Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Cybern ; 47(5): 1251-1262, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27076479

RESUMO

Neuromuscular electrical stimulation (NMES) induces muscle contractions via electrical stimuli. NMES can be used for rehabilitation and to enable functional movements; however, a fundamental limitation is the early onset of fatigue. Asynchronous stimulation is a method that can reduce fatigue by utilizing multiple stimulation channels to segregate and switch between different sets of recruited motor units. However, switching between stimulation channels is challenging due to each channel's differing response to stimulation. To address this challenge, a switched systems analysis is used in the present work to design a controller that allows for instantaneous switching between stimulation channels. The developed controller yields semi-global exponential tracking of a desired angular trajectory for a person's knee-joint. Experiments were conducted in six able-bodied individuals. Compared to conventional stimulation, the results indicate that asynchronous stimulation with the developed controller yields longer durations of successful tracking despite different responses between the stimulation channels.

2.
IEEE Trans Neural Syst Rehabil Eng ; 24(12): 1373-1383, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26584496

RESUMO

Functional electrical stimulation (FES) can be used to activate the dysfunctional lower limb muscles of individuals with neurological disorders to produce cycling as a means of rehabilitation. However, previous literature suggests that poor muscle control and nonphysiological muscle fiber recruitment during FES-cycling causes lower efficiency and power output at the cycle crank than able-bodied cycling, thus motivating the investigation of improved control methods for FES-cycling. In this paper, a stimulation pattern is designed based on the kinematic effectiveness of the rider's hip and knee joints to produce a forward torque about the cycle crank. A robust controller is designed for the uncertain, nonlinear cycle-rider system with autonomous, state-dependent switching. Provided sufficient conditions are satisfied, the switched controller yields ultimately bounded tracking of a desired cadence. Experimental results on four able-bodied subjects demonstrate cadence tracking errors of 0.05 ±1.59 and 5.27 ±2.14 revolutions per minute during volitional and FES-induced cycling, respectively. To establish feasibility of FES-assisted cycling in subjects with Parkinson's disease, experimental results with one subject demonstrate tracking errors of 0.43 ± 4.06 and 0.17 ±3.11 revolutions per minute during volitional and FES-induced cycling, respectively.


Assuntos
Ciclismo , Terapia por Estimulação Elétrica/métodos , Transtornos dos Movimentos/fisiopatologia , Transtornos dos Movimentos/reabilitação , Contração Muscular , Músculo Esquelético/fisiopatologia , Adulto , Simulação por Computador , Articulação do Quadril/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Modelos Biológicos , Esforço Físico , Terapia Assistida por Computador/métodos
3.
IEEE Trans Neural Syst Rehabil Eng ; 23(6): 1117-27, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25935038

RESUMO

Neuromuscular electrical stimulation (NMES) is commonly used in rehabilitative settings and is also used for assistive purposes to create functional movements, where it is termed functional electrical stimulation (FES). One limitation of NMES/FES is early onset of muscle fatigue. NMES-induced fatigue can be reduced by switching between multiple stimulation channels that target different motor units or synergistic muscles (i.e., asynchronous stimulation). However, switching stimulation channels introduces additional complexity due to the need to consider the switching dynamics and differing muscle response to stimulation. The objective of this study was to develop and test a closed-loop controller for asynchronous stimulation. The developed closed-loop controller yields asymptotic tracking of a desired trajectory for a person's knee-shank complex despite switching between stimulation channels. The developed controller was implemented on four able-bodied individuals with four-channel asynchronous stimulation as well as single-channel conventional stimulation. The results indicate that asynchronous stimulation extends the duration that functional movements can be performed during feedback control. This result is promising for the implementation of asynchronous stimulation in closed-loop rehabilitative procedures and in assistive devices as a method to reduce muscle fatigue while maintaining a person's ability to track a desired limb trajectory.


Assuntos
Estimulação Elétrica/métodos , Extremidade Inferior/fisiologia , Movimento/fisiologia , Adulto , Algoritmos , Fenômenos Biomecânicos , Estimulação Elétrica/efeitos adversos , Desenho de Equipamento , Retroalimentação Fisiológica , Voluntários Saudáveis , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiologia , Masculino , Modelos Anatômicos , Fadiga Muscular , Músculo Esquelético , Tecnologia Assistiva , Adulto Jovem
4.
IEEE Trans Neural Syst Rehabil Eng ; 23(6): 964-72, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25350934

RESUMO

Neuromuscular electrical stimulation (NMES) has been shown to impart a number of health benefits and can be used to produce functional outcomes. However, one limitation of NMES is the onset of NMES-induced fatigue. Multi-channel asynchronous stimulation has been shown to reduce NMES-induced fatigue compared to conventional single-channel stimulation. However, in previous studies in man, the effect of stimulation frequency on the NMES-induced fatigue has not been examined for asynchronous stimulation. Low stimulation frequencies are known to reduce fatigue during conventional stimulation. Therefore, the aim of this study was to examine the fatigue characteristics of high- and low-frequency asynchronous stimulation as well as high- and low-frequency conventional stimulation. Experiments were performed in both able-bodied and spinal cord injured populations. Low frequency asynchronous stimulation is found to have significant fatigue benefits over high frequency asynchronous stimulation as well as high- and low-frequency conventional stimulation, motivating its use for rehabilitation and functional electrical stimulation (FES).


Assuntos
Estimulação Elétrica , Fadiga Muscular , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/terapia , Adulto , Fenômenos Biomecânicos , Eletromiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Torque , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA