Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(3)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542544

RESUMO

We propose a new strategy using a sandwich approach for the detection of two HF biomarkers: tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10). For this purpose, magnetic nanoparticles (MNPs) (MNPs@aminodextran) were biofunctionalized with monoclonal antibodies (mAbs) using bis (sulfosuccinimidyl) suberate (BS3) as a cross-linker for the pre-concentration of two biomarkers (TNF-α and IL-10). In addition, our ISFETs were biofunctionalized with polyclonal antibodies (pAbs) (TNF-α and IL-10). The biorecognition between pAbs immobilized on the ISFET and the pre-concentrate antigen (Ag) on MNPs was monitored using electrochemical impedance spectroscopy (EIS). Our developed ImmunoFET showed a low detection limit (0.03 pg/mL) toward our target analyte when compared to previously published electrochemical immunosensors. It showed a higher sensitivity than for other HF biomarkers. Finally, the standard addition method was used to determine the unknown concentration in artificial saliva. The results matched with the expected values well.

2.
Talanta ; 257: 123802, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36863297

RESUMO

Cortisol, a steroid hormone mostly known as "the stress hormone," plays many essential functions in humans due its involvement in several metabolic pathways. It is well-known that cortisol dysregulation is implied in evolution and progression of several chronic pathologies, including cardiac diseases such as heart failure (HF). However, although several sensors have been proposed to date for the determination of cortisol, none of them has been designed for its determination in saliva in order to monitor HF progression. In this work, a silicon nitride based Immuno field-effect transistor (ImmunoFET) has been proposed to quantify salivary cortisol for HF monitoring. Sensitive biological element was represented by anti-cortisol antibody bound onto the ISFET gate via 11-triethoxysilyl undecanal (TESUD) by vapor-phase method. Potentiometric and electrochemical impedance spectroscopy (EIS) measurements were carried out for preliminary investigations on device responsiveness. Subsequently, a more sensitive detection was obtained using electrochemical EIS. The proposed device has proven to have a linear response (R2 always >0.99), to be sensitive (with a limit of detection, LoD, of 0.005 ± 0.002 ng/mL), selective in case of other HF biomarkers (e.g. N-terminal pro B-type natriuretic peptide (NT-proBNP), tumor necrosis factor-alpha (TNF-α), and interleukin 10 (IL-10)), and accurate in cortisol quantification in saliva sample by performing the standard addition method.


Assuntos
Insuficiência Cardíaca , Hidrocortisona , Humanos , Espectroscopia Dielétrica , Insuficiência Cardíaca/diagnóstico , Biomarcadores , Saliva , Fragmentos de Peptídeos
3.
Talanta ; 251: 123759, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35952499

RESUMO

Heart failure (HF) is a chronic cardiovascular disease that represents main cause of mortality worldwide, particularly for elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) was identified as the gold standard biomarker for HF diagnosis and therapy monitoring. Presently, saliva analysis represents an emerging and powerful tool for clinical applications and electrochemical immunosensors have shown their potential in Healthcare applications as selective and reliable systems for detecting clinical biomarkers. This work presents the detection of NT-proBNP in saliva samples by an immunologically modified Field effect Transistor (IMFET). TESUD ((11-triethoxysilyl) undecanal) was used as cross-linker to immobilise anti-NT-proBNP antibody onto the device. Our IMFET that was then tested in different matrices (e.g. phosphate buffered saline (PBS), artificial saliva and human saliva) using electrochemical impedance spectroscopy (EIS), and it resulted selective to NT-proBNP with good sensitivity (detection limit of 0.02 pg/mL) and a wide linear range (0.02-1 pg/mL and 0.5-20 pg/mL). Finally, NT-proBNP concentration in ten saliva samples was determined by performing the standard addition method. An enzyme-linked immunosorbent assay was used for confirming IMFET results, highlighting both IMFET accuracy (analyte recovery of 99 ± 8%) and precision (coefficient of variation always <10%), and supporting the suitability of the device for determining salivary NT-proBNP.


Assuntos
Técnicas Biossensoriais , Insuficiência Cardíaca , Idoso , Humanos , Biomarcadores , Insuficiência Cardíaca/diagnóstico , Imunoensaio , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Fosfatos , Saliva , Saliva Artificial , Volume Sistólico , Técnicas Eletroquímicas
4.
Micromachines (Basel) ; 13(12)2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36557534

RESUMO

Assessing cortisol levels in human bodies has become essential to diagnose heart failure (HF). In this work, we propose a salivary cortisol detection strategy as part of an easily integrable lab-on-a-chip for detection of HF biomarkers. Our developed capacitive immunosensor based on hafnium oxide (HfO2)/silicon structure showed good linearity between increasing cortisol concentration and the charge-transfer resistance/capacitance. Moreover, the developed biosensor was demonstrated to be highly selective toward cortisol compared to other HF biomarkers such as tumor necrosis factor (TNF-α) and N-terminal pro-brain natriuretic peptide (NT-proBNP). The precision of our developed biosensor was evaluated, and the difference between the determined cortisol concentration in saliva and its expected one is <18%.

5.
Biosensors (Basel) ; 13(1)2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36671906

RESUMO

As an antibody-free sensing membrane for the detection of the antibiotic tetracycline (TC), a liquid PVC membrane doped with the ion-pair tetracycline/θ-shaped anion [3,3'-Co(1,2-C2B9H11)2]- ([o-COSAN]-) was formulated and deposited on a SWCNT modified gold microelectrode. The chosen transduction technique was electrochemical impedance spectroscopy (EIS). The PVC membrane was composed of: the tetracycline/[o-COSAN]- ion-pair, a plasticizer. A detection limit of 0.3 pg/L was obtained with this membrane, using bis(2-ethylhexyl) sebacate as a plasticizer. The sensitivity of detection of tetracycline was five times higher than that of oxytetracycline and of terramycin, and 22 times higher than that of demeclocycline. A shelf-life of the prepared sensor was more than six months and was used for detection in spiked honey samples. These results open the way to having continuous monitoring sensors with a high detection capacity, are easy to clean, avoid the use of antibodies, and produce a direct measurement.


Assuntos
Oxitetraciclina , Plastificantes , Tetraciclina , Antibacterianos , Microeletrodos , Anticorpos
6.
Anal Chim Acta ; 1161: 338468, 2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-33896556

RESUMO

According to the European statistics, approximately 26 million patients worldwide suffer from heart failure (HF), and this number seems to be steadily increasing. Inflammation plays a central role in the development of HF, and the pro-inflammatory cytokine Tumor necrosis factor-α (TNF-α) represents inflammation gold-standard biomarker. Early detection plays a crucial role for the prognosis and treatment of HF. An Ion Sensitive Field Effect Transistor (ISFET) based on silicon nitride transducer and biofunctionalized with anti-TNF-α antibody for label-free detection of salivary TNF-α is proposed. Electrochemical impedance spectroscopy (EIS) was used for TNF-α detection. Our ImmunoFET offered a detection limit of 1 pg mL-1, with an analytical reproducibility expressed by a coefficient of variance (CV) resulted < 10% for the analysis of saliva samples, and an analyte recovery of 94 ± 6%. In addition, it demonstrated high selectivity when compared to other HF biomarkers such as Inteleukin-10, N-terminal pro B-type natriuretic peptide, and Cortisol. Finally, ImmunoFET accuracy in determining the unknown concentration of TNF-α was successfully tested in saliva samples by performing standard addition method. The proposed ImmunoFET showed great promise as a complementary tool for biomedical application for HF monitoring by a non-invasive, rapid and accurate assessment of TNF-α.


Assuntos
Técnicas Biossensoriais , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Humanos , Imunoensaio , Reprodutibilidade dos Testes , Saliva , Compostos de Silício , Fator de Necrose Tumoral alfa
7.
Molecules ; 25(17)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32878151

RESUMO

Magnetic nanoparticles (MNPs) were synthesized using the colloidal co-precipitation method and further coated with silica using the Stöber process. These were functionalized with carboxylic and amine functionalities for further covalent immobilization of antibodies on these MNPs. The procedure for covalent immobilization of antibodies on MNPs was developed using 1-ethyl-3-(dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The evaluation of the efficiency of the coupling reaction was carried out by UV-vis spectrophotometry. The developed antibodies coupled to MNPs were tested for the pre-concentration of two biomarkers tumor necrosis factor alpha (TNF-α) and Interleukin-10 (IL-10). Both biomarkers were assessed in the matrix based on phosphate-buffered saline solution (PBS) and artificial saliva (AS) to carry out the demonstration of the format assay. Supernatants were used to determine the number of free biomarkers for both studies. Reduction of the nonspecific saliva protein adsorption on the surface of the complex antibodies-MNPs to levels low enough to allow the detection of biomarkers in complex media has been achieved.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Nanopartículas de Magnetita/química , Saliva Artificial/análise , Humanos , Nanopartículas de Magnetita/ultraestrutura , Modelos Teóricos , Estrutura Molecular , Tamanho da Partícula
8.
Electrophoresis ; 41(13-14): 1206-1224, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32347555

RESUMO

Superparamagnetic nanoparticles are attracting significant attention. Therefore, being explored in microsystems for a wide range of applications. Typical examples include lab-on-a-chip and microfluidics for synthesis, detection, separation, and transportation of different bioanalytes, such as biomolecules, cells, and viruses to develop portable, sensitive, and cost-effective biosensing systems. Particularly, microfluidic systems incorporated with magnetic nanoparticles and, in combination with magnetoresistive sensors, shift diagnostic and analytical methods to a microscale level. In this context, nanotechnology enables the miniaturization and integration of a variety of analytical functions in a single chip for manipulation, detection, and recognition of bioanalytes reliably and flexibly. In consideration of the above, recent development and benefits are elaborated herein to discuss the role of magnetic nanoparticles inside the microchannels to design highly efficient disposable point-of-care applications from transportation to the detection of bioanalytes.


Assuntos
Técnicas Biossensoriais , Nanopartículas de Magnetita , Técnicas Analíticas Microfluídicas , Dispositivos Lab-On-A-Chip , Nanotecnologia , Sistemas Automatizados de Assistência Junto ao Leito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA