Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Contemp Dent Pract ; 25(1): 10-14, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514425

RESUMO

AIM: To describe a clinical case of ultrasound (US) used to evaluate, before, post-immediately, and after 4 months, the facial application of a volumizing and biostimulating substance. BACKGROUND: Detecting the behavior of injected filler materials with high-frequency US-guided application is the future of natural facial rejuvenation with more predictable and satisfactory results. TECHNIQUE: A patient indicated for orofacial harmonization (OFH) procedures through volumizing and biostimulating material application was invited to participate. The technique was performed by applying HArmonyCa™ (Allergan Aesthetics, Irvine, CA, USA) in the gonial, preauricular, and bilateral lateral zygomatic angle regions. The first evaluations used the US images before and after product application with a Logiq e® high-frequency US device (GE Healthcare, Chicago, IL, USA) with a probe/linear transducer of 18 MHz. About 4 months after the procedure, a new assessment with the same initial acquisition pattern was performed. The first evaluation showed normal-looking anatomical structures without the esthetic material. Immediately after the procedure and 4 months later, the assessments presented semi-permanent esthetic fillers as dispersed lobulated hyperechogenic areas with a cloud aspect. CONCLUSION: High-frequency US was efficient in the static evaluation of HArmonyCa™ behavior on the facial skin. CLINICAL SIGNIFICANCE: The US-guided application of injectable products in specific areas has minimal side effects and contributes to more predictable and satisfactory results. How to cite this article: Gouveia RSA, Tostes LLL, Bezerra FV, et al. High-frequency Ultrasound in the Assessment before and after Applying HArmonyCa™. J Contemp Dent Pract 2024;25(1):10-14.


Assuntos
Técnicas Cosméticas , Humanos , Bochecha , Estética Dentária , Face/diagnóstico por imagem , Injeções
2.
Dentomaxillofac Radiol ; 46(8): 20160475, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28555506

RESUMO

The aim of this study was to systematically review the literature about the capability of CBCT images to identify individuals with low bone mineral density (BMD). As the literature is scarce regarding this topic, the purpose of this systematic review is also to guide future research in this area. A detailed search was performed in five databases without restrictions of time or languages. Additionally, a grey literature search was conducted. The Quality Assessment Tool for Diagnostic Accuracy Studies-2 was applied to evaluate the methodological design of selected studies. With the inclusion of only six studies, the evidence is limited to endorse the use of CBCT assertively as a diagnostic tool for low BMD. All of the three studies that analyzed radiomorphometric indices found that the linear measurements of the mandibular inferior cortex were lower in osteoporotic individuals. CBCT-derived radiographic density vertebral and mandibular measurements were also capable for differentiating individuals with osteoporosis from individuals with normal BMD. The analysis of the cervical vertebrae showed high accuracy measurements. This systematic review indicates a scarcity of studies regarding the potential of CBCT for screening individuals with low BMD. However, the studies indicate that radiomorphometric indices and CBCT-derived radiographic density should be promising tools for differentiating individuals with osteoporosis from individuals with normal BMD.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico/métodos , Osteoporose/diagnóstico por imagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA