Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 52(5): 650-656, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27614555

RESUMO

OBJECTIVE: Near-infrared spectroscopy (NIRS) non-invasively determines tissue oxygen saturation (Sto2) in muscle tissue. Its application to monitor real time hemodynamic changes during percutaneous transluminal angioplasty (PTA) and Sto2 changes in feet 4 weeks after PTA was evaluated. METHODS: This study included 14 patients with critical limb ischemia (CLI, six patients Rutherford classification Stage IV, two patients Stage V, and six patients Stage VI). In patients with arterial ulcers, NIRS optodes were placed near the ulcer of the diseased foot (Optode 1), and at the same spot at the contralateral foot (Optode 2). In patients without arterial ulcers, Optode 1 was placed on the dorsum of the diseased foot, and Optode 2 was placed on the dorsum of the contralateral foot. Single Sto2 values, ankle brachial indices, and toe brachial indices were obtained at rest before the start of endovascular revascularization and 4 weeks after treatment. During the endovascular procedure, continuous Sto2 measurements were recorded throughout the intervention. Completion angiograms were used to evaluate the success of intervention. RESULTS: Patients underwent treatment of the superficial femoral artery (79%), popliteal artery (21%), and below the knee arteries (43%). In 13 of the 14 patients, completion angiograms showed successful treatment of target lesions. Ankle brachial indices and toe brachial indices significantly increased 4 weeks after treatment (both p < .01). Single Sto2 values of Optode 1 also significantly increased four weeks after treatment (p < .01). In contrast, single Sto2 values of Optode 2 did not (p = .73). During the endovascular procedure, continuous Sto2 measurements of Optode 1 and 2 did not increase (p = .80, and p = .61, respectively). CONCLUSIONS: NIRS monitoring of foot oxygenation in patients undergoing endovascular revascularization is safe and feasible. NIRS is a promising non-invasive technique to monitor hemodynamic changes in the feet of CLI patients after endovascular treatment using single Sto2 values.


Assuntos
Angioplastia com Balão , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Pé/irrigação sanguínea , Isquemia/terapia , Oxigênio/sangue , Doença Arterial Periférica/terapia , Espectroscopia de Luz Próxima ao Infravermelho , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Biomarcadores/sangue , Estado Terminal , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Isquemia/sangue , Isquemia/diagnóstico , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/sangue , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Projetos Piloto , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA