Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Bioeng Biotechnol ; 10: 957481, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36091458

RESUMO

Titanium nitride (TiN) is presented as an alternative plasmonic nanomaterial to the commonly used gold (Au) for its potential use in laser rewarming of cryopreserved biomaterials. The rewarming of vitrified, glass like state, cryopreserved biomaterials is a delicate process as potential ice formation leads to mechanical stress and cracking on a macroscale, and damage to cell walls and DNA on a microscale, ultimately leading to the destruction of the biomaterial. The use of plasmonic nanomaterials dispersed in cryoprotective agent solutions to rapidly convert optical radiation into heat, generally supplied by a focused laser beam, proposes a novel approach to overcome this difficulty. This study focuses on the performance of TiN nanoparticles (NPs), since they present high thermal stability and are inexpensive compared to Au. To uniformly warm up the nanomaterial solutions, a beam splitting laser system was developed to heat samples from multiple sides with equal beam energy distribution. In addition, uniform laser warming requires equal distribution of absorption and scattering properties in the nanomaterials. Preliminary results demonstrated higher absorption but less scattering in TiN NPs than Au nanorods (GNRs). This led to the development of TiN clusters, synthetized by nanoparticle agglomeration, to increase the scattering cross-section of the material. Overall, this study analyzed the heating rate, thermal efficiency, and heating uniformity of TiN NPs and clusters in comparison to GNRs at different solution concentrations. TiN NPs and clusters demonstrated higher heating rates and solution temperatures, while only clusters led to a significantly improved uniformity in heating. These results highlight a promising alternative plasmonic nanomaterial to rewarm cryopreserved biological systems in the future.

2.
J Biomed Mater Res A ; 109(12): 2483-2492, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34096159

RESUMO

In this work, we present an extensive comparative study between novel titanium nitride nanoparticles (TiN NPs) and commercial gold nanorods (GNR), both dispersed in water and exposed to a pulsed laser-induced cavitation process. The optical density, shockwave emission, and bubble formation of these solutions were investigated using shadowgraphy, spatial transmittance modulation, and acoustic measurements. TiN nanoparticle solutions exhibited high stability undser a periodic nanosecond pulsed-laser irradiation, making these nanomaterials promising agents for high-power applications. In addition, they demonstrated a stronger nonlinear absorption compared to the GNR solutions, and plasma formation at lower laser energies. This study advances our understanding of the optical properties of TiN and discusses significant differences compared to gold, with important implications for future applications of this material in water treatment, nonlinear signal converting, and laser-induced cavitation for medical implementations, among others.


Assuntos
Ouro/química , Lasers , Nanopartículas Metálicas , Nanotubos/química , Titânio/química , Microscopia Eletrônica de Varredura , Dinâmica não Linear , Tamanho da Partícula , Soluções , Propriedades de Superfície
3.
J Biomed Opt ; 22(10): 1-9, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29030942

RESUMO

This is a study motivated by the need to develop a needle-free device for eliminating major global healthcare problems caused by needles. The generation of liquid jets by means of a continuous-wave laser, focused into a light absorbing solution, was studied with the aim of developing a portable and affordable jet injector. We designed and fabricated glass microfluidic devices, which consist of a chamber where thermocavitation is created and a tapered channel. The growth of a vapor bubble displaces and expels the liquid through the channel as a fast traveling jet. Different parameters were varied with the purpose of increasing the jet velocity. The velocity increases with smaller channel diameters and taper ratios, whereas larger chambers significantly reduce the jet speed. It was found that the initial position of the liquid-air meniscus interface and its dynamics contribute to increased jet velocities. A maximum velocity of 94±3 m/s for a channel diameter of D=120 µm, taper ratio n=0.25, and chamber length E=200 µm was achieved. Finally, agarose gel-based skin phantoms were used to demonstrate the potential of our devices to penetrate the skin. The maximum penetration depth achieved was ∼1 mm, which is sufficient to penetrate the stratum corneum and for most medical applications. A meta-analysis shows that larger injection volumes will be required as a next step to medical relevance for laser-induced jet injection techniques in general.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Injeções a Jato , Lasers , Desenho de Equipamento , Gases , Géis , Humanos , Microfluídica , Agulhas , Imagens de Fantasmas , Sefarose/química , Pele
4.
Biomicrofluidics ; 10(1): 014104, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26858816

RESUMO

We designed and built a microfluidic device for the generation of liquid jets produced by thermocavitation. A continuous wave (CW) laser was focused inside a micro-chamber filled with a light-absorbing solution to create a rapidly expanding vapor bubble. The chamber is connected to a micro-channel which focuses and ejects the liquid jet through the exit. The bubble growth and the jet velocity were measured as a function of the devices geometry (channel diameter D and chamber width A). The fastest jets were those for relatively large chamber size with respect to the channel diameter. Elongated and focused jets up to 29 m/s for a channel diameter of [Formula: see text] and chamber size of [Formula: see text] were obtained. The proposed CW laser-based device is potentially a compact option for a practical and commercially feasible needle-free injector.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA