Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 12(11): e0188146, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29161298

RESUMO

In vitro brain-on-a-chip platforms hold promise in many areas including: drug discovery, evaluating effects of toxicants and pathogens, and disease modelling. A more accurate recapitulation of the intricate organization of the brain in vivo may require a complex in vitro system including organization of multiple neuronal cell types in an anatomically-relevant manner. Most approaches for compartmentalizing or segregating multiple cell types on microfabricated substrates use either permanent physical surface features or chemical surface functionalization. This study describes a removable insert that successfully deposits neurons from different brain areas onto discrete regions of a microelectrode array (MEA) surface, achieving a separation distance of 100 µm. The regional seeding area on the substrate is significantly smaller than current platforms using comparable placement methods. The non-permanent barrier between cell populations allows the cells to remain localized and attach to the substrate while the insert is in place and interact with neighboring regions after removal. The insert was used to simultaneously seed primary rodent hippocampal and cortical neurons onto MEAs. These cells retained their morphology, viability, and function after seeding through the cell insert through 28 days in vitro (DIV). Co-cultures of the two neuron types developed processes and formed integrated networks between the different MEA regions. Electrophysiological data demonstrated characteristic bursting features and waveform shapes that were consistent for each neuron type in both mono- and co-culture. Additionally, hippocampal cells co-cultured with cortical neurons showed an increase in within-burst firing rate (p = 0.013) and percent spikes in bursts (p = 0.002), changes that imply communication exists between the two cell types in co-culture. The cell seeding insert described in this work is a simple but effective method of separating distinct neuronal populations on microfabricated devices, and offers a unique approach to developing the types of complex in vitro cellular environments required for anatomically-relevant brain-on-a-chip devices.


Assuntos
Encéfalo/citologia , Células Cultivadas/citologia , Técnicas de Cocultura/métodos , Neurônios/citologia , Potenciais de Ação/fisiologia , Animais , Linhagem da Célula/fisiologia , Técnicas de Cocultura/instrumentação , Microeletrodos , Ratos
2.
Analyst ; 138(13): 3692-6, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23689934

RESUMO

Detection of pathogens and relevant genetic markers using their nucleic acid signatures is extremely common due to the inherent specificity genomic sequences provide. One approach for assaying a sample simultaneously for many different targets is the DNA microarray, which consists of several million short nucleic acid sequences (probes) bound to an inexpensive transparent substrate. Typically, complex samples hybridize to the microarray and the pattern of fluorescing probes on the microarray's surface identifies the detected targets. In the case of evolving or newly emergent organisms, a hybridization pattern can occur that differs from any previously known sources. When this happens it can be useful to recover the hybridized DNA from the binding locations of interest for sequencing. Here we present the novel utilization of a focused Infrared (IR) laser to heat user-selected spots on the DNA microarray surface, causing only localized dehybridization and recovery of the desired DNA into an elution buffer where it is available for subsequent amplification or sequencing. The introduction of a focused dehybridization method for spots of interest suppresses the amount of background DNA to be analyzed from downstream processes, and should reduce subsequent sequence assembly errors. This technique could also be applied to high-density protein microarrays where the desire to locally heat spots for release of bound molecules is desired.


Assuntos
DNA/química , DNA/genética , Lasers , Hibridização de Ácido Nucleico/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Calibragem , Técnicas Analíticas Microfluídicas , Sondas de Oligonucleotídeos/química , Sondas de Oligonucleotídeos/genética , Reação em Cadeia da Polimerase , RNA Viral/química , RNA Viral/genética
3.
Analyst ; 136(18): 3707-12, 2011 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-21796289

RESUMO

Nucleic acid amplification is enormously useful to the biotechnology and clinical diagnostic communities; however, to date point-of-use PCR has been hindered by thermal cycling architectures and protocols that do not allow for near-instantaneous results. In this work we demonstrate PCR amplification of synthetic SARS respiratory pathogenic targets and bacterial genomic DNA in less than three minutes in a hardware configuration utilizing convenient sample loading and disposal. Instead of sample miniaturization techniques, near-instantaneous heating and cooling of 5 µL reaction volumes is enabled by convective heat transfer of a thermal fluid through porous media combined with an integrated electrical heater. This method of rapid heat transfer has enabled 30 cycles of PCR amplification to be completed in as little as two minutes and eighteen seconds. Surprisingly, multiple enzymes have been shown to work at these breakthrough speeds on our system. A tool for measuring enzyme kinetics now exists and can allow polymerase optimization through directed evolution studies. Pairing this instrument technology with modified polymerases should result in a new paradigm for high-throughput, ultra-fast PCR and will hopefully improve our ability to quickly respond to the next viral pandemic.


Assuntos
Reação em Cadeia da Polimerase/métodos , DNA Bacteriano/análise , DNA Viral/análise , Erwinia/genética , Miniaturização , Reação em Cadeia da Polimerase/instrumentação , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/genética , Fatores de Tempo
4.
AJNR Am J Neuroradiol ; 28(5): 872-4, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17494660

RESUMO

A prototype endovascular electromechanical clot-extraction device was fabricated using a combination of shape memory polymer and shape memory nickel-titanium alloy (nitinol). Five embolic vascular occlusions were created in 4 rabbits by injecting thermally coagulated blood through a 4F catheter in the common carotid artery. Angiography immediately after clot injection showed complete or partial occlusion of the common carotid artery. Posttreatment angiography showed complete (2/5), partial (2/5), or no (1/5) restoration of blood flow.


Assuntos
Embolectomia/instrumentação , Embolectomia/métodos , Embolia Intracraniana/terapia , Doença Aguda , Ligas , Animais , Angiografia Cerebral , Modelos Animais de Doenças , Desenho de Equipamento , Embolia Intracraniana/diagnóstico por imagem , Polímeros , Coelhos
5.
Anal Chem ; 76(14): 4011-6, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15253636

RESUMO

We have fabricated a low-cost disposable polymerase chain reaction thermal chamber that uses buoyancy forces to move the sample solution between the different temperatures necessary for amplification. Three-dimensional, unsteady finite element modeling and a simpler 1-D steady-state model are used together with digital particle image velocimetry data to characterize the flow within the device. Biological samples have been amplified using this novel thermal chamber. Time for amplification is less than 30 min. More importantly, an analysis of the energy consumption shows significant improvements over current technology.


Assuntos
Reação em Cadeia da Polimerase/instrumentação , Fontes de Energia Elétrica , Reação em Cadeia da Polimerase/métodos , Fatores de Tempo
7.
Clin Chem ; 44(10): 2191-4, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9761255

RESUMO

An array of PCR microchips for rapid, parallel testing of samples for pathogenic microbes is described. The instrument, called the Advanced Nucleic Acid Analyzer (ANAA), utilizes 10 silicon reaction chambers with thin-film resistive heaters and solid-state optics. Features of the system include efficient heating and real-time monitoring, low power requirements for battery operation, and no moving parts for reliability and ruggedness. We analyzed cultures of Erwinia herbicola vegetative cells, Bacillus subtilis spores, and MS2 virions, which simulated pathogenic microbes such as Yersinia pestis, Bacillus anthracis spores, and Venezuelan equine encephalitis, respectively. Detection of microbes was achieved in as little as 16 min with detection limits of 10(5)-10(7) organisms/L (10(2)-10(4) organisms/mL).


Assuntos
DNA Bacteriano/análise , DNA Viral/análise , Reação em Cadeia da Polimerase/instrumentação , Bacillus subtilis/genética , Bacillus subtilis/patogenicidade , Erwinia/genética , Erwinia/patogenicidade , Fluorometria , Levivirus/genética , Levivirus/patogenicidade , Miniaturização , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA