Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Cardiovasc Eng Technol ; 14(5): 617-630, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37582997

RESUMO

PURPOSE: Image-based blood flow simulations are increasingly used to investigate the hemodynamics in intracranial aneurysms (IAs). However, a strong variability in segmentation approaches as well as the absence of individualized boundary conditions (BCs) influence the quality of these simulation results leading to imprecision and decreased reliability. This study aims to analyze these influences on relevant hemodynamic parameters within IAs. METHODS: As a follow-up study of an international multiple aneurysms challenge, the segmentation results of five IAs differing in size and location were investigated. Specifically, five possible outlet BCs were considered in each of the IAs. These are comprised of the zero-pressure condition (BC1), a flow distribution based on Murray's law with the exponents n = 2 (BC2) and n = 3 (BC3) as well as two advanced flow-splitting models considering the real vessels by including circular cross sections (BC4) or anatomical cross sections (BC5), respectively. In total, 120 time-dependent blood flow simulations were analyzed qualitatively and quantitatively, focusing on five representative intra-aneurysmal flow and five shear parameters such as vorticity and wall shear stress. RESULTS: The outlet BC variation revealed substantial differences. Higher shear stresses (up to Δ9.69 Pa), intrasaccular velocities (up to Δ0.15 m/s) and vorticities (up to Δ629.22 1/s) were detected when advanced flow-splitting was applied compared to the widely used zero-pressure BC. The tendency of outlets BCs to over- or underestimate hemodynamic parameters is consistent across different segmentations of a single aneurysm model. Segmentation-induced variability reaches Δ19.58 Pa, Δ0.42 m/s and Δ957.27 1/s, respectively. Excluding low fidelity segmentations, however, (a) reduces the deviation drastically (>43%) and (b) leads to a lower impact of the outlet BC on hemodynamic predictions. CONCLUSION: With a more realistic lumen segmentation, the influence of the BC on the resulting hemodynamics is decreased. A realistic lumen segmentation can be ensured, e.g., by using high-resolved 2D images. Furthermore, the selection of an advanced outflow-splitting model is advised and the use of a zero-pressure BC and BC based on Murray's law with exponent n = 3 should be avoided.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Reprodutibilidade dos Testes , Seguimentos , Hemodinâmica/fisiologia , Estresse Mecânico , Modelos Cardiovasculares
2.
BMJ Open ; 12(11): e063051, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36351732

RESUMO

OBJECTIVES: Assessing the risk associated with unruptured intracranial aneurysms (IAs) is essential in clinical decision making. Several geometric risk parameters have been proposed for this purpose. However, performance of these parameters has been inconsistent. This study evaluates the performance and robustness of geometric risk parameters on two datasets and compare it to the uncertainty inherent in assessing these parameters and quantifies interparameter correlations. METHODS: Two datasets containing 244 ruptured and unruptured IA geometries from 178 patients were retrospectively analysed. IAs were stratified by anatomical region, based on the PHASES score locations. 37 geometric risk parameters representing four groups (size, neck, non-dimensional, and curvature parameters) were assessed. Analysis included standardised absolute group differences (SADs) between ruptured and unruptured IAs, ratios of SAD to median relative uncertainty (MRU) associated with the parameters, and interparameter correlation. RESULTS: The ratio of SAD to MRU was lower for higher dimensional size parameters (ie, areas and volumes) than for one-dimensional size parameters. Non-dimensional size parameters performed comparatively well with regard to SAD and MRU. SAD was higher in the posterior anatomical region. Correlation of parameters was strongest within parameter (sub)groups and between size and curvature parameters, while anatomical region did not strongly affect correlation patterns. CONCLUSION: Non-dimensional parameters and few parameters from other groups were comparatively robust, suggesting that they might generalise better to other datasets. The data on discriminative performance and interparameter correlations presented in this study may aid in developing and choosing robust geometric parameters for use in rupture risk models.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Incerteza , Pescoço , Fatores de Risco , Angiografia Cerebral/métodos
3.
Int J Comput Assist Radiol Surg ; 17(7): 1355-1366, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35278155

RESUMO

PURPOSE: To create an accurate 3D reconstruction of the vascular trees, it is necessary to know the exact geometrical parameters of the angiographic imaging system. Many previous studies used vascular structures to estimate the system's exact geometry. However, utilizing interventional devices and their relative features may be less challenging, as they are unique in different views. We present a semi-automatic self-calibration approach considering the markers attached to the interventional instruments to estimate the accurate geometry of a biplane X-ray angiography system for neuroradiologic use. METHODS: A novel approach is proposed to detect and segment the markers using machine learning classification, a combination of support vector machine and boosted tree. Then, these markers are considered as reference points to optimize the acquisition geometry iteratively. RESULTS: The method is evaluated on four clinical datasets and three pairs of phantom angiograms. The mean and standard deviation of backprojection error for the catheter or guidewire before and after self-calibration are [Formula: see text] mm and [Formula: see text] mm, respectively. The mean and standard deviation of the 3D root-mean-square error (RMSE) for some markers in the phantom reduced from [Formula: see text] to [Formula: see text] mm. CONCLUSION: A semi-automatic approach to estimate the accurate geometry of the C-arm system was presented. Results show the reduction in the 2D backprojection error as well as the 3D RMSE after using our proposed self-calibration technique. This approach is essential for 3D reconstruction of the vascular trees or post-processing techniques of angiography systems that rely on accurate geometry parameters.


Assuntos
Angiografia , Imageamento Tridimensional , Angiografia/métodos , Calibragem , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas
4.
Stroke ; 53(3): 769-778, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34547927

RESUMO

BACKGROUND AND PURPOSE: The purpose of the COMPLETE (International Acute Ischemic Stroke Registry With the Penumbra System Aspiration Including the 3D Revascularization Device) registry was to evaluate the generalizability of the safety and efficacy of the Penumbra System (Penumbra, Inc, Alameda) in a real-world setting. METHODS: COMPLETE was a global, prospective, postmarket, multicenter registry. Patients with large vessel occlusion-acute ischemic stroke who underwent mechanical thrombectomy using the Penumbra System with or without the 3D Revascularization Device as frontline approach were enrolled at 42 centers (29 United States, 13 Europe) from July 2018 to October 2019. Primary efficacy end points were successful postprocedure angiographic revascularization (modified Thrombolysis in Cerebral Infarction ≥2b) and 90-day functional outcome (modified Rankin Scale score 0-2). The primary safety end point was 90-day all-cause mortality. An imaging core lab determined modified Thrombolysis in Cerebral Infarction scores, Alberta Stroke Program Early CT Scores, clot location, and occurrence of intracranial hemorrhage at 24 hours. Independent medical reviewers adjudicated safety end points. RESULTS: Six hundred fifty patients were enrolled (median age 70 years, 54.0% female, 49.2% given intravenous recombinant tissue-type plasminogen activator before thrombectomy). Rate of modified Thrombolysis in Cerebral Infarction 2b to 3 postprocedure was 87.8% (95% CI, 85.3%-90.4%). First pass and postprocedure rates of modified Thrombolysis in Cerebral Infarction 2c to 3 were 41.5% and 66.2%, respectively. At 90 days, 55.8% (95% CI, 51.9%-59.7%) had modified Rankin Scale score 0 to 2, and all-cause mortality was 15.5% (95% CI, 12.8%-18.3%). CONCLUSIONS: Using Penumbra System for frontline mechanical thrombectomy treatment of patients with large vessel occlusion-acute ischemic stroke in a real-world setting was associated with angiographic, clinical, and safety outcomes that were comparable to prior randomized clinical trials with stringent site and operator selection criteria. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03464565.


Assuntos
Angiografia Cerebral , AVC Isquêmico , Trombólise Mecânica , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Comput Methods Programs Biomed ; 210: 106372, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34474194

RESUMO

BACKGROUND AND OBJECTIVE: MeshCNN is a recently proposed Deep Learning framework that drew attention due to its direct operation on irregular, non-uniform 3D meshes. It outperformed state-of-the-art methods in classification and segmentation tasks of popular benchmarking datasets. The medical domain provides a large amount of complex 3D surface models that may benefit from processing with MeshCNN. However, several limitations prevent outstanding performances on highly diverse medical surface models. Within this work, we propose MedMeshCNN as an expansion dedicated to complex, diverse, and fine-grained medical data. METHODS: MedMeshCNN follows the functionality of MeshCNN with a significantly increased memory efficiency that allows retaining patient-specific properties during processing. Furthermore, it enables the segmentation of pathological structures that often come with highly imbalanced class distributions. RESULTS: MedMeshCNN achieved an Intersection over Union of 63.24% on a highly complex part segmentation task of intracranial aneurysms and their surrounding vessel structures. Pathological aneurysms were segmented with an Intersection over Union of 71.4%. CONCLUSIONS: MedMeshCNN enables the application of MeshCNN on complex, fine-grained medical surface meshes. It considers imbalanced class distributions derived from pathological findings and retains patient-specific properties during processing.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Humanos
6.
Int J Comput Assist Radiol Surg ; 16(11): 1977-1984, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34406578

RESUMO

PURPOSE: Intracranial aneurysms are local dilations of brain vessels. Their rupture, as well as their treatment, is associated with high risk of morbidity and mortality. In this work, we propose shape indices for aneurysm ostia for the rupture risk assessment of intracranial aneurysms. METHODS: We analyzed 84 middle cerebral artery bifurcation aneurysms (27 ruptured and 57 unruptured) and their ostia, with respect to their size and shape. We extracted 3D models of the aneurysms and vascular trees. A semi-automatic approach was used to separate the aneurysm from its parent vessel and to reconstruct the ostium. We used known indices to quantitatively describe the aneurysms. For the ostium, we present new shape indices: the 2D Undulation Index (UI[Formula: see text]), the 2D Ellipticity Index (EI[Formula: see text]) and the 2D Noncircularity Index (NCI[Formula: see text]). Results were analyzed using the Student t test, the Mann-Whitney U test and a correlation analysis between indices of the aneurysms and their ostia. RESULTS: Of the indices, none was significantly associated with rupture status. Most aneurysms have an NCI[Formula: see text] below 0.2. Of the aneurysms that have an NCI[Formula: see text] above 0.5, only one is ruptured, which indicates that ruptured aneurysms often have a circular-shaped ostium. Furthermore, the ostia of ruptured aneurysms tend to have a smaller area, which is also correlated with the aneurysm's size. While also other variables were significantly correlated, strong linear correlations can only be seen between the area of the ostium with the aneurysm's volume and surface. CONCLUSION: The proposed shape indices open up new possibilities to quantitatively describe and compare ostia, which can be beneficial for rupture risk assessment and subsequent treatment decision. Additionally, this work shows that the ostium area and the size of the aneurysm are correlated. Further longitudinal studies are necessary to analyze whether stable and unstable aneurysms can be distinguished by their ostia.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Aneurisma Roto/diagnóstico por imagem , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Medição de Risco
7.
BMC Neurol ; 21(1): 228, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34157987

RESUMO

BACKROUND: We describe one of the first cases of a Posterior reversible encephalopathy syndrome (PRES) under tocilizumab as treatment of Giant cell arteritis (GCA). CASE PRESENTATION: A 65-year-old female with known GCA and treatment with Tocilizumab (TCZ) developed a convulsive epileptic seizure for the first time. MRI was suggestive of PRES and an associated left sided occipital hemorrhage. Extensive high blood pressure values were not detected. The patient recovered within a week and no further seizures occurred under anticonvulsive medication. CONCLUSION: PRES during the treatment with Tocilizumab hasn't been described in GCA so far. There are single reports of an association between TCZ and PRES in other entities. Thus, a link between interleukin-6 and the integrity of the vasculature could be considered. The clinical consequence should be a stringent blood pressure monitoring in the ambulant setting of patients receiving TCZ.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Arterite de Células Gigantes/tratamento farmacológico , Síndrome da Leucoencefalopatia Posterior/diagnóstico , Idoso , Anticorpos Monoclonais Humanizados/uso terapêutico , Feminino , Arterite de Células Gigantes/patologia , Hemorragia/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Síndrome da Leucoencefalopatia Posterior/diagnóstico por imagem , Síndrome da Leucoencefalopatia Posterior/etiologia
8.
Cardiovasc Eng Technol ; 12(4): 454-465, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34100225

RESUMO

PURPOSE: For the status evaluation of intracranial aneurysms (IAs), morphological and hemodynamic parameters can provide valuable information. For their extraction, a separation of the aneurysm sac from its parent vessel is required that yields the neck curve and the ostium. However, manual and subjective neck curve and ostium definitions might lead to inaccurate IA assessments. METHODS: The research project VICTORIA was initiated, allowing users to interactively define the neck curve of five segmented IA models using a web application. The submitted results were qualitatively and quantitatively compared to identify the minimum, median and maximum aneurysm surface area. Finally, image-based blood flow simulations were carried out to assess the effect of variable neck curve definitions on relevant flow- and shear-related parameters. RESULTS: In total, 55 participants (20 physicians) from 18 countries participated in VICTORIA. For relatively simple aneurysms, a good agreement with respect to the neck curve definition was found. However, differences among the participants increased with increasing complexity of the aneurysm. Furthermore, it was observed that the majority of participants excluded any small arteries occurring in the vicinity of an aneurysm. This can lead to non-negligible deviations among the flow- and shear-related parameters, which need to be carefully evaluated, if quantitative analysis is desired. Finally, no differences between participants with medical and non-medical background could be observed. CONCLUSIONS: VICTORIAs findings reveal the complexity of aneurysm neck curve definition, especially for bifurcation aneurysms. Standardization appears to be mandatory for future sac-vessel-separations. For hemodynamic simulations a careful neck curve definition is crucial to avoid inaccuracies during the quantitative flow analysis.


Assuntos
Aneurisma Intracraniano , Hemodinâmica , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia
9.
Front Neurol ; 12: 771694, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35140672

RESUMO

Numerous studies assess intracranial aneurysm rupture risk based on morphological and hemodynamic parameter analysis in addition to clinical information such as aneurysm localization, age, and sex. However, intracranial aneurysms mostly occur with a saccular shape located either lateral to the parent artery or at a bifurcation. In contrast, fusiform intracranial aneurysms (FIAs), i.e., aneurysms with a non-saccular, dilated form, occur in approximately 3-13% of all cases and therefore have not yet been as thoroughly studied. To improve the understanding of FIA hemodynamics, this pilot study contains morphological analyses and image-based blood flow simulations in three patient-specific cases. For a precise and realistic comparison to the pre-pathological state, each dilation was manually removed and the time-dependent blood flow simulations were repeated. Additionally, a validated fast virtual stenting approach was applied to evaluate the effect of virtual endovascular flow-diverter deployment focusing on relevant hemodynamic quantities. For two of the three patients, post-interventional information was available and included in the analysis. The results of this numerical pilot study indicate that complex flow structures, i.e., helical flow phenomena and the presence of high oscillating flow features, predominantly occur in FIAs with morphologically differing appearances. Due to the investigation of the individual healthy states, the original flow environment could be restored which serves as a reference for the virtual treatment target. It was shown that the realistic deployment led to a considerable stabilization of the individual hemodynamics in all cases. Furthermore, a quantification of the stent-induced therapy effect became feasible for the treating physician. The results of the morphological and hemodynamic analyses in this pilot study show that virtual stenting can be used in FIAs to quantify the effect of the planned endovascular treatment.

10.
J Neurointerv Surg ; 13(6): 541-546, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32900908

RESUMO

BACKGROUND: Flow diverters (FD) are used regularly for the endovascular treatment of unruptured intracranial aneurysms. We aimed to assess the safety and effectiveness of the Derivo embolization device (DED) with respect to long-term clinical and angiographic outcomes. METHODS: A prospective multicenter trial was conducted at 12 centers. Patients presenting with modified Rankin Score (mRS) of 0-1, treated for unruptured intracranial aneurysms with DED were eligible. Primary endpoint was the mRS assessed at 18 months with major morbidity defined as mRS 3-5. Satisfactory angiographic occlusion was defined as 3+4 on the Kamran scale. RESULTS: Between July 2014 and February 2018, 119 patients were enrolled. Twenty-three patients were excluded. Ninety-six patients, 71 (74%) female, mean age 54±12.0 years, were included in the analysis. Mean aneurysm size was 14.2±16.9 mm. The mean number of devices implanted per patient was 1.2 (range 1-3). Clinical follow-up at 18 months was available in 90 (94%) patients, resulting in a mean follow-up period of 14.8±5.2 months. At last available follow-up of 96 enrolled patients, 91 (95%) remained mRS 0-1. The major morbidity rate (mRS 3-5) was 3.1% (3/96), major stroke rate was 4.2% (4/96), and mortality was 0%. Follow-up angiographies were available in 89 (93%) patients at a median of 12.4±5.84 months with a core laboratory adjudicated satisfactory aneurysm occlusion in 89% (79/89). CONCLUSION: Our results suggest that DED is a safe and effective treatment for unruptured aneurysms with high rates of satisfactory occlusion and comparably low rates of permanent neurological morbidity and mortality. TRIAL REGISTRATION: DRKS00006103.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Idoso , Angiografia Cerebral/métodos , Procedimentos Endovasculares/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
Neurology ; 96(3): e343-e351, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33144517

RESUMO

OBJECTIVE: To determine whether thrombectomy is safe in children up to 24 hours after onset of symptoms when selected by mismatch between clinical deficit and infarct. METHODS: A secondary analysis of the Save ChildS Study (January 2000-December 2018) was performed, including all pediatric patients (<18 years) diagnosed with arterial ischemic stroke who underwent endovascular recanalization at 27 European and United States stroke centers. Patients were included if they had a relevant mismatch between clinical deficit and infarct. RESULTS: Twenty children with a median age of 10.5 (interquartile range [IQR] 7-14.6) years were included. Of those, 7 were male (35%), and median time from onset to thrombectomy was 9.8 (IQR 7.8-16.2) hours. Neurologic outcome improved from a median Pediatric NIH Stroke Scale score of 12.0 (IQR 8.8-20.3) at admission to 2.0 (IQR 1.2-6.8) at day 7. Median modified Rankin Scale (mRS) score was 1.0 (IQR 0-1.6) at 3 months and 0.0 (IQR 0-1.0) at 24 months. One patient developed transient peri-interventional vasospasm; no other complications were observed. A comparison of the mRS score to the mRS score in the DAWN and DEFUSE 3 trials revealed a higher proportion of good outcomes in the pediatric compared to the adult study population. CONCLUSIONS: Thrombectomy in pediatric ischemic stroke in an extended time window of up to 24 hours after onset of symptoms seems safe and neurologic outcomes are generally good if patients are selected by a mismatch between clinical deficit and infarct. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that for children with acute ischemic stroke with a mismatch between clinical deficit and infarct size, thrombectomy is safe.


Assuntos
Embolectomia , AVC Isquêmico/cirurgia , Seleção de Pacientes , Trombectomia , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
13.
Int J Comput Assist Radiol Surg ; 15(9): 1525-1535, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32623613

RESUMO

PURPOSE: Medical case-based reasoning solves problems by applying experience gained from the outcome of previous treatments of the same kind. Particularly for complex treatment decisions, for example, incidentally found intracranial aneurysms (IAs), it can support the medical expert. IAs bear the risk of rupture and may lead to subarachnoidal hemorrhages. Treatment needs to be considered carefully, since it may entail unnecessary complications for IAs with low rupture risk. With a rupture risk prediction based on previous cases, the treatment decision can be supported. METHODS: We present an interactive visual exploration tool for the case-based reasoning of IAs. In presence of a new aneurysm of interest, our application provides visual analytics techniques to identify the most similar cases with respect to morphology. The clinical expert can obtain the treatment, including the treatment outcome, for these cases and transfer it to the aneurysm of interest. Our application comprises a heatmap visualization, an adapted scatterplot matrix and fully or partially directed graphs with a circle- or force-directed layout to guide the interactive selection process. To fit the demands of clinical applications, we further integrated an interactive identification of outlier cases as well as an interactive attribute selection for the similarity calculation. A questionnaire evaluation with six trained physicians was used. RESULT: Our application allows for case-based reasoning of IAs based on a reference data set. Three classifiers summarize the rupture state of the most similar cases. Medical experts positively evaluated the application. CONCLUSION: Our case-based reasoning application combined with visual analytic techniques allows for representation of similar IAs to support the clinician. The graphical representation was rated very useful and provides visual information of the similarity of the k most similar cases.


Assuntos
Diagnóstico por Computador/métodos , Hemodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Medição de Risco/métodos , Algoritmos , Gráficos por Computador , Bases de Dados Factuais , Tomada de Decisões , Humanos , Modelos Estatísticos , Inquéritos e Questionários , Interface Usuário-Computador
14.
Stroke ; 51(4): 1182-1189, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32114927

RESUMO

Background and Purpose- The recent Save ChildS study provides multicenter evidence for the use of mechanical thrombectomy in children with large vessel occlusion arterial ischemic stroke. However, device selection for thrombectomy may influence rates of recanalization, complications, and neurological outcomes, especially in pediatric patients of different ages. We, therefore, performed additional analyses of the Save ChildS data to investigate a possible association of different thrombectomy techniques and devices with angiographic and clinical outcome parameters. Methods- The Save ChildS cohort study (January 2000-December 2018) analyzed data from 27 European and United States stroke centers and included all pediatric patients (<18 years), diagnosed with arterial ischemic stroke who underwent endovascular recanalization. Patients were grouped into first-line contact aspiration (A Direct Aspiration First Pass Technique [ADAPT]) and non-ADAPT groups as well as different stent retriever size groups. Associations with baseline characteristics, recanalization rates (modified Treatment in Cerebral Infarction), complication rates, and neurological outcome parameters (Pediatric National Institutes of Health Stroke Scale after 24 hours and 7 days; modified Rankin Scale and Pediatric Stroke Outcome Measure at discharge, after 6 and 24 months) were investigated. Results- Seventy-three patients with a median age of 11.3 years were included. Currently available stent retrievers were used in 59 patients (80.8%), of which 4×20 mm (width×length) was the most frequently chosen size (36 patients =61%). A first-line ADAPT approach was used in 7 patients (9.6%), and 7 patients (9.6%) were treated with first-generation thrombectomy devices. In this study, a first-line ADAPT approach was neither associated with the rate of successful recanalization (ADAPT 85.7% versus 87.5% No ADAPT) nor with the complication rate or the neurological outcome. Moreover, there were no associations of stent retriever sizes with rates of recanalization, complication rates, or outcome parameters. Conclusions- Our study suggests that neurological outcomes are generally good regardless of any specific device selection and suggests that it is important to offer thrombectomy in eligible children regardless of technique or device selection. Registration- URL: https://www.drks.de/; Unique identifier: DRKS00016528.


Assuntos
Isquemia Encefálica/cirurgia , Revascularização Cerebral/instrumentação , Doenças do Sistema Nervoso/prevenção & controle , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia/instrumentação , Adolescente , Isquemia Encefálica/diagnóstico por imagem , Revascularização Cerebral/métodos , Criança , Pré-Escolar , Estudos de Coortes , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Lactente , Masculino , Doenças do Sistema Nervoso/diagnóstico por imagem , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/métodos , Resultado do Tratamento
15.
Sci Rep ; 10(1): 412, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31941911

RESUMO

Intracranial stents have expanded endovascular therapy options for intracranial aneurysms. The braided Accero stent is available for clinical use since May 2015. To date, no clinical reports on the stent are available. Purpose of this study was the evaluation of the safety and efficacy of the Accero stent in stent-assisted coiling. All patients, in whom implantation of the stent was performed, were included. Primary endpoints were good clinical outcome (mRS ≤ 2) and aneurysm occlusion grades 1 and 2 (Raymond Roy Occlusion Classification). Secondary endpoints were procedural and device-related complications with permanent disability or death, complications in the course, and the recanalization rate. Between September 2015 and August 2018, thirty-four aneurysms were treated with stent-assisted coiling using the Accero. Sixteen aneurysms were untreated, four of these were ruptured. Mild neurological complications occurred in 2/34 (5.9%) treatments. Two stent occlusions occurred during follow-up. No patient had a poor procedure- or device-related outcome. After an average of 15 months of follow-up, 28/30 aneurysms were completely or near-completely occluded. The Accero stent proved to be safe and effective in the treatment of broad-based intracranial aneurysms. The complication rate and the rate of successful aneurysm occlusions are similar to those of other stents.


Assuntos
Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/terapia , Stents , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
16.
Ther Adv Neurol Disord ; 13: 1756286420966159, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33403004

RESUMO

INTRODUCTION: A multitude of approaches have been postulated for assessing the risk of intracranial aneurysm rupture. However, the amount of potential predictive factors is not applicable in clinical practice and they are rejected in favor of the more practical PHASES score. For the subgroup of multiple intracranial aneurysms (MIAs), the PHASES score might severely underestimate the rupture risk, as only the aneurysm with the largest diameter is considered for risk evaluation. METHODS: In this study, we investigated 38 patients harboring a total number of 87 MIAs with respect to their morphological and hemodynamical characteristics. For the determination of the best suited parameters regarding their predictive power for aneurysm rupture, we conducted three phases of statistical evaluation. The statistical analysis aimed to identify parameters that differ significantly between ruptured and unruptured aneurysms, show smallest possible correlations among each other and have a high impact on rupture risk prediction. RESULTS: Significant differences between ruptured and unruptured aneurysms were found in 16 out of 49 parameters. The lowest correlation were found for gamma, aspect ratio (AR1), aneurysm maximal relative residence time (Aneurysm_RRT_max) and aneurysm mean relative residence time. The data-driven parameter selection yielded a significant correlation of only two parameters (AR1 and the Aneurysm_RRT_max) with rupture state (area under curve = 0.75). CONCLUSION: A high number of established morphological and hemodynamical parameters seem to have no or only low effect on prediction of aneurysm rupture in patients with MIAs. For best possible rupture risk assessment of patients with MIAs, only the morphological parameter AR1 and the hemodynamical parameter Aneurysm_RRT_max need to be included in the prediction model.

17.
JAMA Neurol ; 77(1): 25-34, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31609380

RESUMO

Importance: Randomized clinical trials have shown the efficacy of thrombectomy of large intracranial vessel occlusions in adults; however, any association of therapy with clinical outcomes in children is unknown. Objective: To evaluate the use of endovascular recanalization in pediatric patients with arterial ischemic stroke. Design, Setting, and Participants: This retrospective, multicenter cohort study, conducted from January 1, 2000, to December 31, 2018, analyzed the databases from 27 stroke centers in Europe and the United States. Included were all pediatric patients (<18 years) with ischemic stroke who underwent endovascular recanalization. Median follow-up time was 16 months. Exposures: Endovascular recanalization. Main Outcomes and Measures: The decrease of the Pediatric National Institutes of Health Stroke Scale (PedNIHSS) score from admission to day 7 was the primary outcome (score range: 0 [no deficit] to 34 [maximum deficit]). Secondary clinical outcomes included the modified Rankin scale (mRS) (score range: 0 [no deficit] to 6 [death]) at 6 and 24 months and rate of complications. Results: Seventy-three children from 27 participating stroke centers were included. Median age was 11.3 years (interquartile range [IQR], 7.0-15.0); 37 patients (51%) were boys, and 36 patients (49%) were girls. Sixty-three children (86%) received treatment for anterior circulation occlusion and 10 patients (14%) received treatment for posterior circulation occlusion; 16 patients (22%) received concomitant intravenous thrombolysis. Neurologic outcome improved from a median PedNIHSS score of 14.0 (IQR, 9.2-20.0) at admission to 4.0 (IQR, 2.0-7.3) at day 7. Median mRS score was 1.0 (IQR, 0-1.6) at 6 months and 1.0 (IQR, 0-1.0) at 24 months. One patient (1%) developed a postinterventional bleeding complication and 4 patients (5%) developed transient peri-interventional vasospasm. The proportion of symptomatic intracerebral hemorrhage events in the HERMES meta-analysis of trials with adults was 2.79 (95% CI, 0.42-6.66) and in Save ChildS was 1.37 (95% CI, 0.03-7.40). Conclusions and Relevance: The results of this study suggest that the safety profile of thrombectomy in childhood stroke does not differ from the safety profile in randomized clinical trials for adults; most of the treated children had favorable neurologic outcomes. This study may support clinicians' practice of off-label thrombectomy in childhood stroke in the absence of high-level evidence.


Assuntos
Procedimentos Endovasculares/métodos , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
18.
J Neurol Surg A Cent Eur Neurosurg ; 81(1): 80-85, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31466101

RESUMO

OBJECTIVE: Dural arteriovenous fistulas of the craniocervical junction are rare but the most dangerous of spinal fistulas. The concurrent brainstem edema has been attributed to increased pressure within the venous outflow of the brainstem and upper cord, but the differential diagnosis of brainstem edema is demanding. This report presents the details of clinical findings, magnetic resonance imaging (MRI) , surgical techniques, and follow-up of these fistulas. METHODS: Three cases with dural arteriovenous fistulas and edema of the brainstem and upper cord are described plus a review of the literature. Clinical presentation, radiologic findings, and a follow-up of outcomes are presented. RESULTS: All three cases with misleading diagnoses at the time of referral experienced variable degrees of tetraparesis with brainstem edema on MRI. Congested veins on MRI raised the suspicion of a vascular origin of the edema. The diagnosis was established with highly specific angiography with microcatheters identifying a feeder from the ascending pharyngeal artery in two cases and a tentorial feeder from the carotid artery in one case. The operation included temporary clipping of the fistula and neuromonitoring. Follow-up confirmed improvement of clinical signs and resolution of the brainstem edema on MRI. CONCLUSION: Edema of the brainstem and cervical cord may be caused by a dural arteriovenous fistula of the craniocervical junction. Surgical occlusion may be an efficient option for the complete resolution of radiologic and clinical symptoms.


Assuntos
Edema Encefálico/cirurgia , Tronco Encefálico/patologia , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Idoso , Angiografia , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/etiologia , Edema Encefálico/patologia , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/cirurgia , Malformações Vasculares do Sistema Nervoso Central/complicações , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Z Med Phys ; 30(1): 40-50, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31831207

RESUMO

PURPOSE: This work aims at the compensation of beam hardening artifacts by the means of an extended three-dimensional polychromatic statistical reconstruction to be applied for flat panel cone-beam CT. METHODS: We implemented this reconstruction technique as being introduced by Elbakri et al. (2002) [1] for a multi-GPU system, assuming the underlying object consists of several well-defined materials. Furthermore, we assume one voxel can only contain an overlap of at most two materials, depending on its density value. Given the X-ray spectrum, the procedure enables to reconstruct the energy-dependent attenuation values of the volume. RESULTS: We evaluated the method by using flat-panel cone-beam CT measurements of structures containing small metal objects and clinical head scan data. In comparison with the water-corrected filtered backprojection, as well as a maximum likelihood reconstruction with a consistency-based beam hardening correction, our method features clearly reduced beam hardening artifacts and a more accurate shape of metal objects. CONCLUSIONS: Our multi-GPU implementation of the polychromatic reconstruction, which does not require any image pre-segmentation, clearly outperforms the standard reconstructions of objects, with respect to beam hardening even in the presence of metal objects inside the volume. However, remaining artifacts, caused mainly by the limited dynamic range of the detector, may have to be addressed in future work.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Encéfalo/diagnóstico por imagem , Humanos
20.
Neuroradiology ; 61(11): 1319-1326, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31473786

RESUMO

PURPOSE: Flow diverter (FD) devices show severe shortening during deployment in dependency of the vessel geometry. Valid information regarding the geometry of the targeted vessel is therefore mandatory for correct device selection, and to avoid complications. But the geometry of diseased tortuous intracranial vessels cannot be measured accurately with standard methods. The goal of this study is to prove the accuracy of a novel virtual stenting method in prediction of the behavior of a FD in an individual vessel geometry. METHODS: We applied a virtual stenting method on angiographic 3D imaging data of the specific vasculature of patients, who underwent FD treatment. The planning tool analyzes the local vessel morphology and deploys the FD virtually. We measured in 18 cases the difference between simulated FD length and real FD length after treatment in a landmark-based registration of pre-/post-interventional 3D angiographic datasets. RESULTS: The mean value of length deviation of the virtual FD was 2.2 mm (SD ± 1.9 mm) equaling 9.5% (SD ± 8.2%). Underestimated cases present lower deviations compared with overestimated FDs. Flow diverter cases with a nominal device length of 20 mm had the highest prediction accuracy. CONCLUSION: The results suggest that the virtual stenting method used in this study is capable of predicting FD length with a clinically sufficient accuracy in advance and could therefore be a helpful tool in intervention planning. Imaging data of high quality are mandatory, while processing and manipulation of the FD during the intervention may impact the accuracy.


Assuntos
Aneurisma Intracraniano/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA