Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38870348

RESUMO

AIMS: Patients with persistent atrial fibrillation (AF) experience 50% recurrence despite pulmonary vein isolation (PVI), and no consensus is established for secondary treatments. The aim of our i-STRATIFICATION study is to provide evidence for stratifying patients with AF recurrence after PVI to optimal pharmacological and ablation therapies, through in silico trials. METHODS AND RESULTS: A cohort of 800 virtual patients, with variability in atrial anatomy, electrophysiology, and tissue structure (low-voltage areas, LVAs), was developed and validated against clinical data from ionic currents to electrocardiogram. Virtual patients presenting AF post-PVI underwent 12 secondary treatments. Sustained AF developed in 522 virtual patients after PVI. Second ablation procedures involving left atrial ablation alone showed 55% efficacy, only succeeding in the small right atria (<60 mL). When additional cavo-tricuspid isthmus ablation was considered, Marshall-PLAN sufficed (66% efficacy) for the small left atria (<90 mL). For the bigger left atria, a more aggressive ablation approach was required, such as anterior mitral line (75% efficacy) or posterior wall isolation plus mitral isthmus ablation (77% efficacy). Virtual patients with LVAs greatly benefited from LVA ablation in the left and right atria (100% efficacy). Conversely, in the absence of LVAs, synergistic ablation and pharmacotherapy could terminate AF. In the absence of ablation, the patient's ionic current substrate modulated the response to antiarrhythmic drugs, being the inward currents critical for optimal stratification to amiodarone or vernakalant. CONCLUSION: In silico trials identify optimal strategies for AF treatment based on virtual patient characteristics, evidencing the power of human modelling and simulation as a clinical assisting tool.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Humanos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Antiarrítmicos/uso terapêutico , Resultado do Tratamento , Modelos Cardiovasculares , Simulação por Computador , Potenciais de Ação , Medição de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Masculino , Anisóis/uso terapêutico , Seleção de Pacientes , Feminino , Modelagem Computacional Específica para o Paciente , Pessoa de Meia-Idade , Pirrolidinas/uso terapêutico , Eletrocardiografia , Tomada de Decisão Clínica
2.
ESC Heart Fail ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649305

RESUMO

AIMS: The trials upon which recommendations for the use of cardiac resynchronization therapy (CRT) in heart failure used optimal medical therapy (OMT) before sodium-glucose co-transporter 2 inhibitors (SGLT2i). Moreover, the SGLT2i heart failure trials included only a small proportion of participants with CRT, and therefore, it remains uncertain whether SGLT2i should be considered part of OMT prior to CRT. METHODS AND RESULTS: We compared electrocardiogram (ECG) and echocardiographic responses to CRT as well as hospitalization and mortality rates in consecutive patients undergoing implantation at a large tertiary centre between January 2019 to June 2022 with and without SGLT2i treatment. Three hundred seventy-four participants were included aged 74.0 ± 11.5 years (mean ± standard deviation), with a left ventricular ejection fraction (LVEF) of 31.8 ± 9.9% and QRS duration of 161 ± 29 ms. The majority had non-ischaemic cardiomyopathy (58%) and were in NYHA Class II/III (83.6%). These characteristics were similar between patients with (n = 66) and without (n = 308) prior SGLT2i treatment. Both groups demonstrated similar evidence of response to CRT in terms of QRS duration shortening, and improvements in LVEF, left ventricular end-diastolic inner-dimension (LVIDd) and diastolic function (E/A and e/e'). While there was no difference in rates of hospitalization (for heart failure or overall), mortality was significantly lower in patients treated with SGLT2i compared with those who were not (6.5 vs. 16.6%, P = 0.049). CONCLUSIONS: We observed an improvement in mortality in patients undergoing CRT prescribed SGLT2i compared with those not prescribed SGLT2i, despite similar degrees of reverse remodelling. The authors recommend starting SGLT2i prior to CRT implantation, where it does not delay implantation.

3.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
4.
J Cardiovasc Electrophysiol ; 35(1): 146-154, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37888415

RESUMO

INTRODUCTION: Fusion pacing requires correct timing of left ventricular pacing to right ventricular activation, although it is unclear whether this is maintained when atrioventricular (AV) conduction changes during exercise. We used cardiopulmonary exercise testing (CPET) to compare cardiac resynchronization therapy (CRT) using fusion pacing or fixed AV delays (AVD). METHODS: Patients 6 months post-CRT implant with PR intervals < 250 ms performed two CPET tests, using either the SyncAV™ algorithm or fixed AVD of 120 ms in a double-blinded, randomized, crossover study. All other programming was optimized to produce the narrowest QRS duration (QRSd) possible. RESULTS: Twenty patients (11 male, age 71 [65-77] years) were recruited. Fixed AVD and fusion programming resulted in similar narrowing of QRSd from intrinsic rhythm at rest (p = .85). Overall, there was no difference in peak oxygen consumption (V̇O2 PEAK , p = .19), oxygen consumption at anaerobic threshold (VT1, p = .42), or in the time to reach either V̇O2 PEAK (p = .81) or VT1 (p = .39). The BORG rating of perceived exertion was similar between groups. CPET performance was also analyzed comparing whichever programming gave the narrowest QRSd at rest (119 [96-136] vs. 134 [119-142] ms, p < .01). QRSd during exercise (p = .03), peak O2 pulse (mL/beat, a surrogate of stroke volume, p = .03), and cardiac efficiency (watts/mL/kg/min, p = .04) were significantly improved. CONCLUSION: Fusion pacing is maintained during exercise without impairing exercise capacity compared with fixed AVD. However, using whichever algorithm gives the narrowest QRSd at rest is associated with a narrower QRSd during exercise, higher peak stroke volume, and improved cardiac efficiency.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Estudos Cross-Over , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Frequência Cardíaca , Resultado do Tratamento , Eletrocardiografia
5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37470443

RESUMO

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Frequência Cardíaca , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas , Recidiva , Fatores de Tempo , Átrios do Coração , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
7.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
8.
Artigo em Inglês | MEDLINE | ID: mdl-35835888

RESUMO

The implantable cardioverter-defibrillator (ICD) is a proven treatment for preventing sudden cardiac death. Transvenous leads are associated with significant mortality and morbidity, and the subcutaneous ICD (S-ICD) addresses this. However, it is not without limitations, in particular the absence of anti-tachycardia pacing. The decision of which device is most suitable for an individual patient is often complex. Here, we review the relative merits and weaknesses of both the transvenous and S-ICD. We summarise the available evidence for each device in particular patient cohorts, namely: ischaemic and non-ischaemic cardiomyopathy, idiopathic ventricular fibrillation, Brugada syndrome, long QT syndrome, arrhythmogenic right ventricular cardiomyopathy, and hypertrophic cardiomyopathy.

9.
Card Electrophysiol Clin ; 14(2): 283-296, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35715086

RESUMO

Although cardiac resynchronization therapy (CRT) has become well established in the treatment of heart failure, the management of patients who do not respond after CRT remains a key challenge. This review will summarize what we have learned about non-responders over the last 20 years and discuss methods for optimizing response, including the introduction of novel therapies.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
10.
Arrhythm Electrophysiol Rev ; 11: e06, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35755327

RESUMO

Results from catheter ablation for persistent AF are suboptimal, with no strategy other than pulmonary vein isolation showing clear benefit. Recently employed empirical strategies beyond pulmonary vein isolation involve widespread atrial ablation in all patients and do not take into account patient-specific differences in AF mechanisms or phenotype. Charge density mapping using the non-contact AcQMap system (Acutus Medical) allows visualisation of whole-chamber activation during AF and reveals localised patterns of complex activation thought to represent important mechanisms for AF maintenance that can be targeted with focal ablation. In this review, the authors outline the fundamentals of this technology, the initial data exploring the mechanistic role of activation patterns seen and the application to ablation of persistent AF.

11.
J Am Heart Assoc ; 11(11): e021166, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35621197

RESUMO

Background Adenosine shortens action potential duration and refractoriness and provokes atrial fibrillation. This study aimed to evaluate the effect of adenosine on mechanisms of wavefront propagation during atrial fibrillation. Methods and Results The study included 22 patients undergoing catheter ablation for persistent atrial fibrillation. Left atrial mapping was performed using the AcQMap charge density system before and after administration of intravenous adenosine at 1 or more of 3 time points during the procedure (before pulmonary vein isolation, after pulmonary vein isolation, and after nonpulmonary vein isolation ablation). Wave-front propagation patterns were evaluated allowing identification and quantification of localized rotational activation (LRA), localized irregular activation, and focal firing. Additional signal processing was performed to identify phase singularities and calculate global atrial fibrillation cycle length and dominant frequency. A total of 35 paired maps were analyzed. Adenosine shortened mean atrial fibrillation cycle length from 181.7±14.3 to 165.1±16.3, (mean difference 16.6 ms; 95% CI, 11.3-21.9, P<0.0005) and increased dominant frequency from 6.0±0.7 Hz to 6.6±0.8 Hz (95% CI, 0.4-0.9, P<0.0005). This was associated with a 50% increase in the number of LRA occurrences (16.1±7.6-24.2±8.1; mean difference 8.1, 95% CI, 4.1-12, P<0.0005) as well as a 20% increase in the number of phase singularities detected (30.1±7.8-36.6±9.3; mean difference 6.5; 95% CI, 2.6-10.0, P=0.002). The percentage of left atrial surface area with LRA increased with adenosine and 42 of 70 zones (60%) with highest density of LRA coincided with high density LRA zones at baseline with only 28% stable across multiple maps. Conclusions Adenosine accelerates atrial fibrillation and promotes rotational activation patterns with no impact on focal activation. There is little evidence that rotational activation seen with adenosine represents promising targets for ablation aimed at sites of stable arrhythmogenic sources in the left atrium.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
12.
Europace ; 24(10): 1569-1584, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35640891

RESUMO

AIMS: Catheter ablation for atrial fibrillation (AF) has historically required inpatient admission post-procedure, but same-day discharge (SDD) has recently been reported. We aimed to assess the efficacy and safety of SDD compared with overnight stay (OS) post-ablation. METHODS AND RESULTS: We performed a systematic search of the PubMed database. Random-effects meta-analysis was performed to assess the efficacy (successful SDD) and safety (24 h complications, 30-day complications, 30-day re-admissions, and 30-day mortality) of a SDD AF ablation strategy. Fourteen non-randomized observational studies met criteria for inclusion, encompassing 26488 patients undergoing AF ablation, of whom 9766 were SDD. The mean age of participants was 61.9 years, and 67.9% were male. Around 61.7% underwent ablation for paroxysmal AF. The pooled success rate of SDD was 83.2% [95% confidence intervals (CIs): 61.5-97.0%, I2 100%]. The risk of bias was severe for all effect estimates due to confounding, as most cohorts were retrospectively identified without appropriately matched comparators. There was no significant difference in 30-day complications [odds ratio (OR): 0.95, 95% CI: 0.65-1.40, I2 53%] or 30-day re-admission (OR 0.96, 95% CI: 0.49-1.89, I2 82%) between groups. There were insufficient data for meta-analysis of 24 h complications and 30-day mortality. Where reported, no re-admissions occurred due to 24 h complications after SDD. Two deaths (0.04%) were reported in both SDD and OS groups. CONCLUSION: Same-day discharge after AF ablation appears to be an effective and safe strategy in selected patients. However, the available evidence is of low quality, and more robust prospective studies comparing SDD to OS are needed.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Alta do Paciente , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Clin Med (Lond) ; 22(1): 77-82, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35078798

RESUMO

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and a growing public health epidemic. In the UK, over 1.3 million people have a diagnosis of AF and an estimated 400,000 remain undiagnosed. AF-related strokes account for a quarter of all strokes and, as AF episodes are often asymptomatic, are still often the first manifestation of AF. Early diagnosis and initiation of oral anticoagulation, where appropriate, may prevent some of these thromboembolic strokes. Public Health England is committed to decrease the incidence of AF-related strokes and has sponsored initiatives aimed at improving AF detection by promoting the uptake of wearable technologies. However, the National Institute for Health and Care Excellence (NICE) has not recommended wearable technology in their recent AF diagnosis and management guidelines (NG196). Diagnostic accuracy of single-lead electrocardiography (ECG) generated by the latest iteration of wearable devices is excellent and, in many cases, superior to general practitioner interpretation of the 12-lead ECG. High-quality ECG from wearable devices that unequivocally shows AF can expedite AF detection. Otherwise, there is a real risk of delaying AF diagnosis with the potential of devastating consequences for patients and their families.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Dispositivos Eletrônicos Vestíveis , Fibrilação Atrial/diagnóstico , Diagnóstico Precoce , Eletrocardiografia , Humanos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle
14.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
Europace ; 24(5): 747-754, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34871398

RESUMO

AIMS: SuperMap is a novel non-contact algorithm for the mapping of organized atrial arrhythmias. We prospectively evaluated SuperMap during mapping and ablation of atrial tachycardias (ATs) and paced rhythms and compared to conventional high-density contact mapping. METHODS AND RESULTS: Consecutive patients undergoing SuperMap guided ablation of pre-existing ATs or AT developed during atrial fibrillation ablation procedures were included together with maps obtained during pacing to assess block in linear lesions. The time taken to obtain diagnostic maps was measured together with the number of electrogram (EGM) points and accuracy compared to the arrhythmia diagnosis confirmed using a combination of map findings, entrainment, and response to ablation. In a subgroup of patients, concurrent contact mapping was performed with contact and SuperMap analysed by separate operators blinded to the other technique. The time taken to generate a diagnostic map, EGM number, and map accuracy was compared. Thirty-one patients (62 maps) were included with contact mapping performed in 19 [39 maps (33 for AT)]. SuperMap acquisition time was 314 s [interquartile range (IQR) 239-436]. The median number of EGM points used per map was 5399 (IQR 3279-8677). SuperMap was faster than contact mapping [394 ± 219 s vs. 611 ± 331 s; difference 217 s, 95% confidence interval (CI) 116-318, P < 0.0005]. The number of EGM points used per map was higher for SuperMap (7351 ± 5054 vs. 3620 ± 3211; difference 3731, 95% CI 2073-5388, P < 0.0005). SuperMap and contact mapping were accurate in 92% and 85% of maps, respectively, P = 0.4805. CONCLUSION: SuperMap non-contact charge density mapping is a rapid and reliable approach to guide the ablation of complex atrial arrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Resultado do Tratamento
16.
J Intensive Care Soc ; 23(4): 414-424, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36751347

RESUMO

Background: New-onset atrial fibrillation (NOAF) is common during critical illness and is associated with poor outcomes. Many risk factors for NOAF during critical illness have been identified, overlapping with risk factors for atrial fibrillation in patients in community settings. To develop interventions to prevent NOAF during critical illness, modifiable risk factors must be identified. These have not been studied in detail and it is not clear which variables warrant further study. Methods: We undertook an international three-round Delphi process using an expert panel to identify important predictors of NOAF risk during critical illness. Results: Of 22 experts invited, 12 agreed to participate. Participants were located in Europe, North America and South America and shared 110 publications on the subject of atrial fibrillation. All 12 completed the three Delphi rounds. Potentially modifiable risk factors identified include 15 intervention-related variables. Conclusions: We present the results of the first Delphi process to identify important predictors of NOAF risk during critical illness. These results support further research into modifiable risk factors including optimal plasma electrolyte concentrations, rates of change of these electrolytes, fluid balance, choice of vasoactive medications and the use of preventative medications in high-risk patients. We also hope our findings will aid the development of predictive models for NOAF.

18.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 32(9): 2393-2403, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34260134

RESUMO

BACKGROUND: Charge density mapping of atrial fibrillation (AF) reveals dynamic localized rotational activation (LRA), irregular activation (LIA) and focal firing (FF). Their spatial stability, conduction characteristics and the optimal duration of mapping required to reveal these phenomena and has not been explored. METHODS: Bi-atrial mapping of AF propagation was undertaken using AcQMap (Acutus Medical) and variability of activation patterns quantified up to a duration of 30 s. The frequency of each pattern was quantified at each unique point of the chamber over two separate 30-s recordings before ablation and R2 calculated to quantify spatial stability. Regions with the highest frequency were identified at increasing time durations and compared to the result over 30 s using Cohen's kappa. Properties of regions with the most stable patterns were assessed during sinus rhythm and extrastimulus pacing. RESULTS: In 21 patients, 62 paired LA and RA maps were obtained. LIA was highly spatially stable with R2 between maps of 0.83 (0.71-0.88) compared to 0.39 (0.24-0.57), and 0.64 (0.54-0.73) for LRA and FF, respectively. LIA was most temporally stable with a kappa of >0.8 reached by 12 s. LRA showed greatest variability with kappa >0.8 only after 22 s. Regions of LIA were of normal voltage amplitude (1.09 mv) but showed increased conduction heterogeneity during extrastimulus pacing (p = .0480). CONCLUSION: Irregular activation patterns characterized by changing wavefront direction are temporally and spatially stable in contrast with LRA that is transient with least spatial stability. Focal activation appears of intermediate stability. Regions of LIA show increased heterogeneity following extrastimulus pacing and may represent fixed anatomical substrate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco , Frequência Cardíaca , Humanos
20.
Heart Rhythm ; 18(10): 1724-1732, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34126270

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) has been widely adopted as a strategy for stroke prevention in patients with atrial fibrillation ineligible for oral anticoagulation. OBJECTIVE: The purpose of this study was to explore longer-term "real-world" safety and efficacy outcomes in patients undergoing LAAO given varied practices in antithrombotic regimens and adoption of same-day discharge. METHODS: Analysis of acute procedural and long-term outcome data was performed for all patients undergoing LAAO implant in a United Kingdom tertiary center over an 11-year period. Rates of adverse events were calculated and compared to predicted rates in historical cohorts according to CHA2DS2-VASc and HAS-BLED scores. RESULTS: Device implantation was attempted in 229 patients, with an acute procedural success rate of 98.2% and low rate of major procedural complications of 2.6% at 30 days, including 1.3% procedure-related mortality. In the last year of enrollment, 75% of patients were discharged on the same day of the procedure. A strategy of early cessation of antithrombotic therapy was adopted, with a low rate of device-related thrombus. Over total follow-up of 889 patient-years, there were low rates of thromboembolic events (2.2/100 patient-years) and of significant bleeding events (intracranial bleed 0.6/100 patient-years; nonprocedural major bleeding 2.3/100 patient-years). CONCLUSION: LAAO with a same-day discharge strategy and early cessation of antiplatelet therapy seems to be safe and effective in reducing the risk of stroke and major bleeding over mean follow-up approaching 4 years. Although these data are reassuring, results from randomized trials with strict shorter periods of postprocedural antithrombotic therapy are eagerly awaited.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Previsões , Sistema de Registros , Medição de Risco/métodos , Tromboembolia/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Cateterismo Cardíaco/métodos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Resultado do Tratamento , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA