Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Int J Cardiol ; 412: 132331, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964556

RESUMO

INTRODUCTION: Spontaneous coronary artery dissection (SCAD) is a rare cause of acute myocardial infarction (AMI), which primarily affects young women without traditional cardiovascular risk factors, often presenting as sudden cardiac death. This study aims to investigate the prevalence, characteristics, predictors, and outcomes of cardiac arrest in SCAD patients. METHODS: The DISCO IT/SPA registry, an international retrospective multicenter study, enrolled 375 SCAD patients from 26 centers in Italy and Spain. Patients were categorized based on the presence or absence of cardiac arrest at admission. Data on demographics, clinical presentation, treatment, angiographic findings, and outcomes were collected. Angiograms were independently reviewed, and outcomes included major adverse cardiovascular events (MACE) and in-hospital bleeding. RESULTS: Among 375 SCAD patients, 20 (5.3%) presented with cardiac arrest. Both groups were similar in age, gender distribution, and conventional risk factors, except for a lower prevalence of dyslipidemia in the cardiac arrest group. ST-segment elevation myocardial infarction (STEMI) presentation and angiographic type 2b were independent predictors of cardiac arrest. Revascularization was more frequent in the cardiac arrest group. In-hospital outcomes, except for longer hospitalization, did not differ. On follow-up (average 21 months), MACE rates were similar between groups. CONCLUSIONS: Cardiac arrest is a notable complication in SCAD, mostly presenting with ventricular fibrillation. The prognosis of SCAD patients presenting with cardiac arrest did not differ from those without, reporting a similar rate of events both in-hospital and during long-term follow-up. STEMI presentation and angiographic type 2b were identified as independent predictors of cardiac arrest in SCAD.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38749449

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

5.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38135568

RESUMO

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Assuntos
Valva Aórtica , Cateterismo Periférico , Artéria Femoral , Punções , Radiografia Intervencionista , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Idoso , Fluoroscopia , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Radiografia Intervencionista/efeitos adversos , Próteses Valvulares Cardíacas , Fatores de Tempo , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Desenho de Prótese
7.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
8.
Int J Cardiol ; 390: 131139, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355239

RESUMO

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda , Fatores de Tempo , Transplante de Coração/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Sistema de Registros , Implante de Prótese de Valva Cardíaca/métodos
11.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35595675

RESUMO

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Cardiovasc Revasc Med ; 40S: 139-143, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34362686

RESUMO

Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a step-by-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
J Cardiovasc Med (Hagerstown) ; 22(12): e37-e40, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34482326

RESUMO

Arterial vasospasm is a well known cause of ischemia and, if prolonged, of parenchymal infarction. The clinical presentation varies according to the involved arterial district. We describe a rare case, which occurred in a young lady, of recurrent and multisystem vasospasm, resulting in multiple cerebral and myocardial infarctions. Our patient was resistant to medical therapy, requiring stent implantation of the involved vessels.


Assuntos
Arteriopatias Oclusivas , Implante de Prótese Vascular , Encéfalo , Artérias Carótidas , Vasoespasmo Coronário , Vasoespasmo Intracraniano , Adulto , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Bloqueadores dos Canais de Cálcio/uso terapêutico , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Artérias Carótidas/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/etiologia , Vasoespasmo Coronário/fisiopatologia , Resistência a Medicamentos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Recidiva , Stents , Resultado do Tratamento , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Vasoespasmo Intracraniano/fisiopatologia
15.
Eur Heart J ; 42(33): 3161-3171, 2021 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-34338759

RESUMO

AIMS: The role of antiplatelet therapy in patients with spontaneous coronary artery dissection (SCAD) undergoing initial conservative management is still a matter of debate, with theoretical arguments in favour and against its use. The aims of this article are to assess the use of antiplatelet drugs in medically treated SCAD patients and to investigate the relationship between single (SAPT) and dual (DAPT) antiplatelet regimens and 1-year patient outcomes. METHODS AND RESULTS: We investigated the 1-year outcome of patients with SCAD managed with initial conservative treatment included in the DIssezioni Spontanee COronariche (DISCO) multicentre international registry. Patients were divided into two groups according to SAPT or DAPT prescription. Primary endpoint was 12-month incidence of major adverse cardiovascular events (MACE) defined as the composite of all-cause death, non-fatal myocardial infarction (MI), and any unplanned percutaneous coronary intervention (PCI). Out of 314 patients included in the DISCO registry, we investigated 199 patients in whom SCAD was managed conservatively. Most patients were female (89%), presented with acute coronary syndrome (92%) and mean age was 52.3 ± 9.3 years. Sixty-seven (33.7%) were given SAPT whereas 132 (66.3%) with DAPT. Aspirin plus either clopidogrel or ticagrelor were prescribed in 62.9% and 36.4% of DAPT patients, respectively. Overall, a 14.6% MACE rate was observed at 12 months of follow-up. Patients treated with DAPT had a significantly higher MACE rate than those with SAPT [18.9% vs. 6.0% hazard ratios (HR) 2.62; 95% confidence intervals (CI) 1.22-5.61; P = 0.013], driven by an early excess of non-fatal MI or unplanned PCI. At multiple regression analysis, type 2a SCAD (OR: 3.69; 95% CI 1.41-9.61; P = 0.007) and DAPT regimen (OR: 4.54; 95% CI 1.31-14.28; P = 0.016) resulted independently associated with a higher risk of 12-month MACE. CONCLUSIONS: In this European registry, most patients with SCAD undergoing initial conservative management received DAPT. Yet, at 1-year follow-up, DAPT, as compared with SAPT, was independently associated with a higher rate of adverse cardiovascular events (ClinicalTrial.gov id: NCT04415762).


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/tratamento farmacológico , Adulto , Vasos Coronários , Dissecação , Quimioterapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Sistema de Registros , Resultado do Tratamento
16.
G Ital Cardiol (Rome) ; 22(9): 704-711, 2021 Sep.
Artigo em Italiano | MEDLINE | ID: mdl-34463678

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) has shown high morbidity and mortality and the relationship between pulmonary embolism (PE) and COVID-19 is well established in the literature. METHODS: We describe the characteristics of a cohort of COVID-19 patients (EP-COV) hospitalized at our Centre with PE, investigating how COVID-19 may have influenced their outcomes, as compared to patients without COVID-19 hospitalized for PE in the same months of 2020 (EP-2020) and 2019 (EP-2019). RESULTS: EP-COV patients (n=25) were younger (60.5 ± 8.5 vs 71.4 ± 14.5 vs 70.9 ± 11.8 years, p=0.003), more frequently male (76% vs 48% vs 35%, p=0.016), with a lower history of neoplasia (12% vs 47% vs 40%, p=0.028) and more clinically severe (SOFA score 3.4 ± 1.4 vs 2.2 ± 1.4 vs 1 ± 1.1, p<0.001 and PaO2/FiO2 ratio 223.8 ± 75.5 vs 306.5 ± 49.3 vs 311.8 ± 107.5) than EP-2020 (n=17) and EP-2019 patients (n=20). D-dimer and C-reactive protein were higher in EP-COV (p=0.038 e p<0.001, respectively). The rate of concomitant deep vein thrombosis associated with PE did not differ significantly between the three groups. EP-COV patients developed PE more frequently during in-hospital stay than non-COVID-19 patients (p = 0.016). The mortality rate was higher in EP-COV than in EP-2020 and EP-2019 patients (36% vs 0% vs 5%, p=0.019). CONCLUSIONS: In our study, the risk factors for PE in COVID-19 patients seem to differ from the traditional risk factors for venous thromboembolism; EP-COV patients are clinically more severe and display a higher mortality rate than EP-2020 and EP-2019 patients.


Assuntos
COVID-19 , Embolia Pulmonar , Tromboembolia Venosa , Idoso , COVID-19/complicações , COVID-19/diagnóstico , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/etiologia , SARS-CoV-2
17.
EuroIntervention ; 17(6): 516-524, 2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-33650491

RESUMO

BACKGROUND: Spontaneous coronary artery dissection (SCAD) is an increasingly diagnosed cause of myocardial infarction. Although different SCAD angiographic classifications exist, their clinical impact remains unknown. AIMS: The aim of this study was to evaluate the relationship between an angiographic classification and the development of adverse clinical events during the follow-up of a large, unselected cohort of patients with SCAD. METHODS: We conducted an observational study of consecutive SCAD patients from 26 centres across Italy and Spain. Cases were classified into five different angiotypes according to the latest classification endorsed by the European Society of Cardiology. The main composite endpoint included all-cause death, non-fatal myocardial infarction (MI), and any unplanned revascularisation. RESULTS: In total, 302 SCAD patients (mean age 51.8±19 years) were followed up for a median of 22 months (IQR 12-48). At 28 days, the composite outcome was higher for the angiotypes with a circumscribed contained intramural haematoma (2A and 3): 20.0% vs 5.4%, p<0.001 (non-fatal MI: 11.0% vs 3.5%, p=0.009; unplanned revascularisation: 11.0% vs 2.5%, p<0.001). This was sustained during follow-up (24.5% vs 9.9%, p=0.001). There were no differences in mortality (0.3% overall). The presence of an angiotype 2A or 3 was an independent predictor of a higher incidence of the composite outcome (adjusted HR 2.44, CI: 1.24-4.80, p=0.010). CONCLUSIONS: The SCAD angiographic classification correlates with outcome. Those presenting with an angiographically circumscribed contained intramural haematoma (angiotypes 2A and 3) showed an increased risk of short-term adverse clinical events that was maintained during follow-up.


Assuntos
Anomalias dos Vasos Coronários , Doenças Vasculares , Adulto , Idoso , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/epidemiologia , Anomalias dos Vasos Coronários/cirurgia , Dissecação , Humanos , Pessoa de Meia-Idade
20.
J Heart Lung Transplant ; 39(12): 1353-1362, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33008726

RESUMO

BACKGROUND: Patients awaiting heart transplantation (HTx) often need bridging therapies to reduce worsening and progression of underlying disease. Limited data are available regarding the use of the MitraClip procedure in secondary mitral regurgitation for this clinical condition. METHODS: We evaluated an international, multicenter (17 centers) registry including 119 patients (median age: 58 years) with moderate-to-severe or severe secondary mitral regurgitation and advanced heart failure (HF) (median left ventricular ejection fraction: 26%) treated with MitraClip as a bridge strategy according to 1 of the following criteria: (1) patients active on HTx list (in list group) (n = 31); (2) patients suitable for HTx but awaiting clinical decision (bridge to decision group) (n = 54); or (3) patients not yet suitable for HTx because of potentially reversible relative contraindications (bridge to candidacy group) (n = 34). RESULTS: Procedural success was achieved in 87.5% of cases, and 30-day survival was 100%. At 1 year, Kaplan-Meier estimates of freedom from the composite primary end-point (death, urgent HTx or left ventricular assist device implantation, first rehospitalization for HF) was 64%. At the time of last available follow-up (median: 532 days), 15% of patients underwent elective transplant, 15.5% remained or could be included in the HTx waiting list, and 23.5% had no more indication to HTx because of clinical improvement. CONCLUSIONS: MitraClip procedure as a bridge strategy to HTx in patients with advanced HF with significant mitral regurgitation was safe, and two thirds of patients remained free from adverse events at 1 year. These findings should be considered exploratory and hypothesis-generating to guide further study for percutaneous intervention in high-risk patients with advanced HF.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Sistema de Registros , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA