Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38578440

RESUMO

INTRODUCTION: Revision shoulder arthroplasty can be challenging. One of the main considerations for surgeons is the type of implant that was placed in the initial surgery. Anatomic shoulder arthroplasty (ASA) is used for cases of osteoarthritis as well as for fractures of the humeral head. Hemiarthroplasty can be used for complex proximal humerus fractures. The purpose of this study is to determine whether there is a difference in clinical and radiographic outcomes between patients that failed primary fracture hemiarthroplasty (FHA), or ASA for osteoarthritis and then required reoperation with a conversion to reverse shoulder arthroplasty (RSA). METHODS: Patients with failed anatomic shoulder replacement, who had undergone conversion to RSA, were enrolled after a mean follow-up of 107 (85-157) months. Two different groups, one with failed ASA implanted for osteoarthritis and one with failed FHA, were created. At follow-up patients were assessed with standard radiographs and clinical outcome scores. RESULTS: Twenty-nine patients (f = 17, m = 12; 51%) suffered from a failed ASA (Group A), while the remaining 28 patients (f = 21, m = 74; 49%) had been revised due to a failed FHA (Group B). Patients of Group B had a poorer Constant score (Group A: 60 vs. Group B: 46; p = 0.02). Abduction (Group A: 115° vs. Group B: 89°; p = 0.02) was worse after conversion of a failed FHA to RSA in comparison to conversions of failed ASA. The mean bone loss of the lateral metaphysis was higher in patients with failed FHA (Group A: 5 mm vs. Group B: 20 mm; p = 0.0). CONCLUSION: The initial indication for anatomic shoulder arthroplasty influences the clinical and radiological outcome after conversion to RSA. Conversion of failed FHA to RSA is related to an increased metaphyseal bone loss, decreased range of motion and poorer clinical outcomes when compared to conversions of failed ASA implanted for osteoarthritis. LEVEL OF EVIDENCE: III Retrospective Cohort Comparison Study.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(10): 4566-4574, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37386197

RESUMO

PURPOSE: Recurrent anterior shoulder instability caused by critical bone loss of the glenoid is a challenging condition for shoulder surgeons. The purpose of this prospective multicenter trial was to compare the arthroscopic transfer of the coracoid process (Latarjet procedure) with the arthroscopic reconstruction of the glenoid using iliac crest autografts. METHODS: A prospective multi-center trial was performed in nine orthopaedic centres in Austria, Germany and Switzerland between July 2015 and August 2021. Patients were prospectively enrolled and received either an arthroscopic Latarjet procedure or an arthroscopic iliac crest graft transfer. Standardized follow-up after 6 months and mimimum 24 months included range of motion, Western Ontario stability index (WOSI), Rowe score and subjective shoulder value (SSV). All complications were recorded. RESULTS: 177 patients (group Latarjet procedure: n = 110, group iliac crest graft: n = 67) were included in the study. WOSI (n.s.), SSV (n.s.) and Rowe score (n.s.) showed no difference at final follow-up. 10 complications were seen in group Latarjet procedure and 5 in group iliac crest graft; the frequency of complications did not differ between the two groups (n.s.). CONCLUSION: The arthrosopic Latarjet procedure and arthroscopic iliac crest graft transfer lead to comparable results regarding clinical scores, frequency of recurrent dislocations and complication rates. LEVEL OF EVIDENCE: Level II.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Autoenxertos , Estudos Prospectivos , Ombro , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Ílio/transplante , Artroscopia/métodos , Recidiva
3.
Orthopadie (Heidelb) ; 52(5): 413-415, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-37010530

RESUMO

A 48-year-old male patient presented with inner skin retraction after a sports accident involving the knee. In a multi-ligament injury it must be assumed that knee dislocation has occurred. Inner skin retraction after knee distortion can result from an intra-articular dislocation of the ruptured medial collateral ligament. Prompt reduction and exclusion of concomitant neurovascular injuries is thus obligatory. After surgical reconstruction of the medial collateral ligament, instability was no longer apparent 3 months postoperatively.


Assuntos
Luxações Articulares , Luxação do Joelho , Traumatismos do Joelho , Lacerações , Traumatismo Múltiplo , Masculino , Humanos , Pessoa de Meia-Idade , Luxações Articulares/complicações , Luxação do Joelho/complicações , Articulação do Joelho/cirurgia , Traumatismos do Joelho/complicações , Ligamentos , Ruptura/complicações , Lacerações/complicações , Traumatismo Múltiplo/complicações
4.
Arch Orthop Trauma Surg ; 143(2): 959-965, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35344065

RESUMO

INTRODUCTION: Coracoid fractures after arthroscopic treatment of acromioclavicular (AC) joint separations lead to poor clinical outcomes. In this study, different configurations of bone tunnels in the lateral clavicle and coracoid were examined concerning the amount of stress induced in the coracoid. METHODS: An authentic 3D finite element model of an ac joint was established. Three 2.4 mm bone tunnels were inserted in the lateral clavicle, which were situated above, medially and laterally of the coracoid. Then, two 2.4 mm bone tunnels were inserted in the latter, each simulating a proximal and a distal suture button position. Von Mises stress analyses were performed to evaluate the amount of stress caused in the coracoid process by the different configurations. Then, a clinical series of radiographs was examined, the placement of the clavicle drill hole was analyzed and the number of dangerous configurations was recorded. RESULTS: The safest configuration was a proximal tunnel in the coracoid combined with a lateral bone tunnel in the clavicle, leading to an oblique traction at the coracoid. A distal bone tunnel in the coracoid and perpendicular traction as well as a proximal tunnel in the coracoid with medial traction caused the highest stresses. Anatomical placement of the clavicle drill hole does lead to configurations with smaller stresses. CONCLUSION: The bone tunnel placement with the smallest amount of shear stresses was found when the traction of the suture button was directed slightly lateral, towards the AC joint. Anatomical placement of the clavicle drill hole alone was not sufficient in preventing dangerous configurations. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Articulação Acromioclavicular , Fraturas Ósseas , Luxações Articulares , Procedimentos de Cirurgia Plástica , Humanos , Processo Coracoide/cirurgia , Análise de Elementos Finitos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/etiologia , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Clavícula/cirurgia , Ligamentos Articulares/cirurgia , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/etiologia , Luxações Articulares/cirurgia
5.
Arthrosc Tech ; 11(4): e497-e503, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35493056

RESUMO

The long head of the biceps is an important pain generator of the shoulder joint. Pathologies of the long head of the biceps involve superior labrum anterior to posterior lesions, pulley lesions, partial tears of the biceps tendon, biceps tendonitis, and medial biceps subluxation caused by full-thickness subscapularis tendon tears. Treatment of an inflamed or injured long head of the biceps by either tenotomy or tenodesis is often mandatory during shoulder arthroscopy to avoid persisting pain and possible revision procedures. In comparison with a tenotomy of the biceps tendon, a biceps tenodesis preserves the tension, anatomy, and cosmesis of the biceps muscle. The presented technique demonstrates a single portal technique for a proximal biceps tenodesis in the bicipital groove using an all-suture anchor.

6.
Arch Orthop Trauma Surg ; 142(12): 3817-3826, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34977963

RESUMO

INTRODUCTION: The employment of reverse shoulder arthroplasty for dislocated proximal humerus fractures of elderly patients becomes increasingly relevant. The standard inclination angle of the humeral component was 155°. Lately, there is a trend towards smaller inclination angles of 145° or 135°. Additionally, there has been an increased focus on the lateralization of the glenosphere. This retrospective comparative study evaluates clinical and radiological results of patients treated for proximal humerus fractures by reverse shoulder arthroplasty with different inclination angles of the humeral component, which was either 135° or 155°. Additionally, a different lateral offset of the glenosphere, which was either 0 mm or 4 mm, was used. METHODS: For this retrospective comparative analysis, 58 out of 66 patients treated by reverse total shoulder arthroplasty for proximal humerus fractures were included. The minimum follow-up was 24 months. Thirty (m = 3, f = 27; mean age 78 years; mean FU 35 months, range 24-58 months) were treated with a standard 155° humeral component and a glenosphere without lateral offset (group A), while 28 patients (m = 2, f = 26; mean age 79 years; mean FU 30 months, range 24-46 months) were treated with a 135° humeral component and a glenosphere with a 4 mm lateral offset (group B). We determined range of motion, Constant score, and the American Shoulder and Elbow Surgeons Shoulder score as clinical outcomes and evaluated tuberosity healing as well as scapula notching. RESULTS: Neither forward flexion (A = 128°, B = 121°; p = 0.710) nor abduction (A = 111°, B = 106°; p = 0.327) revealed differences between the groups. The mean Constant Score rated 63 in group A, while it was 61 in group B (p = 0.350). There were no differences of the ASES Score between the groups (A = 74, B = 72; p = 0.270). There was an increased risk for scapula notching in group A (47%) in comparison to group B (4%, p = 0.001). Healing of the greater tuberosity was achieved in 57% of group A and in 75% of group B (p = 0.142). The healing rate of the lesser tuberosity measured 33% in group A and 71% in group B (p = 0.004). CONCLUSIONS: Both inclination angles of the humeral component are feasible options for the treatment of proximal humerus fractures in elderly patients. Neither the inclination angle nor the lateral offset of the glenosphere seem to have a relevant influence on the clinical outcome. The healing rate of the lesser tuberosity was higher in implants with a decreased neck-shaft angle. There is an increased risk for scapula notching, if a higher inclination angle of the humeral component is chosen. LEVEL OF EVIDENCE: III. Retrospective comparative study.


Assuntos
Artroplastia do Ombro , Fraturas do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Fraturas do Ombro/cirurgia , Úmero/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
7.
Arch Orthop Trauma Surg ; 142(6): 1091-1098, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33931786

RESUMO

INTRODUCTION: The fixation of the coracoid process onto the glenoid is an important step of the Latarjet procedure, and implant-associated complications are a relevant and severe problem. This study compares the fixation strength and failure mode of two biodegradable materials with stainless-steel screws. METHODS: 24 Fresh-frozen cadaveric scapulae were divided into three groups of equal size and received a coracoid transfer. Cadavers were matched according to their bone mineral density (BMD). In group 1, small-fragment screws made of stainless steel were used. In the second group, magnesium screws were used, and in the third group, screws consisted of polylactic acid (PLLA). A continuously increasing sinusoidal cyclic compression force was applied until failure occurred, which was defined as graft displacement relative to its initial position of more than 5 mm. RESULTS: At 5-mm displacement, the axial force values showed a mean of 374 ± 92 N (range 219-479 N) in group 1 (steel). The force values in group 2 (magnesium) had a mean of 299 ± 57 N (range 190-357 N). In group 3 (PLLA), failure occurred at 231 ± 83 N (range 109-355 N). The difference between group 1 (steel) and group 2 (magnesium) was not statistically significant (P = 0.212), while the difference between group 1 (steel) and group 3 (PLLA) was significant (P = 0.005). CONCLUSION: Stainless-Steel screws showed the highest stability. However, all three screw types showed axial force values of more than 200 N. Stainless steel screws and PLLA screws showed screw cut-out as the most common failure mode, while magnesium screws showed screw breakage in the majority of cases. EVIDENCE: Controlled laboratory study.


Assuntos
Magnésio , Articulação do Ombro , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Poliésteres , Articulação do Ombro/cirurgia , Aço Inoxidável , Aço
8.
J Ultrasound Med ; 41(2): 409-415, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33955022

RESUMO

OBJECTIVE: Dynamic horizontal instability is considered to be the main reason for poor outcome after treatment for acromioclavicular (AC) joint instability. In this study, we describe a simple technique to quantify this pathology via sonography. METHODS: Thirty-six shoulders from 18 patients with ac joint instabilities were examined using modified Alexander views and a standardized sonographic examination. On the Alexander views, overlap of acromion and clavicle (OLAC), glenoid center to posterior clavicle distance (GCPC), and lateral extension (LE) were measured. Afterwards, the results were analyzed and compared with sonography. Posterior translation of the clavicle and the difference of translation between healthy and injured shoulder were evaluated. RESULTS: The mean age of the patients was 39 ± 14 years (range 19-61 years). We included 4 (22%) Rockwood type 3, 1 (6%) Rockwood type 4, and 13 (72%) Rockwood type 5 lesions. Four (22%) patients were female and 14 (78%) male patients. Posterior clavicle translation of the injured shoulder correlated strongly between OLAC and sonography (r = -0.514, P = .029), and the difference of translation between healthy and injured shoulder correlated very strongly between LE and sonography (r = 0.737, P < .001). CONCLUSION: The sonographic measurement technique for horizontal instability presented in this work could help detect horizontal instabilities. While the observation of dynamic horizontal displacement is a strength of this technique, measurements are hindered in cases of high coracoclavicular distances. LEVEL OF EVIDENCE: Level III-retrospective cohort study.


Assuntos
Articulação Acromioclavicular , Instabilidade Articular , Articulação Acromioclavicular/diagnóstico por imagem , Adulto , Clavícula/diagnóstico por imagem , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia , Adulto Jovem
9.
Eur J Orthop Surg Traumatol ; 32(2): 307-315, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33880654

RESUMO

PURPOSE: Reverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155° and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135° in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. MATERIAL AND METHODS: For this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m = 11, f = 10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155° humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m = 5, f = 16; mean age 72 years; mean follow-up 34 months) were treated with a 135° humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. RESULTS: The clinical results were similar in both groups concerning the Constant Score (group A = 56.3 vs. group B = 56.1; p = 0.733), the adjusted CS (group A = 70.4% vs. group B = 68.3%; p = 0.589) and the SSV (group A = 72.0% vs. group B = 75.2%; p = 0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction = 98° versus 97.9°, p = 0.655; external rotation with the arm at side = 17.9° versus 18.7°, p = 0.703; external rotation with the arm positioned in 90° of abduction = 22.3° versus 24.7°, p = 0.524; forward flexion = 116.1° versus 116.7°, p = 0.760. The rate of scapular notching was higher (p = 0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A = 48% vs. group B = 38%). CONCLUSION: Theoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155° and a standard glenosphere, implants with a humeral inclination angle of 135° and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Artroplastia do Ombro , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Prótese de Ombro , Idoso , Humanos , Úmero/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos , Artropatia de Ruptura do Manguito Rotador/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
10.
JSES Int ; 5(3): 342-345, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33723537

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has impeded the treatment of elective shoulder patients all over the world. Owing to the constraints in personnel and operation theater capacities, many patients who should undergo planned surgeries could not receive medical care. In our study, we examined the status quo of elective shoulder arthroscopy during the pandemic in Germany. METHODS: Using a nonprofit database, 40 shoulder units that performed the most arthroscopic rotator cuff repairs in Germany in 2018 were identified. Following a standardized protocol, the web pages of these units were screened, and their strategy for elective procedures during the COVID-19 pandemic was analyzed. Special emphasis was put on the use of new digital technologies. RESULTS: At the time of the study, no unit had stopped scheduling appointments for elective shoulder patients because of the pandemic. Almost all units (97.5%) offered explicit information about COVID-19 and their strategies toward it. The possibilities of visiting patients in shoulder units varied owing to local restrictions. Two units (5%) offered digital consultations. CONCLUSION: At the time of the study, elective shoulder procedures could be planned and carried out at the largest centers in Germany. Local restrictions had a great influence on the organization of the procedure and hospital stay during the COVID-19 pandemic. Digital consultations were not available in every unit.

11.
Orthop Surg ; 13(1): 77-82, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33258229

RESUMO

OBJECTIVE: In this study, we hypothesized that standing and supine X-rays lead to different preoperative planning results. METHODS: The present study included 168 pictures from 81 patients who were treated surgically with high tibial osteotomy (HTO) for varus deformity between January 2017 and February 2018. Each patient underwent whole leg X-ray examinations in both standing and supine position. On both images, the following parameters were measured: degree of axis deviation (DAD), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), width of medial (MJS) and lateral joint space (LJS), and the correction angle (CA). The results were correlated with the patients' age and body mass index (BMI). To analyze intra-observer reliability, the same researcher, blinded to the previous measurements, remeasured all X-rays from 10 patients 8 weeks after the initial measurements were carried out. RESULTS: While mLDFA (P = 0.075), mMPTA (P = 0.435), and MJS (P = 0.119) did not show any differences between the two modalities, LJS (P = 0.016) and DAD (P < 0.001) differed significantly, leading to different correction angles (P < 0.001). The mean difference of the CA was 1.7° ± 2.2° (range, -2.6° to-15.4°). In 14 legs (17%), the standing X-ray led to a correction angle that was at least 3° larger than the calculation revealed in the supine X-ray; in 4 legs (5%), it was at least 5° larger. Increased BMI (r = 0.191, P = 0.088) and older age (r = 0.057 , P = 0.605) did not show relevant correlation with DAD differences. However, more severe varus malalignment in the supine radiograph did correlate moderately with differences of correction angles between supine and weight-bearing radiographs (r = 0.414, P < 0.001). The analysis of the intra-rater reliability revealed mediocre to excellent intercorrelation coefficients between the measurements of the observer. CONCLUSION: The use of supine and standing X-ray images leads to different planning results when performing high tibial osteotomies for varus gonarthrosis. To avoid potential overcorrection, surgeons might consider increased lateral joint spaces on standing radiographs in osteoarthritic knees with varus deviation.


Assuntos
Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Radiografia , Postura Sentada , Posição Ortostática , Suporte de Carga , Feminino , Humanos , Masculino , Planejamento de Assistência ao Paciente , Período Pré-Operatório , Reprodutibilidade dos Testes
12.
BMC Musculoskelet Disord ; 21(1): 226, 2020 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-32278344

RESUMO

BACKGROUND: Implant anchorage in highly osteoporotic bone is challenging, since it often leads to osteosynthesis failure in geriatric patients with supracondylar femoral fractures. Cementation of screws is presumed to prevent such osteosynthesis failure. This study aimed to investigate the effect of a newly designed, cementable fenestrated condylar screw for plate fixation in a biomechanical setting. METHODS: Eight pairs of osteoporotic cadaver femora with an average age of 77 years, ranging between 62 and 88 years, were randomly assigned to either an augmented or a non-augmented group. In both groups an instable 33-A3 fracture according to the AO / OTA classification was fixed with an angular stable locking plate. All right samples received a cement augmentation of their fenestrated condylar screws with calcium phosphate bone cement (CPC). Mechanical testing was performed at a load to failure mode by cyclic axial loading, using a servohydraulic testing machine. RESULTS: With a mean of 2475 N (95% CI: 1727-3223 N), the pressure forces resulting in osteosynthesis failure were significantly higher in specimen with cemented condylar screws as compared to non-cemented samples (1875 N (95% CI: 1320-2430 N)) (p = 0.024). In both groups the deformation of the constructs, with the distal screws cutting through the condylar bone, were the most frequent cause for failure. Analysis of axial stiffness (p = 0.889) and irreversible deformity of the specimens revealed no differences between the both groups (p = 0.161). No cement leakage through the joint line or the medial cortex was observed. CONCLUSION: Based on the present study results, the newly introduced, cementable condylar screw could be an encouraging feature for the fixation of supracondylar femoral fractures in patients with reduced bone quality in terms of load to failure accuracy of the cement application.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas por Osteoporose/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cimentos Ósseos , Placas Ósseas , Parafusos Ósseos , Cadáver , Feminino , Fraturas do Fêmur/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/patologia
13.
J Shoulder Elbow Surg ; 29(7): 1479-1483, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32197807

RESUMO

BACKGROUND: This study presents a new technique for assembling an all-suture anchor from existing medical products. The biomechanical characteristics of this self-made anchor (SMA) are compared with those of an industrially manufactured all-suture anchor. METHODS: The SMAs were made from established medical products (FiberWire #2 and 2-mm FiberTape; Arthrex, Naples, FL, USA). Pretesting was performed in biphasic polyurethane foam blocks. In the next step, 10 SMAs and 10 industrially made anchors (IMAs; 1.8-mm double-loaded Y-Knot Flex all-suture anchor; ConMed Linvatec, Largo, FL, USA) were applied with an insertion tool and tested in fresh porcine femora using a servohydraulic testing system, with a preload of 10 N and a displacement rate of 12.5 mm/s. Pullout strength and failure mode were recorded. RESULTS: The mean load at failure in the foam blocks was 459 ± 124 N in the SMA group and 538 ± 83 N in the IMA group. In porcine bone, failure occurred at 461 ± 102 N in the SMA group and 431 ± 135 N in the IMA group. The differences in pullout strength between the 2 types of anchor were not statistically significant, either in the foam blocks (P = .17) or in porcine bone (P = .62). CONCLUSION: A handmade all-suture anchor using 2 high-strength sutures woven into a 2-mm strip of high-strength tape did not show statistically different failure loads in polyurethane foam or in porcine metaphyseal bone in comparison with a commercially produced double-loaded all-suture anchor. The principal mode of failure in porcine bone in both groups was anchor pullout.


Assuntos
Fêmur/cirurgia , Procedimentos Ortopédicos/instrumentação , Âncoras de Sutura , Suturas , Animais , Fenômenos Biomecânicos , Teste de Materiais , Modelos Anatômicos , Modelos Animais , Poliuretanos , Técnicas de Sutura , Suínos , Resistência à Tração
15.
Arch Orthop Trauma Surg ; 139(10): 1417-1424, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31321497

RESUMO

AIM: The subscapularis muscle is an important active stabilizer of the glenohumeral joint. For this radiological study, we investigated if its radiological integrity is affected after arthroscopic glenoid reconstruction. In the technique used, an autologous iliac crest graft is transported through the rotator interval, and the graft is fixed via an antero-inferior portal with compression screws. METHODS: 3 women and 6 men (mean age 31 ± 9 years, min 21, max 46 years) who had a preoperative glenoid deficit of 23% ± 6% (min 13%, max 29%) were included. In a follow-up after an interval of 34 months (min 19, max 50), MRI scans were performed on both shoulders. With ITK-SNAP, a 3D reconstruction software, the volume of the subscapularis muscle in the injured and contralateral shoulder was measured. In addition, signal intensity ratios (PSI) (infraspinatus muscle / cranial subscapularis muscle and infraspinatus muscle / caudal subscapularis muscle) were analyzed and the width of the cranial and caudal portions as well as the length of the subscapularis muscle in the parasagittal plane were determined. RESULTS: The 3D volume showed no difference between operated and healthy shoulders (p = 0.07), neither did PSI ratios (infraspinatus muscle / cranial subscapularis muscle: p = 1.00, infraspinatus muscle / caudal subscapularis muscle: p = 1.00). In the parasagittal plane, length (p = 0.09) and cranial width (p = 0.23) did not differ. However, the width of the lower muscle was increased in injured shoulders (p = 0.02). CONCLUSION: In this cohort, no relevant volume loss could be found after arthroscopic glenoid reconstruction. However, a greater width of the lower muscle portion could be identified in the parasagittal plane as a possible indication of scarring.


Assuntos
Artroscopia/métodos , Transplante Ósseo/métodos , Ílio/transplante , Músculo Esquelético/fisiopatologia , Manguito Rotador/cirurgia , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adulto , Autoenxertos , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Luxação do Ombro/fisiopatologia , Adulto Jovem
16.
Orthop Traumatol Surg Res ; 105(2): 317-322, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30635230

RESUMO

INTRODUCTION: The optimal treatment of isolated fractures of the greater tuberosity is an important topic of current surgical research. While non-displaced fractures are amenable to conservative treatment, displacement of the fragment can result in rotator cuff malfunction and impingement. For the present study, risk factors predicting secondary fragment displacement were analyzed. HYPOTHESIS: Certain risk factors determine a higher risk of secondary displacement in patients with greater tuberosity fractures. PATIENTS AND METHODS: All patients diagnosed with a fracture of the greater tuberosity and initially treated non-surgically at our Level I trauma center between January 2008 and July 2015 were included in this retrospective analysis. Patients were grouped into: no secondary displacement (group 1) and secondary displacement at follow-up (group 2). The following risk factors were analyzed: age, gender, side of fracture, initial displacement, fragment/head ratio, fragment shape, dislocation, concomitant fractures and concomitant fractures to the same extremity. RESULTS: 82 patients (42 male, 40 female) were eligible for further analyses. Median follow-up was 8.0±39.5 days. Patients with secondary displacement (group 2) were significantly older (group 1: 51.7±15.5, group 2: 68.3±14.3; p<0.001) and had significantly more shoulder dislocations (p=0.024), whereas gender (p=0.299), side of fracture (p=0.189) and fragment/head ratio (p=0.660) showed no significant different distribution between both groups. Finally, split-type fractures increased the risk of secondary displacement. DISCUSSION: The present study identified age older than 65 years to be an important risk factor for secondary displacement in the conservative management of fractures of the greater tuberosity. Furthermore, fracture type and shoulder dislocations are factors associated with an increased relative risk for secondary displacement. LEVEL OF PROOF: III, Retrospective comparative study.


Assuntos
Tratamento Conservador/métodos , Luxação do Ombro/terapia , Fraturas do Ombro/complicações , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Fatores de Risco , Luxação do Ombro/diagnóstico , Luxação do Ombro/etiologia , Fraturas do Ombro/diagnóstico , Fraturas do Ombro/terapia , Fatores de Tempo
17.
J Shoulder Elbow Surg ; 28(1): 158-163, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30054243

RESUMO

BACKGROUND: Arthroscopic glenoid reconstruction using autografts is an advanced procedure that requires experience and preparation. Knowledge about anatomic pitfalls is therefore important to establish well-positioned portals and prevent neurovascular damage. METHODS: We included 43 computed tomography scans from 43 patients. The distance between the tip of the coracoid process and a perpendicular line representing the anteroinferior glenoid was measured. From these results an anteroinferior working portal was designed, and the angulation needed for screw insertion to fixate a hypothetical graft was measured. In a second step, 9 patients underwent magnetic resonance imaging scans 34 ± 10 months after glenoid reconstruction, and the distance between the screw approach path and the neurovascular bundle was measured. RESULTS: In the analyzed scans, average defect size was 23%, and the coracoid process to the anteroinferior glenoid distance was 32 ± 7 mm. We thus hypothesized that a corridor 20 to 30 mm inferior to the coracoid process would be the ideal position for a working portal. Through this portal, 85% of screws could be applied with 0° to 30° angulation. When the postoperative scans were analyzed, the distance from the neurovascular bundle showed an average of 26 ± 6 mm for the superior screw and 21 ± 5 mm for the inferior screw. CONCLUSIONS: The ideal distance between the coracoid process and an anteroinferior working portal is 32 mm. Having established the portal, instruments should not be inserted pointing in a medial direction of the coracoid process due to the proximity of the neurovascular bundle.


Assuntos
Artroscopia , Processo Coracoide/anatomia & histologia , Ílio/transplante , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/cirurgia , Adulto , Autoenxertos , Parafusos Ósseos , Estudos de Coortes , Processo Coracoide/diagnóstico por imagem , Feminino , Humanos , Complicações Intraoperatórias/prevenção & controle , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Orthop Traumatol Surg Res ; 105(2): 219-223, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30581129

RESUMO

INTRODUCTION: Cuff tear arthritis and complex proximal humeral fractures are common pathologies that are frequently addressed by the implantation of a reversed shoulder prosthesis. The present cadaveric study aimed to analyze the effect of cement augmentation of the glenoid component on the primary stability in geriatric patients. HYPOTHESIS: Cement augmentation of glenoid baseplate screws has an influence on primary stability in reversed shoulder arthroplasty (RSA). MATERIALS AND METHODS: Glenoid base plates (Delta Xtend, DePuy Synthes, Westchester, USA) were implanted in 6 pairs of formalin-fixated scapulae of 4 female and 2 male donors (average age 83 years). Two angle stable screws were placed at the superior and inferior position. Cement augmentation was performed with 2ml bone cement (Kyphon, Medtronic, Minneapolis, USA) per screw in right specimens. Afterwards, biomechanical testing with 600 to 1000N (100 cycles) at a 65° abduction angle was performed. Finally, a load-to-failure analysis was conducted. RESULTS: No implant loosening was observed during cyclic tests from 600N to 1000N. In addition no difference in the plastic deformation was detected at 600N (p=0.301), 700N (p=0.522), 800N (p=0.480), 900N (p=0.521) and 1000N (p=0.748). Load-to-failure analyses revealed implant loosening at 3314N (SD 823N) in the cement-augmented implants and at 3059N (SD 974N) in scapulae with non-cemented screws (p=0.522). DISCUSSION: Cement-augmented fixation of the glenoid component did not result in an increased primary stability in this study. Thus, the application of cement should be critically assessed considering associated risks and increased costs. LEVEL OF PROOF: Basic science study, controlled laboratory study.


Assuntos
Artroplastia do Ombro/métodos , Cimentos Ósseos , Parafusos Ósseos , Escápula/cirurgia , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Prótese Articular , Masculino , Articulação do Ombro/diagnóstico por imagem
19.
Arch Orthop Trauma Surg ; 138(11): 1557-1562, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29948225

RESUMO

INTRODUCTION: Glenoid bone loss in recurrent anterior instability of the shoulder needs to be addressed to restore joint stability. Over the last years, several arthroscopic methods have been described to treat this condition. However, no clinical mid-term results have been presented for arthroscopic iliac crest bone grafting procedures. METHODS: We included 32 patients with significant glenoid bone loss and repetitive dislocations of the shoulder who were treated in our shoulder unit with a previously described all-arthroscopic reconstruction technique. All patients filled out a questionnaire evaluating repetitive dislocations, consumption of pain medicine, Constant Score (CS, adapted to age and gender), activities of daily living (ADL), visual analogue scale for pain (VAS) as well as the Western Ontario Shoulder Instability Index (WOSI). Additionally, all complications were recorded. RESULTS: After a mean follow-up of 42 months, three traumatic dislocations had been observed. With an ADL of 25 points (95% CI 24-27), a WOSI of 71% (95% CI 65-76) and CS of 87 points (95% CI 82-92), our patients showed good functional results. The VAS result for pain was 2.1 (95% CI 1.5-2.6). No patient reported the regular usage of pain medicine related to the shoulder instability at final follow-up. CONCLUSION: The all-arthroscopic glenoid reconstruction using iliac crest grafts shows good functional results with a recurrence rate of 9%. At final follow-up 42 months after surgery, our patients showed low pain levels and acceptable complications.


Assuntos
Artroscopia/métodos , Transplante Ósseo/métodos , Procedimentos de Cirurgia Plástica/métodos , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Atividades Cotidianas , Adulto , Artroscopia/efeitos adversos , Transplante Ósseo/efeitos adversos , Feminino , Seguimentos , Humanos , Ílio/transplante , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Complicações Pós-Operatórias/epidemiologia , Procedimentos de Cirurgia Plástica/efeitos adversos , Recidiva , Escápula/cirurgia , Resultado do Tratamento , Adulto Jovem
20.
Knee Surg Sports Traumatol Arthrosc ; 26(1): 299-305, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29063152

RESUMO

PURPOSE: Recurrent anterior instability of the glenohumeral joint is a demanding condition, especially in cases of glenoid bone loss. Various treatment options have been described, such as arthroscopic grafting techniques and the Latarjet procedure. In this study, the degree to which an arthroscopically applied iliac crest graft restores the glenoid anatomy was evalutated. METHODS: Nine patients (three women and six men) with an average age of 31 ± 9 years (21-46 years) who were treated with an arthroscopic iliac crest graft technique were included in this study. After a mean follow up of 34 ± 10 months (19-50 months) after the procedure, MRI scans of both shoulders were performed and the glenoid width, Glenoid Index (GI), Pixel Signal intensity (PSI), thickness of the tissue covering the articular aspect of the graft, inclination, version, concavity and balance stability angle were measured. RESULTS: All scans showed the cultivation of tissue on the graft, which visually resembled the cartilage of the native ipsilateral glenoid. Additionally, reshaping of the graft to repair the glenoid configuration could be observed. Glenoid width (p = 0.022) and GI (p < 0.001) increased significantly through surgery. The tissue examined on the graft showed a significant pixel intensity gap (p = 0.017) but comparable thickness (n.s.) in relation to native cartilage. The remaining parameters did not differ significantly between both shoulders. CONCLUSION: In the cohort presented, iliac crest grafts were able to restore the glenoid configuration, and the glenoid was re-shaped to its native contour. Additionally, cartilage-like scar tissue with similar thickness as healthy cartilage was formed on the articular side of the graft. These results suggest that glenoid reconstruction is not only important for prevention of recurrence, but also for restoration of the native glenoid anatomy. LEVEL OF EVIDENCE: Level III-retrospective cohort study.


Assuntos
Artroscopia/métodos , Transplante Ósseo/métodos , Cavidade Glenoide/cirurgia , Ílio/transplante , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Adulto , Feminino , Seguimentos , Cavidade Glenoide/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA