Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Front Immunol ; 15: 1416914, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38817605

RESUMO

Background: Angiogenesis, the process of forming new blood vessels from pre-existing ones, plays a crucial role in the development and advancement of cancer. Although blocking angiogenesis has shown success in treating different types of solid tumors, its relevance in prostate adenocarcinoma (PRAD) has not been thoroughly investigated. Method: This study utilized the WGCNA method to identify angiogenesis-related genes and assessed their diagnostic and prognostic value in patients with PRAD through cluster analysis. A diagnostic model was constructed using multiple machine learning techniques, while a prognostic model was developed employing the LASSO algorithm, underscoring the relevance of angiogenesis-related genes in PRAD. Further analysis identified MAP7D3 as the most significant prognostic gene among angiogenesis-related genes using multivariate Cox regression analysis and various machine learning algorithms. The study also investigated the correlation between MAP7D3 and immune infiltration as well as drug sensitivity in PRAD. Molecular docking analysis was conducted to assess the binding affinity of MAP7D3 to angiogenic drugs. Immunohistochemistry analysis of 60 PRAD tissue samples confirmed the expression and prognostic value of MAP7D3. Result: Overall, the study identified 10 key angiogenesis-related genes through WGCNA and demonstrated their potential prognostic and immune-related implications in PRAD patients. MAP7D3 is found to be closely associated with the prognosis of PRAD and its response to immunotherapy. Through molecular docking studies, it was revealed that MAP7D3 exhibits a high binding affinity to angiogenic drugs. Furthermore, experimental data confirmed the upregulation of MAP7D3 in PRAD, correlating with a poorer prognosis. Conclusion: Our study confirmed the important role of angiogenesis-related genes in PRAD and identified a new angiogenesis-related target MAP7D3.


Assuntos
Adenocarcinoma , Imunoterapia , Aprendizado de Máquina , Neovascularização Patológica , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/genética , Neoplasias da Próstata/imunologia , Neoplasias da Próstata/terapia , Prognóstico , Neovascularização Patológica/genética , Neovascularização Patológica/imunologia , Imunoterapia/métodos , Adenocarcinoma/genética , Adenocarcinoma/imunologia , Adenocarcinoma/terapia , Biomarcadores Tumorais/genética , Regulação Neoplásica da Expressão Gênica , Proteínas Associadas aos Microtúbulos/genética , Simulação de Acoplamento Molecular , Perfilação da Expressão Gênica , Angiogênese
2.
J Cell Mol Med ; 28(10): e18384, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38760964

RESUMO

Smoking is a well-known risk factor for non-small-cell lung cancer (NSCLC) and bladder urothelial carcinoma (BLCA). Despite this, there has been no investigation into a prognostic marker based on smoking-related genes that could universally predict prognosis in these cancers and correlate with immune checkpoint therapy. This study aimed to identify smoking-related differential genes in NSCLC and BLCA, analyse their roles in patient prognosis and immune checkpoint therapy through subgroup analyses, and shed light on PRR11 as a crucial prognostic gene in both cancers. By examining PRR11 co-expressed genes, a prognostic model was constructed and its impact on immunotherapy for NSCLC and BLCA was evaluated. Molecular docking and tissue microarray analyses were conducted to explore the correlation between PRR11 and its reciprocal gene SPDL1. Additionally, miRNAs associated with PRR11 were analysed. The study confirmed a strong link between smoking-related genes, prognosis, and immune checkpoint therapy in NSCLC and BLCA. PRR11 was identified as a key smoking-associated gene that influences the efficacy of immune checkpoint therapy by modulating the stemness of these cancers. A prognostic model based on PRR11 co-expressed genes in BLCA was established and its prognostic value was validated in NSCLC. Furthermore, it was found that PRR11 regulates PDL1 via SPDL1, impacting immunotherapeutic efficacy in both cancers. The involvement of hsa-miR-200b-3p in the regulation of SPDL1 expression by PRR11 was also highlighted. Overall, the study elucidates that PRR11 modulates patient immunotherapy by influencing PDL1 expression through its interaction with SPDL1, with potential upstream regulation by hsa-miR-200b-3p.


Assuntos
Regulação Neoplásica da Expressão Gênica , Imunoterapia , Neoplasias Pulmonares , MicroRNAs , Fumar , Neoplasias da Bexiga Urinária , Humanos , Neoplasias da Bexiga Urinária/genética , Neoplasias da Bexiga Urinária/imunologia , Neoplasias da Bexiga Urinária/terapia , Neoplasias da Bexiga Urinária/patologia , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/terapia , Prognóstico , Fumar/efeitos adversos , Imunoterapia/métodos , MicroRNAs/genética , Biomarcadores Tumorais/genética , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/terapia , Carcinoma Pulmonar de Células não Pequenas/patologia , Masculino , Feminino
3.
Br J Radiol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775639

RESUMO

OBJECTIVES: This study aimed to explore the differences between tall-cell subtype of papillary thyroid carcinoma (TCPTC) and classical papillary thyroid carcinoma (cPTC) using multimodal ultrasound, and identify independent risk factors for TCPTC to compensate the deficiency of preoperative cytological and molecular diagnosis on PTC subtypes. METHODS: 46 TCPTC patients and 92 cPTC patients were included. Each patient received grey-scale ultrasound, color Dopplor flow imaging (CDFI) and shear-wave elastography (SWE) preoperatively. Clinicopathologic information, grey-scale ultrasound features, CDFI features and SWE features of 98 lesion were compared using univariate analysis to find out predictors of TCPTC, based on which, a predictive model was built to differentiate TCPTC from cPTC and validated with 40 patients. RESULTS: Univariate and multivariate analysis identified that extrathyroidal extension (OR, 15.12; 95% CI, 2.26-115.44), aspect ratio (≥0.91) (OR, 29.34; 95% CI, 1.29-26.23), and maximum diameter ≥ 14.6 mm (OR, 20.79; 95% CI, 3.87-111.47) were the independent risk factors for TCPTC. Logistic regression equation: p = 1/1+ExpΣ[-5.099 + 3.004 × (if size ≥14.6 mm)+2.957 × (if aspect ratio≥0.91)+2.819 × (if extra-thyroidal extension)]. The prediction model had a good discrimination performance for TCPTC: the AUC, sensitivity and specificity were 0.928, 0.848 and 0.954 in cohort 1, and the corresponding values in cohort 2 were 0.943, 0.923 and 0.926. CONCLUSION: Ultrasound has potential for differential diagnosis of TCPTC from cPTC. A prediction model based on ultrasound characteristics (extrathyroidal extension, aspect ratio ≥0.91, and maximum diameter ≥14.6 mm) was useful to predict TCPTC. ADVANCES IN KNOWLEDGE: Multimodal ultrasound prediction of TCPTC were supplements to preoperative cytological diagnosis and molecular diagnosis on PTC subtypes.

4.
Nat Commun ; 14(1): 5676, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37709761

RESUMO

Native mass spectrometry (MS) is a powerful technique for interrogating membrane protein complexes and their interactions with other molecules. A key aspect of the technique is the ability to preserve native-like structures and noncovalent interactions, which can be challenging depending on the choice of detergent. Different strategies have been employed to reduce charge on protein complexes to minimize activation and preserve non-covalent interactions. Here, we report the synthesis of a class of polyamine detergents tailored for native MS studies of membrane proteins. These detergents, a series of spermine covalently attached to various alkyl tails, are exceptional charge-reducing molecules, exhibiting a ten-fold enhanced potency over spermine. Addition of polyamine detergents to proteins solubilized in maltoside detergents results in improved, charge-reduced native mass spectra and reduced dissociation of subunits. Polyamine detergents open new opportunities to investigate membrane proteins in different detergent environments that have thwarted previous native MS studies.


Assuntos
Proteínas de Membrana , Poliaminas , Detergentes , Espermina , Espectrometria de Massas
5.
Endocrine ; 80(1): 111-123, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36495391

RESUMO

BACKGROUND: This study aimed to establish predictive models based on features of Conventional Ultrasound (CUS) and elastography in a multi-center study to determine appropriate preoperative diagnosis of malignancy in thyroid nodules with different risk stratification based on 2017 Thyroid Imaging Reporting and Data System by the American College of Radiology (ACR TI-RADS) guidelines. METHODS: Five hundred forty-eight thyroid nodules from three centers pathologically confirmed by the cytology or histology were retrospectively enrolled in the study, which were examined by CUS and elastography before fine needle aspiration (FNA) and surgery. Characteristics of CUS of thyroid nodules were reviewed according to 2017 ACR TI-RADS. Binary logistic regression analysis was used to develop the prediction models based on the different risk stratification of CUS features and elastography which were statistically significant. Values of predictive models were evaluated regarding the discrimination and calibration. RESULTS: Binary logistic regression showed that patients' age, taller-than-wider, lobulated or irregular boundary, extra-thyroid extension, microcalcification and the elastic parameter of Virtual touch tissue imaging quantification (VTIQ) max were independent predictors for thyroid malignancy (p < 0.05) in the ACR model and showed the area under the curve (AUC) in training (0.912) and validation cohort (internal and external: 0.877 vs 0.935). Predictive models showed predictors in ACR TR4 and TR5 for malignancy and diagnostic performance of AUC in training, internal and external validation cohort respectively: the VTIQ max (p < 0.001) with AUC of 0.809 vs 0.842 vs 0.705 and the age, taller than wide, VTIQ max variables with AUC of 0.859 vs 0.830 vs 0.906 in validation cohort. All predictive models have better calibration capabilities (p > 0.05). CONCLUSIONS: Predictive models combined CUS and elastography features would aid clinicians to make appropriate preoperative diagnosis of thyroid nodules among different risk stratification. The elastography parameter of VTIQ max has the priority in distinguishing thyroid malignancy with moderately suspicious (ACR TR4).


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Estudos Retrospectivos , Ultrassonografia/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia
6.
Br J Radiol ; 96(1141): 20220404, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36400064

RESUMO

OBJECTIVE: To assess the added value of contrast-enhanced ultrasound (CEUS) to conventional ultrasound in differentiating benign soft-tissue tumors from malignant ones. METHODS: 197 soft-tissue tumors underwent ultrasound examination with confirmed histopathology were retrospectively evaluated. The radiologists classified all the tumors as benign, malignant, or indeterminate according to ultrasound features. The indeterminate tumors underwent CEUS were reviewed afterwards for malignancy identification by using individual and combined CEUS features. RESULTS: Ultrasound analysis classified 62 soft-tissue tumors as benign, 111 tumors as indeterminate and 24 tumors as malignant. There 104 indeterminate tumors were subject to CEUS. Three CEUS features including enlargement of enhancement area, infiltrative enhancement boundary, and intratumoral arrival time difference were significantly associated with the tumor nature in both univariable and multivariable analysis for the indeterminate tumors (all p < 0.05). When at least one out of the three discriminant CEUS features were present, the best sensitivity of 100% for malignancy identification was obtained with the specificity of 66.7% and the AUC of 0.833. When at least two of the three discriminant CEUS features were present, the best area under the receiver operating characteristic curve (AUC) of 0.924 for malignancy identification was obtained. The combination of at least two discriminant CEUS features showed much better diagnostic performance than the optimal combination of ultrasound features in terms of AUC (0.924 vs 0.608, p < 0.0001), sensitivity (94.0% vs 42.0%, p < 0.0001), and specificity (90.7% vs 79.6%, p = 0.210) for the indeterminate tumors. CONCLUSION: The combination CEUS features of enlargement of enhancement area, infiltrative enhancement boundary and intratumoral arrival time difference are valuable to improve the discriminating performance for indeterminate soft-tissue tumors on conventional ultrasound. ADVANCES IN KNOWLEDGE: The combination of peritumoral and arrival-time CEUS features can improve the discriminating performance for indeterminate soft-tissue tumors on conventional ultrasound.


Assuntos
Meios de Contraste , Neoplasias de Tecidos Moles , Humanos , Estudos Retrospectivos , Ultrassonografia , Curva ROC , Neoplasias de Tecidos Moles/diagnóstico por imagem , Sensibilidade e Especificidade
7.
Mater Horiz ; 9(1): 452-461, 2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-34846413

RESUMO

Low-cost and scalable superhydrophobic coating methods provide viable approaches for energy-efficient separation of immiscible liquid/liquid mixtures. A scalable photopolymerization method is developed to functionalize porous substrates with a hybrid coating of tetrapodal ZnO (T-ZnO) and polymethacrylate, which exhibits simultaneous superhydrophobicity and superoleophilicity. Here, T-ZnO serves dual purposes by (i) initiating radical photopolymerization during the fabrication process through a hole-mediated pathway and (ii) providing a hierarchical surface roughness to amplify wettability characteristics and suspend liquid droplets in the metastable Cassie-Baxter regime. Photopolymerization provides a means to finely control the conversion and spatial distribution of the formed polymer, whilst allowing for facile large-area fabrication and potential coating on heat-sensitive substrates. Coated stainless-steel meshes and filter papers with desired superhydrophobic/superoleophilic properties exhibit excellent performance in separating stratified oil/water, oil/ionic-liquid, and water/ionic-liquid mixtures as well as water-in-oil emulsions. The hybrid coating demonstrates desired mechanical robustness and chemical resistance for their long-term application in large-scale energy-efficient separation of immiscible liquid/liquid mixtures.

8.
Clin Hemorheol Microcirc ; 75(3): 291-301, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32280082

RESUMO

The purpose of the study was to explore the differences of conventional ultrasound characteristics, thyroid imaging reporting and data system (TI-RADS) category and shear wave speed (SWS) measurement between follicular adenoma (FA) and follicular thyroid carcinoma (FTC). Twenty-eight FTCs and 67 FAs proven by surgery were retrospectively included for analysis. Conventional ultrasound and point-shear wave elastography (p-SWE) were performed in all of the included patients. The ultrasound features, American Thyroid Association (ATA) TI-RADS category and American College of Radiology (ACR) TI-RADS category, SWS measurement were compared between the two groups. Receiver operating characteristic (ROC) curve was performed and area under ROC curve (AUC) was obtained for significant features. There were no statistical differences in mean age (46.9±15.7years vs. 48.6±13.6years, P = 0.639), gender (9 males, 32.1% vs. 18 males, 29.0%, P = 0.766) and mean diameter (28.3±16.2 mm vs. 33.8±11.9 mm, P = 0.077) between FTCs and FAs. Hypoechogenicity, lobulated or irregular margin, macrocalcification were more common in FTCs than FAs (all P < 0.05). Mean SWS of FTCs (2.29±0.64 m/s) was slightly higher than that of FAs (1.94±0.68 m/s) (P = 0.023). The AUCs were 0.655, 0.744, and 0.744 with the cut-off SWS≥1.89 m/s, ACR TI-RADS category 4 and intermediate suspicion of ATA TI-RADS category. The sensitivity and AUC were 82.1% and 0.812 with combined ultrasound features of hypoechogenicity, lobulated or irregular margin and macrocalcification. In Conclusion, SWS measurement and TI-RADS categories were useful for the identification of FTCs from FAs.


Assuntos
Adenocarcinoma Folicular/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Clin Hemorheol Microcirc ; 75(2): 219-232, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929154

RESUMO

OBJECTIVE: To compare the diagnostic performance and the unnecessary biopsy rates for recommending fine needle aspiration (FNA) of Thyroid Imaging Reporting and Data Systems proposed by American College of Radiology (ACR TI-RADS), American Thyroid Association (ATA) guidelines, TI-RADS proposed by Kwak (Kwak TI-RADS), and Korean Thyroid Association/Korean Society of Thyroid Radiology (KTA/KSThR) guidelines for malignancy risk stratification of thyroid nodules (TNs). METHODS: The study included 1271 TNs whose cytologic results or surgical pathologic findings were available. Ultrasound images of these TNs were retrospectively reviewed and categorized according to the four guidelines. The diagnostic performances and the unnecessary biopsy rates for recommending FNA of the four guidelines were evaluated. RESULTS: After multivariate analysis, the most significant independent predictor for malignancy was hypoechogenicity/marked hypoechogenicity (OR: 9.37, 95% CI: 5.40-16.26) (P < 0.001) among the suspicious ultrasound images features. For all nodules and two subgroups (i.e. nodules <10 mm group and nodules ≥10 mm group), ACR TI-RADS demonstrated higher specificities (all P < 0.05) and lower sensitivities (all P < 0.001) than the other guidelines. In the all nodules group and the nodules<10 mm group, ACR TI-RADS and Kwak TI-RADS had higher Azs than the other guidelines (all P < 0.01). The unnecessary biopsy rates for recommending FNA of ACR TI-RADS in the all nodules (≥10 mm) group and the subgroup (10∼19 mm) were all lower than those of the others guidelines (P < 0.001 for all). For the subgroup (≥20 mm), the unnecessary biopsy rate of ACR was lower than that of ATA guidelines and KTA/KSThR guidelines (P < 0.001). CONCLUSIONS: The four guidelines have good diagnostic efficiency in differentiating TNs. ACR TI-RADS and Kwak TI-RADS have better diagnostic performance than the other guidelines in the all nodules group and the nodules<10 mm group. Considering the comprehensive diagnostic efficacy and unnecessary biopsy rate, ACR TI-RADS is a more desirable classification guideline in clinical practice.


Assuntos
Nódulo da Glândula Tireoide/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , República Democrática Popular da Coreia/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Nódulo da Glândula Tireoide/patologia , Adulto Jovem
10.
ACS Appl Mater Interfaces ; 11(26): 23417-23427, 2019 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-31252481

RESUMO

Three D-A-D-configured molecules DTPBT, DTPNT, and DTPNBT with high quantum yield of orange red (628 nm), red (659 nm), and deep-red/NIR (710 nm) fluorescence, respectively, were developed as emitting dopants in an exciplex-forming cohost (TCTA:3P-T2T) for high-efficiency fluorescence-based organic light-emitting diodes (OLEDs). The obtained physical properties together with theoretical calculations analyzed from these new molecules establish a clear structure-property relationship, in which the feature of central acceptor 2,1,3-benzothiadiazole (BT), naphtho[1,2-c:5,6-c']bis[1,2,5]thiadiazole (NT), and 2,1,3-naphthothiadiazole (NBT) plays the crucial role for governing the physical characteristics. The optimized device configured as ITO/HAT-CN/TAPC/TCTA/TCTA:3P-T2T:5% emitter/3P-T2T/LiF/Al gave a record-high efficiency of orange red (591 nm, 15%), red (647 nm, 10%), and deep-red/NIR (689 nm, 9%) electroluminescent devices. The effective harvest of triplet excitons with an exciplex-forming system in conjunction with efficient energy transfer between the exciplex and the dopant is beneficial for such high device efficiencies. More importantly, the stable exciplex-forming cohost and fast radiative decay rate of DTPNT render this particular device exhibiting high device stability as indicated by the low efficiency roll-off under high current densities (EQE (external quantum efficiency) values of 8.1% at 1000 cd m-2 and 6.8% at 10,000 cd m-2). These results reveal the potential of employing an exciplex-forming system as cohost for fluorescent dopants to furnish high-efficiency OLEDs with an emission wavelength extending to the red or even the NIR range.

11.
Clin Hemorheol Microcirc ; 72(2): 151-160, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30689559

RESUMO

OBJECTIVE: To investigate the stiffness distribution in the ablated zone after radiofrequency ablation (RFA), we used a device called tissue elastometer based on gross liver samples. MATERIALS: AND METHODS: Twelve freshly excised porcine livers were subject to RFA under a same setup to form elliptic ablated samples. Each sample was cut open for gross examination, and then the surface of the section plane was sliced into one piece for Young's modulus test using the tissue elastometer. Five test points along the long- and short-axis on each piece were selected to evaluate stiffness distribution respectively. Among them, four points distributed equidistantly from center to boundary in the ablated zone and one was in the unablated zone. RESULTS: In the ablated zone, we found the Young's moduli were significantly different among the four test points both in long- (F = 99.04, p <0.001) and short-axis (F = 79.47, p <0.001) directions. The Young's modulus showed a downtrend in each direction, and was linearly related to the distance from the center to the test point (for long axis, R2 = 0.968; for short axis, R2 = 0.984, both p <0.001). A more significant downtrend was observed in short-axis direction. The Young's moduli gained from the inner edge of ablated zone were comparable and significantly higher than those from the outer edge for both directions. The maximum value of 24.71kPa for Young's modulus was the appropriate threshold to ensure the tissues were necrotic completely. CONCLUSION: The stiffness inside the ablated zone represented a radial distribution with downtrend, following a linear law. The stiffness at the inner edge of ablated zone is stable and significantly higher than that at the outer edge. The maximum value of 24.71 kPa close to the inner edge of Wz may be used as the standard of complete ablation.


Assuntos
Ablação por Cateter/métodos , Fígado/efeitos da radiação , Ablação por Radiofrequência/métodos , Animais , Módulo de Elasticidade , Humanos , Suínos
12.
Clin Hemorheol Microcirc ; 72(1): 39-60, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30320562

RESUMO

Ultrasound elastography has been introduced into clinical practice for a decade and arisen continuous increasing attention worldwide. Shear wave elastography (SWE) is a further extension of ultrasound elastography on the basis of strain elastography, providing a two-dimensional distribution map of tissue stiffness and quantitative measurement of the tissue stiffness in Young's modulus (kPa) and/or shear wave speed (m/s). The Society of Ultrasound in Medicine, Chinese Medical Association (CMA) has recently released a series of guidelines for the use of SWE, including the technique and principle of SWE, and use of SWE in liver fibrosis, breast, thyroid, and musculoskeletal system. Herein, a part of SWE in thyroid nodules is presented. In this guideline, the background, classification and technology of SWE, examination methods, diagnostic performance, prognosis evaluation, reproducibility, and limitations are discussed and recommendations are given. The recommendations are based on the published literatures with regard to SWE with different levels of evidence, particularly a mid-term result of the prospective multi-center clinical trial of SWE in thyroid, as well as the Society of Ultrasound in Medicine, CMA expert's consensus. The document provides an overall analysis of SWE in thyroid from clinical perspective, which aimed to provide recommendations to the clinicians with regard to the management of thyroid nodules by the assistance of SWE.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico , Guias como Assunto , Humanos , Estudos Prospectivos , Nódulo da Glândula Tireoide/patologia
13.
Clin Hemorheol Microcirc ; 69(3): 355-370, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29660903

RESUMO

OBJECTIVE: To assess the performance of conventional high frequency ultrasound (US) and US elastography in diagnosis of complex cystic and solid breast lesions. METHODS: Ninety three lesions in 93 patients underwent conventional US and US elastography, including strain elastography, acoustic radiation force impulse (ARFI) imaging, and point shear wave speed (SWS) measurement. RESULTS: Pathological examination revealed 31 (33.3%) of the 93 lesions were malignant and the remaining 62 (66.7%) were benign. Multivariate analysis showed that elder patient (OR: 25.301), internal vascularity (OR: 4.518), and not circumscribed margin (OR: 3.813) were independent predictors for malignancy, while predominately cystic lesions (OR: 0.178) was a predictor for benign lesions (all p < 0.05). Invalid SWS measurement was occurred in 19 of 31 (61.3%) malignant lesions and 16 of 62 (25.8%) benign lesions, respectively (p < 0.05). The mean SWS value for malignant lesions was significantly lower than that for benign ones, being 1.60±0.63 m/s (range, 0.68-2.70 m/s) versus 2.33±0.77 m/s (range, 0.67-3.97 m/s) (p < 0.05). Areas under the ROC curve (Azs) for Breast Imaging Reporting and Data System (BI-RADS) assessment, strain elasticity score, ARFI imaging and valid point SWS measurement were 0.844, 0.734, 0.763 and 0.778,respectively. CONCLUSIONS: US BI-RADS category, strain elastography score, ARFI imaging patterns and point SWS measurement are useful for malignancy prediction of complex cystic and solid breast lesions. The result that SWS for malignant lesions is lower than benign one should be carefully interpreted since invalid SWS measurement is excluded for analysis. The true stiffness of malignant cystic and solid lesions should be further evaluated with a new generation of two-dimensional SWS imaging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adulto , Feminino , Humanos , Estudos Retrospectivos
14.
Clin Hemorheol Microcirc ; 69(3): 425-436, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29660908

RESUMO

OBJECTIVE: To evaluate a special kind of ultrasound (US) shear wave elastography for differential diagnosis of breast lesions, using a new qualitative analysis (i.e. the elasticity score in the travel time map) compared with conventional quantitative analysis. METHODS: From June 2014 to July 2015, 266 pathologically proven breast lesions were enrolled in this study. The maximum, mean, median, minimum, and standard deviation of shear wave speed (SWS) values (m/s) were assessed. The elasticity score, a new qualitative feature, was evaluated in the travel time map. The area under the receiver operating characteristic (AUROC) curves were plotted to evaluate the diagnostic performance of both qualitative and quantitative analyses for differentiation of breast lesions. RESULTS: Among all quantitative parameters, SWS-max showed the highest AUROC (0.805; 95% CI: 0.752, 0.851) compared with SWS-mean (0.786; 95% CI:0.732, 0.834; P = 0.094), SWS-median (0.775; 95% CI:0.720, 0.824; P = 0.046), SWS-min (0.675; 95% CI:0.615, 0.731; P = 0.000), and SWS-SD (0.768; 95% CI:0.712, 0.817; P = 0.074). The AUROC of qualitative analysis in this study obtained the best diagnostic performance (0.871; 95% CI: 0.825, 0.909, compared with the best parameter of SWS-max in quantitative analysis, P = 0.011). CONCLUSIONS: The new qualitative analysis of shear wave travel time showed the superior diagnostic performance in the differentiation of breast lesions in comparison with conventional quantitative analysis.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Pesquisa Qualitativa , Estudos Retrospectivos , Adulto Jovem
15.
J Ultrasound Med ; 37(3): 725-736, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28960465

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of Virtual Touch tissue imaging quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) in combination with the Thyroid Imaging Reporting and Data System (TI-RADS) for assessing thyroid nodules referred for biopsy. METHODS: A total of 197 surgically or cytologically proven thyroid nodules in 187 patients were included. Nodules evaluated by conventional ultrasound (US) and VTIQ examinations were classified into US TI-RADS categories. The shear wave velocity (SWV) on VTIQ was assessed, and the cutoff value was obtained from a receiver operating characteristic curve analysis. Diagnostic performances of conventional US, VTIQ, and their combination were compared. RESULTS: There were 134 benign and 63 malignant nodules. The sensitivity and specificity for the US TI-RADS were 98.4% and 20.1%, respectively. The areas under the receiver operating characteristic curves for the mean, maximum, minimum, and ratio of the SWV were 0.818, 0.805, 0.799, and 0.728. With a cutoff value of 2.90 m/s, the sensitivity and specificity of the mean SWV were 71.4% and 82.8%. By applying this value or less as a standard for downgrading TI-RADS category 4a to category 3 lesions, the specificity significantly rose from 20.1% to 47.0% (P < .001) without a loss of sensitivity. CONCLUSIONS: The additional application of VTIQ can improve the specificity of the TI-RADS for evaluating thyroid nodules without a loss of sensitivity.


Assuntos
Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Biópsia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Interface Usuário-Computador , Adulto Jovem
16.
ACS Appl Mater Interfaces ; 9(41): 36045-36052, 2017 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-28933148

RESUMO

We report a series of molecules that spontaneously self-organize into small electroluminescent domains of sub-micrometer dimensions when dissolved in tetrahydrofuran. The self-assembled spherical aggregates have an average diameter of 300 nm and exhibit efficient energy transfer from the blue to the green or red component. The aggregates can be chromatically addressed or patterned by selective bleaching of the energy-acceptor component using a laser source. This allows the fabrication of electroluminescence devices by directly photopatterning the active layer without the need of additional steps. Submicron features (700 nm) can be achieved using a collimated light source.

17.
Sci Rep ; 7(1): 7036, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28765627

RESUMO

To evaluate the diagnostic performance of shear wave arrival time contour (SWATC) display for the diagnosis of breast lesions and to identify factors associated with the quality of shear wave propagation (QSWP) in breast lesions. This study included 277 pathologically confirmed breast lesions. Conventional B-mode ultrasound characteristics and shear wave elastography parameters were computed. Using the SWATC display, the QSWP of each lesion was assigned to a two-point scale: score 1 (low quality) and score 2 (high quality). Binary logistic regression analysis was performed to identify factors associated with QSWP. The area under the receiver operating characteristic curve (AUROC) for QSWP to differentiate benign from malignant lesions was 0.913, with a sensitivity of 91.9%, a specificity of 90.7%, a positive predictive value (PPV) of 74.0%, and a negative predictive value (NPV) of 97.5%. Compared with using the standard deviation of shear wave speed (SWSSD) alone, SWSSD combined with QSWP increased the sensitivity from 75.8% to 93.5%, but decreased the specificity from 95.8% to 89.3% (P < 0.05). SWSSD was identified to be the strongest factor associated with the QSWP, followed by tumor malignancy and the depth of the lesion. In conclusion, SWATC display may be useful for characterization of breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Neoplasias/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
18.
Br J Radiol ; 90(1078): 20170063, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28749166

RESUMO

OBJECTIVE: To evaluate the value of fusion imaging with post-treatment contrast-enhanced ultrasound (CEUS) and pre-treatment contrast-enhanced CT/MRI (CECT/CEMRI) in evaluating ablative safety margin after percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) for liver cancers. METHODS: 34 consecutive patients with 47 liver lesions who had undergone RFA were included. Fusion imaging with post-treatment CEUS and pre-treatment CECT/CEMRI was carried out to evaluate local treatment response and ablative safety margin within 1-3 days after RFA. The minimal ablative safety margins of the ablation zones were recorded. The complete response (CR) rate was calculated with reference to CECT/CEMRI results 1 month after RFA. The local tumour progression (LTP) was also recorded. RESULTS: Of the 47 ablation zones, 47 (100%) were clearly depicted with CEUS-CECT/CEMRI fusion imaging, 36 (76.6%) with US-CECT/CEMRI fusion imaging and 21 (44.7%) with conventional US (both p < 0.001). The minimal ablative safety margins were great than or equal to 5 mm in 28 ablation zones, between 0 and 5 mm in 15, and less than 0 mm in 4. For the four lesions without enough ablative safety margin, three were referred to follow-up because CEUS showed larger ablation zones than pre-treatment lesions and the remaining lesion was subject to additional RFA 5 days after the first RFA. The CR rate was 95.7% (45/47) with reference to CECT/CEMRI results 1 month after RFA. During 2 to 34 months follow-up, LTP was found in two (4.4%) of 45 lesions with CR. Insufficient ablative safety margin was more commonly found in those lesions with LTP than those without LTP (1/4 vs 1/43, p < 0.001). CONCLUSION: Fusion imaging with post-treatment CEUS and pre-treatment CECT/CEMRI can depict the ablative safety margin accurately after RFA. Inadequate ablative safety margin is associated with LTP. Depiction of ablative safety margin by fusion imaging after ablation might be considered as a routine procedure to assess the treatment response of RFA. Advances in knowledge: Fusion imaging with post-treatment CEUS and pre-treatment CECT/CEMRI is an effective method to evaluate the ablative safety margin early after RFA. Therefore, it should be recommended to be used as a routine procedure after RFA for liver cancers.


Assuntos
Técnicas de Ablação , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Margens de Excisão , Imagem Multimodal , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Ultrassonografia , Técnicas de Ablação/métodos , Adulto , Idoso , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Estudos Retrospectivos
19.
Sci Rep ; 7(1): 5076, 2017 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-28698632

RESUMO

This study aimed to identify the associated factors for quality measurement (QM) of shear wave speed (SWS) imaging and to validate the additional value of QM in the diagnosis of breast lesions. From September 2014 to February 2015, conventional ultrasound and SWS imaging were performed in 338 women with 361 breast lesions. Binary logistic regression was used to identify associated factors for QM. Sensitivity, specificity and the area under receiver operating characteristic (ROC) curve (AUC) among maximum SWS (SWS max ), QM and SWS max plus QM (SWS max +QM) were compared to validate additional value of QM. Pathology confirmed 263 (72.9%) benign lesions and 98 (27.1%) malignancies. Maximum depth (Odds ratio [OR]: 1.398) and posterior features (OR: 1.206) were identified as independent associated factors for QM. Compared with SWS max and QM, the sensitivity of SWS max +QM increased from 67.3%, 64.3% to 83.7% whereas the specificity decreased from 90.5%, 72.6% to 65.4% (all P < 0.05). SWS max had the highest AUC in comparison with QM and SWS max +QM (0.849 vs. 0.685 vs. 0.745; P < 0.05). QM for breast lesions is associated with maximum depth and posterior features. Adding QM to SWS max is useful for breast cancer screening and SWS max alone is useful for breast cancer differentiation.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Adulto , Feminino , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Curva ROC , Ultrassonografia Mamária
20.
Sci Rep ; 7(1): 4899, 2017 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-28687736

RESUMO

To assess the association between BRAF V600E mutation and ultrasound (US) features in papillary thyroid carcinoma (PTC) patients with and without Hashimoto's thyroiditis (HT). We retrospectively reviewed the US features and status of BRAF V600E mutation in 438 consecutive patients with surgically confirmed PTCs. The association between BRAF mutation and US features were analyzed. In addition, we conducted subgroup analyses in terms of coexistent HT. The BRAF mutation was found in 86.5% of patients (379 of 438). Patient age (OR: 1.028, P = 0.010), age ≥ 50 y (OR: 1.904, P = 0.030), and microcalcification (OR: 2.262, P = 0.015) on US were significantly associated with BRAF mutation in PTC patients. Solid component (OR: 5.739, P = 0.019) on US was the significant predictor for BRAF mutation in patients with HT, while age (OR: 1.036, P = 0.017) and microcalcification (OR: 3.093, P = 0.017) were significantly associated with BRAF mutation in patients without HT. In conclusion, older age and microcalcification are risk factors for BRAF mutation in PTC patients, especially in those without HT. For those with HT, however, PTCs with BRAF mutation tend to be solid on ultrasound. These factors might be considered when making treatment planning or prognosis evaluation.


Assuntos
Doença de Hashimoto/genética , Mutação , Proteínas de Neoplasias/genética , Proteínas Proto-Oncogênicas B-raf/genética , Câncer Papilífero da Tireoide/genética , Neoplasias da Glândula Tireoide/genética , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/patologia , Feminino , Expressão Gênica , Doença de Hashimoto/diagnóstico por imagem , Doença de Hashimoto/patologia , Doença de Hashimoto/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/patologia , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA