Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pharmaceutics ; 15(11)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38004590

RESUMO

This research aims to investigate the agglomeration processes of magnetoresponsive functionalized nanocluster suspensions in a magnetic field, as well as how these structures impact the behaviour of these suspensions in biomedical applications. The synthesis, shape, colloidal stability, and magnetic characteristics of PEG-functionalized nanoclusters are described in this paper. Experiments using TEM, XPS, dynamic light scattering (DLS), VSM, and optical microscopy were performed to study chain-like agglomeration production and its influence on colloidal behaviour in physiologically relevant suspensions. The applied magnetic field aligns the magnetic moments of the nanoclusters. It provides an attraction between neighbouring particles, resulting in the formation of chains, linear aggregates, or agglomerates of clusters aligned along the applied field direction. Optical microscopy has been used to observe the creation of these aligned linear formations. The design of chain-like structures can cause considerable changes in the characteristics of ferrofluids, ranging from rheological differences to colloidal stability changes.

2.
Diagnostics (Basel) ; 13(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36673141

RESUMO

OBJECTIVE: Omentum involvement resulting from uterine perforation is a rare complication following intrauterine procedures that might require immediate intervention due to severe ischemic consequences. This review examines the prevalence of this complication, risk factors, the mode and timing of diagnosis, the proper management and the outcome. METHODS: A systematic literature search was conducted on PubMed, PubMed Central and Scopus using uterine perforation, D&C, abortion and omentum as keywords. The exclusion criteria included the presence of the uterus or placenta's malignancy and uterine perforation following delivery or caused by an intrauterine device. RESULTS: The review included 11 articles from 133 screened papers. We identified 12 cases that three evaluators further analysed. We also present the case of a 32-year-old woman diagnosed with uterine perforation and omentum involvement. The patient underwent a hysteroscopic procedure with resectioning the protruding omentum into the uterine cavity, followed by intrauterine device insertion. CONCLUSION: This paper highlights the importance of a comprehensive gynaecological evaluation following a D&C procedure that includes a thorough clinical examination and a detailed ultrasound assessment. Healthcare providers should not overlook the diagnosis of omentum involvement in the presence of a history of intrauterine procedures.

3.
Micromachines (Basel) ; 13(11)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36363839

RESUMO

This study presents preliminary computational and experimental findings on two alternative permanent magnet configurations helpful for magnetic drug administration in vivo. A numerical simulation and a direct experimental measurement of the magnetic induction on the magnet system's surface were used to map the magnetic field. In addition, the ferrite-type (grade Y35) and permanent neodymium magnets (grade N52) to produce powerful magnetic forces were also examined analytically and quantitatively. Ansys-Maxwell software and Finite Element Method Magnetism (FEMM) version 4.2 were used for all numerical computations in the current investigation. For both magnets, the generated magnetic fields were comparatively studied for targeting Fe particles having a diameter of 6 µm. The following findings were drawn from the present investigation: (i) the particle deposition on the vessel wall is greatly influenced by the intensity of the magnetic field, the magnet type, the magnet size, and the magnetic characteristics of the micro-sized magnetic particles (MSMPs); (ii) ferrite-type magnets might be employed to deliver magnetoresponsive particles to a target location, even if they are less powerful than neodymium magnets; and (iii) the results from the Computational Fluid Dynamics( CFD) models agree well with the measured magnetic field induction, magnetic field strength, and their fluctuation with the distance from the magnet surface.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36078626

RESUMO

The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic significantly impacted the general population's health. At times, the infection has unfavorably influenced pregnancy evolution and the result of birth. However, vertical transmission of the virus is rare and generates controversial discussions. The study aimed to highlight the clinical, laboratory, and imaging findings of pregnant women with confirmed Coronavirus Disease 2019 (COVID-19) with possible vertical transmission and identify possible factors that encourage vertical transmission. Between 1 April 2020 and 31 December 2021, 281 pregnant women diagnosed with COVID-19 gave birth in the Obstetrics and Gynecology Departments of the tertiary unit of County Emergency Clinical Hospital from Timisoara. Three newborns (1.06%) tested positive. The characteristic of these three cases was described as a short series. In two cases, the patients were asymptomatic. In one case, the patient developed a mild form of COVID-19 with a favorable evolution in all cases. We did not identify the presence of smoking history, vaccine before admission, atypical presentation, fever, or chest X-ray abnormalities. We note possible factors that encourage vertical transmission: Pregnancy-induced hypertension, thrombophilia, asymptomatic cough, an asymptomatic or mild form of the disease, a ruptured membrane, and cesarean. The laboratory results highlight the inconstant presence of some changes found in the list of potential predictors of the severity of the infection: Lymphopenia, high values of C-reactive protein, D-dimer, fibrinogen, platelets, Aspartate Aminotransferase, Lactate dehydrogenase, and ferritin. The study's conclusion of this small group suggests that there may have been an intrauterine infection in late pregnancy and described characteristics of the pregnant women. Possible risk factors that could encourage vertical transmission have been identified.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Feminino , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Gravidez , Complicações Infecciosas na Gravidez/prevenção & controle , Resultado da Gravidez , Gestantes , SARS-CoV-2
5.
Pharmaceutics ; 14(9)2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36145671

RESUMO

Drug therapy for vascular disease has been promoted to inhibit angiogenesis in atherosclerotic plaques and prevent restenosis following surgical intervention. This paper investigates the arterial depositions and distribution of PEG-functionalized magnetic nanocomposite clusters (PEG_MNCs) following local delivery in a stented artery model in a uniform magnetic field produced by a regionally positioned external permanent magnet; also, the PEG_MNCs aggregation or chain formation in and around the implanted stent. The central concept is to employ one external permanent magnet system, which produces enough magnetic field to magnetize and guide the magnetic nanoclusters in the stented artery region. At room temperature (25 °C), optical microscopy of the suspension model's aggregation process was carried out in the external magnetic field. According to the optical microscopy pictures, the PEG_MNC particles form long linear aggregates due to dipolar magnetic interactions when there is an external magnetic field. During magnetic particle targeting, 20 mL of the model suspensions are injected (at a constant flow rate of 39.6 mL/min for the period of 30 s) by the syringe pump in the mean flow (flow velocity is Um = 0.25 m/s, corresponding to the Reynolds number of Re = 232) into the stented artery model. The PEG_MNC clusters are attracted by the magnetic forces (generated by the permanent external magnet) and captured around the stent struts and the bottom artery wall before and inside the implanted stent. The colloidal interaction among the MNC clusters was investigated by calculating the electrostatic repulsion, van der Waals and magnetic dipole-dipole energies. The current work offers essential details about PEG_MNCs aggregation and chain structure development in the presence of an external magnetic field and the process underlying this structure formation.

6.
J Pers Med ; 12(9)2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36143287

RESUMO

The complicated abdominal aorta and its branches are a portion of the circulatory system prone to developing atherosclerotic plaque and aneurysms. These disorders are closely connected to the changing blood flow environment that the area's complicated architecture produces (between celiac artery and iliac artery bifurcation); this phenomenon is widespread at arterial bifurcations. Based on computed tomography angiography (CTA) scans, this current work offers a numerical analysis of a patient-specific reconstruction of the abdominal aorta and its branches to identify and emphasize the most likely areas to develop atherosclerosis. The simulations were run following the heart cycle and under physiological settings. The wall shear stress (WSS), velocity field, and streamlines were examined. According to the findings, complex flow is primarily present at the location of arterial bifurcations, where abnormal flow patterns create recirculation zones with low and fluctuating WSS (<0.5 Pa), which are known to affect endothelial homeostasis and cause adverse vessel remodeling. The study provides a patient-specific hemodynamic analysis model, which couples in vivo CT imaging with in silico simulation under physiological circumstances. The study offers quantitative data on the range fluctuations of important hemodynamic parameters, such as WSS and recirculation region expansion, which are directly linked to the onset and progression of atherosclerosis. The findings could also help drug targeting at this vascular level by understanding blood flow patterns in the abdominal aorta and its branches.

7.
Diagnostics (Basel) ; 12(7)2022 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-35885572

RESUMO

The Coronavirus disease 2019 (COVID-19) pandemic has exposed the vulnerable neonatal population to unknown risks. Given that herd immunity is has not been reached, the entire population is susceptible to Severe Acute Respiratory Syndrome Coronavirus 2 Virus(SARS-CoV-2) infection. The arising concern about the vertical transmission of neonatal complications caused by the novel coronavirus is a continuous challenge for managing newborns, considering the rare cases and unclear guidelines. Therefore, a retrospective study was conducted in a tertiary unit from Timisoara, Romania. Of the 283 newborns born during the study period, only 3 neonates were diagnosed with SARS-CoV-2 infection in the first 24 h of life (DOL-0). The present study plans to identify the findings, including clinical features, laboratory characteristics, and outcomes of newborns with vertical transmission of SARS-CoV-2. All infected neonates were confirmed with COVID-19 by Reverse-Transcriptase Polymerase Chain Reaction (RT-PCR) from nasal aspirates and were isolated in the neonatology department. They were the first and the only neonate infected at birth from the West part of Romania. The clinical findings were unremarkable except for one neonate who developed mild respiratory distress syndrome. Elevated IgG-specific anti-SARS-CoV-2 serum levels were found in one newborn. Swab samples in DOL-0 strengthened the awareness of vertical transmission, although peripartum SARS-CoV-2 infection does not seem responsible for severe symptoms. We conclude that vertical transmission is rare in late pregnancy. Even if the studied newborns showed mild forms of COVID-19, it is essential to note that newborns represent a particular category of patients. More studies are needed to complete the observations of this study.

8.
Molecules ; 24(13)2019 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-31324029

RESUMO

The present study investigated the possibilities and feasibility of drug targeting for an arterial bifurcation lesion to influence the host healing response. A micrometer sized iron particle was used only to model the magnetic carrier in the experimental investigation (not intended for clinical use), to demonstrate the feasibility of the particle targeting at the lesion site and facilitate the new experimental investigations using coated superparamagnetic iron oxide nanoparticles. Magnetic fields were generated by a single permanent external magnet (ferrite magnet). Artery bifurcation exerts severe impacts on drug distribution, both in the main vessel and the branches, practically inducing an uneven drug concentration distribution in the bifurcation lesion area. There are permanently positioned magnets in the vicinity of the bifurcation near the diseased area. The generated magnetic field induced deviation of the injected ferromagnetic particles and were captured onto the vessel wall of the test section. To increase the particle accumulation in the targeted region and consequently avoid the polypharmacology (interaction of the injected drug particles with multiple target sites), it is critical to understand flow hemodynamics and the correlation between flow structure, magnetic field gradient, and spatial position.


Assuntos
Artérias/fisiopatologia , Artérias/efeitos da radiação , Sistemas de Liberação de Medicamentos , Hemodinâmica/efeitos da radiação , Campos Magnéticos , Nanopartículas de Magnetita , Nanomedicina Teranóstica , Algoritmos , Angiografia , Artérias/anormalidades , Artérias/diagnóstico por imagem , Substitutos Sanguíneos , Hemodinâmica/efeitos dos fármacos , Modelos Biológicos , Tamanho da Partícula , Reologia
9.
Rom J Morphol Embryol ; 56(2 Suppl): 871-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26429189

RESUMO

Carcinoma of the Fallopian tube is the least frequent tumor of the female genital tract. The diagnosis is difficult but could be made more frequently if the causes of abnormal bleeding were thoroughly investigated by means of cytology and endometrial curettage. Treatment is by resection of the tumor, total hysterectomy, and bilateral salpingo-oophorectomy followed by chemotherapy. A 25-year-old patient, presented herself at the emergency room, accusing intense lower abdominal pains, accompanied by vaginal bleeding. The histological aspect corroborated with the Ki-67 index is strongly suggestive for a choriocarcinoma developed in a tubal ectopic pregnancy.


Assuntos
Coriocarcinoma/diagnóstico , Neoplasias das Tubas Uterinas/diagnóstico , Gravidez Tubária/diagnóstico , Adulto , Coriocarcinoma/complicações , Coriocarcinoma/tratamento farmacológico , Coriocarcinoma/cirurgia , Diagnóstico Diferencial , Neoplasias das Tubas Uterinas/complicações , Neoplasias das Tubas Uterinas/tratamento farmacológico , Neoplasias das Tubas Uterinas/patologia , Neoplasias das Tubas Uterinas/cirurgia , Feminino , Humanos , Gravidez , Complicações Neoplásicas na Gravidez , Trofoblastos/patologia
10.
Biomed Mater Eng ; 26 Suppl 1: S477-86, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26406039

RESUMO

Optimal graft design has been an objective of many researchers to find correlations between hemodynamics and graft failure. Compared to planar grafts, the helical graft configurations improve hemodynamic performance including the promotion of flow mixing and reduction of flow stagnation regions. In order to evaluate the advantages and disadvantages of the suggested helical type bypass graft model in comparison to a conventional bypass graft configuration, three experimental models were designed and evaluated. The character of complex vortex structures created in the area between the heel and the occluded section depends on the flow parameters (in the case of the straight graft). We have identified two vortices in the symmetrical plane (proximal and distal to the anastomosis). In the new design of the two-turn helical graft, the stagnation point is eliminated from the anastomoses at different time intervals compared to the conventional straight bypass model The present study indicated that the magnitude of the pressure drop along a helical graft was considerably increased compared to a traditional graft which, while still physiologically advantageous, can be surpassed by an optimal geometry model.


Assuntos
Prótese Vascular , Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/métodos , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Circulação Coronária , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Resultado do Tratamento
11.
Biomed Mater Eng ; 24(1): 323-34, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211913

RESUMO

In this study, effects of serial stenosis on coronary hemodynamics were investigated in the human right coronary artery (RCA) using blood flow analysis. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. Numerical analysis examined the effect of multiple serial stenoses on the hemodynamic characteristics such as flow separation, pressure drop and FFR. Pressure loss associated with flow expansion after each constriction was large. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. In two stenoses the corresponding pressure gradients werearound 30 mmHg and corresponded to the stenosis with FFR < 0.7 (associated to the sever stenosis). Severe stenosies caused large pressure drops across the throat. Blood flow distal to the stenosis was associated with fluctuations of the wall shear stress and vorticity.


Assuntos
Estenose Coronária/diagnóstico , Vasos Coronários/patologia , Hemodinâmica , Adulto , Angiografia , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Estenose Coronária/patologia , Humanos , Hidrodinâmica , Hipertensão/patologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Modelos Cardiovasculares , Pressão , Interpretação de Imagem Radiográfica Assistida por Computador , Resistência ao Cisalhamento , Estresse Mecânico , Tomografia Computadorizada por Raios X
12.
Biomed Mater Eng ; 24(1): 853-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211972

RESUMO

The long-term success of arterial bypass surgery is often limited by the progression of intimal hyperplasia at the anastomosis between the graft and the native artery. The experimental models were manufactured from glass tubing with constant internal diameter of 8 mm, fashioned into a straight configuration and helical configuration. The aim of this study was to determine the three-dimensional flow structures that occur at the proximal anastomosis under pulsatile flow conditions, to investigate the changes that resulted from variations in the anastomosis angle and flow division, and to establishing the major differences between the straight and helical graft. In the anastomosis domain, a strong region of recirculation is observed near the occluded end of the artery, which forces the flow to move into the perfused host coronary artery. The proximal portion of the host tube shows weak counter-rotating vortices on the symmetry plane. The exact locations and strengths of the vortices in this region are only weakly dependent on Re. A detailed comparison of experimentally measured axial velocity patterns for straight and helical grafts confirm the very strong nature of the secondary flows in the helical geometry. The helical configuration promotes the mixing effect of vortex motion such that the flow particles are mixed into the blood stream disal to the anastomotic junction.


Assuntos
Anastomose Cirúrgica/métodos , Prótese Vascular , Ponte de Artéria Coronária/métodos , Reologia , Coagulação Sanguínea , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Desenho de Equipamento , Vidro , Hemodinâmica , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Fluxo Pulsátil , Resistência ao Cisalhamento , Túnica Íntima/patologia , Enxerto Vascular/métodos
13.
J Clin Med Res ; 4(3): 177-89, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22719804

RESUMO

BACKGROUND: Blood flow analysis of the human right coronary artery (RCA) has been carried out to investigate the effects of serial stenosis on coronary hemodynamics. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. METHODS: A velocity waveform in the proximal RCA and a pressure waveform in the distal RCA of a patient with a severe stenosis were acquired with a catheter delivered wire probe and applied as boundary conditions. The numerical analysis examines closely the effect of a multiple serial stenosis on the hemodynamic characteristics such as flow separation, wall shear stress (WSS) and particle depositions. RESULTS AND CONCLUSIONS: Energy loss associated with such flow expansion after each constriction will be large and consequently the pressure drop will be higher. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. At the peak systole the WSS values reached 110 Pa in the stenosis with 28% diameter reduction and 210 Pa in the stenosis with 54% diameter reduction, which is high enough to damage the endothelial cells. However at the end of one cardiac cycle a percent of 1.4% (15 from 1063 particles release at the inlet section) remain inside the stenosed RCA.

14.
Artigo em Inglês | MEDLINE | ID: mdl-14663954

RESUMO

In the cardiovascular system, altered flow conditions--such as separation, flow reversal, and low or oscillatory shear stress areas--are recognized as important factors in the development of arterial disease. A detailed understanding of the local hemodynamics, of the effects of vascular wall modification on flow patterns, and of longterm adaptation of the system to surgical procedures can have useful clinical applications. In this context, the availability of effective and accurate numerical simulation tools could be a real breakthrough. The two-dimensional flow over a square-step can be regarded as a two-dimensional stenosis model from witch some information on the properties at arterial stenoses can be obtained.


Assuntos
Arteriopatias Oclusivas/fisiopatologia , Constrição Patológica/fisiopatologia , Arteriopatias Oclusivas/patologia , Constrição Patológica/patologia , Hemodinâmica , Humanos , Fluxo Sanguíneo Regional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA