Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Phys Imaging Radiat Oncol ; 31: 100598, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38993288

RESUMO

Background & purpose: Magnetic resonance imaging (MRI) is increasingly used in treatment preparation of ocular proton therapy, but its spatial accuracy might be limited by geometric distortions due to susceptibility artefacts. A correct geometry of the MR images is paramount since it defines where the dose will be delivered. In this study, we assessed the geometrical accuracy of ocular MRI. Materials & methods: A dedicated ocular 3 T MRI protocol, with localized shimming and increased gradients, was compared to computed tomography (CT) and X-ray images in a phantom and in 15 uveal melanoma patients. The MRI protocol contained three-dimensional T2-weighted and T1-weighted sequences with an isotropic reconstruction resolution of 0.3-0.4 mm. Tantalum clips were identified by three observers and clip-clip distances were compared between T2-weighted and T1-weighted MRI, CT and X-ray images for the phantom and between MRI and X-ray images for the patients. Results: Interobserver variability was below 0.35 mm for the phantom and 0.30(T1)/0.61(T2) mm in patients. Mean absolute differences between MRI and reference were below 0.27 ± 0.16 mm and 0.32 ± 0.23 mm for the phantom and in patients, respectively. In patients, clip-clip distances were slightly larger on MRI than on X-ray images (mean difference T1: 0.11 ± 0.38 mm, T2: 0.10 ± 0.44 mm). Differences did not increase at larger distances and did not correlate to interobserver variability. Conclusions: A dedicated ocular MRI protocol can produce images of the eye with a geometrical accuracy below half the MRI acquisition voxel (<0.4 mm). Therefore, these images can be used for ocular proton therapy planning, both in the current model-based workflow and in proposed three-dimensional MR-based workflows.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38971383

RESUMO

Although rare cancers, ocular tumors are a threat to vision, quality of life, and potentially life expectancy of a patient. Ocular proton therapy (OPT) is a powerful tool for successfully treating this disease. The Particle Therapy Co-Operative Ocular Group) formulated an Evidence and Expert-Based Executive Summary of Current Practices and Future Developments in OPT: comparative dosimetric and clinical analysis with the different OPT systems is essential to set up planning guidelines, implement best practices, and establish benchmarks for eye preservation, vision, and quality of life measures. Contemporary prospective trials in select subsets of patients (eg, tumors near the optic disc and/or macula) may allow for dosimetric and clinical analysis between different radiation modalities and beamline systems to evaluate differences in radiation delivery and penumbra, and resultant tumor control, normal tissue complication rates, and overall clinical cost-effectiveness. To date, the combination of multimodal imaging (fundus photography, ultrasound, etc), ophthalmologist assessment, and clip surgery with radiation planning have been keys to successful treatment. Increased use of three-dimensional imaging (computed tomography/magnetic resonance imaging) is anticipated although its spatial resolution might be a limiting factor (eg, detection of flat diffuse tumor parts). Commercially produced ocular treatment-planning systems are under development and their future use is expected to expand across OPT centers. Future continuity of OPT will depend on the following: (1) maintaining and upgrading existing older dedicated low-energy facilities, (2) maintaining shared, degraded beamlines at large proton therapy centers, and (3) developing adapted gantry beams of sufficient quality to maintain the clinical benefits of sharp beam conformity. Option (1) potentially offers the sharpest beams, minimizing impact on healthy tissues, whereas (2) and (3) potentially offer the advantage of substantial long-term technical support and development as well as the introduction of new approaches. Significant patient throughputs and close cooperation between medical physics, ophthalmology, and radiation therapy, underpinned by mutual understanding, is crucial for a successful OPT service.

3.
Invest Ophthalmol Vis Sci ; 65(1): 43, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38271188

RESUMO

Purpose: Although fundus photography is extensively used in ophthalmology, refraction prevents accurate distance measurement on fundus images, as the resulting scaling differs between subjects due to varying ocular anatomy. We propose a PARaxial Optical fundus Scaling (PAROS) method to correct for this variation using commonly available clinical data. Methods: The complete optics of the eye and fundus camera were modeled using ray transfer matrix formalism to obtain fundus image magnification. The subject's ocular geometry was personalized using biometry, spherical equivalent of refraction (RSE), keratometry, and/or corneal topography data. The PAROS method was validated using 41 different eye phantoms and subsequently evaluated in 44 healthy phakic subjects (of whom 11 had phakic intraocular lenses [pIOLs]), 29 pseudophakic subjects, and 21 patients with uveal melanoma. Results: Validation of the PAROS method showed small differences between model and actual image magnification (maximum 3.3%). Relative to the average eye, large differences in fundus magnification were observed, ranging from 0.79 to 1.48. Magnification was strongly inversely related to RSE (R2 = 0.67). In phakic subjects, magnification was directly proportional to axial length (R2 = 0.34). The inverse relation was seen in pIOL (R2 = 0.79) and pseudophakic (R2 = 0.12) subjects. RSE was a strong contributor to magnification differences (1%-83%). As this effect is not considered in the commonly used Bennett-Littmann method, statistically significant differences up to 40% (mean absolute 9%) were observed compared to the PAROS method (P < 0.001). Conclusions: The significant differences in fundus image scaling observed among subjects can be accurately accounted for with the PAROS method, enabling more accurate quantitative assessment of fundus photography.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Refração Ocular , Humanos , Oftalmoscopia , Fundo de Olho , Córnea
4.
Cancers (Basel) ; 15(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38001679

RESUMO

BACKGROUND: Uveal melanoma (UM) is a rare intraocular tumor with a dismal prognosis once metastasized. This study provides a nationwide overview and time trends of patients diagnosed with primary UM in the Netherlands between 1989 and 2019. METHODS: A retrospective population-based cohort study based on patients with primary UM from the database of the Netherlands Cancer Registry (NCR), linked with the national population registry Statistics Netherlands on inhabitants' cause of death. Two time periods (1989-2004, 2005-2019) were compared with descriptive statistics. Kaplan-Meier and (multivariate) Cox proportional hazard models were used to assess changes over time for overall survival (OS) and cancer-specific survival (CSS). RESULTS: In total, 5036 patients were analyzed with a median age of 64.0 years at the time of diagnosis. The number of patients increased over time. In the first (1989-2004) and second (2005-2019) period, 32% versus 54% of the patients received radiotherapy (p < 0.001). The median FU time was 13.4 years. The median OS of the first and second periods was 9.5 (95% CI 8.7-10.3) versus 11.3 years (95% CI 10.3-12.3; p < 0.001). The median CSS was 30.0 years (95% CI NA) in the first period and not reached in the second period (p = 0.008). In multivariate analysis (MVA), female gender (HR 0.85; 95% CI 0.79-0.92, p < 0.001) and radiotherapy treatment (HR 0.73; 95% CI 0.64-0.83, p < 0.001) were associated with better OS. Radiotherapy treatment (HR 0.74; 95% CI 0.61-0.90, p = 0.002) was also associated with better CSS. The period of diagnosis was not associated with OS or CSS. CONCLUSIONS: In this study of patients with primary UM, there was a shift to the diagnosis of smaller tumors, possibly due to stage migration. There was also an increase in eye-preserving treatments over time. OS and CSS were modestly improved in the second time period; however, the time period was not associated with OS or CSS in multivariate analyses.

5.
Acta Ophthalmol ; 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698026

RESUMO

PURPOSE: To adapt the Quality of Vision Questionnaire (QoV) for measuring negative dysphotopsia and to validate the original and modified versions in the Dutch population. METHODS: The QoV was translated into Dutch according to standardized methodology. Negative dysphotopsia items were constructed based on focus group interviews, literature review and clinical data. The questionnaire was completed by 404 subjects, including contact lens wearers, patients with cataract and after cataract surgery (95.5% with a monofocal, 4.5% with a multifocal intraocular lens). Rasch analysis was applied for evaluation of reliability and validity of the original QoV and modified version, Negative Dysphotopsia QoV (ND-QoV). RESULTS: The frequency, severity and bothersome scales of the QoV and ND-QoV demonstrated good measurement precision, good fit statistics for all but one item, but significant mistargeting of more than one logit. Item estimations were stable across the study groups and scales were unidimensional with more than 50% of variance explained by the measurements. There was a positive correlation between questionnaire scores and best corrected visual acuity (r = 0.3, p < 0.01). The quality of vision measured by all three scales was significantly poorer (p < 0.01) in patients with negative dysphotopsia compared to asymptomatic pseudophakic patients. CONCLUSION: The Dutch version of the QoV questionnaire has shown good psychometric properties comparable to the native version as well as good reliability and validity. The addition of negative dysphotopsia items is a valuable modification for the reliable assessment of quality of vision in pseudophakic patients.

6.
J Cataract Refract Surg ; 49(12): 1270-1274, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37702454

RESUMO

PURPOSE: To assess whether intraocular lens (IOL) implantation induces shifts in the peripheral visual field. SETTING: Department of Ophthalmology, Leiden University Medical Center, Leiden, the Netherlands. DESIGN: Ray-tracing study. METHODS: Nonsequential ray-tracing simulations were performed with phakic and pseudophakic versions of the same eye model to assess potential shifts in the visual field after IOL implantation. 2 different IOL designs were evaluated and for each design 5 different axial positions and 7 different intrinsic powers were tested. The relation between the physical position of the light source and the location where the retina was illuminated was determined for each eye model. Subsequently, these relations were used to calculate whether the visual field shifts in pseudophakic eyes. RESULTS: The pseudophakic visual field shift was below 1 degree for central vision in all evaluated models. For peripheral vision, the light rays in the pseudophakic eyes were refracted to a more central retinal location compared with phakic eyes, resulting in a central shift of the peripheral visual field. The magnitude of the shift depended on the IOL design and its axial position, but could be as high as 5.4 degrees towards central vision. CONCLUSIONS: IOL implantation tends to have little effect on the central visual field but can induce an over 5 degrees shift in the peripheral visual field. Such a shift can affect the perception of peripheral visual complaints.


Assuntos
Implante de Lente Intraocular , Campos Visuais , Humanos , Retina , Centros Médicos Acadêmicos , Países Baixos
7.
Cancers (Basel) ; 15(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37296958

RESUMO

Conversely to most tumour types, magnetic resonance imaging (MRI) was rarely used for eye tumours. As recent technical advances have increased ocular MRI's diagnostic value, various clinical applications have been proposed. This systematic review provides an overview of the current status of MRI in the clinical care of uveal melanoma (UM) patients, the most common eye tumour in adults. In total, 158 articles were included. Two- and three-dimensional anatomical scans and functional scans, which assess the tumour micro-biology, can be obtained in routine clinical setting. The radiological characteristics of the most common intra-ocular masses have been described extensively, enabling MRI to contribute to diagnoses. Additionally, MRI's ability to non-invasively probe the tissue's biological properties enables early detection of therapy response and potentially differentiates between high- and low-risk UM. MRI-based tumour dimensions are generally in agreement with conventional ultrasound (median absolute difference 0.5 mm), but MRI is considered more accurate in a subgroup of anteriorly located tumours. Although multiple studies propose that MRI's 3D tumour visualisation can improve therapy planning, an evaluation of its clinical benefit is lacking. In conclusion, MRI is a complementary imaging modality for UM of which the clinical benefit has been shown by multiple studies.

8.
Neuroradiology ; 65(8): 1271-1285, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37249621

RESUMO

PURPOSE: MRI is increasingly used in the diagnosis and therapy planning of uveal melanoma (UM). In this prospective cohort study, we assessed the radiological characteristics, in terms of anatomical and functional imaging, of UM after ruthenium-106 plaque brachytherapy or proton beam therapy (PBT) and compared them to conventional ultrasound. METHODS: Twenty-six UM patients were evaluated before and 3, 6 and 12 months after brachytherapy (n = 13) or PBT (n = 13). Tumour prominences were compared between ultrasound and MRI. On diffusion-weighted imaging, the apparent diffusion value (ADC), and on perfusion-weighted imaging (PWI), the time-intensity curves (TIC), relative peak intensity and outflow percentages were determined. Values were compared between treatments and with baseline. RESULTS: Pre-treatment prominences were comparable between MRI and ultrasound (mean absolute difference 0.51 mm, p = 0.46), but larger differences were observed post-treatment (e.g. 3 months: 0.9 mm (p = 0.02)). Pre-treatment PWI metrics were comparable between treatment groups. After treatment, brachytherapy patients showed favourable changes on PWI (e.g. 67% outflow reduction at 3 months, p < 0.01). After PBT, significant perfusion changes were observed at a later timepoint (e.g. 38% outflow reduction at 6 months, p = 0.01). No consistent ADC changes were observed after either treatment, e.g. a 0.11 × 10-3mm2/s increase 12 months after treatment (p = 0.15). CONCLUSION: MR-based follow-up is valuable for PBT-treated patients as favourable perfusion changes, including a reduction in outflow, can be detected before a reduction in size is apparent on ultrasound. For brachytherapy, a follow-up MRI is of less value as already 3 months post-treatment a significant size reduction can be measured on ultrasound.


Assuntos
Braquiterapia , Terapia com Prótons , Neoplasias Uveais , Humanos , Seguimentos , Estudos Prospectivos , Terapia com Prótons/métodos , Braquiterapia/métodos , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/radioterapia , Imageamento por Ressonância Magnética , Estudos Retrospectivos
9.
J Neuromuscul Dis ; 10(5): 869-883, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37182896

RESUMO

INTRODUCTION: MRI of extra-ocular muscles (EOM) in patients with myasthenia gravis (MG) could aid in diagnosis and provide insights in therapy-resistant ophthalmoplegia. We used quantitative MRI to study the EOM in MG, healthy and disease controls, including Graves' ophthalmopathy (GO), oculopharyngeal muscular dystrophy (OPMD) and chronic progressive external ophthalmoplegia (CPEO). METHODS: Twenty recently diagnosed MG (59±19yrs), nineteen chronic MG (51±16yrs), fourteen seronegative MG (57±9yrs) and sixteen healthy controls (54±13yrs) were included. Six CPEO (49±14yrs), OPMD (62±10yrs) and GO patients (44±12yrs) served as disease controls. We quantified muscle fat fraction (FF), T2water and volume. Eye ductions and gaze deviations were assessed by synoptophore and Hess-charting. RESULTS: Chronic, but not recent onset, MG patients showed volume increases (e.g. superior rectus and levator palpebrae [SR+LPS] 985±155 mm3 compared to 884±269 mm3 for healthy controls, p < 0.05). As expected, in CPEO volume was decreased (e.g. SR+LPS 602±193 mm3, p < 0.0001), and in GO volume was increased (e.g. SR+LPS 1419±457 mm3, p < 0.0001). FF was increased in chronic MG (e.g. medial rectus increased 0.017, p < 0.05). In CPEO and OPMD the FF was more severely increased. The severity of ophthalmoplegia did not correlate with EOM volume in MG, but did in CPEO and OPMD. No differences in T2water were found. INTERPRETATION: We observed small increases in EOM volume and FF in chronic MG compared to healthy controls. Surprisingly, we found no atrophy in MG, even in patients with long-term ophthalmoplegia. This implies that even long-term ophthalmoplegia in MG does not lead to secondary structural myopathic changes precluding functional recovery.


Assuntos
Distrofia Muscular Oculofaríngea , Miastenia Gravis , Oftalmoplegia Externa Progressiva Crônica , Oftalmoplegia , Humanos , Lipopolissacarídeos , Músculos Oculomotores/diagnóstico por imagem , Miastenia Gravis/complicações , Miastenia Gravis/diagnóstico por imagem , Distrofia Muscular Oculofaríngea/complicações , Distrofia Muscular Oculofaríngea/diagnóstico por imagem , Oftalmoplegia/diagnóstico por imagem , Oftalmoplegia/etiologia , Imageamento por Ressonância Magnética
11.
Adv Radiat Oncol ; 8(3): 101149, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691449

RESUMO

Purpose: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. Methods and Materials: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. Results: The average GTV was significantly larger on T1gd (0.57cm3) compared with T2 (0.51cm3, P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. Conclusions: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.

12.
Ophthalmol Retina ; 7(2): 178-188, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35840053

RESUMO

OBJECTIVE: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to the recent advances in magnetic resonance imaging (MRI) of uveal melanoma (UM), it is possible to acquire high-resolution 3-dimensional images of the eye, providing the opportunity to incorporate MRI in ocular PT planning. In this study, we described how these measurements can be obtained using MRI, compared the MRI-based measurements with conventional ophthalmic measurements, and identified potential pitfalls for both modalities. DESIGN: Cross-sectional study. SUBJECTS: Data from 23 consecutive patients with UM treated with PT were retrospectively evaluated. METHODS: Magnetic resonance imaging-based measurements of axial length, tumor height and basal diameter, and marker-tumor distances were compared with the conventional ophthalmic measurements, and discrepancies were evaluated in a multidisciplinary setting. MAIN OUTCOME MEASURES: Tumor prominence and basal diameters on MRI and ultrasound, axial length on MRI and biometry, tumor-marker distances on MRI and measured intraoperatively. RESULTS: The mean absolute differences of the tumor height and basal diameter measurements between ultrasound and MRI were 0.57 mm and 1.44 mm, respectively. Larger absolute differences in height and basal diameter were observed when the full tumor extent was not visible on ultrasound (0.92 mm and 1.67 mm, respectively) compared with when the full tumor extent was visible (0.44 mm and 1.15 mm, respectively). When the full tumor was not visible on ultrasound, MRI was considered more reliable. Tumor-marker distances measured using MRI and intraoperative techniques differed < 1 mm in 55% of the markers. For anteriorly located and mushroom-shaped tumors (25% of the markers), MRI provided more accurate measurements. In flat UM (15% of the markers), however, it was difficult to delineate the tumor on MRI. The mean absolute difference in axial length between optical biometry and MRI was 0.50 mm. The presence of the tumor was found to influence optical biometry in 15 of 22 patients; the remaining patients showed a better agreement (0.30 mm). Magnetic resonance imaging-based biometry was considered more reliable in patients with UM. CONCLUSIONS: Magnetic resonance imaging allowed for the 3-dimensional assessment of the tumor and surrounding tissue. In specific patients, it provided a more reliable measurement of axial length, tumor dimensions, and marker-tumor distances and could contribute to a more accurate treatment planning. Nevertheless, a combined evaluation remains advised, especially for flat UM.


Assuntos
Terapia com Prótons , Humanos , Estudos Transversais , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
13.
J Neurol Neurosurg Psychiatry ; 94(2): 151, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36261286

RESUMO

INTRODUCTION: Diagnosing ocular myasthenia gravis (MG) can be challenging because serum antibodies are often not detected. We aimed to explore whether determining extraocular muscle (EOM) weakness using orthoptic measures, including an adapted Hess chart examination, can aid in diagnosing MG. METHODS: We conducted a prospective study among patients with acetylcholine receptor antibody positive MG (20 recently diagnosed, 19 chronic) and 14 seronegative MG patients. We compared orthoptic measures to 19 healthy and 18 disease controls with Graves orbitopathy, chronic progressive external ophthalmoplegia or oculopharyngeal muscular dystrophy. Maximal eye duction angles were measured using a synoptophore. Gaze deviations between eyes were measured using standard Hess chart examination with addition of 1 min persistent gaze to assess MG-associated fatiguability. Receiver operating characteristics curve analysis was performed. RESULTS: For duction angles, the area under the curve (AUC) was 0.73 comparing MG to healthy, and 0.69 comparing to patient controls. For the outer field of the Hess chart, the AUC was 0.89 comparing to healthy and 0.54 to patient controls. For drift, the AUC was 0.93 comparing to healthy and 0.93 to patient controls. The sensitivity and specificity of the presence of drift was 81% and 100%. DISCUSSION: Orthoptic measurements can be used to diagnose MG by quantifying EOM weakness and fatiguability. Drift during persistent gaze on a Hess chart is specific for MG and could be used for diagnostic purposes. The Hess chart examination is widely available, inexpensive and fast. Moreover, orthoptic measurements may be a clinically relevant outcome measure for clinical trials.


Assuntos
Oftalmopatia de Graves , Miastenia Gravis , Transtornos da Motilidade Ocular , Humanos , Músculos Oculomotores , Ortóptica , Oftalmopatia de Graves/complicações , Estudos Prospectivos , Miastenia Gravis/diagnóstico , Transtornos da Motilidade Ocular/diagnóstico
14.
J Cataract Refract Surg ; 48(12): 1446-1452, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36449675

RESUMO

PURPOSE: To assess the effect of ocular anatomy and intraocular lens (IOL) design on negative dysphotopsia (ND). SETTING: Department of Ophthalmology, Leiden University Medical Center, Leiden, the Netherlands. DESIGN: Ray-tracing study based on clinical data. METHODS: Ray-tracing simulations were performed to assess the effect of anatomical differences and differences in IOL design on the peripheral retinal illumination. To that end, eye models that incorporate clinically measured anatomical differences between eyes of patients with ND and eyes of pseudophakic controls were created. The anatomical differences included pupil size, pupil centration, and iris tilt. The simulations were performed with different IOL designs, including a simple biconvex IOL design and a more complex clinical IOL design with a convex-concave anterior surface. Both IOL designs were analyzed using a clear edge and a frosted edge. As ND is generally considered to be caused by a discontinuity in peripheral retinal illumination, this illumination profile was determined for each eye model and the severity of the discontinuity was compared between eye models. RESULTS: The peripheral retinal illumination consistently showed a more severe discontinuity in illumination with ND-specific anatomy. This difference was the least pronounced, 8%, with the frosted edge clinical IOL and the most pronounced, 18%, with the clear edge biconvex IOL. CONCLUSIONS: These results show that small differences in the ocular anatomy or IOL design affect the peripheral retinal illumination. Therewith, they can increase the severity of ND by up to 18%.


Assuntos
Lentes Intraoculares , Oftalmologia , Humanos , Retina , Iluminação , Iris
15.
Phys Imaging Radiat Oncol ; 24: 102-110, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36386446

RESUMO

Background and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods: Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results: Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions: The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.

16.
PLoS One ; 17(10): e0276527, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36264982

RESUMO

PURPOSE: To assess if ocular motility impairment, and the ensuing diplopia, after Baerveldt Glaucoma device (BGI) implantation, is related to the presence of a large fluid reservoir (bleb), using Magnetic Resonance Imaging (MRI). METHODS: In a masked observational study (CCMO-registry number: NL65633.058.18), the eyes of 30 glaucoma patients with (n = 12) or without diplopia (n = 18) who had previously undergone BGI implantation were scanned with a 7 Tesla MRI-scanner. The substructures of the BGI-complex, including both blebs and plate, were segmented in 3D. Primary outcomes were a comparison of volume and height of the BGI-complex between patients with and without diplopia. Comparisons were performed by using an unpaired t-test, Fisher's Exact or Mann-Whitney test. Correlations were determined by using Spearman correlation. RESULTS: The median volume and height of the BGI-complex was significantly higher in patients with compared to patients without diplopia (p = 0.007 and p = 0.025, respectively). Six patients had an excessively large total bleb volume (median of 1736.5mm3, interquartile range 1486.3-1933.9mm3), four of whom experienced diplopia (33% of the diplopia patients). Fibrotic strands through the BGI plate, intended to limit the height of the bleb, could be visualized but were not related to diplopia (75% versus 88%; p = 0.28). CONCLUSIONS: With MRI, we show that in a significant number of diplopia cases a large bleb is present in the orbit. Given the large volume of these blebs, they are a likely explanation of the development of diplopia in at least some of the patients with diplopia after BGI implantation. Additionally, the MR-images confirm the presence of fibrotic strands. As these strands are also visible in patients with a large bleb, they are apparently not sufficient to restrict the bleb height.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Diplopia/etiologia , Glaucoma/diagnóstico por imagem , Glaucoma/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos , Pressão Intraocular , Imageamento por Ressonância Magnética/métodos , Acuidade Visual
17.
J Cachexia Sarcopenia Muscle ; 13(6): 2820-2834, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36172973

RESUMO

Ophthalmoparesis and ptosis can be caused by a wide range of rare or more prevalent diseases, several of which can be successfully treated. In this review, we provide clues to aid in the diagnosis of these diseases, based on the clinical symptoms, the involvement pattern and imaging features of extra-ocular muscles (EOM). Dysfunction of EOM including the levator palpebrae can be due to muscle weakness, anatomical restrictions or pathology affecting the innervation. A comprehensive literature review was performed to find clinical and imaging clues for the diagnosis and follow-up of ptosis and ophthalmoparesis. We used five patterns as a framework for differential diagnostic reasoning and for pattern recognition in symptomatology, EOM involvement and imaging results of individual patients. The five patterns were characterized by the presence of combination of ptosis, ophthalmoparesis, diplopia, pain, proptosis, nystagmus, extra-orbital symptoms, symmetry or fluctuations in symptoms. Each pattern was linked to anatomical locations and either hereditary or acquired diseases. Hereditary muscle diseases often lead to ophthalmoparesis without diplopia as a predominant feature, while in acquired eye muscle diseases ophthalmoparesis is often asymmetrical and can be accompanied by proptosis and pain. Fluctuation is a hallmark of an acquired synaptic disease like myasthenia gravis. Nystagmus is indicative of a central nervous system lesion. Second, specific EOM involvement patterns can also provide valuable diagnostic clues. In hereditary muscle diseases like chronic progressive external ophthalmoplegia (CPEO) and oculo-pharyngeal muscular dystrophy (OPMD) the superior rectus is often involved. In neuropathic disease, the pattern of involvement of the EOM can be linked to specific cranial nerves. In myasthenia gravis this pattern is variable within patients over time. Lastly, orbital imaging can aid in the diagnosis. Fat replacement of the EOM is commonly observed in hereditary myopathic diseases, such as CPEO. In contrast, inflammation and volume increases are often observed in acquired muscle diseases such as Graves' orbitopathy. In diseases with ophthalmoparesis and ptosis specific patterns of clinical symptoms, the EOM involvement pattern and orbital imaging provide valuable information for diagnosis and could prove valuable in the follow-up of disease progression and the understanding of disease pathophysiology.


Assuntos
Blefaroptose , Oftalmopatia de Graves , Miastenia Gravis , Oftalmoplegia , Humanos , Oftalmopatia de Graves/complicações , Blefaroptose/etiologia , Blefaroptose/complicações , Oftalmoplegia/diagnóstico , Oftalmoplegia/complicações , Diplopia/diagnóstico , Diplopia/etiologia , Miastenia Gravis/complicações , Miastenia Gravis/diagnóstico , Dor/complicações
18.
Optom Vis Sci ; 99(8): 645-651, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35930259

RESUMO

SIGNIFICANCE: There is a clinical need for a quantitative test to objectively diagnose negative dysphotopsia, especially because the diagnosis is generally assessed using patients' subjective descriptions. In the search of a clinical test to objectify the shadow experienced in negative dysphotopsia, this study excludes static perimetry as suitable evaluation method. PURPOSE: This study aimed to evaluate the value of static perimetry in the objective assessment and follow-up of negative dysphotopsia. METHODS: Peripheral 60-4 full-threshold visual field tests were performed in 27 patients with negative dysphotopsia and 33 pseudophakic controls. In addition, 11 patients with negative dysphotopsia repeated the test after an intraocular lens exchange. Both the total peripheral visual field and the averaged peripheral visual field from 50 to 60° eccentricity were compared between patients and controls, and pre-operatively and post-operatively in patients who had an intraocular lens exchange. RESULTS: The peripheral visual fields from 30 to 60° did not show significant differences between patients with negative dysphotopsia and pseudophakic controls. Analysis of the peripheral visual field from 50 to 60° showed a median [Q1, Q3] of 20.0 [17.1, 22.5] dB in the negative dysphotopsia group compared with 20.1 [15.5, 21.3] dB in the control group (P = .43). Although 82% of patients treated with an intraocular lens exchange subjectively reported improvement of their negative dysphotopsia complaints post-operatively, there were no significant differences in their total peripheral visual field or averaged peripheral visual field from 50 to 60° (P = .92). CONCLUSIONS: Full-threshold static perimetry with a Goldmann size III stimulus up to 60° eccentricity does not show significant differences between patients with negative dysphotopsia and pseudophakic controls or between measurements before and after intraocular lens exchange. Therefore, this type of static perimetry cannot be used as a quantitative objective test for diagnosis or follow-up of patients with negative dysphotopsia.


Assuntos
Lentes Intraoculares , Testes de Campo Visual , Seguimentos , Humanos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia
20.
Ophthalmic Res ; 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35358966

RESUMO

Uveal Melanoma (UM) is the most common primary intra-ocular tumor in adults. New diagnostic procedures and basic science discoveries continue to change our patient management paradigms. A recent meeting of the European Vision Institute (EVI) special interest focus group was held on "Outcome Measures of New Technologies in Uveal Melanoma", addressing the latest advances in UM, starting with genetic developments, then moving on to imaging and treatment of the primary tumor, as well as to investigating the most recent developments in treating metastases, and eventually taking care of the patient's wellbeing. This review highlights the meeting's presentations in the context of the published literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA