Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Brachytherapy ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39217003

RESUMO

PURPOSE: The purpose of this work was to evaluate whether inter-fraction imaging and replanning enhance treatment delivery adherence to clinical planning objectives in the context of a 5-fraction template-based interstitial brachytherapy (TISB) approach for gynecologic cancer treatment. METHODS AND MATERIALS: This retrospective study analyzed nineteen patients who underwent 5 fractions of interstitial brachytherapy over 3 days using the Syed-Neblett template. A verification CT scan was acquired for applicator assessment and reviewed by a radiation oncologist and medical physicist before each fraction. Eleven patients required replanning at least once during the treatment course. Replanning on the verification CT scan consisted of generating new target and organ-at-risk contours, digitizing catheter positions, and optimizing source dwell times to meet planning objectives. Dwell times and positions from the initial treatment plan were evaluated on the new contours to assess the dose that would have been delivered without replanning (nonadapted). Significance of nonadapted versus adapted dose differences were evaluated using a 2-sided Wilcoxon sum rank test. RESULTS: The average (min, max) change in dose (Gy) between the clinically delivered plans and the nonadapted plans were HR-CTV D90%: -6.5 (-0.6, -15.1), HR-CTV D98%: -6.5 (-0.4, -12.6), Bladder D2cc: -0.5 (0.0, -2.8), Bowel D2cc: -0.8 (0.0, -3.2), Rectum D2cc: -1.1 (0.0, -11.5), Sigmoid D2cc: -1.4 (-0.1, -5.4). Dosimetric changes in HR-CTV coverage were significantly improved with replanning while organ-at-risk differences were nonsignificant (p > 0.05). Fraction 3 was the most common fraction indicated for replanning. CONCLUSIONS: Replanning template-based interstitial brachytherapy can improve target coverage and adherence to planning goals.

2.
J Appl Clin Med Phys ; 24(10): e14130, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37646429

RESUMO

Concept inventories are multiple choice exams designed with the intention to test core concepts on specific subjects and evaluate common misconceptions. These tests serve as a useful tool in the classroom to assess value added by the instructor's educational methods and to better understand how students learn. They can provide educators with a method to evaluate their current teaching strategies and to make modifications that enhance student learning and ultimately elevate the quality of medical physics education. The use of concept inventories in introductory college physics courses revealed important gaps in conceptual understanding of physics by undergraduate students and motivated a shift of physics teaching towards more effective methods, such as active learning techniques. The goal of this review is to introduce medical physicists to concept inventories as educational evaluation tools and discuss potential applications to medical physics education by development through multi-institutional collaboration.

3.
Health Phys ; 114(4): 450-459, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29481536

RESUMO

There is a growing need to estimate the absorbed dose to small animals from preclinical investigations involving diagnostic and therapeutic radiopharmaceuticals. This paper introduces a Monte Carlo-based dosimetry platform called RAPID, which is capable of calculating murine-specific three-dimensional (3D) dose distributions. A comparison is performed between absorbed doses calculated with RAPID and absorbed doses calculated in a commonly used reference mouse phantom called MOBY. Four test mice containing different xenografts underwent serial PET/CT imaging using a novel diagnostic therapy (theranostic) agent NM404, which can be labeled with I for imaging or I for therapy. Using the PET/CT data, 3D dose distributions from I-NM404 were calculated in the mice using RAPID. Mean organ doses in these four test mice were compared to mean organ doses derived by using two previously published I S-values datasets in MOBY. In addition, mean tumor doses calculated in RAPID were compared to mean organ doses derived from unit density spheres. Large differences were identified between mean organ doses calculated in the test mice using RAPID and those derived in the MOBY phantom. Mean absorbed dose percent errors in organs ranged between 0.3% and 333%. Overall, mass scaling improved agreement between MOBY phantom calculations and RAPID, where percent errors were all less than 26%, with the exception of the lung in which percent errors reached values of 48%. Percent errors in mean tumor doses in the test mice and unit density spheres were less pronounced but still ranged between 8% and 23%. This work demonstrates the limitations of using pre-computed S-values in computational phantoms to predict organ doses in small animals from theranostic procedures. RAPID can generate accurate 3D dose distributions in small animals and in turn offer much greater insight on the ability of a given theranostic agent to image and treat diseases.


Assuntos
Avaliação Pré-Clínica de Medicamentos , Radioisótopos do Iodo/uso terapêutico , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Imagens de Fantasmas , Animais , Simulação por Computador , Humanos , Radioisótopos do Iodo/administração & dosagem , Masculino , Camundongos , Camundongos Endogâmicos NOD , Método de Monte Carlo , Neoplasias/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Doses de Radiação , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
4.
Med Dosim ; 38(1): 70-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22951538

RESUMO

To develop a device that allows supine craniospinal proton and photon therapy to the vast majority of proton and photon facilities currently experiencing limitations as a result of couch design issues. Plywood and carbon fiber were used for the development of a prototype unit. Once this was found to be satisfactory after all design issues were addressed, computer-assisted design (CAD) was used and carbon fiber tables were built to our specifications at a local manufacturer of military and racing car carbon fiber parts. Clinic-driven design was done using real-time team discussion for a prototype design. A local machinist was able to construct a prototype unit for us in <2 weeks after the start of our project. Once the prototype had been used successfully for several months and all development issues were addressed, a custom carbon fiber design was developed in coordination with a carbon fiber manufacturer in partnership. CAD methods were used to design the units to allow oblique fields from head to thigh on patients up to 200 cm in height. Two custom-designed carbon fiber craniospinal tabletop designs now exist: one long and one short. Four are in successful use in our facility. Their weight tolerance is greater than that of our robot table joint (164 kg). The long unit allows for working with taller patients and can be converted into a short unit as needed. An affordable, practical means of doing supine craniospinal therapy with protons or photons can be used in most locations via the use of these devices. This is important because proton therapy provides a much lower integral dose than all other therapy methods for these patients and the supine position is easier for patients to tolerate and for anesthesia delivery. These units have been successfully used for adult and pediatric supine craniospinal therapy, proton therapy using oblique beams to the low pelvis, treatment of various spine tumors, and breast-sparing Hodgkin's therapy.


Assuntos
Leitos , Radiação Cranioespinal/instrumentação , Posicionamento do Paciente/instrumentação , Decúbito Dorsal , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Terapia com Prótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA