Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 147: 2-12, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28912047

RESUMO

The need for investigating alcohol abuse by means of objective tools is worldwide accepted. Among the currently available biomarkers of chronic alcohol abuse, carbohydrate-deficient transferrin (CDT) is one of the most used indicator, mainly because of its high specificity. However, some CDT analytical and interpretation aspects are still under discussion, as witnessed by numerous research papers and reviews. The present article presents a critical review of the literature on CDT appeared in the period from 2007 to 2017 (included). The article is organized in the following sections: (1) introduction, (2) pre-analytical aspects (3) analytical aspects (4) diagnostic aspects (5) concluding remarks. As many as 139 papers appeared in the international literature and retrieved by the search engines PubMed, Web of Science and Scopus are quoted.


Assuntos
Alcoolismo/diagnóstico , Biomarcadores/sangue , Transferrina/análogos & derivados , Alcoolismo/sangue , Cromatografia Líquida de Alta Pressão , Eletroforese Capilar , Humanos , Sensibilidade e Especificidade , Transferrina/análise
2.
Lab Anim ; 47(4): 291-300, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23836849

RESUMO

In vivo assessment of ventricular function in rodents has largely been restricted to transthoracic echocardiography (TTE). However 1.5 T cardiac magnetic resonance (CMR) and transoesophageal echocardiography (TOE) have emerged as possible alternatives. Yet, to date, no study has systematically assessed these three imaging modalities in determining ejection fraction (EF) in rats. Twenty rats underwent imaging four weeks after surgically-induced myocardial infarction. CMR was performed on a 1.5 T scanner, TTE was conducted using a 9.2 MHz transducer and TOE was performed with a 10 MHz intracardiac echo catheter. Correlation between the three techniques for EF determination and analysis reproducibility was assessed. Moderate-strong correlation was observed between the three modalities; the greatest between CMR and TOE (intraclass correlation coefficient (ICC) = 0.89), followed by TOE and TTE (ICC = 0.70) and CMR and TTE (ICC = 0.63). Intra- and inter-observer variations were excellent with CMR (ICC = 0.99 and 0.98 respectively), very good with TTE (0.90 and 0.89) and TOE (0.87 and 0.84). Each modality is a viable option for evaluating ventricular function in rats, however the high image quality and excellent reproducibility of CMR offers distinct advantages even at 1.5 T with conventional coils and software.


Assuntos
Ecocardiografia Transesofagiana/veterinária , Ecocardiografia/veterinária , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética/veterinária , Função Ventricular , Animais , Ventrículos do Coração/diagnóstico por imagem , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA