Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Cardiovasc Transl Res ; 15(3): 666-675, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34782943

RESUMO

Optimal translocation patch width for functional mitral regurgitation (FMR) treatment was evaluated in an air-filled ex vivo system. FMR was created in 19 isolated swine hearts by annular dilation and papillary muscle displacement. Frustum-shaped pericardial patches of varying widths (Group 1 = 0.5 cm; Group 2 = 1.0 cm; Group 3 = 1.5 cm) were implanted and imaged via a 3D-structured light scanner. Median leaflet coaptation decreased (P < 0.001) from 5.5 ± 2.0 mm at baseline to 2.4 ± 1.3 mm following FMR creation. Translocation repair increased coaptation length over FMR levels by 2.2 mm in Group 1 (P < 0.001), 4.6 mm in Group 2 (P < 0.001), and 4.7 mm in Group 3 (P < 0.001). After repair, no significant differences were found between groups for annular height, circularity index, tenting height, tenting area, and non-coapting surface area. The supranormal coaptation and minimal valve geometric changes support using a 1.0- or 1.5-cm translocation patch for FMR treatment. Implantation of a 1.0-cm or 1.5-cm circumferential pericardial patch (mitral valve translocation) increases leaflet coaptation length without significantly altering valve geometry.


Assuntos
Insuficiência da Valva Mitral , Animais , Dilatação Patológica , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares , Suínos
2.
Ann Thorac Surg ; 112(6): 1946-1953, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33440174

RESUMO

BACKGROUND: Functional (secondary) mitral regurgitation (FMR) results from altered geometry of the mitral valve apparatus. Repair with restrictive mitral annuloplasty is associated with high rates of recurrent mitral regurgitation (MR). We developed a novel operative repair for FMR that translocates the intact mitral valve towards the apex. METHODS: The mitral valve was detached circumferentially and translocated into the ventricle with a frustum-shaped glutaraldehyde-treated autologous pericardial patch. Clinical and echocardiographic follow-up was performed. RESULTS: Fifteen consecutive patients with FMR (mean age, 59 years; 67% female) had mitral valve translocation between 2018 and 2020. Preoperative mean ejection fraction, left ventricular end-diastolic dimension, and systolic pulmonary artery pressure were 40% ± 11%, 59 ± 8 mm, and 49 ± 21 mm Hg, respectively; 33% had atrial fibrillation. Cardiomyopathy was ischemic in 4 and nonischemic in 11. Concomitant procedures included tricuspid valve operation (n = 8), coronary artery bypass grafting (n = 4), and atrial fibrillation ablation (n = 5). Post bypass transesophageal echocardiogram demonstrated none/trace MR in all patients and mean gradient of 3 mm Hg (interquartile range, 2-4 mm Hg). Mean leaflet extent of coaptation was 14 ± 2 mm (range, 11-17 mm). There was no postoperative mortality, stroke, or renal failure. Predismissal echocardiography showed none/trace MR in 14 patients and mild MR in 1. One patient underwent successful late rerepair of a suture line leak. Twelve patients were alive at latest follow-up and MR at 1 and 6 months was mild or less in all patients with mean leaflet extent of coaptation of 14 ± 2 mm (range, 12-16 mm) at 6 months. CONCLUSIONS: Mitral valve translocation creates a large surface of coaptation and effectively corrects FMR. Further study is needed to demonstrate the long-term durability and clinical utility of this operation.


Assuntos
Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Recidiva , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Innovations (Phila) ; 15(2): 138-141, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32107959

RESUMO

OBJECTIVE: Percutaneous femoral cannulation for venoarterial extracorporeal membrane oxygenation (ECMO) is commonly performed but percutaneous removal of arterial cannulas has not been broadly accepted. We hypothesized that a system that allows endovascular access to ECMO circuits along with the MANTA® large-bore vascular closure device could be used to successfully close arterial ECMO cannulation sites in a large animal model. METHODS: Yorkshire swine (40 to 60 kg, n = 2) were used for this study. In the first swine, the infrarenal abdominal aorta was exposed. The aorta was cannulated once using a 15 Fr cannula and twice with a 19 Fr arterial cannula. A novel adaptor system that facilitates endovascular access to ECMO circuits was connected, and a 0.035″ Benston wire was placed through the adaptor and guided into the aorta. The cannula was removed over the wire and manual pressure was applied. The MANTA® sheath was inserted over the wire followed by the closure unit and was deployed. The process was repeated at 2 separate sites. A similar experiment was performed in a second swine, but through a median sternotomy to cannulate the ascending aorta. RESULTS: Good hemostasis was achieved at all cannulation sites. Angiography demonstrated unobstructed flow across all closure sites with no evidence of extravasation. CONCLUSIONS: The data presented here support the use of the MANTA® vascular closure device for the closure of arterial cannulation sites following ECMO decannulation and demonstrates utility of a novel adaptor system for establishing endovascular access in this context.


Assuntos
Aorta/cirurgia , Cateterismo/instrumentação , Oxigenação por Membrana Extracorpórea/efeitos adversos , Artéria Femoral/cirurgia , Dispositivos de Oclusão Vascular/estatística & dados numéricos , Angiografia/métodos , Animais , Cânula , Cateterismo Periférico/métodos , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/métodos , Estudos de Viabilidade , Modelos Animais , Procedimentos Cirúrgicos sem Sutura/instrumentação , Suínos
4.
Infect Control Hosp Epidemiol ; 40(9): 1024-1029, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31256766

RESUMO

OBJECTIVE: To sustainably improve cleaning of high-touch surfaces (HTSs) in acute-care hospitals using a multimodal approach to education, reduction of barriers to cleaning, and culture change for environmental services workers. DESIGN: Prospective, quasi-experimental, before-and-after intervention study. SETTING: The study was conducted in 2 academic acute-care hospitals, 2 community hospitals, and an academic pediatric and women's hospital. PARTICIPANTS: Frontline environmental services workers. INTERVENTION: A 5-module educational program, using principles of adult learning theory, was developed and presented to environmental services workers. Audience response system (ARS), videos, demonstrations, role playing, and graphics were used to illustrate concepts of and the rationale for infection prevention strategies. Topics included hand hygiene, isolation precautions, personal protective equipment (PPE), cleaning protocols, and strategies to overcome barriers. Program evaluation included ARS questions, written evaluations, and objective assessments of occupied patient room cleaning. Changes in hospital-onset C. difficile infection (CDI) and methicillin-resistant S. aureus (MRSA) bacteremia were evaluated. RESULTS: On average, 357 environmental service workers participated in each module. Most (93%) rated the presentations as 'excellent' or 'very good' and agreed that they were useful (95%), reported that they were more comfortable donning/doffing PPE (91%) and performing hand hygiene (96%) and better understood the importance of disinfecting HTSs (96%) after the program. The frequency of cleaning individual HTSs in occupied rooms increased from 26% to 62% (P < .001) following the intervention. Improvement was sustained 1-year post intervention (P < .001). A significant decrease in CDI was associated with the program. CONCLUSION: A novel program that addressed environmental services workers' knowledge gaps, challenges, and barriers was well received and appeared to result in learning, behavior change, and sustained improvements in cleaning.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfecção/normas , Zeladoria Hospitalar , Controle de Infecções/normas , Capacitação em Serviço/métodos , Recursos Humanos em Hospital/educação , Infecções por Clostridium/prevenção & controle , Higiene das Mãos , Humanos , Equipamento de Proteção Individual , Estudos Prospectivos , Infecções Estafilocócicas/prevenção & controle
5.
Infect Control Hosp Epidemiol ; 37(12): 1492-1495, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27619896

RESUMO

In this study, we used an online survey to assess knowledge, attitudes, and practices related to environmental cleaning and other infection prevention strategies among environmental services workers (ESWs) at 5 hospitals. Our findings suggest that ESWs could benefit from additional education and feedback as well as new strategies to address workflow challenges. Infect Control Hosp Epidemiol 2016;1492-1495.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Conhecimentos, Atitudes e Prática em Saúde , Recursos Humanos em Hospital/psicologia , Desinfetantes/uso terapêutico , Resistência Microbiana a Medicamentos , Hospitais , Zeladoria Hospitalar , Humanos , Cidade de Nova Iorque , Projetos Piloto , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA