Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Am J Perinatol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698594

RESUMO

Point-of-care ultrasound (POCUS) has increasingly been used by neonatal providers in neonatal intensive care units in the United States. However, there is a lack of literature addressing the complexities of POCUS coding and billing practices in the United States. This article describes the coding terminology and billing process especially those relevant to neonatal POCUS. We elucidate considerations for neonatal POCUS billing framework and workflow integration. Directions on image storage and supporting documentation to facilitate efficient reimbursement, compliance with billing regulations, and appeal to insurance claim denial are discussed. KEY POINTS: · Code neonatal POCUS procedure precisely allows accurate reimbursement and reduced errors in billing.. · Document details to support medical necessity and reimbursement claims effectively.. · Adhere to regulations to avoid audits, denials, and ensure proper reimbursement..

2.
Am J Perinatol ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408479

RESUMO

OBJECTIVE: To investigate the association of congenital heart disease (CHD) with morbidity and mortality of very low birth weight (VLBW) infants. STUDY DESIGN: This matched case-control study included VLBW infants born at a single institution between 2001 and 2015. The primary outcome was mortality. Secondary outcomes included necrotizing enterocolitis, bronchopulmonary dysplasia (BPD), sepsis, retinopathy of prematurity, and intraventricular hemorrhage. These outcomes were assessed by comparing VLBW-CHDs with control VLBW infants matched by gestational age within a week, birth weight within 500 g, sex, and birth date within a year using conditional logistic regression. Multivariable logistic regression analyzed differences in outcomes in the VLBW-CHD group between two birth periods (2001-2008 and 2009-2015) to account for changes in practice. RESULTS: In a cohort of 44 CHD infants matched with 88 controls, the mortality rate was 27% in infants with CHD and 1% in controls (p < 0.0001). The VLBW-CHDs had increased BPD; (odds ratio [OR]: 7.70, 95% confidence interval [CI]: 1.96-30.29) and sepsis (OR: 10.59, 95% CI: 2.99-37.57) compared with the control VLBWs. When adjusted for preoperative ventilator use, the VLBW-CHDs still had significantly higher odds of BPD (OR: 6.97, 95% CI: 1.73-28.04). VLBW-CHDs also had significantly higher odds of both presumed and culture-positive sepsis as well as late-onset sepsis than their matched controls. There were no significant differences in outcomes between the two birth periods. CONCLUSION: VLBW-CHDs showed higher odds of BPD, sepsis, and mortality than VLBW infants without CHD. Future research should focus on the increased mortality and specific complications encountered by VLBW infants with CHD and implement targeted strategies to address these risks. KEY POINTS: · Incidence of CHD is higher in preterm infants than in term infants but the incidence of their morbidities is not well described.. · VLBW infants with CHD have higher odds of mortality, bronchopulmonary dysplasia, and sepsis.. · Future research is needed to implement targeted preventive responses..

3.
J Am Soc Echocardiogr ; 37(2): 171-215, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309835

RESUMO

Targeted neonatal echocardiography (TNE) involves the use of comprehensive echocardiography to appraise cardiovascular physiology and neonatal hemodynamics to enhance diagnostic and therapeutic precision in the neonatal intensive care unit. Since the last publication of guidelines for TNE in 2011, the field has matured through the development of formalized neonatal hemodynamics fellowships, clinical programs, and the expansion of scientific knowledge to further enhance clinical care. The most common indications for TNE include adjudication of hemodynamic significance of a patent ductus arteriosus, evaluation of acute and chronic pulmonary hypertension, evaluation of right and left ventricular systolic and/or diastolic function, and screening for pericardial effusions and/or malpositioned central catheters. Neonatal cardiac point-of-care ultrasound (cPOCUS) is a limited cardiovascular evaluation which may include line tip evaluation, identification of pericardial effusion and differentiation of hypovolemia from severe impairment in myocardial contractility in the hemodynamically unstable neonate. This document is the product of an American Society of Echocardiography task force composed of representatives from neonatology-hemodynamics, pediatric cardiology, pediatric cardiac sonography, and neonatology-cPOCUS. This document provides (1) guidance on the purpose and rationale for both TNE and cPOCUS, (2) an overview of the components of a standard TNE and cPOCUS evaluation, (3) disease and/or clinical scenario-based indications for TNE, (4) training and competency-based evaluative requirements for both TNE and cPOCUS, and (5) components of quality assurance. The writing group would like to acknowledge the contributions of Dr. Regan Giesinger who sadly passed during the final revisions phase of these guidelines. Her contributions to the field of neonatal hemodynamics were immense.


Assuntos
Unidades de Terapia Intensiva Neonatal , Neonatologia , Humanos , Recém-Nascido , Criança , Feminino , Estados Unidos , Sistemas Automatizados de Assistência Junto ao Leito , Ecocardiografia , Ultrassonografia , Hemodinâmica/fisiologia
4.
Eur J Pediatr ; 183(4): 1525-1541, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38236402

RESUMO

Cardiac point-of-care ultrasound (POCUS) is a technology increasingly leveraged at the bedside by pediatric critical care and neonatology providers to identify real-time hemodynamic pathophysiology. We present a framework for (1) identifying the scope of cardiac POCUS within the clinical practice setting, (2) standardizing views for protocolized hemodynamic assessment relevant to pediatric critical illness and (3) integrating POCUS findings for therapeutic guidance. Within the review, we also discuss practical strengths and limitations to image acquisition and interpretation within the varied cardiac POCUS views. Finally, we explore unique considerations within the neonatal population.    Conclusion: Cardiac POCUS is a technology and tool that reveals important real-time information at the bedside of the critically ill child and infant. Understanding strengths and limitations of cardiac POCUS views and protocolizing an approach to answer focused clinical questions provides a framework for training and translation to clinical care. What is Known: • Ultrasound technology is now ubiquitous among pediatric critical care and neonatology settings, and growing literature supports an expanded role in not only procedural but also diagnostic applications. • Cardiac POCUS influences provider perception of pathophysiology and changes clinical management. What is New: • Effective cardiac POCUS training and subsequent translation to clinical practice should improve when clinical questions and protocolized approaches to image acquisition are standardized within a specialty. • Cardiac POCUS views have strengths and limitations which must be recognized when assessing the hemodynamic profile of a child or neonate.


Assuntos
Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Recém-Nascido , Criança , Humanos , Ultrassonografia/métodos , Testes Imediatos , Cuidados Críticos/métodos , Estado Terminal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA