Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Xenobiotica ; 51(2): 202-209, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32930648

RESUMO

Lumefantrine (LFN) is a chiral antimalarial drug. Enantioselective in vitro attributes and absolute oral pharmacokinetics for (-)-LFN and (+)-LFN have been characterized in mice. No stereoselectivity was seen with either of the enantiomers when compared with rac-LFN in the executed in vitro studies (solubility, metabolic stability, protein binding, permeability and blood partitioning). Post intravenous or oral administration of rac-LFN, the AUC0-∞ and MRT of (+)-LFN was higher over (-)-LFN, which is reflected in higher clearance value for (-)-LFN. Following (-)-LFN intravenous administration to mice, the key PK parameters were comparable to (-)-LFN from rac-LFN; however, post intravenous administration of (+)-LFN alone to mice, the AUC0-∞ was 1.3-fold higher than (+)-LFN from rac-LFN. Similarly, post oral administration of (-)-LFN to mice, both AUC0-∞ and Cmax were 1.3-fold higher than (-)-LFN from rac-LFN. On other hand, (+)-LFN showed 1.4-fold higher AUC0-∞ and 1.7-fold higher Cmax post oral administration over (+)-LFN from rac-LFN.


Assuntos
Antimaláricos/farmacocinética , Lumefantrina/farmacocinética , Administração Oral , Animais , Disponibilidade Biológica , Etanolaminas , Infusões Intravenosas , Masculino , Camundongos , Solubilidade , Estereoisomerismo
2.
Biomed Chromatogr ; 34(12): e4953, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32706402

RESUMO

Larotrectinib is a first-generation tropomyosin kinase inhibitor, approved for the treatment of solid tumors. In this paper, we present a validated dried blood spot (DBS) method for the quantitation of larotrectinib from mouse blood using HPLC-MS/MS, which was operated under multiple reaction monitoring mode. To the DBS disc cards, acidified methanol enriched with internal standard (IS; enasidenib) was added and extracted using tert-butyl methyl ether as an extraction solvent with sonication. Chromatographic separation of larotrectinib and the IS was achieved on an Atlantis dC18 column using 10 mm ammonium formate-acetonitrile (30:70, v/v) delivered at a flow-rate of 0.80 ml/min. Under these optimized conditions, the retention times of larotrectinib and the IS were ~0.93 and 1.37 min, respectively. The total run time was 2.50 min. Larotrectinib and the IS were analyzed using positive ion scan mode and parent-daughter mass to charge ion (m/z) transitions of 429.1 → 342.1 and 474.1 → 267.1, respectively, were used for the quantitation. The calibration range was 1.06-5,080 ng/ml. No matrix effect or carryover was observed. Hematocrit did not influence DBS larotrectinib concentrations. All of the validation parameters met the acceptance criteria. The applicability of the validated method was shown in a mouse pharmacokinetic study.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Teste em Amostras de Sangue Seco/métodos , Pirazóis/sangue , Pirimidinas/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Limite de Detecção , Modelos Lineares , Masculino , Camundongos , Pirazóis/química , Pirazóis/farmacocinética , Pirimidinas/química , Pirimidinas/farmacocinética , Reprodutibilidade dos Testes
3.
Drug Res (Stuttg) ; 70(5): 233-238, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32289835

RESUMO

Filgotinib is a selective JAK1 (Janus kinase) inhibitor, filed in Japan for the treatment of rheumatoid arthritis. In this paper, we present the data of development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of filgotinib in mice plasma as per the FDA regulatory guideline. The method involves the extraction of filgotinib along with internal standard (IS, tofacitinib) from mice plasma (100 µL) using ethyl acetate as an extraction solvent. The chromatographic analysis was performed using an isocratic mobile phase comprising 10 mM ammonium acetate (pH 4.5) and acetonitrile (70:30, v/v) at a flow-rate of 0.8 mL/min on a Hypersil Gold C18 column. The UV detection wavelength was set at λmax 300 nm. Filgotinib and the IS eluted at 5.56 and 4.28 min, respectively with a total run time of 10 min. The calibration curve was linear over a concentration range of 0.05 to 5.00 µg/mL (r 2+=≥0.992). The intra- and inter-day precision and accuracy results were within the acceptable limits. Results of stability studies indicated that filgotinib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycles and long-term storage at -80°C. The validated HPLC method was successfully applied to a pharmacokinetic study in mice.


Assuntos
Monitoramento de Medicamentos/métodos , Inibidores de Proteínas Quinases/sangue , Piridinas/sangue , Triazóis/sangue , Administração Oral , Animais , Artrite Reumatoide/tratamento farmacológico , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Monitoramento de Medicamentos/normas , Estabilidade de Medicamentos , Humanos , Masculino , Camundongos , Modelos Animais , Piperidinas/sangue , Inibidores de Proteínas Quinases/administração & dosagem , Inibidores de Proteínas Quinases/farmacocinética , Piridinas/administração & dosagem , Piridinas/química , Piridinas/farmacocinética , Pirimidinas/sangue , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Triazóis/administração & dosagem , Triazóis/química , Triazóis/farmacocinética
4.
Drug Res (Stuttg) ; 70(2-03): 101-106, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31931548

RESUMO

Larotrectinib, is an orally active novel small molecule approved for the treatment of solid tumors in pediatrics and adult patients. It acts by inhibiting tropomyosin receptor kinase. In this paper, we report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of larotrectinib in mice plasma as per the FDA regulatory guideline. Plasma samples processing was accomplished through simple protein precipitation using acetonitrile enriched with internal standard (IS, enasidenib). The chromatographic analysis was performed using a gradient mobile phase comprising 10 mM ammonium acetate and acetonitrile at a flow-rate of 0.8 mL/min on an X-Terra Phenyl column. The UV detection wave length was set at λmax 262 nm. Larotrectinib and the IS eluted at 3.85 and 6.60 min, respectively with a total run time of 8.0 min. The calibration curve was linear over a concentration range of 0.20-5.00 µg/mL (r2=≥0.992). The intra- and inter-day precision and accuracy results were within the acceptable limits. Results of stability studies indicated that larotrectinib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycles and long-term storage at -80°C. The validated HPLC method was successfully applied to a pharmacokinetic study in mice.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Proteínas Quinases/análise , Pirazóis/análise , Pirimidinas/análise , Animais , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Masculino , Camundongos , Inibidores de Proteínas Quinases/farmacocinética , Pirazóis/farmacocinética , Pirimidinas/farmacocinética , Receptores Proteína Tirosina Quinases/antagonistas & inibidores , Reprodutibilidade dos Testes , Temperatura
5.
ADMET DMPK ; 8(1): 113-121, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-35299776

RESUMO

Copanlisib is a pan phosphatidylinositol 3-kinase (PI3K) inhibitor approved for follicular lymphoma. In this paper, we present the data of development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of copanlisib in mice plasma as per the FDA regulatory guideline. The method involves the extraction of copanlisib along with internal standard (IS, enasidenib) from mice plasma (100 µL) using ethyl acetate as an extraction solvent. The chromatographic resolution of copanlisib and the IS was achieved on a Hypersil Gold C18 column maintained at 40 °C using a binary gradient mobile phase [10 mM ammonium formate (pH 4.0) and acetonitrile]. The flow-rate was 0.8 mL/min. For the detection of copanlisib and the IS, the photo-diode array detector was set at λmax 310 nm. Copanlisib and the IS eluted at 6.60 and 7.80 min, respectively with a total run time of 10 min. The calibration curve was linear over a concentration range of 50 to 5000 ng/mL for copanlisib (r2≥ 0.998). The results of intra- and inter-day accuracy and precision studies were within the acceptable limits. Copanlisib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycle and long-term storage at -80 °C. The application of the validated method was shown in a mice pharmacokinetic study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA