Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(10)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38593817

RESUMO

Objective. Severe radiation-induced lymphopenia occurs in 40% of patients treated for primary brain tumors and is an independent risk factor of poor survival outcomes. We developed anin-silicoframework that estimates the radiation doses received by lymphocytes during volumetric modulated arc therapy brain irradiation.Approach. We implemented a simulation consisting of two interconnected compartmental models describing the slow recirculation of lymphocytes between lymphoid organs (M1) and the bloodstream (M2). We used dosimetry data from 33 patients treated with chemo-radiation for glioblastoma to compare three cases of the model, corresponding to different physical and biological scenarios: (H1) lymphocytes circulation only in the bloodstream i.e. circulation inM2only; (H2) lymphocytes recirculation between lymphoid organs i.e. circulation inM1andM2interconnected; (H3) lymphocytes recirculation between lymphoid organs and deep-learning computed out-of-field (OOF) dose to head and neck (H&N) lymphoid structures. A sensitivity analysis of the model's parameters was also performed.Main results. For H1, H2 and H3 cases respectively, the irradiated fraction of lymphocytes was 99.8 ± 0.7%, 40.4 ± 10.2% et 97.6 ± 2.5%, and the average dose to irradiated pool was 309.9 ± 74.7 mGy, 52.6 ± 21.1 mGy and 265.6 ± 48.5 mGy. The recirculation process considered in the H2 case implied that irradiated lymphocytes were irradiated in the field only 1.58 ± 0.91 times on average after treatment. The OOF irradiation of H&N lymphoid structures considered in H3 was an important contribution to lymphocytes dose. In all cases, the estimated doses are low compared with lymphocytes radiosensitivity, and other mechanisms could explain high prevalence of RIL in patients with brain tumors.Significance. Our framework is the first to take into account OOF doses and recirculation in lymphocyte dose assessment during brain irradiation. Our results demonstrate the need to clarify the indirect effects of irradiation on lymphopenia, in order to potentiate the combination of radio-immunotherapy or the abscopal effect.


Assuntos
Neoplasias Encefálicas , Linfócitos , Dosagem Radioterapêutica , Humanos , Linfócitos/efeitos da radiação , Linfócitos/citologia , Neoplasias Encefálicas/radioterapia , Radiometria , Doses de Radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Encéfalo/efeitos da radiação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38554830

RESUMO

PURPOSE: The dose deposited outside of the treatment field during external photon beam radiation therapy treatment, also known as out-of-field dose, is the subject of extensive study as it may be associated with a higher risk of developing a second cancer and could have deleterious effects on the immune system that compromise the efficiency of combined radio-immunotherapy treatments. Out-of-field dose estimation tools developed today in research, including Monte Carlo simulations and analytical methods, are not suited to the requirements of clinical implementation because of their lack of versatility and their cumbersome application. We propose a proof of concept based on deep learning for out-of-field dose map estimation that addresses these limitations. METHODS AND MATERIALS: For this purpose, a 3D U-Net, considering as inputs the in-field dose, as computed by the treatment planning system, and the patient's anatomy, was trained to predict out-of-field dose maps. The cohort used for learning and performance evaluation included 3151 pediatric patients from the FCCSS database, treated in 5 clinical centers, whose whole-body dose maps were previously estimated with an empirical analytical method. The test set, composed of 433 patients, was split into 5 subdata sets, each containing patients treated with devices unseen during the training phase. Root mean square deviation evaluated only on nonzero voxels located in the out-of-field areas was computed as performance metric. RESULTS: Root mean square deviations of 0.28 and 0.41 cGy/Gy were obtained for the training and validation data sets, respectively. Values of 0.27, 0.26, 0.28, 0.30, and 0.45 cGy/Gy were achieved for the 6 MV linear accelerator, 16 MV linear accelerator, Alcyon cobalt irradiator, Mobiletron cobalt irradiator, and betatron device test sets, respectively. CONCLUSIONS: This proof-of-concept approach using a convolutional neural network has demonstrated unprecedented generalizability for this task, although it remains limited, and brings us closer to an implementation compatible with clinical routine.

3.
Front Oncol ; 13: 1197079, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228501

RESUMO

A growing body of scientific evidence indicates that exposure to low dose ionizing radiation (< 2 Gy) is associated with a higher risk of developing radio-induced cancer. Additionally, it has been shown to have significant impacts on both innate and adaptive immune responses. As a result, the evaluation of the low doses inevitably delivered outside the treatment fields (out-of-field dose) in photon radiotherapy is a topic that is regaining interest at a pivotal moment in radiotherapy. In this work, we proposed a scoping review in order to identify evidence of strengths and limitations of available analytical models for out-of-field dose calculation in external photon beam radiotherapy for the purpose of implementation in clinical routine. Papers published between 1988 and 2022 proposing a novel analytical model that estimated at least one component of the out-of-field dose for photon external radiotherapy were included. Models focusing on electrons, protons and Monte-Carlo methods were excluded. The methodological quality and potential limitations of each model were analyzed to assess their generalizability. Twenty-one published papers were selected for analysis, of which 14 proposed multi-compartment models, demonstrating that research efforts are directed towards an increasingly detailed description of the underlying physical phenomena. Our synthesis revealed great inhomogeneities in practices, in particular in the acquisition of experimental data and the standardization of measurements, in the choice of metrics used for the evaluation of model performance and even in the definition of regions considered out-of-the-field, which makes quantitative comparisons impossible. We therefore propose to clarify some key concepts. The analytical methods do not seem to be easily suitable for massive use in clinical routine, due to the inevitable cumbersome nature of their implementation. Currently, there is no consensus on a mathematical formalism that comprehensively describes the out-of-field dose in external photon radiotherapy, partly due to the complex interactions between a large number of influencing factors. Out-of-field dose calculation models based on neural networks could be promising tools to overcome these limitations and thus favor a transfer to the clinic, but the lack of sufficiently large and heterogeneous data sets is the main obstacle.

4.
Int J Radiat Oncol Biol Phys ; 108(3): 813-823, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32417412

RESUMO

PURPOSE: This study aims to evaluate the impact of key parameters on the pseudo computed tomography (pCT) quality generated from magnetic resonance imaging (MRI) with a 3-dimensional (3D) convolutional neural network. METHODS AND MATERIALS: Four hundred two brain tumor cases were retrieved, yielding associations between 182 computed tomography (CT) and T1-weighted MRI (T1) scans, 180 CT and contrast-enhanced T1-weighted MRI (T1-Gd) scans, and 40 CT, T1, and T1-Gd scans. A 3D CNN was used to map T1 or T1-Gd onto CT scans and evaluate the importance of different components. First, the training set size's influence on testing set accuracy was assessed. Moreover, we evaluated the MRI sequence impact, using T1-only and T1-Gd-only cohorts. We then investigated 4 MRI standardization approaches (histogram-based, zero-mean/unit-variance, white stripe, and no standardization) based on training, validation, and testing cohorts composed of 242, 81, and 79 patients cases, respectively, as well as a bias field correction influence. Finally, 2 networks, namely HighResNet and 3D UNet, were compared to evaluate the architecture's impact on the pCT quality. The mean absolute error, gamma indices, and dose-volume histograms were used as evaluation metrics. RESULTS: Generating models using all the available cases for training led to higher pCT quality. The T1 and T1-Gd models had a maximum difference in gamma index means of 0.07 percentage point. The mean absolute error obtained with white stripe was 78 ± 22 Hounsfield units, which slightly outperformed histogram-based, zero-mean/unit-variance, and no standardization (P < .0001). Regarding the network architectures, 3%/3 mm gamma indices of 99.83% ± 0.19% and 99.74% ± 0.24% were obtained for HighResNet and 3D UNet, respectively. CONCLUSIONS: Our best pCTs were generated using more than 200 samples in the training data set. Training with T1 only and T1-Gd only did not significantly affect performance. Regardless of the preprocessing applied, the dosimetry quality remained equivalent and relevant for potential use in clinical practice.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Aprendizado Profundo , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/normas , Redes Neurais de Computação , Radiometria , Radioterapia/normas , Estudos Retrospectivos , Crânio/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA