Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Talanta ; 278: 126513, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970965

RESUMO

In this work, the electrochemical behavior of the glycosylated flavonoid kaempferitrin was studied, and an electroanalytical methodology was developed for its determination in infusions of Bauhinia forficata using a boron-doped diamond electrode (BDD). The electrochemical behavior of the flavonoid was studied by cyclic voltammetry, and two irreversible oxidation peaks at 0.80 and 1.0 V vs Ag/AgCl were observed. The influence of the pH on the voltammograms was examined, and higher sensitivity was found at pH 7.0. The electrochemical process corresponding to peak 1 at 0.80 V is predominantly diffusion-controlled, as the study shows at varying scan rates. An analytical plot was obtained by square wave voltammetry at optimized experimental conditions (frequency = 100 s-1, amplitude = 90 mV, and step potential = 8 mV) in the concentration range from 3.4 µmol L-1 to 58 µmol L-1, with a linearity of 0.99. The limit of detection and limit of quantification values were 1.0 µmol L-1 and 3.4 µmol L-1, respectively. Three samples of Bauhinia forficata infusions (2 g of sample in 100 mL of water) were analyzed, and the KF values found were 5.0 × 10-4 mol L-1, 3.0 × 10-4 mol L-1, and 7.0 × 10-4 mol L-1, with recovery percentages of 98 %, 106 % and 94 %, respectively. Finally, experiments were performed with two other flavonoids (chrysin and apeginin) to compare and propose an electrochemical oxidation mechanism for kaempferitrin, which was supported by quantum chemical calculations.

2.
Anal Methods ; 16(26): 4415-4420, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38904354

RESUMO

A nanoporous gold microelectrode (NPG-µE) was fabricated and used for Pb(II) detection in seawater samples via square wave anodic stripping voltammetry (SWASV). The Au microelectrode (Au-µE) was fabricated by embedding a gold microfiber into a Pasteur pipette, and its surface was further modified by an anodization-electrochemical reduction (A-ECR) method, yielding the NPG-µE. The fabricated electrodes were characterized by cyclic voltammetry (CV) and field emission scanning electron microscopy (FE-SEM) for electrochemical and structural morphological investigations. SWASV results show a Pb(II) stripping peak at around -0.05 V vs. Ag/AgCl, sat. KCl, which is unusual for common Pb(II) detection (typically occurring at around -0.40 V) in anodic stripping voltammetry (ASV) analysis. The Pb(II) detection at less negative stripping potential is more beneficial. Hence, it exhibited anti-interference properties with Cd(II), which is attributed to the preferential deposition and stripping of the target analyte on the low-indexed crystal planes of the NPG structure. The calibration plot obtained by SWASV was linear in the concentration range of 0.1-10 µM, and the detection limit was found to be 57 nM (correlation coefficient of 0.9974). The NPG microsensor presented a 15-fold enhanced current response compared to Au-µE, with excellent sensitivity (27.2 µA µM-1 cm-2). The application of the NPG microsensor was examined by detecting Pb(II) in seawater samples, and a satisfactory performance was obtained.

3.
J Microsc ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874394

RESUMO

Nanoporous gold electrodes are of great interest in electroanalytical chemistry, because of their unusual activity and large surface area. The electrochemical activity can be further improved by coating with molecular catalysts such as the tetraruthenated cobalt-tetrapyridylporphyrazines investigated in this work. The plasmonic enhancement of the scattered light at the nanoholes and borders modifies the electrode's optical characteristics, improving the transmission through the surface-enhanced Raman scattering (SERS) effect. When monitored by hyperspectral dark-field and confocal Raman microscopy, this effect allows probing of the porphyrazine species at the plasmonic nanholes, improving the understanding of the chemically modified gold electrodes.

4.
Talanta ; 273: 125971, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38521020

RESUMO

T-2 is one of the most potent cytotoxic food-borne mycotoxins. In this work, we have developed and characterized an electrochemical microfluidic immunosensor for T-2 toxin quantification in wheat germ samples. T-2 toxin detection was carried out using a competitive immunoassay method based on monoclonal anti-T-2 antibodies immobilized on the poly(methyl methacrylate) (PMMA) microfluidic central channel. The platinum wire working electrode at the end of the channel was in situ modified by a single-step electrodeposition procedure with reduced graphene oxide (rGO)-nanoporous gold (NPG). T-2 toxin in the sample was allowed to compete with T-2-horseradish peroxidase (HRP) conjugated for the specific recognizing sites of immobilized anti-T-2 monoclonal antibodies. The HRP, in the presence of hydrogen peroxide (H2O2), catalyzes the oxidation of 4-tert-butylcatechol (4-TBC), whose back electrochemical reduction was detected on the nanostructured electrode at -0.15 V. Thus, at low T-2 concentrations in the sample, more enzymatically conjugated T-2 will bind to the capture antibodies, and, therefore, a higher current is expected. The detection limits found for electrochemical immunosensor, and commercial ELISA procedure were 0.10 µg kg-1 and 10 µg kg-1, and the intra- and inter-assay coefficients of variation were below 5.35% and 6.87%, respectively. Finally, our microfluidic immunosensor to T-2 toxin will significantly contribute to faster, direct, and secure in situ analysis in agricultural samples.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Micotoxinas , Nanoporos , Toxina T-2 , Grafite/química , Imunoensaio/métodos , Microfluídica , Ouro/química , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/química , Técnicas Eletroquímicas/métodos , Limite de Detecção , Nanopartículas Metálicas/química
5.
Anal Chem ; 95(28): 10634-10643, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37347237

RESUMO

A simple fabrication method to make electrochemical sensors is reported. The electrodes were fabricated with a commercial filament based on polylactic acid and carbon black (PLA/CB). They were engineered with a three-dimensional (3D) printing pen and poly(methyl methacrylate) template. The optimization parameters included the thickness and diameters of the electrodes. The electrode diameter was restricted by the 3D printing pen's nozzle dimension, and larger diameters generated small cracks on the electrode surface, compromising their analytical signal. The electrode thickness can increase the electrical resistance, affecting their electrochemical response. The fabrication showed reproducibility (RSD = 4%). The electrode surface was easily renewed by sanding the electrodes, making them reusable. Additionally, the proposed sensor provided comparable electrochemical responses over traditional glassy carbon electrodes. Moreover, no (electro)chemical surface treatment was required for sensing applications due to the compromise between the thickness and diameters of the electrodes, effectively translating the filaments' electrical properties to resulting materials. The electrodes' analytical performance was shown for organic and inorganic species, including paraquat, Pb2+, and caffeic acid. As proof of concept, the analytical applicability was demonstrated for total polyphenolic quantification in tea samples. Therefore, this work provides an alternative to fabricating miniaturized electrodes, bringing valuable insights into PLA/CB 3D-printed sensors and opening possibilities for designing electrode arrays. Moreover, the proposed electrodes are promising platforms for paper-based microfluidic systems.

6.
Polymers (Basel) ; 15(7)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37050372

RESUMO

Caffeine (CAF) is a psychostimulant present in many beverages and with rapid bioabsorption. For this reason, matrices that effectuate the sustained release of a low amount of CAF would help reduce the intake frequency and side effects caused by high doses of this stimulant. Thus, in this study, CAF was loaded into magnetic gelatin/alginate (Gel/Alg/MNP) hydrogels at 18.5 mg/ghydrogel. The in vitro release of CAF was evaluated in the absence and presence of an external magnetic field (EMF) and Ca2+. In all cases, the presence of Ca2+ (0.002 M) retarded the release of CAF due to favorable interactions between them. Remarkably, the release of CAF from Gel/Alg/MNP in PBS/CaCl2 (0.002 M) at 37 °C under an EMF was more sustained due to synergic effects. In PBS/CaCl2 (0.002 M) and at 37 °C, the amounts of CAF released after 45 min from Gel/Alg and Gel/Alg/MNP/EMF were 8.3 ± 0.2 mg/ghydrogel and 6.1 ± 0.8 mg/ghydrogel, respectively. The concentration of CAF released from Gel/Alg and Gel/Alg/MNP hydrogels amounted to ~0.35 mM, thereby promoting an increase in cell viability for 48 h. Gel/Alg and Gel/Alg/MNP hydrogels can be applied as reservoirs to release CAF at suitable concentrations, thus forestalling possible side effects and improving the viability of SH-SY5Y cells.

7.
Molecules ; 28(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36615580

RESUMO

Nitrite is a ubiquitous pollutant in modern society. Developing new strategies for its determination is very important, and electroanalytical methods present outstanding performance on this task. However, the use of bare electrodes is not recommended because of their predisposition to poisoning and passivation. We herein report a procedure to overcome these limitations on carbon fiber microelectrodes through pulsed amperometry. A three-pulse amperometry approach was used to reduce the current decay from 47% (after 20 min under constant potential) to virtually 0%. Repeatability and reproducibility were found to have an RSD lower than 0.5% and 7%, respectively. Tap water and synthetic inorganic saliva samples were fortified with nitrite, and the results obtained with the proposed sensor were in good agreement with the amount added.


Assuntos
Incrustação Biológica , Nitritos , Microeletrodos , Fibra de Carbono , Nitritos/análise , Reprodutibilidade dos Testes , Incrustação Biológica/prevenção & controle , Eletrodos , Carbono , Técnicas Eletroquímicas/métodos
8.
Biosens Bioelectron ; 199: 113874, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34920228

RESUMO

Highly sensitive and selective nanostructured lactate and glucose microbiosensors for their in vivo simultaneous determination in rat brain were developed based on carbon fiber microelectrodes (CFM) modified with nanoporous gold (NPG) using the Dynamic Hydrogen Bubble Template (DHBT) method. Electrodeposition of platinum nanoparticles (PtNP) onto the NPG film enhances the sensitivity and the electrocatalytic properties towards H2O2 detection. The nanostructured microelectrode platform was modified by glucose oxidase (GOx) and lactate oxidase (LOx) enzyme immobilization. High selective measurements were achieved by covering with a perm-selective layer of electropolymerized m-phenylenediamine, deposition of a Nafion® film and by using a null sensor. The morphological characteristics and electroanalytical performance of the microbiosensors were assessed, by scanning electron microscopy and electrochemical techniques, respectively. The PtNP/NPG/CFM shows a high sensitivity to H2O2 (5.96 A M-1 cm-2) at 0.36 V vs. Ag/AgCl, with a linear range from 0.2 to 200 µM, and an LOD of 10 nM. The microbiosensors were applied to the simultaneous determination of lactate and glucose in blood serum samples. Moreover, the basal extracellular concentrations of lactate and glucose were measured in vivo in four different rat brain structures. These results support the potential of the microbiosensor to be used as a valuable tool to investigate brain neurochemicals in vivo.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanoporos , Animais , Encéfalo/metabolismo , Técnicas Eletroquímicas , Enzimas Imobilizadas/metabolismo , Glucose , Glucose Oxidase/metabolismo , Peróxido de Hidrogênio , Lactatos , Platina , Ratos , Soro
9.
Talanta ; 226: 122130, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33676684

RESUMO

In this work, nanoporous gold (NPG) was prepared according to three different approaches, such as (i) anodization-electrochemical reduction (A-ECR, NPGA), (ii) dynamic hydrogen bubble template (DHBT, NPGB), and (iii) the combination of both methods (NPGA+B). Field-emission scanning electron microscopy (FE-SEM) and cyclic voltammetry (CV) were used to investigate the structural morphology and the electrochemical behavior of the fabricated materials. The NPGA+B electrode showed a large amount of surface defects and/or edges, greater electrochemical surface area (2.5 cm2), and increased roughness factor (35.4). Such outstanding features of the NPGA+B platform were demonstrated by the sensitive detection of methyl parathion (MP) in river water samples. CV results indicated nearly 25-fold, 6-fold, and 2.5-fold higher sensitivity for NPGA+B compared to that of bare Au, NPGA, and NPGB, respectively. Differential pulse voltammetry (DPV) results show a linear behavior in the MP concentration range of 5-50 ng mL-1 with a limit of detection (LOD) of 0.6 ng mL-1 and limit of quantification (LOQ) of 2.0 ng mL-1. Besides, the NPGA+B sensor also revealed excellent selectivity towards MP detection in the presence of other interfering molecules or ions, reproducibility, and repeatability.

10.
Anal Chim Acta ; 1146: 88-97, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33461723

RESUMO

Metabolic analysis in animals is usually either evaluated as whole-body measurements or in isolated tissue samples. To reveal tissue specificities in vivo, this study uses scanning electrochemical microscopy (SECM) to provide localized oxygen consumption rates (OCRs) in different regions of single adult Caenorhabditis elegans individuals. This is achieved by measuring the oxygen reduction current at the SECM tip electrode and using a finite element method model of the experiment that defines oxygen concentration and flux at the surface of the organism. SECM mapping measurements uncover a marked heterogeneity of OCR along the worm, with high respiration rates at the reproductive system region. To enable sensitive and quantitative measurements, a self-referencing approach is adopted, whereby the oxygen reduction current at the SECM tip is measured at a selected point on the worm and in bulk solution (calibration). Using genetic and pharmacological approaches, our SECM measurements indicate that viable eggs in the reproductive system are the main contributors in the total oxygen consumption of adult Caenorhabditis elegans. The finding that large regional differences in OCR exist within the animal provides a new understanding of oxygen consumption and metabolic measurements, paving the way for tissue-specific metabolic analyses and toxicity evaluation within single organisms.


Assuntos
Caenorhabditis elegans , Consumo de Oxigênio , Animais , Eletrodos , Genitália , Microscopia Eletroquímica de Varredura
11.
Anal Chem ; 93(2): 1143-1153, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33301317

RESUMO

This study is focused on identifying novel epithelial markers in circulating extracellular vesicles (EVs) through the development of a dual sandwich-type electrochemical paper-based immunosensor for Claudin 7 and CD81 determination, as well as its validation in breast cancer (BC) patients. This immunosensor allows for rapid, sensitive, and label-free detection of these two relevant BC biomarkers. Under optimum conditions, the limit of detection for Claudin 7 was 0.4 pg mL-1, with a wide linear range of 2 to 1000 pg mL-1, while for CD81, the limit of detection was 3 pg mL-1, with a wide linear range of 0.01 to 10 ng mL-1. Finally, we validated Claudin 7 and CD81 determination in EVs from 60 BC patients and 20 healthy volunteers, reporting higher diagnostic accuracy than the one observed with classical diagnostic markers. This analysis provides a low-cost, specific, versatile, and user-friendly strategy as a robust and reliable tool for early BC diagnosis.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Claudinas/análise , Vesículas Extracelulares/química , Papel , Tetraspanina 28/análise , Técnicas Biossensoriais , Técnicas Eletroquímicas , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos
12.
Anal Chim Acta ; 1127: 122-130, 2020 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-32800115

RESUMO

An ultrasensitive and portable microfluidic electrochemical immunosensor for SOX-2 cancer biomarker determination was developed. The selectivity and sensitivity of the sensor were improved by modifying the microfluidic channel. This was accomplished through a physical-chemical treatment to produce a hydrophilic surface, with an increased surface to volume/ratio, where the anti-SOX-2 antibodies can be covalently immobilized. A sputtered gold electrode was used as detector and its surface was activated by using a dynamic hydrogen bubble template method. As a result, a gold nanoporous structure (NPAu) with outstanding properties, like high specific surface area, large pore volume, uniform nanostructure, good conductivity, and excellent electrochemical activity was obtained. SOX-2 present in the sample was bound to the anti-SOX-2 immobilized in the microfluidic channel, and then was labeled with a second antibody marked with horseradish peroxidase (HRP-anti-SOX-2) like a sandwich immunoassay. Finally, an H2O2 + catechol solution was added, and the enzymatic product (quinone) was reduced on the NPAu electrode at +0.1 V (vs. Ag). The current obtained was directly proportional to the SOX-2 concentration in the sample. The detection limit achieved was 30 pg mL-1, and the coefficient of variation was less than 4.75%. Therefore, the microfluidic electrochemical immunosensor is a suitable clinical device for in situ SOX-2 determination in real samples.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanoporos , Anticorpos Imobilizados , Técnicas Eletroquímicas , Ouro , Peróxido de Hidrogênio , Imunoensaio , Limite de Detecção , Microfluídica
13.
RSC Adv ; 11(1): 408-415, 2020 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-35423017

RESUMO

In the present work, we describe a novel one-step enzyme-free dual electrochemical immunosensor for the determination of histidine-rich protein 2 (Ag-PfHRP2), a specific malaria biomarker. A gold electrode (GE) was functionalized with the PfHRP2 antibody (Ab-PfHRP2) using dihexadecyl phosphate (DHP) polymer as an immobilization platform. The Ab-PfHRP2/DHP/GE sensor was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, Fourier-transform infrared spectroscopy, scanning electron microscopy, and atomic force microscopy. The developed immunosensor was employed for indirect Ag-PfHRP2 determination by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The linear range was 10-400 ng mL-1 and 10-500 ng mL-1 for EIS and DPV, while the limit of detection was 3.3 ng mL-1 and 2.8 ng mL-1, respectively. The electrochemical immunosensor was successfully applied for Ag-PfHRP2 determination in human serum samples. Its performance was compared with an ELISA test, and good correspondence was achieved. The coefficients of intra- and inter-assay variations were less than 5%. The electrochemical immunosensor is a useful and straightforward tool for in situ malaria biomarker determination.

14.
Anal Chim Acta ; 1095: 61-70, 2020 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-31864631

RESUMO

Tuning the electrocatalytic properties of high surface area porous metallic frameworks like Nanoporous Gold (NPG) by tailoring the structure is a convenient strategy to design electrochemical sensors. Accordingly, an NPG-based sensitive, selective and robust electroanalytical platform was designed for the detection of ascorbic acid (AA) in acidic extracts of Aspergillus fumigatus fungus and Arabidopsis thaliana leaves. NPG films were electrodeposited on a gold microelectrode by potentiostatic electrodeposition and characterized by electron microscopy techniques, which confirmed the morphology and highly porous structure resembling nanowires-type pure gold fractals. The electrodeposition parameters, particularly deposition potential and time, were optimized to achieve large and selective amperometric detection of AA on the NPG modified electrodes. Faster electron transfer kinetics was manifested on the 0.3 V shift in overpotential and remarkable enhancement of the oxidation peak current as compared with bare gold electrode. Amperometric measurements were performed at 0.3 V vs. Ag/AgCl(sat. KCl) in the highly acidic electrolyte solution employed to extract ascorbate from biological samples and minimize its autoxidation. The sensitivity of conventional Au-microelectrodes was increased about one thousand-fold upon modification with NPG film, reaching 2 nA µmol-1 L-1. The detection limit for AA based on a linear current-concentration calibration plot was found to be 2 µmol L-1. The NPG-based microsensor was demonstrated to be selective, reproducible and stable, and was employed for determinations of AA concentration in highly acidic biological extracts.


Assuntos
Ácido Ascórbico/análise , Técnicas Eletroquímicas/métodos , Ouro/química , Nanofios/química , Arabidopsis/química , Ácido Ascórbico/química , Aspergillus fumigatus/química , Técnicas Eletroquímicas/instrumentação , Concentração de Íons de Hidrogênio , Limite de Detecção , Microeletrodos , Nanoporos , Oxirredução , Extratos Vegetais/análise , Folhas de Planta/química , Porosidade , Reprodutibilidade dos Testes
15.
Anal Chim Acta ; 1096: 120-129, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31883578

RESUMO

We report a microfluidic immunosensor for the electrochemical determination of IgG antibodies anti-Toxocara canis (IgG anti-T. canis). In order to improve the selectivity and sensitivity of the sensor, core-shell gold-ferric oxide nanoparticles (AuNPs@Fe3O4), and ordered mesoporous carbon (CMK-8) in chitosan (CH) were used. IgG anti-T. canis antibodies detection was carried out using a non-competitive immunoassay, in which excretory secretory antigens from T. canis second-stage larvae (TES) were covalently immobilized on AuNPs@Fe3O4. CMK-8-CH and AuNPs@Fe3O4 were characterized by transmission electron microscopy, scanning electron microscopy, energy dispersive spectrometry, cyclic voltammetry, electrochemical impedance spectroscopy, and N2 adsorption-desorption isotherms. Antibodies present in serum samples immunologically reacted with TES, and then were quantified by using a second antibody labeled with horseradish peroxidase (HRP-anti-IgG). HRP catalyzes the reduction from H2O2 to H2O with the subsequent oxidation of catechol (H2Q) to p-benzoquinone (Q). The enzymatic product was detected electrochemically at _100 mV on a modified sputtered gold electrode. The detection limit was 0.10 ng mL-1, and the coefficients of intra- and inter-assay variation were less than 6%, with a total assay time of 20 min. As can be seen, the electrochemical immunosensor is a useful tool for in situ IgG antibodies anti-T. canis determination.


Assuntos
Anticorpos Anti-Helmínticos/imunologia , Ouro/química , Nanopartículas Metálicas/química , Técnicas Analíticas Microfluídicas/instrumentação , Toxocara canis/imunologia , Toxocaríase/imunologia , Animais , Anticorpos Anti-Helmínticos/sangue , Técnicas Biossensoriais/instrumentação , Carbono/química , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Óxido Ferroso-Férrico/química , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Porosidade , Toxocaríase/sangue
16.
Anal Chim Acta ; 1087: 36-43, 2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31585564

RESUMO

The Scanning Bipolar Electrochemical Microscope (SBECM) allows precise positioning of an electrochemical micro-probe serving as bipolar electrode that can be wirelessly interrogated by coupling the electrochemical detection reaction with an electrochemiluminescent reporting process. As a result, the spatially heterogeneous concentrations of an analyte of interest can be converted in real time into a map of sample reactivity. However, this can only be achieved upon optimization of the analytical performance ensuring adequate sensitivity. Here, we present the evaluation and optimized operation of the SBECM for the detection of small changes in local O2 concentrations. Parameters for achieving an improved sensitivity as well as possibilities for improving the signal-to-noise ratio in the optical signal readout are evaluated. The capability of the SBECM for O2 detection is shown at controlled conditions by recording the topography of a patterned sample and monitoring O2 evolution from a photoelectrocatalyst material.

17.
Artigo em Inglês | MEDLINE | ID: mdl-31401310

RESUMO

To disclose the molecular mechanisms involved in luminal midgut buffering of M. domestica, we used RNA-seq analyses from triplicate samples of seven sections along the midgut to evaluate the expression levels of genes coding for selected manually curated protein sequences. Channels, pumps and transporters were confirmed as being apical by proteomics of purified microvillar membranes. Midgut pH determinations with a microsensor and a pH indicator were carried out in larvae in different diets with or without added compounds to evaluate the role of proteins in buffering. The data suggested that acidification occurs at middle midgut by the action of H+ V-ATPase with protons produced by carbonic anhydrase, followed by chloride ions transported by a K+Cl- symporter. K+ ions are recovered by an apical K+ channel and K+ homeostasis maintained by a basolateral Na+/K+-ATPase. Acidification is also affected by a Na+/H+ exchanger and a multidrug resistance protein. Posterior midgut alkalization results from the action of a NH3 transporter and H+-coupled peptide transporter, mainly in a diet rich in free peptides. A working model was proposed for the midgut luminal acidification and alkalization, as well as for mucosal protection against acid by a neutralized mucus layer.


Assuntos
Transporte Biológico/genética , Moscas Domésticas/genética , Proteínas de Insetos/genética , Larva/genética , Ácidos/química , Ácidos/farmacologia , Álcalis/química , Álcalis/farmacologia , Animais , Sistema Digestório/metabolismo , Moscas Domésticas/metabolismo , Concentração de Íons de Hidrogênio , Larva/efeitos dos fármacos , Larva/metabolismo , Proteômica , RNA-Seq , ATPase Trocadora de Sódio-Potássio/genética
18.
Mikrochim Acta ; 185(8): 367, 2018 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-29987397

RESUMO

Nanoporous gold (NPG) structures were prepared on the surface of a gold microelectrode (Au-µE) by an anodization-reduction method. Cyclic voltammetry and field emission scanning electron microscopy were used to study the electrochemical properties and the morphology of the nanostructured film. Voltammetry showed an improved sensitivity for dopamine (DA) oxidation at this microelectrode when compared to a bare gold microelectrode, with a peak near 0.2 V (vs. Ag/AgCl) at a scan rate of 0.1 V s-1. This is due to the increased surface area and roughness. Square wave voltammetry shows a response that is linear in the 0.1-10 µmol L-1 DA concentration range, with a 30 nmol L-1 detection limit and a sensitivity of 1.18 mA (µmol L-1)-1 cm-2. The sensor is not interfered by ascorbic acid. The reproducibility, repeatability, long-term stability and real sample analysis (spiked urine) were assessed, and acceptable performance was achieved. The "proof-of-concept" detection of dopamine release was demonstrated by using scanning electrochemical microscopy (SECM) with the aim of future applications for single cell analysis. Graphical abstract A reproducible electrochemical approach was proposed to fabricate an NPG-microelectrode for DA detection, with enhanced sensitivity and selectivity. Besides, a proof-of-concept detection of DA release was also demonstrated by using SECM.


Assuntos
Dopamina/análise , Eletroquímica/instrumentação , Ouro/química , Microscopia Eletroquímica de Varredura , Nanoporos , Dopamina/urina , Limite de Detecção , Microeletrodos
19.
Anal Chem ; 90(10): 6267-6274, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29682961

RESUMO

Electrochemical techniques offer high temporal resolution for studying the dynamics of electroactive species at samples of interest. To monitor fastest concentration changes, a micro- or nanoelectrode is accurately positioned in the vicinity of a sample surface. Using a microelectrode array, it is even possible to investigate several sites simultaneously and to obtain an instantaneous image of local dynamics. However, the spatial resolution is limited by the minimal electrode size required in order to contact the electrodes. To provide a remedy, we introduce the concept of scanning bipolar electrochemical microscopy and the corresponding experimental system. This technique allows precise positioning of a wireless scanning bipolar electrode to convert spatially heterogeneous concentrations of the analyte of interest into an electrochemiluminescence map of the sample reactivity. After elucidating the working principle by recording bipolar line and array scans, a bipolar electrode array is positioned at the site of interest to record an electrochemical image of the localized release of analyte molecules.

20.
Anal Chem ; 90(4): 2587-2593, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29345916

RESUMO

Peroxiredoxins (Prx) are important proteins involved in hydroperoxide degradation and are related to virulence in several pathogens, including Aspergillus fumigatus. In this work, in vivo studies on the degradation of hydrogen peroxide (H2O2) in the microenvironment of A. fumigatus fungus were performed by using an integrated Pt microelectrode. Three A. fumigatus strains were used to confirm the role of the cytosolic protein Prx1 in the defense mechanism of this microorganism: a wild-type strain, capable to expressing the protein Prx1; a Δprx strain, whose gene prx1 was removed; and a genetically complemented Δprx1::prx1+ strain generated from the Δprx1 and in which the gene prx1 was reintroduced. The fabricated microelectrode was shown to be a reliable inert probe tip for in situ and real-time measurements of H2O2 in such microenvironments, with potential applications in investigations involving the mechanism of oxidative stress.


Assuntos
Aspergillus fumigatus/química , Peróxido de Hidrogênio/análise , Peroxirredoxinas/metabolismo , Platina/química , Aspergillus fumigatus/citologia , Aspergillus fumigatus/enzimologia , Sobrevivência Celular , Técnicas Eletroquímicas , Peróxido de Hidrogênio/metabolismo , Microeletrodos , Estresse Oxidativo , Peroxirredoxinas/química , Peroxirredoxinas/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA