Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
medRxiv ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38168197

RESUMO

Importance: Obtaining high-quality samples to diagnose streptococcal pharyngitis in pediatric patients is challenging due to discomfort associated with traditional pharyngeal swabs. This may cause reluctance to go to the clinic, inaccurate diagnosis, or inappropriate treatment for children with sore throat. Objective: Determine the efficacy of using CandyCollect, a lollipop-inspired open-microfluidic pathogen collection device, to capture Group A Streptococcus (GAS) and compare user preference for CandyCollect, conventional pharyngeal swabs, or mouth swabs among children with pharyngitis and their caregivers. Design: Participants of this cohort study were recruited over a 7-month period in 2022 - 2023. Setting: This study was conducted at an ambulatory care clinic that serves pediatric patients in the Madison, Wisconsin, metropolitan area. Participants: Study participants were diagnosed with GAS pharyngitis using a traditional pharyngeal swab via rapid antigen detection test (RADT); those testing positive were approached or reached out to about participation in the study. A total of 74 caregiver/children dyads were contacted about the study: 23 declined to participate; 21 were not eligible; and 30 willing and eligible participants were admitted into the study. A caregiver provided verbal consent and parental permission, and all children provided verbal assent. Immediately after the standard of care visit in which the throat swab was obtained, a research nurse guided participants through collecting oral samples: CandyCollect device and mouth swab (ESwab TM ). CandyCollect and mouth swab samples were analyzed for GAS by quantitative polymerase chain reaction (qPCR) at the University of Washington. Exposure: Detection of salivary GAS using qPCR analysis of samples obtained from CandyCollect devices and mouth swabs. Main Outcomes and Measures: The proportion of pediatric patients with GAS pharyngitis, as determined by a positive pharyngeal swab tested via a RADT, who were also positive using a CandyCollect and mouth swab analyzed by qPCR. Results: All child participants (30/30) were positive for GAS by qPCR on both the mouth swab and CandyCollect. Caregivers ranked CandyCollect as a good sampling method overall (27/30), and all caregivers (30/30) would recommend the CandyCollect for children 5 years and older. Twenty-three of 30 children "really like" the taste and 24/30 would prefer to use the CandyCollect if a future test was needed. All caregivers (30/30) and most children (28/30) would be willing to use the CandyCollect device at home. Conclusion and relevance: All participants tested positive for GAS on all three collection methods (pharyngeal swab, mouth swab, and CandyCollect). While both caregivers and children like the CandyCollect device, some caregivers would prefer a shorter collection time. Future work includes additional studies with larger cohorts presenting with pharyngitis of unknown etiology and shortening collection time, while maintaining the attractive form of the device. Trial Registration: Registry name: ClinicalTrials.gov ClinicalTrials.gov Identifier: NCT05175196 Weblink: https://classic.clinicaltrials.gov/ct2/show/NCT05175196. Key Points: Question: In pediatric patients with Group A Streptococcus pharyngitis, how do test results and user experience compare across three sampling methods-CandyCollect devices, mouth swabs, and pharyngeal swabs?Findings: In this cohort study of 30 children, aged 5-14 years, saliva samples were collected with CandyCollect devices and mouth swabs and analyzed via qPCR. The results show CandyCollect, a pathogen collection tool preferred by children, had 100% concordance with the results from pharyngeal swabs positive with a rapid antigen detection test performed as part of their clinical care.Meaning: With further development and testing, the CandyCollect device may potentially become an alternative sampling tool for the diagnosis of streptococcal pharyngitis.

2.
Clin Pharmacol Ther ; 115(1): 42-51, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37597239

RESUMO

Nirmatrelvir is a potent and selective severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) main protease inhibitor. Nirmatrelvir co-packaged with ritonavir (as PAXLOVID) received US Food and Drug Administration (FDA) Emergency Use Authorization (EUA) on December 22, 2021, as an oral treatment for coronavirus disease 2019 (COVID-19) and subsequent new drug application approval on May 25, 2023. Pharmacokinetic (PK) capillary blood sampling at-home using Tasso-M20 micro-volumetric sampling device was implemented in the program, including three phase II/III outpatient and several clinical pharmacology studies supporting the EUA. The at-home sampling complemented venous blood sampling procedures to enrich the PK dataset, to decrease the need for patients' site visit for PK sampling, and to allow different sampling approaches for flexibility and convenience. To demonstrate concordance/equivalence, bridging between venous plasma and Tasso dried blood results was conducted by comparing concentrations and derived PK parameters from both sampling approaches. In addition, a two-compartment population PK model was utilized to bridge the plasma and Tasso data by estimating the PK parameters using blood-to-plasma ratio as a slope parameter. Operational challenges were successfully managed to implement at-home PK sampling in global phase II/III trials. Sample quality was generally very good with less than 3% samples deemed as "not usable" from over 800 samples collected in all the studies. Experience gained from sites and patients will guide future broader implementations.


Assuntos
Lactamas , Ritonavir , Estados Unidos , Humanos , Leucina , Assistência Centrada no Paciente
3.
medRxiv ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-37873251

RESUMO

Background: Early host immunity to acute respiratory infections (ARIs) is heterogenous, dynamic, and critical to an individual's infection outcome. Due to limitations in sampling frequency/timepoints, kinetics of early immune dynamics in natural human infections remain poorly understood. In this nationwide prospective cohort study, we leveraged a self-blood collection tool (homeRNA) to profile detailed kinetics of the pre-symptomatic to convalescence host immunity to contemporaneous respiratory pathogens. Methods: We enrolled non-symptomatic adults with recent exposure to ARIs who subsequently tested negative (exposed-uninfected) or positive for respiratory pathogens. Participants self-collected blood and nasal swabs daily for seven consecutive days followed by weekly blood collection for up to seven additional weeks. Symptom burden was assessed during each collection. Nasal swabs were tested for SARS-CoV-2 and common respiratory pathogens. 92 longitudinal blood samples spanning the pre-shedding to post-acute phase of eight SARS-CoV-2-infected participants and 40 interval-matched samples from four exposed-uninfected participants were subjected to high-frequency longitudinal profiling of 773 host immune genes. Findings: Between June 2021 - April 2022, 68 participants across 26 U.S. states completed the study and self-collected a total of 691 and 466 longitudinal blood and nasal swab samples along with 688 symptom surveys. SARS-CoV-2 was detected in 17 out of 22 individuals with study-confirmed respiratory infection. With rapid dissemination of home self-collection kits, two and four COVID-19+ participants started collection prior to viral shedding and symptom onset, respectively, enabling us to profile detailed expression kinetics of the earliest blood transcriptional response to contemporaneous variants of concern. In pre-shedding samples, we observed transient but robust expression of T-cell response signatures, transcription factor complexes, prostaglandin biosynthesis genes, pyrogenic cytokines, and cytotoxic granule genes. This is followed by a rapid induction of many interferon-stimulated genes (ISGs), concurrent to onset of viral shedding and increase in nasal viral load. Finally, we observed increased expression of host defense peptides (HDPs) in exposed-uninfected individuals over the 4-week observational window. Interpretation: We demonstrated that unsupervised self-collection and stabilization of capillary blood can be applied to natural infection studies to characterize detailed early host immune kinetics at a temporal resolution comparable to that of human challenge studies. The remote (decentralized) study framework enables conduct of large-scale population-wide longitudinal mechanistic studies. Expression of cytotoxic/T-cell signatures in pre-shedding samples preceding expansion of innate ISGs suggests a potential role for T-cell mediated pathogen control during early infection. Elevated expression of HDPs in exposed-uninfected individuals warrants further validation studies to assess their potential role in protective immunity during pathogen exposure. Funding: This study was funded by R35GM128648 to ABT for in-lab developments of homeRNA, Packard Fellowship from the David and Lucile Packard Foundation to ABT, and R01AI153087 to AW.

4.
Phys Fluids (1994) ; 35(8): 082120, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37675268

RESUMO

The search for efficient capillary pumping has led to two main directions for investigation: first, assembly of capillary channels to provide high capillary pressures, and second, imbibition in absorbing fibers or paper pads. In the case of open microfluidics (i.e., channels where the top boundary of the fluid is in contact with air instead of a solid wall), the coupling between capillary channels and paper pads unites the two approaches and provides enhanced capillary pumping. In this work, we investigate the coupling of capillary trees-networks of channels mimicking the branches of a tree-with paper pads placed at the extremities of the channels, mimicking the small capillary networks of leaves. It is shown that high velocities and flow rates (7 mm/s or 13.1 µl/s) for more than 30 s using 50% (v/v) isopropyl alcohol, which has a 3-fold increase in viscosity in comparison to water; 6.5 mm/s or 12.1 µl/s for more than 55 s with pentanol, which has a 3.75-fold increase in viscosity in comparison to water; and >3.5 mm/s or 6.5 µl/s for more than 150 s with nonanol, which has a 11-fold increase in viscosity in comparison to water, can be reached in the root channel, enabling higher sustained flow rates than that of capillary trees alone.

5.
Anal Chem ; 95(27): 10211-10220, 2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-37364037

RESUMO

Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop-inspired saliva collection device .We showed that the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium (S. mutans or S. aureus) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n = 14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine.


Assuntos
Saliva , Staphylococcus aureus , Criança , Humanos , Adulto , Saliva/microbiologia , Manejo de Espécimes/métodos , Streptococcus mutans , Laboratórios
6.
Nat Rev Chem ; 7(6): 439-455, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37117816

RESUMO

Open droplet microfluidic systems manipulate droplets on the picolitre-to-microlitre scale in an open environment. They combine the compartmentalization and control offered by traditional droplet-based microfluidics with the accessibility and ease-of-use of open microfluidics, bringing unique advantages to applications such as combinatorial reactions, droplet analysis and cell culture. Open systems provide direct access to droplets and allow on-demand droplet manipulation within the system without needing pumps or tubes, which makes the systems accessible to biologists without sophisticated setups. Furthermore, these systems can be produced with simple manufacturing and assembly steps that allow for manufacturing at scale and the translation of the method into clinical research. This Review introduces the different types of open droplet microfluidic system, presents the physical concepts leveraged by these systems and highlights key applications.


Assuntos
Biologia , Microfluídica , Microfluídica/métodos
7.
bioRxiv ; 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-36711895

RESUMO

Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop inspired saliva collection device. 1 We showed the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium ( S. mutans or S. aureus ) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n=14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine.

8.
J Appl Lab Med ; 8(3): 535-550, 2023 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-36533519

RESUMO

BACKGROUND: Abnormal liver function is a common manifestation of human disease and may also occur in approved and investigational medications as drug-induced liver injury (DILI). Capillary blood collection devices may allow for more frequent and convenient measurement outside of the clinic. Validation of such approaches is lacking. METHODS: This prospective, biospecimens collection study evaluated the Tasso+ in patients with abnormal liver tests (NCT05259618). The primary objective was to define the concordance of alanine aminotransferase (ALT) obtained via Tasso+ compared to standard venipuncture. Secondary objectives included measurement of 14 other analytes and patient surveys. At the time of venipuncture, 2 Tasso+ samples were collected: one was centrifuged and shipped, and the other was refrigerated and shipped as whole blood. RESULTS: Thirty-six patients with elevated ALT values were enrolled. In total, 100 venipuncture, 50 Tasso+ centrifuged, and 48 Tasso+ whole blood samples were obtained. Tasso+ centrifuged samples demonstrated concordance correlation coefficients (CCC) of >0.99 for ALT, alkaline phosphatase (ALP), aspartate aminotransferase (AST), and total bilirubin and CCC >0.95 for albumin, chloride, enzymatic creatinine, serum glucose, magnesium, and phosphorus. Tasso+ whole blood showed CCC of >0.99 for AST, bilirubin total, and enzymatic creatinine and CCC >0.95 for ALT, ALP, albumin, magnesium, and phosphorus. Hemolysis was comparable across the 3 sample types, but its impact was reflected in the Tasso+ potassium data. Patient feedback indicated a very favorable patient experience. CONCLUSIONS: The capillary blood collection device, Tasso+, showed substantial to almost perfect concordance to standard venipuncture for measurement of abnormal liver function. Studies are ongoing to validate longitudinal sampling outside of the clinic. Clinicaltrials.gov Registration Number: NCT05259618.


Assuntos
Magnésio , Flebotomia , Humanos , Flebotomia/efeitos adversos , Estudos Prospectivos , Creatinina , Fosfatase Alcalina , Bilirrubina , Fígado , Fósforo , Albuminas
9.
Front Bioeng Biotechnol ; 10: 993872, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246374

RESUMO

Interactions between fibroblasts and immune cells play an important role in tissue inflammation. Previous studies have found that eosinophils activated with interleukin-3 (IL-3) degranulate on aggregated immunoglobulin G (IgG) and release mediators that activate fibroblasts in the lung. However, these studies were done with eosinophil-conditioned media that have the capacity to investigate only one-way signaling from eosinophils to fibroblasts. Here, we demonstrate a coculture model of primary normal human lung fibroblasts (HLFs) and human blood eosinophils from patients with allergy and asthma using an open microfluidic coculture device. In our device, the two types of cells can communicate via two-way soluble factor signaling in the shared media while being physically separated by a half wall. Initially, we assessed the level of eosinophil degranulation by their release of eosinophil-derived neurotoxin (EDN). Next, we analyzed the inflammation-associated genes and soluble factors using reverse transcription quantitative polymerase chain reaction (RT-qPCR) and multiplex immunoassays, respectively. Our results suggest an induction of a proinflammatory fibroblast phenotype of HLFs following the coculture with degranulating eosinophils, validating our previous findings. Additionally, we present a new result that indicate potential impacts of activated HLFs back on eosinophils. This open microfluidic coculture platform provides unique opportunities to investigate the intercellular signaling between the two cell types and their roles in airway inflammation and remodeling.

10.
Lab Chip ; 22(18): 3555-3564, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-35983761

RESUMO

Streptococcus pyogenes is a major human-specific bacterial pathogen and a common cause of a wide range of symptoms from mild infection such as pharyngitis (commonly called strep throat) to life-threatening invasive infection and post-infectious sequelae. Traditional methods for diagnosis include collecting a sample using a pharyngeal swab, which can cause discomfort and even discourage adults and children from seeking proper testing and treatment in the clinic. Saliva samples are an alternative to pharyngeal swabs. To improve the testing experience for strep throat, we developed a novel lollipop-inspired sampling platform (called CandyCollect) to capture bacteria in saliva. The device can be used in clinics or in the home and shipped back to a lab for analysis, integrating with telemedicine. CandyCollect is designed to capture bacteria on an oxygen plasma treated polystyrene surface embedded with flavoring substances to enhance the experience for children and inform the required time to complete the sampling process. In addition, the open channel structure prevents the tongue from scraping and removing the captured bacteria. The flavoring substances did not affect bacterial capture and the device has a shelf life of at least 2 months (with experiments ongoing to extend the shelf life). We performed a usability study with 17 participants who provided feedback on the device design and the dissolving time of the candy. This technology and advanced processing techniques, including polymerase chain reaction (PCR), will enable user-friendly and effective diagnosis of streptococcal pharyngitis.


Assuntos
Faringite , Infecções Estreptocócicas , Adulto , Criança , Humanos , Faringite/diagnóstico , Faringite/microbiologia , Reação em Cadeia da Polimerase , Saliva , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/microbiologia , Streptococcus pyogenes/genética
11.
SLAS Technol ; 27(6): 344-349, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35970321

RESUMO

Lumen structures exist throughout the human body, and the vessels of the circulatory system are essential for carrying nutrients and oxygen and regulating inflammation. Vasodilation, the widening of the blood vessel lumen, is important to the immune response as it increases blood flow to a site of inflammation, raises local temperature, and enables optimal immune system function. A common method for studying vasodilation uses excised vessels from animals; major drawbacks include heterogeneity in vessel shape and size, time-consuming procedures, sacrificing animals, and differences between animal and human biology. We have developed a simple, user-friendly in vitro method to form freestanding cell-laden hydrogel rings from collagen and quantitatively measure the effects of vasodilators on ring size. The hydrogel rings are composed of collagen I and can be laden with human vascular smooth muscle cells, a major cellular and structural component of blood vessels, or lined with endothelial cells in the lumen. The methods presented include a 3D printed device (which is amenable to future fabrication by injection molding) and commercially available components (e.g., Teflon tubing or a syringe) to form hydrogel rings between 2.6-4.6 mm outer diameter and 0.79-1.0 mm inner diameter. Here we demonstrate a significant difference in ring area in the presence of a known vasodilator, fasudil (p < 0.0001). Our method is easy to implement and provides a foundation for a medium-throughput solution to generating vessel model structures for future investigations of the fundamental mechanisms of vasodilation (e.g., studying uncharacterized endogenous molecules that may have vasoactivity) and testing vasoactive drugs.


Assuntos
Células Endoteliais , Hidrogéis , Animais , Humanos , Hidrogéis/química , Corpo Humano , Colágeno/química , Injeções
12.
Front Digit Health ; 4: 903153, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36033636

RESUMO

Expanding whole blood sample collection for transcriptome analysis beyond traditional phlebotomy clinics will open new frontiers for remote immune research and telemedicine. Determining the stability of RNA in blood samples exposed to high ambient temperatures (>30°C) is necessary for deploying home-sampling in settings with elevated temperatures (e.g., studying physiological response to natural disasters that occur in warm locations or in the summer). Recently, we have developed homeRNA, a technology that allows for self-blood sampling and RNA stabilization remotely. homeRNA consists of a lancet-based blood collection device, the Tasso-SST™ which collects up to 0.5 ml of blood from the upper arm, and a custom-built stabilization transfer tube containing RNAlater™. In this study, we investigated the robustness of our homeRNA kit in high temperature settings via two small pilot studies in Doha, Qatar (no. participants = 8), and the Western and South Central USA during the summer of 2021, which included a heatwave of unusually high temperatures in some locations (no. participants = 11). Samples collected from participants in Doha were subjected to rapid external temperature fluctuations from being moved to and from air-conditioned areas and extreme heat environments (up to 41°C external temperature during brief temperature spikes). In the USA pilot study, regions varied in outdoor temperature highs (between 25°C and 43.4°C). All samples that returned a RNA integrity number (RIN) value from the Doha, Qatar group had a RIN ≥7.0, a typical integrity threshold for downstream transcriptomics analysis. RIN values for the Western and South Central USA samples (n = 12 samples) ranged from 6.9-8.7 with 9 out of 12 samples reporting RINs ≥7.0. Overall, our pilot data suggest that homeRNA can be used in some regions that experience elevated temperatures, opening up new geographical frontiers in disseminated transcriptome analysis for applications critical to telemedicine, global health, and expanded clinical research. Further studies, including our ongoing work in Qatar, USA, and Thailand, will continue to test the robustness of homeRNA.

13.
PLoS One ; 16(9): e0255841, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34473717

RESUMO

BACKGROUND: Efforts to minimize COVID-19 exposure during the current SARS-CoV-2 pandemic have led to limitations in access to medical care and testing. The Tasso-SST kit includes all of the components necessary for remote, capillary blood self-collection. In this study, we sought to investigate the accuracy and reliability of the Tasso-SST device as a self-collection device for measurement of SARS-CoV-2 IgG antibodies. METHODS: Capillary blood was obtained via unsupervised and supervised application of the Tasso-SST device, and venous blood was collected by standard venipuncture. Unsupervised self-collected blood samples underwent either extreme summer or winter-simulated shipping conditions prior to testing. Sera obtained by all three methods were tested concurrently using the EuroImmun anti-SARS-CoV-2 S1 IgG assay in a CLIA-certified clinical laboratory. RESULTS: Successful Tasso-SST capillary blood collection by unsupervised and supervised administration was completed by 93.4% and 94.5% of participants, respectively. Sera from 56 participants, 55 with documented (PCR+) COVID-19, and 33 healthy controls were then tested for anti-SARS-CoV-2 IgG antibodies. Compared to venous blood results, Tasso-SST-collected (unstressed) and the summer- and winter-stressed blood samples demonstrated Deming regression slopes of 1.00 (95% CI: 0.99-1.02), 1.00 (95% CI: 0.98-1.01), and 0.99 (95% CI: 0.97-1.01), respectively, with an overall accuracy of 98.9%. CONCLUSIONS: Capillary blood self-collection using the Tasso-SST device had a high success rate. Moreover, excellent concordance was found for anti-SARS-CoV-2 IgG results between Tasso-SST capillary and standard venous blood-derived sera. The Tasso-SST device should enable widespread collection of capillary blood for testing without medical supervision, facilitating epidemiologic studies.


Assuntos
Anticorpos Antivirais/imunologia , Coleta de Amostras Sanguíneas/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , Imunoglobulina G/imunologia , SARS-CoV-2/imunologia , Adulto , Idoso , Coleta de Amostras Sanguíneas/instrumentação , COVID-19/epidemiologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Reprodutibilidade dos Testes , SARS-CoV-2/fisiologia , Sensibilidade e Especificidade , Adulto Jovem
14.
Anal Chem ; 93(39): 13196-13203, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34546711

RESUMO

Gene expression analysis (e.g., targeted gene panels and transcriptomics) from whole blood can elucidate mechanisms of the immune function and aid in the discovery of biomarkers. Conventional venipuncture offers only a small snapshot of our broad immune landscape as immune responses may occur outside of the time and location parameters available for conventional venipuncture. A self-operated method that enables flexible sampling of liquid whole blood coupled with immediate stabilization of cellular RNA is instrumental in facilitating capture and preservation of acute or transient immune fluxes. To this end, we developed homeRNA, a kit for self-collection of peripheral blood (∼0.5 mL) and immediate stabilization of cellular RNA, using the Tasso-SST blood collection device with a specially designed stabilizer tube containing RNAlater. To assess the feasibility of homeRNA for self-collection and stabilization of whole blood RNA, we conducted a pilot study (n = 47 participants) in which we sent homeRNA to participants aged 21-69, located across 10 US states (94% successful blood collections, n = 61/65). Among participants who successfully collected blood, 93% reported no or minimal pain/discomfort using the kit (n = 39/42), and 79% reported very easy/somewhat easy stabilization protocol (n = 33/42). Total RNA yield from the stabilized samples ranged between 0.20 and 5.99 µg (mean = 1.51 µg), and all but one RNA integrity number values were above 7.0 (mean = 8.1), indicating limited RNA degradation. The results from this study demonstrate the self-collection and RNA stabilization of whole blood with homeRNA by participants themselves in their own home.


Assuntos
RNA , Humanos , Projetos Piloto
15.
Anal Chem ; 93(33): 11433-11441, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34379402

RESUMO

Aerosols dispersed and transmitted through the air (e.g., particulate matter pollution and bioaerosols) are ubiquitous and one of the leading causes of adverse health effects and disease transmission. A variety of sampling methods (e.g., filters, cyclones, and impactors) have been developed to assess personal exposures. However, a gap still remains in the accessibility and ease-of-use of these technologies for people without experience or training in collecting airborne samples. Additionally, wet scrubbers (large non-portable industrial systems) utilize liquid sprays to remove aerosols from the air; the goal is to "scrub" (i.e., clean) the exhaust of industrial smokestacks, not collect the aerosols for analysis. Inspired by wet scrubbers, we developed a device fundamentally different from existing portable air samplers by using aerosolized microdroplets to capture aerosols in personal spaces (e.g., homes, offices, and schools). Our aerosol-sampling device is the size of a small teapot, can be operated without specialized training, and features a winding flow path in a supersaturated relative humidity environment, enabling droplet growth. The integrated open mesofluidic channels shuttle coalesced droplets to a collection chamber for subsequent sample analysis. Here, we present the experimental demonstration of aerosol capture in water droplets. An iterative study optimized the non-linear flow manipulating baffles and enabled an 83% retention of the aerosolized microdroplets in the confined volume of our device. As a proof-of-concept for aerosol capture into a liquid medium, 0.5-3 µm model particles were used to evaluate aerosol capture efficiency. Finally, we demonstrate that the device can capture and keep a bioaerosol (bacteriophage MS2) viable for downstream analysis.


Assuntos
Levivirus , Material Particulado , Aerossóis/análise , Microbiologia do Ar , Monitoramento Ambiental , Humanos , Tamanho da Partícula
16.
Nat Commun ; 11(1): 5158, 2020 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-33056992

RESUMO

Filamentous fungi differentiate along complex developmental programs directed by abiotic and biotic signals. Currently, intrinsic signals that govern fungal development remain largely unknown. Here we show that an endogenously produced and secreted fungal oxylipin, 5,8-diHODE, induces fungal cellular differentiation, including lateral branching in pathogenic Aspergillus fumigatus and Aspergillus flavus, and appressorium formation in the rice blast pathogen Magnaporthe grisea. The Aspergillus branching response is specific to a subset of oxylipins and is signaled through G-protein coupled receptors. RNA-Seq profiling shows differential expression of many transcription factors in response to 5,8-diHODE. Screening of null mutants of 33 of those transcription factors identifies three transcriptional regulators that appear to mediate the Aspergillus branching response; one of the mutants is locked in a hypo-branching phenotype, while the other two mutants display a hyper-branching phenotype. Our work reveals an endogenous signal that triggers crucial developmental processes in filamentous fungi, and opens new avenues for research on the morphogenesis of filamentous fungi.


Assuntos
Proteínas Fúngicas/metabolismo , Regulação da Expressão Gênica no Desenvolvimento , Regulação Fúngica da Expressão Gênica , Ácidos Linoleicos/metabolismo , Oxilipinas/metabolismo , Aspergillus flavus/genética , Aspergillus flavus/crescimento & desenvolvimento , Aspergillus flavus/metabolismo , Aspergillus fumigatus/genética , Aspergillus fumigatus/crescimento & desenvolvimento , Aspergillus fumigatus/metabolismo , Proteínas Fúngicas/genética , Hifas/crescimento & desenvolvimento , Hifas/metabolismo , Magnaporthe/genética , Magnaporthe/crescimento & desenvolvimento , Magnaporthe/metabolismo , Mutação , RNA-Seq , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Transdução de Sinais/genética , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
17.
Langmuir ; 36(43): 12795-12803, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-32936651

RESUMO

Velocity of capillary flow in closed or open channels decreases as the flow proceeds down the length of the channel, varying as the inverse of the square root of time or as the inverse of travel distance. In order to increase the flow rate-and extend the duration of the flow-capillary pumps have been designed by mimicking the pumping principle of paper or cotton fibers. These designs provide a larger volume available for the wicking of the liquids. In microsystems for biotechnology, different designs have been developed based on experimental observation. In the present paper, the mechanisms at the basis of capillary pumping are investigated using a theoretical model for the flow in an open-channel "capillary tree" (i.e., an ensemble of channels with bifurcations mimicking the shape of a tree). The model is checked against experiments. Rules for obtaining better designs of capillary pumps are proposed; specifically, we find (1) when using a capillary tree with identical channel cross-sectional areas throughout, it is possible to maintain nearly constant flow rates throughout the channel network, (2) flow rate can be increased at each branch point of a capillary tree by slightly decreasing the areas of the channel cross section and decreasing the channel lengths at each level of ramification within the tree, and (3) higher order branching (trifurcations vs bifurcations) amplify the flow rate effect. This work lays the foundation for increasing the flow rate in open microfluidic channels driven by capillary flow; we expect this to have broad impact across open microfluidics for biological and chemical applications such as cell culture, sample preparation, separations, and on-chip reactions.


Assuntos
Microfluídica , Árvores , Capilares , Ação Capilar , Modelos Teóricos
18.
Anal Chem ; 92(20): 13634-13640, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-32941013

RESUMO

Intercellular communication through the secretion of soluble factors plays a vital role in a wide range of biological processes (e.g., homeostasis, immune response), yet identification and quantification of many of these factors can be challenging due to their degradation or sequestration in cell culture media prior to analysis. Here, we present a customizable bead-based system capable of simultaneously binding to live cells (through antibody-mediated cell tethering) and capturing cell-secreted molecules. Our functionalized beads capture secreted molecules (e.g., hepatocyte growth factor secreted by fibroblasts) that are diminished when sampled via traditional supernatant analysis techniques (p < 0.05), effectively rescuing a reduced signal in the presence of neutralizing components in the cell culture media. Our system enables capture and analysis of molecules integral to chemical communication that would otherwise be markedly decreased prior to analysis.


Assuntos
Antígenos de Superfície/metabolismo , Fator de Crescimento de Hepatócito/análise , Microesferas , Anticorpos/imunologia , Antígenos de Superfície/análise , Antígenos de Superfície/imunologia , Linhagem Celular , Meios de Cultura/química , Fibroblastos/citologia , Fibroblastos/metabolismo , Fluoresceínas/química , Fator de Crescimento de Hepatócito/imunologia , Fator de Crescimento de Hepatócito/metabolismo , Células Endoteliais da Veia Umbilical Humana , Humanos , Imunoensaio/métodos , Antígenos Thy-1/análise , Antígenos Thy-1/imunologia , Antígenos Thy-1/metabolismo
19.
Bioanalysis ; 12(13): 893-904, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32648772

RESUMO

In this paper we show the application of the Tasso OnDemand™, a novel automated sample collection device, in conjunction with volumetric absorptive microsampling (VAMS) for the development of gefapixant, a P2X3 receptor antagonist currently under clinical development for the treatment of refractory and unexplained chronic cough and endometriosis-related pain. A LC-MS/MS bioanalytical method was developed and validated using VAMS to support this development program. This method was utilized in a drug-drug interaction study to establish a mathematical bridging relationship with data obtained from a validated plasma assay used to support the program. The VAMS bioanalytical method and the predictability of the mathematical relationship is reported and discussed here.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Microtecnologia/instrumentação , Pirimidinas/sangue , Sulfonamidas/sangue , Humanos , Limite de Detecção
20.
Am J Physiol Renal Physiol ; 319(1): F41-F51, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32390509

RESUMO

Endothelial cells (ECs) from different human organs possess organ-specific characteristics that support specific tissue regeneration and organ development. EC specificity is identified by both intrinsic and extrinsic cues, among which the parenchyma and organ-specific microenvironment are critical contributors. These extrinsic cues are, however, largely lost during ex vivo cultures. Outstanding challenges remain to understand and reestablish EC organ specificity for in vitro studies to recapitulate human organ-specific physiology. Here, we designed an open microfluidic platform to study the role of human kidney tubular epithelial cells in supporting EC specificity. The platform consists of two independent cell culture regions segregated with a half wall; culture media are added to connect the two culture regions at a desired time point, and signaling molecules can travel across the half wall (paracrine signaling). Specifically, we report that in the microscale coculture device, primary human kidney proximal tubule epithelial cells (HPTECs) rescued primary human kidney peritubular microvascular EC (HKMEC) monolayer integrity and fenestra formation and that HPTECs upregulated key HKMEC kidney-specific genes (hepatocyte nuclear factor 1 homeobox B, adherens junctions-associated protein 1, and potassium voltage-gated channel subfamily J member 16) and endothelial activation genes (vascular cell adhesion molecule-1, matrix metalloproteinase-7, and matrix metalloproteinase-10) in coculture. Coculturing with HPTECs also promoted kidney-specific genotype expression in human umbilical vein ECs and human pluripotent stem cell-derived ECs. Compared with culture in HPTEC conditioned media, coculture of ECs with HPTECs showed increased upregulation of kidney-specific genes, suggesting potential bidirectional paracrine signaling. Importantly, our device is compatible with standard pipettes, incubators, and imaging readouts and could also be easily adapted to study cell signaling between other rare or sensitive cells.


Assuntos
Células Endoteliais/metabolismo , Células Epiteliais/metabolismo , Rim/metabolismo , Comunicação Parácrina/fisiologia , Células Cultivadas , Técnicas de Cocultura , Células Endoteliais/citologia , Células Epiteliais/citologia , Humanos , Rim/citologia , Microfluídica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA