Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Cont Lens Anterior Eye ; : 102185, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38796331

RESUMO

With over a billion adults worldwide currently affected, presbyopia remains a ubiquitous, global problem. Despite over a century of study, the precise mechanism of ocular accommodation and presbyopia progression remains a topic of debate. Accordingly, this narrative review outlines the lenticular and extralenticular components of accommodation together with the impact of age on the accommodative apparatus, neural control of accommodation, models of accommodation, the impact of presbyopia on retinal image quality, and both historic and contemporary theories of presbyopia.

2.
Vision (Basel) ; 8(2)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38651443

RESUMO

The current understanding of clinical approaches and barriers in managing childhood myopia among Indian optometrists is limited. This research underscores the necessity and relevance of evidence-based practice guidelines by exploring their knowledge, attitude, and practice towards childhood myopia. A self-administered internet-based 26-item survey was circulated online among practicing optometrists in India. The questions assessed the demographics, knowledge, self-reported clinical practice behavior, barriers, source of information guiding their management, and extent of adult caregiver engagement for childhood myopia. Of 393 responses, a significant proportion of respondents (32.6-92.4%) were unaware of the ocular complications associated with high myopia, with less than half (46.5%) routinely performing ocular biometry in clinical practice. Despite the growing awareness of emerging myopia management options, the uptake remains generally poor, with single-vision distance full-correction spectacles (70.3%) being the most common mode of vision correction. Barriers to adopting optimal myopia care are medicolegal concerns, absence of clinical practice guidelines, and inadequate consultation time. Own clinical experience and original research articles were the primary sources of information supporting clinical practice. Most (>70%) respondents considered involving the adult caregiver in their child's clinical decision-making process. While practitioners' awareness and activity of newer myopia management strategies are improving, there is plenty of scope for its enhancement. The importance of evidence-based practice guidelines and continuing education on myopia control might help practitioners enhance their clinical decision-making skills.

3.
Optom Vis Sci ; 101(3): 164-172, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546758

RESUMO

SIGNIFICANCE: A snapshot intraocular pressure (IOP) is ineffective in identifying the IOP peak and fluctuation, especially during sleep. Because IOP variability plays a significant role in the progression of glaucoma, monitoring the IOP, especially during sleep, is essential to capture the dynamic nature of IOP. PURPOSE: We aimed to design an ocular pressure estimator (OPE) that can reliably and accurately measure the IOP noninvasively over closed-eyelid condition. METHODS: Ocular pressure estimator works on the principle that the external pressure applied by raising the IOP of the eyeball is transmitted through a compressible septum to the pressure sensor, thus recording the IOP. A fluid-filled pouch with a pressure sensor was placed over a rubber glove mimicking the eyelid (septum), covering the cornea of enucleated goat eyeballs. A pressure-controlled setup was connected to a goat cadaver eye, which was validated by a rebound tonometer. Cannulation of eyeballs through the lower limbus had the least difference from the control setup values documented using rebound tonometer, compared with cannulation through the optic nerve. Intraocular pressures ranging from 3 to 30 mmHg was induced, and the outputs recorded using OPE were amplified and recorded for 10 minutes (n = 10 eyes). We stratified the randomization of the number of times and the induced pressures. RESULTS: The measurements recorded were found to be linear when measured against an IOP range of 3 to 30 mmHg. The device has excellent reliability (intraclass correlation coefficient, 0.998). The repeatability coefficient and coefficient of variations were 4.24 (3.60 to 4.87) and 8.61% (7.33 to 9.90), respectively. The overall mean difference ± SD between induced IOP and the OPE was 0.22 ± 3.50 (95% confidence interval, -0.35 to 0.79) mmHg across all IOP ranges. CONCLUSIONS: Ocular pressure estimator offers a promising approach for reliably and accurately measuring IOP and its fluctuation noninvasively under a condition mimicking a closed eye.


Assuntos
Pressão Intraocular , Tonometria Ocular , Animais , Reprodutibilidade dos Testes , Pálpebras , Cabras
4.
Carbohydr Res ; 537: 109073, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38442682

RESUMO

Herein we report a chemical synthesis of a pentasaccharide thioglycoside repeating unit of Plesiomonas shigelloides Strain 302-73 (Serotype O1), as a chain extension unit. In our synthetic endeavor we encountered multiple aglycon transfer reactions during glycosylations. This problem was obviated by employing a PMP group as a transient protecting group.


Assuntos
Plesiomonas , Tioglicosídeos , Sorogrupo , Oligossacarídeos , Glicosilação
5.
Ophthalmic Physiol Opt ; 44(3): 641-671, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38404172

RESUMO

PURPOSE: With the introduction of ChatGPT, artificial intelligence (AI)-based large language models (LLMs) are rapidly becoming popular within the scientific community. They use natural language processing to generate human-like responses to queries. However, the application of LLMs and comparison of the abilities among different LLMs with their human counterparts in ophthalmic care remain under-reported. RECENT FINDINGS: Hitherto, studies in eye care have demonstrated the utility of ChatGPT in generating patient information, clinical diagnosis and passing ophthalmology question-based examinations, among others. LLMs' performance (median accuracy, %) is influenced by factors such as the iteration, prompts utilised and the domain. Human expert (86%) demonstrated the highest proficiency in disease diagnosis, while ChatGPT-4 outperformed others in ophthalmology examinations (75.9%), symptom triaging (98%) and providing information and answering questions (84.6%). LLMs exhibited superior performance in general ophthalmology but reduced accuracy in ophthalmic subspecialties. Although AI-based LLMs like ChatGPT are deemed more efficient than their human counterparts, these AIs are constrained by their nonspecific and outdated training, no access to current knowledge, generation of plausible-sounding 'fake' responses or hallucinations, inability to process images, lack of critical literature analysis and ethical and copyright issues. A comprehensive evaluation of recently published studies is crucial to deepen understanding of LLMs and the potential of these AI-based LLMs. SUMMARY: Ophthalmic care professionals should undertake a conservative approach when using AI, as human judgement remains essential for clinical decision-making and monitoring the accuracy of information. This review identified the ophthalmic applications and potential usages which need further exploration. With the advancement of LLMs, setting standards for benchmarking and promoting best practices is crucial. Potential clinical deployment requires the evaluation of these LLMs to move away from artificial settings, delve into clinical trials and determine their usefulness in the real world.


Assuntos
Inteligência Artificial , Oftalmologia , Humanos , Tomada de Decisão Clínica , Olho , Julgamento
6.
J Physiol Anthropol ; 43(1): 7, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297353

RESUMO

BACKGROUND: Myopia, commonly known as near-sightedness, has emerged as a global epidemic, impacting almost one in three individuals across the world. The increasing prevalence of myopia during early childhood has heightened the risk of developing high myopia and related sight-threatening eye conditions in adulthood. This surge in myopia rates, occurring within a relatively stable genetic framework, underscores the profound influence of environmental and lifestyle factors on this condition. In this comprehensive narrative review, we shed light on both established and potential environmental and lifestyle contributors that affect the development and progression of myopia. MAIN BODY: Epidemiological and interventional research has consistently revealed a compelling connection between increased outdoor time and a decreased risk of myopia in children. This protective effect may primarily be attributed to exposure to the characteristics of natural light (i.e., sunlight) and the release of retinal dopamine. Conversely, irrespective of outdoor time, excessive engagement in near work can further worsen the onset of myopia. While the exact mechanisms behind this exacerbation are not fully comprehended, it appears to involve shifts in relative peripheral refraction, the overstimulation of accommodation, or a complex interplay of these factors, leading to issues like retinal image defocus, blur, and chromatic aberration. Other potential factors like the spatial frequency of the visual environment, circadian rhythm, sleep, nutrition, smoking, socio-economic status, and education have debatable independent influences on myopia development. CONCLUSION: The environment exerts a significant influence on the development and progression of myopia. Improving the modifiable key environmental predictors like time spent outdoors and engagement in near work can prevent or slow the progression of myopia. The intricate connections between lifestyle and environmental factors often obscure research findings, making it challenging to disentangle their individual effects. This complexity underscores the necessity for prospective studies that employ objective assessments, such as quantifying light exposure and near work, among others. These studies are crucial for gaining a more comprehensive understanding of how various environmental factors can be modified to prevent or slow the progression of myopia.


Assuntos
Miopia , Pré-Escolar , Criança , Humanos , Estudos Prospectivos , Miopia/epidemiologia , Miopia/genética , Miopia/prevenção & controle , Refração Ocular , Acomodação Ocular , Ritmo Circadiano
8.
Ophthalmic Physiol Opt ; 43(6): 1562-1570, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37476960

RESUMO

PURPOSE: ChatGPT is an artificial intelligence language model, which uses natural language processing to simulate human conversation. It has seen a wide range of applications including healthcare education, research and clinical practice. This study evaluated the accuracy of ChatGPT in providing accurate and quality information to answer questions on myopia. METHODS: A series of 11 questions (nine categories of general summary, cause, symptom, onset, prevention, complication, natural history, treatment and prognosis) were generated for this cross-sectional study. Each question was entered five times into fresh ChatGPT sessions (free from influence of prior questions). The responses were evaluated by a five-member team of optometry teaching and research staff. The evaluators individually rated the accuracy and quality of responses on a Likert scale, where a higher score indicated greater quality of information (1: very poor; 2: poor; 3: acceptable; 4: good; 5: very good). Median scores for each question were estimated and compared between evaluators. Agreement between the five evaluators and the reliability statistics of the questions were estimated. RESULTS: Of the 11 questions on myopia, ChatGPT provided good quality information (median scores: 4.0) for 10 questions and acceptable responses (median scores: 3.0) for one question. Out of 275 responses in total, 66 (24%) were rated very good, 134 (49%) were rated good, whereas 60 (22%) were rated acceptable, 10 (3.6%) were rated poor and 5 (1.8%) were rated very poor. Cronbach's α of 0.807 indicated good level of agreement between test items. Evaluators' ratings demonstrated 'slight agreement' (Fleiss's κ, 0.005) with a significant difference in scoring among the evaluators (Kruskal-Wallis test, p < 0.001). CONCLUSION: Overall, ChatGPT generated good quality information to answer questions on myopia. Although ChatGPT shows great potential in rapidly providing information on myopia, the presence of inaccurate responses demonstrates that further evaluation and awareness concerning its limitations are crucial to avoid potential misinterpretation.

9.
Indian J Ophthalmol ; 71(6): 2409-2415, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37322650

RESUMO

Purpose: Indian fishermen belong to a marginalized population and are continuously exposed to extreme occupational hazards and sunlight. A high prevalence of visual impairment (VI) is reported in the coastal fishing community. We aimed to investigate the association between VI and sunlight exposure measurement (SEM). Methods: In this cross-sectional observational study, 270 eyes of 135 participants were enrolled from a coastal fishing village. Participants underwent a comprehensive ophthalmic examination, which included best-corrected visual acuity (BCVA), and anterior and posterior segment examination. Ocular Surface Disease Index (OSDI) and SEM questionnaire were administered to estimate the level of dry eye and ultraviolet-B (UV-B) exposure, respectively. VI was defined as presenting visual acuity worse than 6/12 (logarithm of the minimum angle of resolution [logMAR] > 0.3). Results: The mean age and spherical equivalent were 50.56 ± 11.72 years (range: 18-80 years) and 0.36 ± 1.68 diopters (D) (range: -7.0 to +3.0 D), respectively. Age, SEM, OSDI, fishing as an occupation, and cataract were significantly associated with higher odds of VI in univariate analysis. Refraction, gender, education level, smoking status, amblyopia, systematic, and other ocular diseases were not significantly associated with VI. In the multivariate analysis, age, SEM, and presence of cataract remained significantly associated with a higher risk for VI. The area under the receiver operating characteristic curve values for age and SEM scores demonstrate a fair index of discrimination for the detection of VI. Conclusion: SEM level is directly associated with a higher risk of VI among fishermen. The fishing community might benefit from regular eye examinations and awareness about the harmful effects of sunlight exposure and preventive measures.


Assuntos
Catarata , Síndromes do Olho Seco , Baixa Visão , Humanos , Estudos Transversais , Luz Solar/efeitos adversos , Caça , Prevalência , Transtornos da Visão/diagnóstico , Transtornos da Visão/epidemiologia
12.
Invest Ophthalmol Vis Sci ; 64(3): 31, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951855

RESUMO

Purpose: To evaluate the duration-dependent and synergetic impact of high-intensity light (HL) and unrestricted vision (UnV) on lens-induced myopia (LIM) development in chickens. Methods: Myopia was induced in one eye in chicks (10 groups, n = 126) from day 1 posthatching (D1) until day 8 (D8) using -10 diopter (D) lenses. Fellow eyes remained uncovered as controls. Nine groups were exposed daily to 2, 4, or 6 hours of HL (15,000 lux), UnV (removal of -10 D lens), or both (HL + UnV). One group served as the LIM group without any interventions. Ocular axial length (AL), refractive error, and choroidal thickness were measured on D1, D4, and D8. Outcome measures are expressed as interocular difference (IOD = experimental eye - control eye) ± SEM. Results: By D8, LIM increased AL (0.36 ± 0.04 mm), myopic refraction (-9.02 ± 0.37 D), and choroidal thinning (-90.27 ± 16.44 µm) in the LIM group (all, P < 0.001). Compared to the LIM group, exposure to 2, 4, or 6 hours of HL, UnV, or HL + UnV reduced myopic refraction in a duration-dependent manner, with UnV being more effective than HL (P < 0.05). Only 6 hours of HL + UnV (not 2 or 4 hours) prevented LIM and was more effective than UnV (P = 0.004) or HL (P < 0.001) in reducing myopic refraction and more effective than HL (P < 0.001) in reducing axial elongation. Conclusions: Daily exposure to 2, 4, or 6 hours of HL, UnV, or HL + UnV reduced lens-induced myopic refraction in a duration-dependent manner in chickens. Only 6 hours of HL + UnV completely stopped LIM development. The synergetic effect of HL and UnV is dependent on the duration of the interventions.


Assuntos
Galinhas , Miopia , Animais , Animais Recém-Nascidos , Miopia/prevenção & controle , Olho , Visão Ocular , Refração Ocular , Corioide , Modelos Animais de Doenças
13.
Optom Vis Sci ; 100(1): 96-104, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36705719

RESUMO

SIGNIFICANCE: Relationship between intraocular pressure (IOP) change and central corneal curvature is complicated by measurement techniques and corneal biomechanical parameters. Findings from this study indicate that it is worthwhile to observe the association between diurnal change in IOP and corneal power. PURPOSE: This study aimed to investigate the relationship between the diurnal change in IOP and central corneal power among eyes with and without myopia. METHODS: Sixty healthy eyes of 24 emmetropes and 36 myopes were recruited for this cross-sectional study. Both anterior and posterior central corneal powers of the steep (Ks), flat (Kf), mean meridian (Km), best-fit spheres, and central corneal thickness were recorded followed by the IOP (Goldmann-correlated IOP [IOPg] and corneal-compensated IOP) and corneal biomechanics (corneal hysteresis and corneal resistance factor). Measurements were obtained every 3 hours from 9.30 am to 6.30 pm . Linear-mixed model was used to determine the relationship between the change in IOP and the associated change in corneal measurements (adjusted for age, sex, refractive error, central corneal thickness, and biomechanics) among the myopic and nonmyopic eyes. RESULTS: Group mean, amplitude of change, and the diurnal change in IOPg were (mean ± standard deviation) 15.14 ± 2.50, 3.33 ± 1.44, and 1.81 ± 1.25 mmHg, respectively. Overall, an IOP increase was associated with a decrease in the adjusted anterior corneal powers. Myopic eyes were associated with a decrease of 0.04 D (95% confidence interval [CI], 0.07 to 0.01 D; P = .02) in Ks and 0.03 D (95% CI, 0.06 to 0.001 D; P = .047) in Kf per mmHg increase in IOP, whereas for emmetropes, per mmHg increase in IOP only flattened the Kf by 0.03 D (95% CI, 0.06 to 0.004 D; P = .02). CONCLUSIONS: Change in anterior corneal power was inversely related to the change in IOPg, with myopic and nonmyopic eyes reporting a significant but differential impact of IOP. Clinicians must keep in mind the impact of large IOP fluctuation on the anterior corneal power.


Assuntos
Miopia , Erros de Refração , Humanos , Pressão Intraocular , Estudos Transversais , Córnea , Tonometria Ocular/métodos , Fenômenos Biomecânicos
14.
Bioconjug Chem ; 33(11): 2143-2148, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36345049

RESUMO

Synthetic calcium transporters are few despite their potential biological significance. Herein, we report small alanine-derived peptides containing pyridyl-triazole motifs for inducing calcium selectivity. The peptides are decorated with hydrophobic alkyl chains to facilitate membrane insertion. The most efficient peptide scaffold has an EC50 value of 0.09 mol % and functions as a calcium carrier.


Assuntos
Cálcio , Peptídeos , Ionóforos , Cálcio/metabolismo , Peptídeos/química , Transporte Biológico , Transporte de Íons
15.
Indian J Ophthalmol ; 70(3): 728-739, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35225506

RESUMO

Myopia has reached epidemic levels in recent years. Stopping the development and progression of myopia is critical, as high myopia is a major cause of blindness worldwide. This overview aims at finding the association of time spent outdoors (TSO), near work (NW), and physical activity (PA) with the incidence, prevalence, and progression of myopia in children. Literature search was conducted in PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature, Cochrane Database of Systematic Reviews, ProQuest, and Web of Science databases. Systematic reviews (SR) and meta-analyses (MA) on the TSO, NW, and PA in relation to myopia were reviewed. Methodological nature of qualified studies were evaluated utilizing the Risk of Bias in Systematic Review tool. We identified four SRs out of which three had MA, which included 62 unique studies, involving >1,00,000 children. This overview found a protective trend toward TSO with a pooled odds ratio (OR) of 0.982 (95% confidence interval (CI) 0.979-0.985, I2 = 93.5%, P < 0.001) per extra hour of TSO every week. A pooled OR 1.14 (95% CI 1.08-1.20) suggested NW to be related to risk of myopia. However, studies associating myopia with NW activities are not necessarily a causality as the effect of myopia might force children to indoor confinement with more NW and less TSO. PA presented no effect on myopia. Though the strength of evidence is less because of high heterogeneity and lack of clinical trials with clear definition, increased TSO and reduced NW are protective against myopia development among nonmyopes.


Assuntos
Exercício Físico , Miopia , Criança , Humanos , Incidência , Metanálise como Assunto , Miopia/epidemiologia , Prevalência , Revisões Sistemáticas como Assunto , Caminhada
16.
Optom Vis Sci ; 98(10): 1196-1202, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34620779

RESUMO

SIGNIFICANCE: Corneal refractive surgery screening, orthokeratology, and contact lens fitting require accurate estimation of the corneal thickness and curvature. We found that any of the imaging devices used in this study can be used to image a healthy myopic cornea, which is essential to screen for corneal ectasia. PURPOSE: This study aimed to compare agreement and repeatability of corneal thickness and radius measurements obtained using Scheimpflug imaging (Pentacam HR), swept-source optical coherence tomography (Casia SS-1000), and Placido-Scheimpflug tomography (Topographic Modeling System, version 5 [TMS-5]). METHODS: Sixty eyes of 60 subjects with myopia were measured with Casia, TMS-5, and Pentacam for their central corneal thickness (CCT), thinnest corneal thickness, central corneal radius of the steep meridian (Ks), central corneal radius of the flat meridian (Kf), mean central corneal radius (Km), and anterior and posterior best-fit spheres. Two readings were obtained from each instrument. Central corneal thickness was also measured with ultrasound pachymetry. Intraclass correlation coefficient, repeatability coefficient, and coefficient of variation were calculated. RESULTS: Repeatability coefficient, coefficient of variation, and intraclass correlation coefficient of CCT among the instruments ranged between 2.48 and 12.79, 0.17 and 0.86, and 0.98 and 1.00, respectively. Mean CCT measurements were similar between Casia, TMS-5, Pentacam, and ultrasound pachymetry (P = .13). Intraclass range of correlation for agreement was 0.95 to 0.99 for CCT among instruments. The range of 95% limits of agreement (LoAs) for ultrasound CCT was narrowest with Casia (31.94 µm). Casia-TMS-5 displayed a narrow range of 95% LoA for CCT (12.14 to -12.44), thinnest corneal thickness (12.31 to -11.31), and Ks (0.56 to -0.53), whereas Casia-Pentacam showed a narrow range of 95% LoA for Kf (0.56 to -0.42), Km (0.41 to -0.27), and anterior best-fit sphere (0.03 to -0.07). A significant difference in posterior best-fit sphere measurements was noted among all instruments (P = .01). CONCLUSIONS: Casia, TMS-5, and Pentacam can be used interchangeably to measure corneal thickness and radius measurement in healthy eyes. Casia had the best agreement with ultrasound pachymeter CCT and exhibited the highest repeatability.


Assuntos
Córnea , Rádio (Anatomia) , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea , Humanos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
17.
Org Lett ; 23(15): 6137-6142, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-34291950

RESUMO

First total synthesis of the conjugation-ready pentasaccharide repeating unit of Plesiomonas shigelloides strain 302-73 (serotype O1) is reported. The complex target pentasaccharide is composed of all-rare amino sugars such as orthogonally functionalized d-bacillosamine, l-fucosamine, and l-pneumosamine linked through four consecutive α-linkages. The poor nucleophilicity of axial 4-OH of l-fucosamine and stereoselective glycosylations are the key challenges in the total synthesis, which was completed via a longest linear sequence of 27 steps in 3% overall yield.


Assuntos
Amino Açúcares/síntese química , Oligossacarídeos/síntese química , Plesiomonas/química , Amino Açúcares/química , Estrutura Molecular , Oligossacarídeos/química , Sorogrupo
18.
Ther Adv Ophthalmol ; 13: 25158414211059246, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34988370

RESUMO

Myopia is far beyond its inconvenience and represents a true, highly prevalent, sight-threatening ocular condition, especially in Asia. Without adequate interventions, the current epidemic of myopia is projected to affect 50% of the world population by 2050, becoming the leading cause of irreversible blindness. Although blurred vision, the predominant symptom of myopia, can be improved by contact lenses, glasses or refractive surgery, corrected myopia, particularly high myopia, still carries the risk of secondary blinding complications such as glaucoma, myopic maculopathy and retinal detachment, prompting the need for prevention. Epidemiological studies have reported an association between outdoor time and myopia prevention in children. The protective effect of time spent outdoors could be due to the unique characteristics (intensity, spectral distribution, temporal pattern, etc.) of sunlight that are lacking in artificial lighting. Concomitantly, studies in animal models have highlighted the efficacy of light and its components in delaying or even stopping the development of myopia and endeavoured to elucidate possible mechanisms involved in this process. In this narrative review, we (1) summarize the current knowledge concerning light modulation of ocular growth and refractive error development based on studies in human and animal models, (2) summarize potential neurobiological mechanisms involved in the effects of light on ocular growth and emmetropization and (3) highlight a potential pathway for the translational development of noninvasive light-therapy strategies for myopia prevention in children.

19.
Indian J Ophthalmol ; 68(10): 2122-2125, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32971622

RESUMO

PURPOSE: To find the agreement and repeatability of Icare ic100 tonometer. METHODS: We included 150 subjects above the age of 18 years for this cross-sectional, multicenter study with intraocular pressure (IOP) ≥7 mmHg. After the initial ophthalmic examination, two masked examiners took five IOP measurements using three different instruments; Icare ic100, Icare TA01i, and Goldmann applanation tonometer (GAT) in only one eye of the participants. Comparison of agreement of IOP using different instruments was quantified with intraclass correlation coefficient (ICC) using the two-way random effects models of absolute agreement and Cronbach's alpha. The test-retest variability of the instruments was assessed by deriving repeatability coefficient (RC) and coefficient of variation (CV). RESULTS: Agreement between the tonometers across the different IOP groups had no statistically significant difference in their mean IOP. Icare ic100 was found to have good reliability across all IOP groups (ICC value >0.78) when compared with Icare TA01i. In comparison with GAT, Icare ic100 showed good reliability across all IOP groups (ICC >0.87) except >16 to <23 mmHg group where it showed moderate reliability (ICC = 0.52). Icare ic100 showed good repeatability with RC and CV of 2.67 and 4.89, respectively. CONCLUSION: Icare ic100 rebound tonometer can measure IOP with relatively small measurement error and can provide a reliable and repeatable reading in comparison with GAT across a wide pressure range without hampering corneal health.


Assuntos
Hipertensão Ocular , Tonometria Ocular , Adolescente , Estudos Transversais , Humanos , Pressão Intraocular , Reprodutibilidade dos Testes
20.
J Curr Ophthalmol ; 32(3): 268-273, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32775802

RESUMO

PURPOSE: To evaluate the performance of Plusoptix A09 in detecting ametropia, warranted against frequently-used technique of retinoscopy in children attending school (5-15 years) and its probability as a screening tool. METHODS: This study was the subset of a larger epidemiological study visual acuity refractive error squint conducted in schools to determine the prevalence of ocular morbidity among the 5-15 years' school children population. Every 7th student in the class (each school had mean value of 100 students) was randomly selected for this study after ascertaining their eligibility as per the inclusion criteria. A cohort of a total of 150 children within the age group of 5-15 (mean, 10.21 ± 2.83) years were recruited from 11 schools of Udupi district. Students with best corrected visual acuity of 20/20, refractive error within ±5.00 diopter (D), without any eccentric fixation, and no history of ocular pathology or seizures were recruited. Refractive error was tested by Plusoptix photorefractor followed by non-cycloplegic and cycloplegic retinoscopic techniques. The examiners performing these tests were masked and unware of the findings. Bland Altman plotted the agreement between the techniques, followed by the receiver operating characteristic curve (ROC), and sensitivity of Plusoptix. RESULTS: One-way analysis of variance calculated statistical differences among Plusoptix, objective retinoscopy, and cycloplegic retinoscopy for mean spherical value (1.12 ± 1.16 D, 0.65 ± 0.69 D, and 0.8 ± 0.82 D), cylindrical value (-0.83 D ± 1.27, -0.32 D ± 0.86, and -0.34 D ± -0.93), and spherical equivalent value (0.71 D ± 1.06, 0.45 D ± 0.7, and 0.61 D ± 0.81), with P = 0.0001, 0.0001, and 0.097, respectively. Bland Altman plots showed good agreement for spherical equivalent values of Plusoptix and objective retinoscopy. However, the area under the ROC curve (0.386) suggests that lower diagnostic ability of this device in this age group population in comparison to retinoscopy (0.575) with the sensitivity and specificity of Plusoptix was 69.2% and 84.8%. CONCLUSIONS: This study fails to report ideal sensitivity mandated for a screening tool, although good specificity and agreement are observed. Along with retinoscopy, this tool will be effective in screening a children's population aged between the age group of 5 and 15 years.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA