Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38814525

RESUMO

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

2.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
3.
Circ Arrhythm Electrophysiol ; 17(4): e012374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426305

RESUMO

BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Testes Genéticos , Arritmias Cardíacas/genética , Mutação de Sentido Incorreto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Mutação
4.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

5.
JACC Clin Electrophysiol ; 9(10): 2096-2105, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37565952

RESUMO

BACKGROUND: Patients with Brugada syndrome (BrS) have an increased risk of arrhythmias, including atrial tachyarrhythmias (ATas). OBJECTIVES: The purpose of this study was to assess underlying atrial cardiomyopathy in BrS and the effect of ajmaline (AJM) test on the atrium of BrS patients using electrocardiogram imaging (ECGI). METHODS: All consecutive patients diagnosed with BrS in a monocentric registry were screened and included if they met the following criteria: 1) BrS diagnosed following current recommendations; and 2) ECGI map performed before and after AJM with a standard protocol. Consecutive patients with no structural heart disease or BrS who had undergone ECGI were included as a control group. Genetic analysis for SCN5A was performed in all BrS patients. Total atrial conduction time (TACT) and local atrial conduction time (LACT) were calculated from atrial ECGI. The primary endpoint was ATas during follow-up. RESULTS: Forty-three consecutive BrS patients and 40 control patients were included. Both TACT and LACT were significantly prolonged in BrS patients compared with control patients. Furthermore, TACT and LACT were significantly higher after AJM administration and in BrS patients who were carriers of a pathogenic/likely pathogenic SCN5A variant. After a mean follow-up of 40.9 months, 6 patients experienced a first ATa occurrence (all in the BrS group, 13.9%). TACT was the only independent predictor of ATas with a cutoff of >138.5 ms (sensitivity 0.92 [95% CI: 0.83-0.98], specificity 0.70 [95% CI: 0.59-0.81]). CONCLUSIONS: ECGI-calculated TACT and LACT are significantly prolonged in BrS patients compared with control patients, and in BrS patients after AJM. This may be consistent with a concealed atrial cardiomyopathy in BrS.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Cardiomiopatias , Humanos , Síndrome de Brugada/diagnóstico por imagem , Síndrome de Brugada/genética , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia/métodos , Ajmalina
6.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1296-1306, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227348

RESUMO

BACKGROUND: Different genes have been associated with idiopathic ventricular fibrillation (IVF); however, there are no studies correlating genotype with phenotype. OBJECTIVES: The aim of this study was to define the genetic background of probands with IVF using large gene panel analysis and to correlate genetics with long-term clinical outcomes. METHODS: All consecutive probands with a diagnosis of IVF were included in a multicenter retrospective study. All patients had: 1) IVF diagnosis throughout the follow-up; and 2) genetic analysis with a broad gene panel. All genetic variants were classified as pathogenic/likely pathogenic (P+), variants of unknown significance (VUS) or no variants (NO-V), following current guidelines of the American College of Medical Genetics and Genomics and the Association for Molecular Pathology. The primary endpoint was occurrence of ventricular arrhythmias (VA). RESULTS: Forty-five consecutive patients were included. A variant was found in 12 patients, 3 P+ and 9 VUS carriers. After a mean follow-up time of 105.0 months, there were no deaths and 16 patients (35.6%) experienced a VA. NO-V patients had higher VA free survival during the follow-up, compared with both VUS (72.7% vs 55.6%, log-rank P < 0.001) and P+ (72.7% vs 0%, log-rank P = 0.013). At Cox analysis, P+ or VUS carrier status was a predictor of VA occurrence. CONCLUSIONS: In probands with IVF, undergoing genetic analysis with a broad panel, the diagnostic yield for P+ is 6.7%. P+ or VUS carrier status is a predictor of VA occurrence.


Assuntos
Testes Genéticos , Fibrilação Ventricular , Humanos , Estudos Retrospectivos , Arritmias Cardíacas/complicações
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
8.
J Interv Card Electrophysiol ; 66(9): 2135-2142, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37178190

RESUMO

BACKGROUND: The influence of divergent anesthesia types during ablation of premature ventricular complexes (PVCs) is not known. While previously performed under general anesthesia (GA) at our institution, these procedures were exclusively performed under local anesthesia (LA) ± minimal sedation during the COVID-19 outbreak for logistic reasons. METHODS: One hundred and eight consecutive patients (82 GA versus 26 LA) undergoing PVC ablation at our center were evaluated. Intraprocedural PVC burden (over 3 min) pre-ablation was measured twice: (1) at the start (before GA induction) and (2) before catheter insertion (after GA induction). Upon cessation of ablation and after a waiting period of ≥ 15 min, acute ablation success (AAS) was defined as absence of PVCs until the end of the recording period. RESULTS: Intraprocedural PVC burden was not significantly different between LA versus GA group: (1) 17.8 ± 3% vs 12.7 ± 2%, P = 0.17 and (2) 10.0 ± 3% vs 7.4 ± 1%, P = 0.43, respectively. Activation mapping-based ablation was performed significantly more in the LA vs GA group (77% vs 26% of patients, P < 0.001, respectively). AAS was significantly higher in LA vs GA group: 22/26 (85%) vs 41/82 (50%), respectively, P < 0.01. After multivariable analysis, LA was the only independent predictor for AAS (OR 13, 95% CI 1.57-107.4, P = 0.017). CONCLUSION: Ablation of PVC under LA presented significantly higher AAS rate compared to GA. The procedure under GA might be complicated by PVC inhibition (after catheter insertion/during mapping) and PVC disinhibition post-extubation.


Assuntos
Anestésicos , COVID-19 , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/métodos , Anestesia Local , Resultado do Tratamento
9.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37061847

RESUMO

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Assuntos
Síndrome de Brugada , Adulto , Humanos , Criança , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Testes Genéticos , Arritmias Cardíacas/genética , Cardioversão Elétrica , Prognóstico , Eletrocardiografia/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética
10.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
11.
Europace ; 25(3): 896-904, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36738245

RESUMO

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
12.
Clin Auton Res ; 33(1): 51-62, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36645559

RESUMO

PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.


Assuntos
Ajmalina , Síndrome de Brugada , Humanos , Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Frequência Cardíaca , Isoproterenol , Arritmias Cardíacas , Eletrocardiografia , Prognóstico
13.
Expert Rev Med Devices ; 20(1): 45-54, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36631432

RESUMO

BACKGROUND: Implantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of traumatic syncopal recurrence during ILR monitoring in this specific patient setting are lacking. RESEARCH DESIGN AND METHODS: Prospective, multicentre registry enrolling consecutive patients undergoing ILR insertion for unexplained, recurrent, traumatic syncope. In a proportion of enrolled patients, remote monitoring (RM) was used for device follow-up. The risk of traumatic and non-traumatic syncopal recurrences during ILR observation were prospectively assessed. RESULTS: A total of 483 consecutive patients (68±14 years, 59% male) were enrolled. During a median follow-up of 18 months, a final diagnosis was reached in 270 patients (55.9%). The risk of syncopal and traumatic syncopal recurrence was of 26.5 and 9.3%, respectively. RM significantly reduced the time to diagnosis (19.7±10.3 vs. 22.1±10.8 months; p=0.015) and was associated with a significant reduction in the risk of syncope recurrence of 48% (p<0.001), and of traumatic syncope recurrence of 49% (p=0.018). CONCLUSIONS: ILR monitoring is effective and safe in patients with unexplained, recurrent, traumatic syncope. RM reduces the time to diagnosis and significantly reduces the risk of traumatic and non-traumatic syncopal relapses.


Assuntos
Eletrocardiografia Ambulatorial , Síncope , Humanos , Masculino , Idoso , Feminino , Estudos Prospectivos , Eletrodos Implantados , Síncope/diagnóstico , Diagnóstico Diferencial
14.
Am J Cardiol ; 186: 236-242, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36328833

RESUMO

Recent studies suggested that early repolarization (ER)/J wave at the electrocardiogram (ECG) is associated with increased risk of sudden death and ventricular arrhythmias in patients with acute myocardial infarction. In this study, we prospectively assessed whether ER/J wave has any long-term prognostic implications in patients with stable ischemic heart disease (IHD). We enrolled consecutive clinically stable patients with documented IHD, referred to undergo a routine ECG. ER (typical concave ST-segment elevation) and J wave were diagnosed according to prospectively defined criteria. The final population included 617 patients with documented IHD (455 men; age 68.1 ± 11 years). ER/J wave was found in 138 patients (22.4%), 13 of whom (2.1%) showed ER and 133 (21.6%) a J wave. At a follow-up of 8.1±2.9 years, 160 deaths occurred (25.9%), 60 (9.7%) attributed to cardiovascular causes. Total mortality was lower in patients with versus those without ER/J wave (18.8% vs 28.0%; hazard ratio [HR] 0.61, 95% confidence interval [CI] 0.40 to 0.93, p = 0.02). The difference, however, was not significant after adjustment for confounding clinical variables (HR 0.78, 95% CI 0.51 to 1.19, p = 0.25). No significant difference was found in cardiovascular death between patients with (7.2%) and those without (10.4%) ER/J wave (adjusted HR 0.78, 95% CI 0.40 to 1.55, p = 0.48). Similar results were obtained for ER and J wave separately, and for ECG location of ER/J wave (inferior or lateral/precordial) and type of J wave (notched or slurred). The ER/J wave pattern at the ECG is not associated with increased risk of long-term mortality in clinically stable patients with a documented history of IHD.


Assuntos
Sistema de Condução Cardíaco , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Prognóstico , Eletrocardiografia , Arritmias Cardíacas/diagnóstico , Infarto do Miocárdio/diagnóstico
15.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
16.
Front Cardiovasc Med ; 9: 985182, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439999

RESUMO

Introduction: Unrecognized incomplete pulmonary vein (PV) isolation during the index procedure, can be a major cause of clinical recurrences of atrial fibrillation (AF) after cryoballoon (CB) ablation. We aimed to characterize the extension of the lesions produced by CB ablation and to assess the value of using an ultra-high resolution electroanatomic mapping (UHDM) system to detect incomplete CB lesions. Materials and methods: Twenty-nine consecutive patients from the CHARISMA registry undergoing AF ablation at four Italian centers were prospectively evaluated. The Rhythmia™ mapping system and the Orion™ (Boston Scientific) mapping catheter were used to systematically map the left atrium and PVs before and after cryoablation. Results: A total of 116 PVs were targeted and isolated. Quantitative assessment of the lesions revealed a significant reduction of the antral surface area of the PV, resulting in an ablated area of 5.7 ± 0.7 cm2 and 5.1 ± 0.8 cm2 for the left PV pair and right PV pair, respectively (p = 0.0068). The mean posterior wall (PW) area was 22.9 ± 2 cm2 and, following PV isolation, 44.8 ± 6% of the PW area was ablated. After CB ablation, complete isolation of each PV was documented by the POLARMap™ catheter in all patients. By contrast, confirmatory UHDM and the Lumipoint™ tool unveiled PV signals in 1 out of 114 of the PVs (0.9%). Over 30-day follow-up, no major procedure-related adverse events were reported. After a mean follow-up of 333 days, 89.7% of patients were free from arrhythmia recurrence. Conclusion: The lesion extension achieved by the new CB ablation system involved the PV antrum, with less than 50% of the PW remaining untouched. The new system, with short tip and circular mapping catheter, failed to achieve PV isolation in only 0.9% of all PVs treated. Clinical trial registration: [http://clinicaltrials.gov/], identifier [NCT03793998].

17.
J Cardiovasc Dev Dis ; 9(10)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36286276

RESUMO

Permanent pacemaker implantation (PPI) represents a frequent complication after transcatheter aortic valve implantation (TAVI) due to atrio-ventricular (AV) node injury. Predictors of early AV function recovery were investigated. We analyzed 50 consecutive patients (82 ± 6 years, 58% males, EuroSCORE: 7.8 ± 3.3%, STS mortality score: 5 ± 2.8%). Pacemaker interrogations within 4−6 weeks from PPI were performed to collect data on AV conduction. The most common indication of PPI was persistent third-degree (44%)/high-degree (20%) AV block/atrial fibrillation (AF) with slow ventricular conduction (16%) after TAVI. At follow-up, 13 patients (26%) recovered AV conduction (i.e., sinus rhythm with stable 1:1 AV conduction/AF with a mean ventricular response >50 bpm, associated with a long-term ventricular pacing percentage < 5%). At multivariate analysis, complete atrio-ventricular block independently predicted pacemaker dependency at follow-up (p = 0.019). Patients with persistent AV dysfunction showed a significant AV conduction time prolongation after TAVI (PR interval from 207 ± 50 to 230 ± 51, p = 0.02; QRS interval from 124 ± 23 to 147 ± 16, p < 0.01) compared to patients with recovery, in whom AV conduction parameters remained unchanged. Several patients receiving PPI after TAVI have recovery of AV conduction within a few weeks. Longer observation periods prior to PPI might be justified, and algorithms to minimize ventricular pacing should be utilized whenever possible.

19.
J Cardiovasc Dev Dis ; 9(9)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36135447

RESUMO

Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim of combining the advantages of a thoracoscopic surgical ablation (direct visualization of anatomical structures to be spared and the possibility to perform epicardial lesions) and endocardial ablation (possibility to check line block, confirm PVI, and possibility to perform cavotricuspid isthmus ablation). Patient selection is of utmost importance. In persistent and long-term persistent AF, hybrid AF ablation demonstrated promising results in terms of AF free survival. It has been associated with a relatively low complication rate if performed in centers with expertise in hybrid procedures and experience with both surgical and endocardial ablation. Different techniques have been described, with different approaches and lesion sets. The aim of this review is to provide a state-of-the-art overview of hybrid AF ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA