in batch, scaling can be attempted, and the crystal size and concentration optimized as the volume is increased. Endothiapepsin has been used as a demonstration protein for this protocol. Some of the decisions presented are specific to endothiapepsin. However, it is hoped that the way they have been applied will inspire a way of thinking about this procedure that others can adapt to their own projects.


Assuntos
Ascomicetos/enzimologia , Ácido Aspártico Endopeptidases/química , Cristalografia por Raios X/métodos , Cristalografia por Raios X/normas , Proteínas Fúngicas/química , Cristalização
12.
IUCrJ ; 7(Pt 5): 901-912, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32939282

RESUMO

Cryogenic X-ray diffraction is a powerful tool for crystallographic studies on enzymes including oxygenases and oxidases. Amongst the benefits that cryo-conditions (usually employing a nitro-gen cryo-stream at 100 K) enable, is data collection of di-oxy-gen-sensitive samples. Although not strictly anaerobic, at low temperatures the vitreous ice conditions severely restrict O2 diffusion into and/or through the protein crystal. Cryo-conditions limit chemical reactivity, including reactions that require significant conformational changes. By contrast, data collection at room temperature imposes fewer restrictions on diffusion and reactivity; room-temperature serial methods are thus becoming common at synchrotrons and XFELs. However, maintaining an anaerobic environment for di-oxy-gen-dependent enzymes has not been explored for serial room-temperature data collection at synchrotron light sources. This work describes a methodology that employs an adaptation of the 'sheet-on-sheet' sample mount, which is suitable for the low-dose room-temperature data collection of anaerobic samples at synchrotron light sources. The method is characterized by easy sample preparation in an anaerobic glovebox, gentle handling of crystals, low sample consumption and preservation of a localized anaerobic environment over the timescale of the experiment (<5 min). The utility of the method is highlighted by studies with three X-ray-radiation-sensitive Fe(II)-containing model enzymes: the 2-oxoglutarate-dependent l-arginine hy-droxy-lase VioC and the DNA repair enzyme AlkB, as well as the oxidase isopenicillin N synthase (IPNS), which is involved in the biosynthesis of all penicillin and cephalosporin antibiotics.

13.
J Biol Chem ; 295(39): 13488-13501, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32723869

RESUMO

Since the advent of protein crystallography, atomic-level macromolecular structures have provided a basis to understand biological function. Enzymologists use detailed structural insights on ligand coordination, interatomic distances, and positioning of catalytic amino acids to rationalize the underlying electronic reaction mechanisms. Often the proteins in question catalyze redox reactions using metal cofactors that are explicitly intertwined with their function. In these cases, the exact nature of the coordination sphere and the oxidation state of the metal is of utmost importance. Unfortunately, the redox-active nature of metal cofactors makes them especially susceptible to photoreduction, meaning that information obtained by photoreducing X-ray sources about the environment of the cofactor is the least trustworthy part of the structure. In this work we directly compare the kinetics of photoreduction of six different heme protein crystal species by X-ray radiation. We show that a dose of ∼40 kilograys already yields 50% ferrous iron in a heme protein crystal. We also demonstrate that the kinetics of photoreduction are completely independent from variables unique to the different samples tested. The photoreduction-induced structural rearrangements around the metal cofactors have to be considered when biochemical data of ferric proteins are rationalized by constraints derived from crystal structures of reduced enzymes.


Assuntos
Compostos Férricos/química , Heme/química , Metaloproteínas/química , Metamioglobina/química , Peroxidase/química , Animais , Sítios de Ligação , Cristalografia por Raios X , Cavalos , Cinética , Klebsiella pneumoniae/enzimologia , Modelos Moleculares , Oxirredução , Peroxidase/metabolismo , Processos Fotoquímicos , Raios X
14.
Acta Crystallogr D Struct Biol ; 76(Pt 5): 400-405, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32355036

RESUMO

The number of new X-ray crystallography-based submissions to the Protein Data Bank appears to be at the beginning of a decline, perhaps signalling an end to the era of the dominance of X-ray crystallography within structural biology. This letter, from the viewpoint of a young structural biologist, applies the Copernican method to the life expectancy of crystallography and asks whether the technique is still the mainstay of structural biology. A study of the rate of Protein Data Bank depositions allows a more nuanced analysis of the fortunes of macromolecular X-ray crystallography and shows that cryo-electron microscopy might now be outcompeting crystallography for new labour and talent, perhaps heralding a change in the landscape of the field.


Assuntos
Microscopia Crioeletrônica/tendências , Cristalografia por Raios X/tendências , Proteínas/química , Bases de Dados de Proteínas/tendências , Complexos Multiproteicos/química , Conformação Proteica
15.
J Appl Crystallogr ; 52(Pt 6): 1385-1396, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31798361

RESUMO

Serial crystallography, at both synchrotron and X-ray free-electron laser light sources, is becoming increasingly popular. However, the tools in the majority of crystallization laboratories are focused on producing large single crystals by vapour diffusion that fit the cryo-cooled paradigm of modern synchrotron crystallography. This paper presents several case studies and some ideas and strategies on how to perform the conversion from a single crystal grown by vapour diffusion to the many thousands of micro-crystals required for modern serial crystallography grown by batch crystallization. These case studies aim to show (i) how vapour diffusion conditions can be converted into batch by optimizing the length of time crystals take to appear; (ii) how an understanding of the crystallization phase diagram can act as a guide when designing batch crystallization protocols; and (iii) an accessible methodology when attempting to scale batch conditions to larger volumes. These methods are needed to minimize the sample preparation gap between standard rotation crystallography and dedicated serial laboratories, ultimately making serial crystallography more accessible to all crystallographers.

16.
IUCrJ ; 6(Pt 6): 1074-1085, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31709063

RESUMO

High-throughput X-ray crystal structures of protein-ligand complexes are critical to pharmaceutical drug development. However, cryocooling of crystals and X-ray radiation damage may distort the observed ligand binding. Serial femtosecond crystallography (SFX) using X-ray free-electron lasers (XFELs) can produce radiation-damage-free room-temperature structures. Ligand-binding studies using SFX have received only modest attention, partly owing to limited beamtime availability and the large quantity of sample that is required per structure determination. Here, a high-throughput approach to determine room-temperature damage-free structures with excellent sample and time efficiency is demonstrated, allowing complexes to be characterized rapidly and without prohibitive sample requirements. This yields high-quality difference density maps allowing unambiguous ligand placement. Crucially, it is demonstrated that ligands similar in size or smaller than those used in fragment-based drug design may be clearly identified in data sets obtained from <1000 diffraction images. This efficiency in both sample and XFEL beamtime opens the door to true high-throughput screening of protein-ligand complexes using SFX.

17.
J Synchrotron Radiat ; 26(Pt 5): 1820-1825, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490175

RESUMO

Efficient sample delivery is an essential aspect of serial crystallography at both synchrotrons and X-ray free-electron lasers. Rastering fixed target chips through the X-ray beam is an efficient method for serial delivery from the perspectives of both sample consumption and beam time usage. Here, an approach for loading fixed targets using acoustic drop ejection is presented that does not compromise crystal quality, can reduce sample consumption by more than an order of magnitude and allows serial diffraction to be collected from a larger proportion of the crystals in the slurry.

18.
IUCrJ ; 6(Pt 4): 543-551, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31316799

RESUMO

An approach is demonstrated to obtain, in a sample- and time-efficient manner, multiple dose-resolved crystal structures from room-temperature protein microcrystals using identical fixed-target supports at both synchrotrons and X-ray free-electron lasers (XFELs). This approach allows direct comparison of dose-resolved serial synchrotron and damage-free XFEL serial femtosecond crystallography structures of radiation-sensitive proteins. Specifically, serial synchrotron structures of a heme peroxidase enzyme reveal that X-ray induced changes occur at far lower doses than those at which diffraction quality is compromised (the Garman limit), consistent with previous studies on the reduction of heme proteins by low X-ray doses. In these structures, a functionally relevant bond length is shown to vary rapidly as a function of absorbed dose, with all room-temperature synchrotron structures exhibiting linear deformation of the active site compared with the XFEL structure. It is demonstrated that extrapolation of dose-dependent synchrotron structures to zero dose can closely approximate the damage-free XFEL structure. This approach is widely applicable to any protein where the crystal structure is altered by the synchrotron X-ray beam and provides a solution to the urgent requirement to determine intact structures of such proteins in a high-throughput and accessible manner.

19.
Acta Crystallogr D Struct Biol ; 75(Pt 3): 242-261, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30950396

RESUMO

Strategies for collecting X-ray diffraction data have evolved alongside beamline hardware and detector developments. The traditional approaches for diffraction data collection have emphasised collecting data from noisy integrating detectors (i.e. film, image plates and CCD detectors). With fast pixel array detectors on stable beamlines, the limiting factor becomes the sample lifetime, and the question becomes one of how to expend the photons that your sample can diffract, i.e. as a smaller number of stronger measurements or a larger number of weaker data. This parameter space is explored via experiment and synthetic data treatment and advice is derived on how best to use the equipment on a modern beamline. Suggestions are also made on how to acquire data in a conservative manner if very little is known about the sample lifetime.


Assuntos
Fótons , Difração de Raios X/métodos , Análise de Dados , Coleta de Dados
20.
Acta Crystallogr D Struct Biol ; 75(Pt 2): 151-159, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30821704

RESUMO

The ability to determine high-quality, artefact-free structures is a challenge in micro-crystallography, and the rapid onset of radiation damage and requirement for a high-brilliance X-ray beam mean that a multi-crystal approach is essential. However, the combination of crystal-to-crystal variation and X-ray-induced changes can make the formation of a final complete data set challenging; this is particularly true in the case of metalloproteins, where X-ray-induced changes occur rapidly and at the active site. An approach is described that allows the resolution, separation and structure determination of crystal polymorphs, and the tracking of radiation damage in microcrystals. Within the microcrystal population of copper nitrite reductase, two polymorphs with different unit-cell sizes were successfully separated to determine two independent structures, and an X-ray-driven change between these polymorphs was followed. This was achieved through the determination of multiple serial structures from microcrystals using a high-throughput high-speed fixed-target approach coupled with robust data processing.


Assuntos
Achromobacter cycloclastes/enzimologia , Cristalografia por Raios X/instrumentação , Nitrito Redutases/química , Síncrotrons/instrumentação , Achromobacter cycloclastes/química , Animais , Cristalização/instrumentação , Cristalização/métodos , Cristalografia por Raios X/métodos , Coleta de Dados/instrumentação , Coleta de Dados/métodos , Desenho de Equipamento , Humanos , Metaloproteínas/química , Conformação Proteica/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA