Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 46(12): 3327-3338, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32919812

RESUMO

Mechanical effects of microbubbles on tissues are central to many emerging ultrasound applications. Here, we investigated the acoustic radiation force a microbubble exerts on tissue at clinically relevant therapeutic ultrasound parameters. Individual microbubbles administered into a wall-less hydrogel channel (diameter: 25-100 µm, Young's modulus: 2-8.7 kPa) were exposed to an acoustic pulse (centre frequency: 1 MHz, pulse length: 10 ms, peak-rarefactional pressures: 0.6-1.0 MPa). Using high-speed microscopy, each microbubble was tracked as it pushed against the hydrogel wall. We found that a single microbubble can transiently deform a soft tissue-mimicking material by several micrometres, producing tissue loading-unloading curves that were similar to those produced using other indentation-based methods. Indentation depths were linked to gel stiffness. Using a mathematical model fitted to the deformation curves, we estimated the radiation force on each bubble (typically tens of nanonewtons) and the viscosity of the gels. These results provide insight into the forces exerted on tissues during ultrasound therapy and indicate a potential source of bio-effects.


Assuntos
Módulo de Elasticidade , Teste de Materiais , Microbolhas , Modelos Biológicos , Ultrassonografia , Acústica
2.
Artigo em Inglês | MEDLINE | ID: mdl-32746222

RESUMO

In therapeutic ultrasound using microbubbles, it is essential to drive the microbubbles into the correct type of activity and the correct location to produce the desired biological response. Although passive acoustic mapping (PAM) is capable of locating where microbubble activities are generated, it is well known that microbubbles rapidly move within the ultrasound beam. We propose a technique that can image microbubble movement by estimating their velocities within the focal volume. Microbubbles embedded within a wall-less channel of a tissue-mimicking material were sonicated using 1-MHz focused ultrasound. The acoustic emissions generated by the microbubbles were captured with a linear array (L7-4). PAM with robust Capon beamforming was used to localize the microbubble acoustic emissions. We spectrally analyzed the time trace of each position and isolated the higher harmonics. Microbubble velocity maps were constructed from the position-dependent Doppler shifts at different time points during sonication. Microbubbles moved primarily away from the transducer at velocities on the order of 1 m/s due to primary acoustic radiation forces, producing a time-dependent velocity distribution. We detected microbubble motion both away and toward the receiving array, revealing the influence of acoustic radiation forces and fluid motion due to the ultrasound exposure. High-speed optical images confirmed the acoustically measured microbubble velocities. Doppler PAM enables passive estimation of microbubble motion and may be useful in therapeutic applications, such as drug delivery across the blood-brain barrier, sonoporation, sonothrombolysis, and drug release.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microbolhas , Processamento de Sinais Assistido por Computador , Ultrassonografia Doppler/métodos , Algoritmos , Transdutores , Terapia por Ultrassom
3.
J Orthop Res ; 35(10): 2135-2144, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28079273

RESUMO

The incidence of congenital spine deformities, including congenital scoliosis, kyphosis, and lordosis, may be influenced by the in utero mechanical environment, and particularly by fetal movements at critical time-points. There is a limited understanding of the influence of fetal movements on spinal development, despite the fact that mechanical forces have been shown to play an essential role in skeletal development of the limb. This study investigates the effects of muscle forces on spinal curvature, vertebral segmentation, and vertebral shape by inducing rigid or flaccid paralysis in the embryonic chick. The critical time-points for the influence of fetal movements on spinal development were identified by varying the time of onset of paralysis. Prolonged rigid paralysis induced severe defects in the spine, including curvature abnormalities, posterior and anterior vertebral fusions, and altered vertebral shape, while flaccid paralysis did not affect spinal curvature or vertebral segmentation. Early rigid paralysis resulted in more severe abnormalities in the spine than later rigid paralysis. The findings of this study support the hypothesis that the timing and nature of fetal muscle activity are critical influences on the normal development of the spine, with implications for the understanding of congenital spine deformities. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2135-2144, 2017.


Assuntos
Movimento Fetal , Coluna Vertebral/embriologia , Animais , Embrião de Galinha , Paralisia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA