Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Heart Rhythm ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432424

RESUMO

BACKGROUND: Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE: The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS: Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS: Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION: P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.

3.
Clin Res Cardiol ; 113(1): 138-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37750991

RESUMO

BACKGROUND: While pulmonary hypertension (PH) in patients with severe aortic valve stenosis (AS) is associated with increased mortality after transcatheter aortic valve replacement (TAVR), there is limited data on gender differences in the effects on long-term survival. OBJECTIVE: The aim of this retrospective, multicenter study was to investigate the prognostic impact of pre-interventional PH on survival of TAVR patients with respect to gender. METHODS: 303 patients undergoing TAVR underwent echocardiography to detect PH prior to TAVR via measurement of systolic pulmonary artery pressure (sPAP). Different cut-off values were set for the presence of PH. The primary endpoint was all-cause mortality at 1, 3 and 5 years. RESULTS: Kaplan-Meier analysis by gender showed that only males exhibited significant increased mortality at elevated sPAP values during the entire follow-up period of 5 years (sPAP ≥ 40 mmHg: p ≤ 0.001 and sPAP ≥ 50 mmHg: p ≤ 0.001 in 1- to 5-year survival), whereas high sPAP values had no effect on survival in females. In Cox regression analysis based on the selected sPAP thresholds, male gender was an independent risk factor for long-term mortality after TAVR in all time courses. CONCLUSION: Male gender was an isolated risk factor for premature death after TAVR in patients with echocardiographic evidence of PH and severe AS. This could mean that, the indication for TAVR should be discussed more critically in men with severe AS and an elevated sPAP, while in females, PH should not be an exclusion criterion for TAVR.


Assuntos
Estenose da Valva Aórtica , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Artéria Pulmonar , Resultado do Tratamento , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Valva Aórtica/cirurgia
4.
Herzschrittmacherther Elektrophysiol ; 34(4): 272-277, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37870606

RESUMO

The two currently available leadless pacemakers are highly effective and safe in the respective approval studies and also real-world registries. Compared to conventional pacemakers, there are lower long-term complication rates compared to conventional pacemaker systems (especially regarding lead dislocations and systemic infections). Increasing evidence (currently largely for the Micra™ [Medtronic, Minneapolis, MN, USA] device) shows that these advantages are also valid in the long-term. Leadless pacemakers can therefore be regarded a "permanently good solution", when appropriately implanted in suitable patients.


Assuntos
Marca-Passo Artificial , Humanos , Desenho de Equipamento , Próteses e Implantes
5.
Sensors (Basel) ; 23(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37420719

RESUMO

Models of the human body representing digital twins of patients have attracted increasing interest in clinical research for the delivery of personalized diagnoses and treatments to patients. For example, noninvasive cardiac imaging models are used to localize the origin of cardiac arrhythmias and myocardial infarctions. The precise knowledge of a few hundred electrocardiogram (ECG) electrode positions is essential for their diagnostic value. Smaller positional errors are obtained when extracting the sensor positions, along with the anatomical information, for example, from X-ray Computed Tomography (CT) slices. Alternatively, the amount of ionizing radiation the patient is exposed to can be reduced by manually pointing a magnetic digitizer probe one by one to each sensor. An experienced user requires at least 15 min. to perform a precise measurement. Therefore, a 3D depth-sensing camera system was developed that can be operated under adverse lighting conditions and limited space, as encountered in clinical settings. The camera was used to record the positions of 67 electrodes attached to a patient's chest. These deviate, on average, by 2.0 mm ±1.5 mm from manually placed markers on the individual 3D views. This demonstrates that the system provides reasonable positional precision even when operated within clinical environments.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Humanos , Eletrodos , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia/métodos , Imageamento Tridimensional/métodos
6.
Front Cardiovasc Med ; 10: 1185518, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37265566

RESUMO

Introduction: The extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing). Methods: Patients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized. Results: In this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group. Discussion: In our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction.ClinicalTrials.gov identifier (NCT number): NCT04068233.

7.
Clin Res Cardiol ; 112(10): 1394-1416, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36935421

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) offers a measurement method for the determination of pulmonary hypertension (PH) in patients with severe aortic valve stenosis (AS) with determination of maximal tricuspid regurgitation velocity (TRVmax) and systolic pulmonary artery pressure (sPAP). Radiological parameters for noninvasive detection of PH, most importantly computed tomography (CT) based PA/AA-ratio = ratio of pulmonary artery diameter (PA) and ascending aorta diameter (AA), are also included in the latest ESC guidelines. The aim of the present study was to define cut-off values for PA/AA-ratio taking also into account cardiovascular biomarkers to determine criteria for noninvasive diagnosis of PH. METHODS: 194 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) underwent pre-procedural TTE and CT with measurement of PA/AA-ratio. Additionally, common cardiovascular biomarkers were determined. RESULTS: TAVR patients with an sPAP ≥ 40 mmHg or a TRVmax ≥ 2.9 m/s had a PA/AA-ratio ≥ 0.80 in an AUROC analysis. The cut-off value of ≥ 0.80 resulted in a significantly higher mortality rate (log-rank test: p = 0.034) in these patients in a Kaplan-Meier analysis regarding 1-year survival after TAVR. Significant differences in biomarker expression between patients with a PA/AA-ratio ≥ 0.80 or < 0.80 occurred for BNP (p = 0.001), cTnI (p = 0.032), GDF-15 (p = 0.002) and H-FABP (p = 0.015). CONCLUSION: PA/AA-ratio ≥ 0.80 is a promising radiological parameter that can provide information about mortality in patients with severe AS undergoing TAVR; combined with biomarkers it may contribute to noninvasive detection of PH in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/diagnóstico por imagem , Aorta Torácica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada por Raios X , Biomarcadores , Valva Aórtica/cirurgia , Resultado do Tratamento , Índice de Gravidade de Doença , Fatores de Risco
8.
Diagnostics (Basel) ; 13(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36766463

RESUMO

Both relevant aortic valve stenosis (AS) and aortic valve insufficiency significantly contribute to structural changes in the ascending aorta (AA) and thus to its dilatation. In patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), survival data regarding aortic changes and laboratory biomarker analyses are scarce. METHODS: A total of 179 patients with severe AS and an available computed tomography were included in this retrospective study. AA was measured, and dilatation was defined as a diameter ≥ 40 mm. Thirty-two patients had dilatation of the AA. A further 32 patients from the present population with a normal AA were matched to the aortic dilatation group with respect to gender, age, body mass index and body surface area, and the resulting study groups were compared with each other. In addition to echocardiographic and clinical characteristics, the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR) was analyzed. Kaplan-Meier curves for short- and long-term survival were obtained, and Pearson's and Spearman's correlations were calculated to identify the predictors between the diameter of the AA and clinical parameters. RESULTS: A total of 19% of the total cohort had dilatation of the AA. The study group with an AA diameter ≥ 40 mm showed a significantly low comorbidity with respect to diabetes mellitus in contrast to the comparison cohort with an AA diameter < 40 mm (p = 0.010). This result continued in the correlation analyses performed, as the presence of diabetes mellitus correlated negatively not only with the diameter of the AA (r = -0.404; p = 0.001) but also with the presence of aortic dilatation (r = -0.320; p = 0.010). In addition, the presence of AA dilatation after TAVR was shown to have no differences in terms of patient survival at 1, 3 and 5 years. There were no relevant differences in the cardiovascular biomarkers studied between the patients with dilated and normal AAs. CONCLUSION: The presence of AA dilatation before successful TAVR was not associated with a survival disadvantage at the respective follow-up intervals of 1, 3 and 5 years. Diabetes mellitus in general seemed to have a protective effect against the development of AA dilatation or aneurysm in patients with severe AS.

9.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36661917

RESUMO

(1) Background: Currently, echocardiography is the primary non-invasive diagnostic method used to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). Other radiological methods have been a focus of research in the past couple of years, as it was shown that by determining the pulmonary artery (PA) diameter, prognostic statements concerning overall mortality could be made in these patients. This study compared established and novel cardiovascular biomarkers with the PA/BSA value to detect PH in patients with severe AS. (2) Methods: The study cohort comprised 188 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), who were then divided into two groups based on PA/BSA values obtained through CT-angiography. The presence of PH was defined as a PA/BSA ≥ 16.6 mm/m2 (n = 81), and absence as a PA/BSA < 16.6 mm/m2 (n = 107). Blood samples were taken before TAVR to assess cardiovascular biomarkers used in this study, namely brain natriuretic peptide (BNP), cardiac troponin I (cTnI), high-sensitive troponin (hsTN), soluble suppression of tumorigenesis-2 (sST2), growth/differentiation factor 15 (GDF-15), heart-type fatty acid-binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2), and soluble urokinase-type plasminogen activator receptor (suPAR). (3) Results: Patients with a PA/BSA ≥ 16.6 mm/m2 showed significantly higher levels of BNP (p = <0.001), GDF-15 (p = 0.040), and H-FABP (p = 0.007). The other investigated cardiovascular biomarkers did not significantly differ between the two groups. To predict a PA/BSA ≥ 16.6 mm/m2, cut-off values for the biomarkers were calculated. Here, GDF-15 (p = 0.029; cut-off 1172.0 pg/mL) and BNP (p < 0.001; cut-off 2194.0 pg/mL) showed significant results. Consequently, analyses of combined biomarkers were performed, which yielded IGF-BP2 + BNP (AUC = 0.721; 95%CI = 0.585−0.857; p = 0.004) as the best result of the two-way analyses and GDF-15 + IGF-BP2 + BNP (AUC = 0.727; 95%CI = 0.590−0.864; p = 0.004) as the best result of the three-way analyses. No significant difference regarding the 1-year survival between patients with PA/BSA < 16.6 mm/m2 and patients with PA/BSA ≥ 16.6 mm/m2 was found (log-rank test: p = 0.452). (4) Conclusions: Although PA/BSA aims to reduce the bias of the PA value caused by different body compositions and sizes, it is still a controversial parameter for diagnosing PH. Combining the parameter with different cardiovascular biomarkers did not lead to a significant increase in the diagnostic precision for detecting PH in patients with severe AS.

10.
J Clin Med ; 11(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36556020

RESUMO

NT-pro-BNP is produced in the cardiac atria and ventricles in response to increased wall stress. It may be a marker of both AF disease progression and co-morbidities that affect success after pulmonary vein isolation (PVI). This single-center retrospective study analyzed the association between pre-procedural NT-pro-BNP serum levels and the long-term outcome after a first-ever PVI in cryo-technique. Patients were followed by searching the hospital information system and conducting structured telephone interviews. Treatment failure was defined as any relapse of atrial fibrillation (AF) occurring 90 days after the index PVI at the earliest. Kaplan−Meier survival curves and Cox proportional hazards models were computed to assess the impact of NT-pro-BNP on AF recurrence. Following 374 patients over a median of 3.8 years (range: 0.25−9.4 years), baseline NT-pro-BNP was associated with the combined endpoint in univariate analysis (HR 1.04 per 100 pg/mL increase, 95% CI: 1.02−1.07, p < 0.001). Results were virtually unchanged in the multivariate model or if the data were log-transformed. Intraprocedural left atrial pressure correlated positively with log NT-pro-BNP. NT-pro-BNP was associated with AF relapse during a long-term follow-up after first-ever cryo-PVI in our cohort of patients with predominantly normal left ventricular function. This lab parameter is easy to obtain and has significant potential to guide treatment decisions.

11.
Diagnostics (Basel) ; 12(10)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36292052

RESUMO

Background: Computed tomography (CT) of the aorta and cardiac vessels, which is performed in patients with severe aortic valve stenosis (AS) before transcatheter aortic valve replacement (TAVR), offers the possibility of non-invasive detection of pulmonary hypertension (PH), for example, by determining the diameter of the main pulmonary artery (PA), the right pulmonary artery (RPA) or the left pulmonary artery (LPA). An improvement of the significance of these radiological parameters is often achieved by indexing to the body surface area (BSA). The aim of this study was to compare different echocardiographic systolic pulmonary artery pressure (sPAP) values with radiological data in order to define potential clinical cut-off values for the presence or absence of PH. Methods: A total of 138 patients with severe AS undergoing TAVR underwent pre-interventional transthoracic echocardiography with determination of sPAP values and performance of CT angiography (CTA) of the aorta and femoral arteries. Radiologically, the PA, RPA, LPA, and ascending aorta (AA) diameters were obtained. Vascular diameters were not only indexed to BSA but also ratios were created with AA diameter (for example PA/AA-ratio). From these CT-derived vascular parameters, AUROC curves were obtained regarding the prediction of different sPAP values (sPAP 40−45−50 mmHg) and finally correlation analyses were calculated. Results: The best AUROC and correlation analyses were generally obtained at an sPAP ≥ 40 mmHg. When considering diameters alone, the PA diameter was superior to the RPA and LPA. Indexing to BSA generally increased the diagnostic quality of the parameters, and finally, in a synopsis of all results, PA/BSA had the best AUC 0.741 (95% CI 0.646−0. 836; p < 0.001; YI 0.39; sensitivity 0.87; specificity 0.52) and Spearman's correlation coefficient (r = 0.408; p < 0.001) at an sPAP of ≥40 mmHg. Conclusions: Features related to pulmonary hypertension are fast and easily measurable on pre-TAVR CT and offer great potential regarding non-invasive detection of pulmonary hypertension in patients with severe AS and can support the echocardiographic diagnosis. In this study, the diameter of the main pulmonary artery with the additionally determined ratios were superior to the values of the right and left pulmonary artery. Additional indexing to body surface area and thus further individualization of the parameters with respect to height and weight can further improve the diagnostic quality.

12.
J Pers Med ; 12(9)2022 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-36143238

RESUMO

BACKGROUND: Patients with severe aortic valve stenosis (AS) often present with heart failure and sarcopenia. Sarcopenia, described as progressive degradation of skeletal muscle mass, has frequently been implicated as a cause of increased mortality, prolonged hospitalization and generalized poor outcome after transcatheter aortic valve replacement (TAVR). At present, sarcopenia is defined by the European Working Group on Sarcopenia in Older People (EWGSOP) based on clinical examination criteria and radiological imaging. The aim of the present study was to compare patients with Computed Tomography (CT)-diagnosed sarcopenia with regard to the expression of cardiovascular biomarkers in order to obtain additional, laboratory-chemical information. METHODS: A total of 179 patients with severe AS were included in this retrospective study. Sarcopenia was determined via CT by measurement of the psoas muscle area (PMA), which was indexed to body surface area (PMAi). According to previous studies, the lowest tertile was defined as sarcopenic. Patients with (59/179) and without sarcopenia (120/179) in the overall cohort were compared by gender-specific cut-offs with regard to the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR). Additionally, binary logistic regression analyses were calculated to detect possible predictors of the presence of sarcopenia. RESULTS: No statistical differences regarding one-year survival could be detected between sarcopenic and non-sarcopenic patients in survival curves (log rank test p = 0.179). In the entire cohort, only BNP and hemoglobin (HB) showed a statistically significant difference, with only HB emerging as a relevant predictor for the presence of sarcopenia after binary logistic regression analysis (p = 0.015). No relevant difference in biomarker expression could be found in the male cohort. Regarding the female cohort, statistically significant differences were found in BNP, HB and hematocrit (HK). In binary logistic regression, however, none of the investigated criteria could be related to sarcopenia. CONCLUSION: Regardless of gender, patients with imaging-based muscle degradation did not demonstrate significantly different cardiovascular biomarker expression compared to those without it.

13.
Minerva Med ; 2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35822856

RESUMO

BACKGROUND: Echocardiography is currently the noninvasive method of choice to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). However, radiological options are also available by determining the main pulmonary artery (MPA) diameter in the setting of CT angiography. The aim of the present study was to compare cardiovascular biomarkers with the MPA diameter to allow other ways of detecting PH in patients with severe AS. METHODS: 194 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) were included in this study and were divided into two groups based on the CT-angiographically determined MPA diameter. In accordance with ESC guidelines, a cut-off value of 29 mm was determined in this study, with the absence of PH defined by an MPA diameter < 29 mm (n = 79/194) and the presence of PH defined by an MPA diameter ≥ 29 mm (115/194). Immediately before interventional aortic valve replacement, blood samples were drawn from the subjects and relevant cardiovascular biomarkers such as BNP, cTnI, GDF-15, H-FABP, IGF-BP2 and suPAR were assessed. RESULTS: Patients with an MPA diameter ≥ 29 mm had significantly higher BNP (p = 0.004), cTnI (p = 0.039) and HFABP (p = 0.015) plasma levels, whereas GDF-15 (p = 0.140), IGF-BP2 ( p = 0.088) and suPAR (p = 0.140) showed no significant differences. In addition, cut-off values were calculated to predict an MPA diameter ≥ 29 mm. Significant results were shown with 1634.00 pg/ml for BNP (p = 0.004), with 16.50 pg/ml for cTnI (p = 0.039) and with 1.16 ng/ml for H-FABP (p = 0.016). In a combined biomarker analysis, the 2-way combination of BNP and IGF-BP2 (AUC 0.671; 95%CI 0.538 - 0.805; p = 0.023) and the 3-way combination of BNP, H-FABP and IGF-BP2 (AUC 0.685; 95%CI 0.551 - 0.818; p = 0.015) showed the best results. Biomarker follow-up at 3 and 12 months after TAVR did not require additional information gain. Regarding 1-year survival, no significant difference could be detected between patients with an MPA diameter < 29 mm compared to patients with ≥ 29 mm (log-rank test: p = 0.262). CONCLUSIONS: The MPA diameter remains a controversial parameter for the detection of PH in patients with severe AS. Standing on its own, this non-invasive parameter may not be precise enough to detect PH accurately. Combining this parameter with several biomarkers did not provide significant additional information.

14.
Front Neurol ; 13: 777808, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35401389

RESUMO

Introduction: Epidemiological studies show that increased physical activity is linked to a lower risk of breast cancer and mortality. As a result, physical activity can significantly improve patients' quality of life (QOL) both during and after therapy.Many breast cancer patients demonstrate a decrease in cognitive capacity, referred to as the symptom-complex cancer related cognitive impairment (CRCI). Most frequently reported impairments are mild to moderate deficits in processing speed, attention, memory, and executive functions. Cognitive symptoms persist for months or even years, following medical treatment in roughly 35% of afflicted people, impairing everyday functioning, limiting the ability to return to work, and lowering the overall QOL. Recent studies point toward a key role of inflammatory pathways in the CRCI genesis. Attention to physical activity as a potential supportive care option is therefore increasing. However, evidence for the positive effects of exercise on preventing CRCI is still lacking. Patients and Methods: Against this background, the prospective, two-arm, 1:1 randomized, controlled trial investigates the influence of first line chemotherapy accompanied by exercise training on preventing CRCI in 126 patients with breast cancer at the local University Hospital. The study will evaluate biomarkers and secondary assessments suspected to be involved in the pathogenesis of CRCI in addition to objective (primary outcome) and subjective cognitive function. CRCI is believed to be connected to either functional and/or morphological hippocampal damage due to chemotherapy. Thus, cerebral magnetic resonance imaging (MRI) and hippocampal volume measurements are performed. Furthermore, a specific neuropsychological test battery for breast cancer patients has been developed to detect early signs of cognitive impairments in patients and to be integrated into practice. Discussion: This study will explore how a long-term supervised exercise intervention program might prevent CRCI, enables optimization of supportive care and objectifies limits of psychological and physical resilience in breast cancer patients during and after chemotherapy treatment. Trial Registration: ClinicalTrials.gov: Identifier: NCT04789187. Registered on 09 March 2021.

15.
J Clin Med ; 11(5)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35268413

RESUMO

This multicenter European survey systematically evaluated the impact of using contact force-sensing catheters (CFSCs) on fluoroscopy and procedure time in interventional electrophysiology. Data from 25 participating centers were collected and analyzed, also considering important confounders. With the use of CFSCs, fluoroscopy time was reduced for right- and left-sided atrial ablations (median −6.4 to −9.6 min, p < 0.001 for both groups), whereas no such effect could be found for ventricular ablations. Moreover, the use of CFSCs was associated with an increase in procedure time for right-sided atrial and ventricular ablations (median +26.0 and +44.0 min, respectively, p < 0.001 for both groups), but not for left-sided atrial ablations. These findings were confirmed independent of career level and operator volume, except for very highly experienced electrophysiologists, in whom the effect was blunted. In the subset of pulmonary vein isolations (PVIs), CFSCs were shown to reduce both fluoroscopy and procedure time. In conclusion, the use of CFSCs was associated with a reduced fluoroscopy time for atrial ablations and an increased procedure time for right atrial and ventricular ablations. These effects were virtually independent of the operator experience and caseload. When considering only PVIs as an important subset, CFSCs were shown to reduce both fluoroscopy and procedure time.

16.
JACC Cardiovasc Interv ; 14(24): 2723-2732, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34949397

RESUMO

OBJECTIVES: The aims of this study were to evaluate the rate and time course of delayed total atrioventricular block (DT-AVB) after transcatheter aortic valve replacement (TAVR) using continuous electrocardiographic monitoring by implantable loop recorders and to identify potential predictors. BACKGROUND: DT-AVB has been defined as onset more than 2 days after TAVR or after hospital discharge and is reported in 10% to 15% of patients at 30-day follow-up. To date, there is no standardized diagnostic and therapeutic algorithm to manage TAVR patients at risk for DT-AVB. METHODS: Consecutive patients undergoing TAVR and simultaneous electrophysiologic testing without persistent or recurrent total atrioventricular block within 48 hours after the procedure underwent loop recorder implantation for full disclosure of atrioventricular conduction during 12-month follow-up. RESULTS: DT-AVB occurred in 7 of 59 patients (11.9%), with onset between 2 days and 3 months after the procedure. Both prolongation of the PQ interval between baseline and day 2 after TAVR (OR: 1.04; 95% CI: 1.01-1.09); P = 0.032) and prolongation of the HV interval during the procedure (OR: 1.07; 95% CI: 1.02-1.14; P = 0.015) significantly predicted the onset of DT-AVB. CONCLUSIONS: TAVR was associated with a considerable rate of DT-AVB of nearly 12% in this series. Prolongation of the PQ interval between baseline and day 2 and intraprocedural prolongation of the HV interval were significant predictors of DT-AVB.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Eletrocardiografia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
J Clin Lab Anal ; 35(11): e23977, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34562276

RESUMO

BACKGROUND: Systemic inflammation has been identified as a major cardiovascular risk factor in patients undergoing transcatheter aortic valve replacement (TAVR), yet currently, it is not adequately portrayed in scores for pre-interventional risk assessment. The aim of this study was to investigate the predictive ability of TNF-α in TAVR. METHODS: A total of 431 patients undergoing transfemoral TAVR were enrolled in this study. Blood samples were drawn prior to intervention, 24 h post-intervention, 4, 5, and 7 days post-intervention, and 1, 3, and 6 months post-TAVR. RESULTS: In a univariate Cox proportional hazard analysis, plasma concentrations of TNF-α after 24 h and after 5 days were associated with mortality after 12 months (after 24 h: HR 1.002 (1.000-1.004), p = 0.028; after 5d: HR 1.003 (1.001-1.005), p = 0.013). This association remained significant even after correction for confounders in a multivariate Cox regression analysis. Additionally, cut-offs were calculated. Patients above the cut-off for TNF-α after 5d had a significantly worse 12-month mortality than patients below the cut-off (18.8% vs. 2.8%, p = 0.046). CONCLUSION: Plasma levels of TNF-α after 24 h and 5 days were independently associated with 12-month mortality in patients undergoing TAVR. Thus, TNF-α could represent a novel biomarker for enhanced risk stratification in these patients.


Assuntos
Substituição da Valva Aórtica Transcateter , Fator de Necrose Tumoral alfa/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Inflamação , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade
18.
J Cardiovasc Electrophysiol ; 32(9): 2522-2527, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34270153

RESUMO

BACKGROUND: Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS: Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS: LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.


Assuntos
Estado Terminal , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Desenho de Equipamento , Humanos , Estudos Retrospectivos , Resultado do Tratamento
19.
Medicine (Baltimore) ; 100(21): e26148, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34032769

RESUMO

RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS: We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P2)/segment 3 of the posterior mitral valve leaflet (P3) 4 years before. DIAGNOSES: Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS: After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES: The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS: As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.


Assuntos
Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Recidiva , Reoperação
20.
J Clin Med ; 10(4)2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33671264

RESUMO

The relationship of statin therapy with recurrence of atrial fibrillation (AF) after cardioversion (CV) has been evaluated by several investigations, which provided conflicting results and particularly long-term data is scarce. We sought to examine whether upstream statin therapy is associated with long-term recurrence of AF after CV. This was a single-center registry study including consecutive AF patients (n = 454) undergoing CV. Cox regression models were performed to estimate AF recurrence comparing patients with and without statins. In addition, we performed a propensity score matched analysis with a 1:1 ratio. Statins were prescribed to 183 (40.3%) patients. After a median follow-up period of 373 (207-805) days, recurrence of AF was present in 150 (33.0%) patients. Patients receiving statins had a significantly lower rate of AF recurrence (log-rank p < 0.001). In univariate analysis, statin therapy was associated with a significantly reduced rate of AF recurrence (HR 0.333 (95% CI 0.225-0.493), p = 0.001), which remained significant after adjustment (HR 0.238 (95% CI 0.151-0.375), p < 0.001). After propensity score matching treatment with statins resulted in an absolute risk reduction of 27.5% for recurrent AF (21 (18.1%) vs. 53 (45.7%); p < 0.001). Statin therapy was associated with a reduced risk of long-term AF recurrence after successful cardioversion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA