Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Pharm Biopharm ; 84(1): 99-105, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23298622

RESUMO

The present study was conducted to examine the feasibility of nimodipine-loaded PLGA microparticles suspended in Tisseel fibrin sealant as an in situ forming depot system. This device locally placed can be used for the treatment of vasospasm after a subarachnoid hemorrhage. Microparticles were prepared via spray-drying by using the vibration mesh spray technology of Nano Spray Dryer B-90. Spherically shaped microparticles with different loadings and high encapsulation efficiencies of 93.3-97.8% were obtained. Depending on nimodipine loading (10-40%), the particle diameter ranged from 1.9 ± 1.2 µm to 2.4 ± 1.3 µm. Thermal analyses using DSC revealed that nimodipine is dissolved in the PLGA matrix. Also, fluorescent dye loaded microparticles were encapsulated in Tisseel to examine the homogeneity of particles. 3D-pictures of the in situ forming devices displayed uniform particle homogeneity in the sealant matrix. Drug release was examined by fluorescence spectrophotometry which demonstrated a drug release proportional to the square root of time. A prolonged drug release of 19.5h was demonstrated under in vitro conditions. Overall, the nimodipine in situ forming device could be a promising candidate for the local treatment of vasospasm after a subarachnoid hemorrhage.


Assuntos
Microesferas , Nimodipina/química , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Preparações de Ação Retardada/química , Preparações de Ação Retardada/farmacocinética , Nimodipina/farmacocinética , Resultado do Tratamento
2.
Macromol Biosci ; 12(7): 970-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22648959

RESUMO

The aim of this study is to investigate the feasibility and efficacy of PEC nanoparticles as delivery system for cancer chemotherapy. Assembly of paclitaxel-loaded nanoparticles with high loading efficiency and narrow-size distribution is successful. For non-invasive in vivo tracing, nanoparticle blends of chelator bearing poly(lactide) with PEC and PLGA are successfully prepared. Pharmacokinetic studies in mice reveal a twofold higher circulation time of PEC as compared to PLGA. A tumor model shows an accumulation of PEC NPs in cancerous tissue and a higher anti-tumor efficiency compared to the standard Taxol™, which is reflected in a significantly slower tumor growth compared to the NaCl control group.


Assuntos
Antineoplásicos Fitogênicos/farmacocinética , Portadores de Fármacos/síntese química , Nanopartículas/química , Paclitaxel/farmacocinética , Polietilenos/síntese química , Animais , Antineoplásicos Fitogênicos/administração & dosagem , Radioisótopos de Carbono , Composição de Medicamentos , Estabilidade de Medicamentos , Humanos , Ácido Láctico , Melanoma Experimental , Camundongos , Camundongos Nus , Transplante de Neoplasias , Paclitaxel/administração & dosagem , Tamanho da Partícula , Ácido Poliglicólico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Resultado do Tratamento , Carga Tumoral/efeitos dos fármacos
3.
Eur J Pharm Biopharm ; 80(3): 562-70, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22209978

RESUMO

First generation drug eluting stents (DES) show a fivefold higher risk of late stent thrombosis compared to bare metal stents. Therefore, new biodegradable and biocompatible polymers for stent coating are needed to reduce late stent thrombosis. In this study, a reproducible spray-coating process for stents coated with Poly(ethylene carbonate), PEC, and Paclitaxel was investigated. PEC is a biocompatible, thermoelastic polymer of high molecular weight. The surface degradation of PEC is triggered by superoxide anions produced by polymorphonuclear leukocytes and macrophages during inflammatory processes. Stents with different drug loading were reproducibly produced by a spray-coating apparatus. Confocal laser scanning micrographs of fluorescent dye loaded stents were made to investigate the film homogeneity. The abluminal stent site was loaded more than the luminal site, which is superior for DES. The deposition of the layers was confirmed by TOF-SIMS investigations. Referring to the stent surface, the drug loading is 0.32 µg (± 0.05) (once coated), 0.53 µg (± 0.11) (twice coated), or 0.73 µg (± 0.06) (three times coated) Paclitaxel per mm(2) stent surface. The in vitro release mechanism during non-degradation conditions can be explained by diffusion-controlled drug release slightly influenced by swelling of PEC, revealing that 100% of the loaded Paclitaxel will be released via diffusion within 2 months. So, the in vivo release kinetic is a combination of diffusion-controlled drug release and degradation-controlled drug release depending on the presence or absence of superoxide anions and accordingly depending on the presence or absence of macrophages. We conclude that the specific release kinetics of PEC, its biocompatibility, and the favorable mechanical properties will be beneficial for a next generation drug eluting stent meriting further investigations under in vivo conditions.


Assuntos
Materiais Revestidos Biocompatíveis/química , Stents Farmacológicos , Polietilenos/química , Polímeros/química , Implantes Absorvíveis , Preparações de Ação Retardada , Difusão , Portadores de Fármacos/química , Óxido de Etileno/química , Excipientes/química , Cinética , Paclitaxel/química , Trombose/induzido quimicamente
4.
Macromol Biosci ; 11(7): 897-904, 2011 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-21472988

RESUMO

The goal of this study was to investigate the suitability of poly(ethylene carbonate) (PEC) nanoparticles as a novel drug delivery system, fulfilling the requirements for a long circulation time. Particles were obtained with a narrow size distribution and nearly neutral zeta potential. Adsorption studies with human plasma proteins revealed that PEC nanoparticles bind much less proteins in comparison to polystyrene (PS) nanoparticles. Cell experiments with fluorescently labeled PEC showed no uptake of the nanoparticles by macrophages. These novel PEC nanospheres with their unique surface properties are a promising candidate for long circulating drug delivery systems in vivo.


Assuntos
Portadores de Fármacos/química , Nanosferas/química , Polietilenos/química , Adsorção , Animais , Proteínas Sanguíneas/metabolismo , Portadores de Fármacos/metabolismo , Sistemas de Liberação de Medicamentos , Corantes Fluorescentes , Humanos , Macrófagos/imunologia , Macrófagos/metabolismo , Camundongos , Tamanho da Partícula , Polietilenos/metabolismo , Ligação Proteica , Propriedades de Superfície
5.
Int J Pharm ; 407(1-2): 190-6, 2011 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-21256945

RESUMO

The aim of this study was to formulate nanoparticles from three different hyperbranched polymers, namely an unmodified dendritic polyester (Boltorn H40™), a lipophilic, fatty acid modified dendritic polymer (Boltorn U3000™) and an amphiphilic dendritic polymer (Boltorn W3000™) for drug delivery of paclitaxel and to investigate their properties. A solvent displacement method allowed preparation of nanoparticles from all three hyperbranched polymers. Nanoparticle sizes ranged from 70 to 170 nm. The lipophilic Boltorn U3000™ formed the biggest nanoparticles and the amphiphilic Boltorn W3000™ formed the smallest ones. Nanoparticles of amphiphilic Boltorn W3000™ displayed only a slightly negative zeta potential, while more negative zeta potentials were measured for nanoparticles based on the other two polymers. Degradation profiles were investigated by short time pH-stat titration. Boltorn H40™ showed a faster degradation rate then the two other fatty acid containing polymers. For Boltorn H40™, degradation rate was also investigated in longer term mass loss studies resulting in 30% degradation during 3 weeks. Cytotoxicity of the nanoparticles was studied by MTT assay displaying low cytotoxicity for all three polymers. All three types of nanoparticles were loaded with paclitaxel and their release profiles were studied. Sizes and zeta potentials remained stable after loading and did not change significantly. These three types of hyperbranched polymers show potential as nanoparticulate delivery systems and should be further studied. Due to their high loading efficiency, Boltorn U3000 and W3000 represent the most interesting candidates.


Assuntos
Antineoplásicos Fitogênicos/administração & dosagem , Dendrímeros , Paclitaxel/administração & dosagem , Poliésteres/química , Animais , Antineoplásicos Fitogênicos/farmacologia , Linhagem Celular Tumoral , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos , Estabilidade de Medicamentos , Camundongos , Nanopartículas , Paclitaxel/farmacologia , Tamanho da Partícula , Polímeros/química , Solventes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA