Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Neurol Res Pract ; 5(1): 13, 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37020243

RESUMO

BACKGROUND: Infective endocarditis (IE) is a serious condition with a high mortality, represents a rare cause of stroke and an increased risk of intracranial hemorrhage. In this single center study, we characterize stroke patients with IE. We were interested in risk factors for intracranial hemorrhage and outcome of patients with intracranial hemorrhage compared to patients with ischemic stroke. METHODS: Patients with IE and symptomatic ischemic stroke or intracranial hemorrhage admitted to our hospital between January 2019 and December 2022 were included in this retrospective study. RESULTS: 48 patients with IE and ischemic stroke or intracranial hemorrhage were identified. 37 patients were diagnosed with ischemic stroke, 11 patients were diagnosed with intracranial hemorrhage. The intracranial hemorrhage occurred within the first 12 days after admission. We identified Staphylococcus aureus detection and thrombocytopenia as risk factors for hemorrhagic complications. An increased in-hospital mortality in patients with intracranial hemorrhage (63.6% vs. 22%, p = 0.022) was found, whereas patients with ischemic stroke and patients with intracranial hemorrhage do not differ regarding favorable clinical outcome (27% vs. 27.3%, p = 1.0). 27.3% patients with intracranial hemorrhage and 43.2% patients with ischemic stroke underwent cardiac surgery. Overall, 15.7% new ischemic strokes occurred after valve reconstruction, whereas no new intracranial hemorrhage was observed. CONCLUSIONS: We found an increased in-hospital mortality in patients with intracranial hemorrhage. Beside thrombocytopenia, we identified S. aureus detection as a risk factor for intracranial hemorrhage.

2.
Phys Med Biol ; 61(22): 7848-7863, 2016 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-27779127

RESUMO

Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D-2D orthogonal planes (sagittal-coronal, temporal resolution 200-252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was ⩽ 3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D-2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy system could potentially enable completely non-invasive treatment of AF.


Assuntos
Algoritmos , Fibrilação Atrial/cirurgia , Coração/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Radiocirurgia/métodos , Humanos , Masculino , Movimento (Física) , Contração Miocárdica , Respiração , Estudos Retrospectivos
3.
Med Phys ; 41(12): 120702, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25471947

RESUMO

PURPOSE: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. METHODS: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. RESULTS: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior-inferior), 2.4 mm (anterior-posterior), and 2 mm (left-right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the ideal scenario, compromising either normal tissue dose constraints or PTV coverage. The magnetic field caused a slight increase in the PTV dose with the in-line MRI-Linac configuration. CONCLUSIONS: The authors' results indicate that real-time tracking and motion compensation are mandatory for cardiac radiosurgery and MRI-guidance is feasible, opening the possibility of treating cardiac arrhythmia patients completely noninvasively.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Simulação por Computador , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Campos Magnéticos , Masculino , Método de Monte Carlo , Movimento (Física) , Miocárdio/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Respiração , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Praxis (Bern 1994) ; 100(22): 1353-60, 2011 Nov 02.
Artigo em Alemão | MEDLINE | ID: mdl-22048911

RESUMO

Resistant hypertension is defined as blood pressure that remains above therapeutic goal despite the use of 3 antihypertensive drugs including a diuretic. After exclusion of secondary causes and medical in compliance, the estimated prevalence of resistant arterial hypertension ranges from 4% to 19% in hypertensive patients. Treatment requires a multimodal therapeutic approach. Hyperactivation of the sympathetic nervous system plays a key role in the genesis of hypertension. Targeting renal sympathetic nerves, percutaneous catheter-based renal denervation is a new therapeutic option for the treatment of resistant arterial hypertension in selected drug resistant patients.


Assuntos
Ablação por Cateter/métodos , Hipertensão/cirurgia , Rim/inervação , Artéria Renal/inervação , Simpatectomia/métodos , Anti-Hipertensivos/uso terapêutico , Resistência a Medicamentos , Quimioterapia Combinada , Vias Eferentes/cirurgia , Humanos
6.
Herzschrittmacherther Elektrophysiol ; 20(3): 121-30, 2009 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-19727897

RESUMO

Cardiac resynchronization therapy (CRT) can result in significant clinical improvement in patients with congestive heart failure. Non-response to CRT might be attributable to suboptimal programming. Follow-up has to ensure effective left ventricular (LV) stimulation at rest and also sufficient exercise-dependent atrial rates. Rate adaptive pacing is required in case of chronotropic incompetence. Specific algorithms may help to restore biventricular pacing or the enhance biventricular pacing rate when intrinsic AV conduction occurs, e.g., during intermittent atrial fibrillation. An individual adaptation of the AV interval is essential to achieve maximal benefit from resynchronization. Optimized AV interval programming synchronizes atrial and ventricular contraction, maximizing the atrial contribution to LV diastolic filling and preventing presystolic mitral regurgitation. Interventricular synchrony and LV contraction might be further harmonized by VV interval adaptation, although the impact of VV optimization on CRT outcome is still under debate. Non-invasive methods of AV and VV interval optimization by electro- and echocardiography are discussed.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/prevenção & controle , Terapia Assistida por Computador/métodos , Terapia Assistida por Computador/tendências , Alemanha , Humanos
7.
Physiol Behav ; 98(5): 563-9, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-19751751

RESUMO

Obesity is an increasing socio-economic health problem. Diet-induced obese (DIO) rodents are widely used as a model of obesity in humans. However, there is no comprehensive data about the behavioral phenotype of DIO rodents. Therefore, the aim of the present study was to determine whether a high-fat-diet changes behavioral patterns of DIO Fischer 344 (F344) rats in comparison with lean littermates. The behavioral tests (homecage, holeboard, social interaction, and hotplate) were performed in 28 normal-weight and 28 male DIO F344 rats (mean age: 16 weeks) and revealed a significantly higher level of anxiety- and aggression-related parameters in obese rats, whereas their pain threshold was significantly lower. Fitting to a different behavioral response, basal corticosterone levels (measured by RIA) of obese animals were significantly elevated (16.0ng/ml vs. 12.5ng/ml; p<0.01). We conclude that obese rats differ in various aspects from their lean littermates. The altered behavioral characteristics displayed by DIO F344 rats have to be considered in further experiments involving DIO rodents.


Assuntos
Corticosterona/sangue , Dieta/efeitos adversos , Obesidade/sangue , Obesidade/etiologia , Agressão/fisiologia , Análise de Variância , Animais , Ansiedade/etiologia , Peso Corporal/fisiologia , Modelos Animais de Doenças , Inteligência Emocional , Comportamento Exploratório , Temperatura Alta/efeitos adversos , Masculino , Obesidade/complicações , Limiar da Dor/fisiologia , Estimulação Física/métodos , Ratos , Ratos Endogâmicos F344
8.
Heart ; 91(4): 500-6, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15772212

RESUMO

OBJECTIVE: To determine how short and long term complication rates after pacemaker implantation are influenced by patient morbidity, operator experience, and choice of pacing system. DESIGN: Retrospective analysis of 1884 patients who received VVI (n = 610), VDD (n = 371), or DDD devices (n = 903) between 1990 and 2001. Follow up period was 64 (34) months. The influence of age, sex, coronary artery disease, myocardial infarction, reduced left ventricular (LV) function, right ventricular (RV) dilatation, atrial fibrillation, device type, and operator experience on operation time and complication rate were analysed. RESULTS: Operation time was prolonged in patients with coronary artery disease, inferior myocardial infarction, reduced LV function, and RV dilatation. Implantation of DDD pacemakers prolonged operation time, particularly among operators with a low or medium level of experience. The overall complication rate was 4.5%. Sixty seven per cent of these complications occurred within the first three months. Complication rate was increased by age, reduced LV function, and RV dilatation. Implantation of DDD systems led to a higher complication rate (6.3%) than implantation of VVI (2.6%) or VDD pacemakers (3.2%). These differences were present only among operators with a low or medium level of experience. CONCLUSIONS: Operation time and complication rate increased with age, impaired LV function, and RV dilatation. Complication rates were higher with DDD than with VVI or VDD implantation and were excessive among inexperienced but not experienced operators.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Competência Clínica , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Fluoroscopia , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/complicações
9.
Contraception ; 70(4): 269-75, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15451329

RESUMO

DMPA-SC 104 mg/0.65 mL is a new, low-dose subcutaneous (SC) formulation of Depo-Provera contraceptive injection (150 mg/mL medroxyprogesterone acetate injectable suspension) that provides efficacy, safety and immediacy of onset equivalent to Depo-Provera intramuscular (IM) injection. Two large, open-label, Phase 3 studies assessed the 1-year contraceptive efficacy, safety and patient satisfaction with DMPA-SC administered every 3 months (12-13 weeks). Zero pregnancies were reported in both studies, which included a total of 16,023 woman-cycles of exposure to DMPA-SC and substantial numbers of overweight or obese women. DMPA-SC was well-tolerated and adverse events were similar to those reported previously with Depo-Provera IM. Thus, DMPA-SC offers women a new, highly effective and convenient long-acting contraceptive option.


Assuntos
Anticoncepcionais Femininos/administração & dosagem , Anticoncepcionais Femininos/efeitos adversos , Acetato de Medroxiprogesterona/administração & dosagem , Acetato de Medroxiprogesterona/efeitos adversos , Adulto , Amenorreia/epidemiologia , Ásia , Pressão Sanguínea , Índice de Massa Corporal , Peso Corporal , Europa (Continente) , Feminino , Humanos , Injeções Subcutâneas , Satisfação do Paciente , Gravidez , Estados Unidos , Hemorragia Uterina/epidemiologia
10.
J Am Coll Cardiol ; 37(3): 920-5, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11693771

RESUMO

OBJECTIVES: The goal of this study was to determine the relationship between repolarization and excitability in the human atrium under various conditions. BACKGROUND: Action potential duration (APD) measurements from monophasic action potential (MAP) recordings provide a surrogate for measuring the effective refractory period (ERP) in human ventricle. The relationship between repolarization and refractoriness in human atrium and the effect of prior atrial fibrillation/flutter on the ERP/APD correlation are unknown. METHODS: Seven patients with sinus rhythm and 15 patients after conversion of atrial flutter or fibrillation were evaluated. Monophasic action potentials were recorded at multiple right atrial sites and during different basic cycle lengths from 300 to 700 ms, while ERPs were determined by extrastimulus technique using the MAP recording-pacing combination catheter. RESULTS: There was a close correlation between ERP and APD at 70% repolarization (APD70, r = 0.97; p < 0.001) and 90% repolarization (APD90, r = 0.98; p < 0.001), respectively. Refractoriness occurred at a repolarization level of 72 +/- 8%. The ERP/APD70 and ERP/APD90 ratios averaged 1.06 +/- 0.10 and 0.86 +/- 0.08, respectively. These ratios were nearly constant over the entire range of basic cycle lengths, between different sites in individual patients and between different patients. Patients cardioverted from atrial fibrillation or flutter exhibited no significant differences in the ERP/APD relationship compared with patients with sinus rhythm. CONCLUSIONS: Effective refractory period and APD are closely related in the human right atrium. Using the MAP recording technique, atrial ERPs can be assessed by measurement of APDs. Effective refractory period is most closely reflected by APD70. Thus, MAP recordings allow investigation of the local activation and repolarization time course beat by beat, visualizing the excitable gap.


Assuntos
Arritmias Cardíacas/fisiopatologia , Função Atrial , Sistema de Condução Cardíaco/fisiologia , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia
11.
Pacing Clin Electrophysiol ; 24(9 Pt 1): 1383-8, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11584461

RESUMO

Unipolar ventricular leads were implanted in a considerable percentage of pacemaker recipients. There is little information on incidence and risk factors for unipolar pacemaker dysfunction using modern lead designs. Included in a cross-sectional analysis were 682 patients who fulfilled the following criteria: chronically implanted bipolar ventricular leads (> 1 year), intraoperative stimulation threshold < 1.0 V/0.5 ms, and potential amplitude > 6 mV. Incidences of chest wall stimulation (CWS) at an output of twice the amplitude threshold and of myopotential oversensing (MPO) at a sensitivity of half the sensing threshold were assessed. Energy (0.60 [0.72] vs 0.63 [0.81] microJ) and sensing thresholds (8.31 [3.18] mV vs 8.47 [3.47] mV) did not differ between uni- and bipolar modes. While all pacemakers worked properly during bipolar configuration, malfunctions were observed in 5.9% of patients during unipolar configuration (CWS = 1.9%, MPO = 4.2%). Patient age > 76 years (hazard ratio HR 8.2; P < 0.001), heart failure > or = NYHA Class II (HR 3.8; P < 0.001), and an antiarrhythmic therapy with Class I or III drugs (HR 3.3; P = 0.002) were independently associated with the occurrence of unipolar pacemaker dysfunction. Use of steroid-eluting leads reduced the probability of pacemaker dysfunction (HR 0.45; P = 0.03). Risk factors for unipolar ventricular pacemaker malfunction were higher age, heart failure, and antiarrhythmic drug therapy. Particularly in these patients, use of bipolar ventricular leads is beneficial.


Assuntos
Eletrocardiografia , Eletrodos Implantados , Análise de Falha de Equipamento , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Processamento de Sinais Assistido por Computador , Software
12.
Pacing Clin Electrophysiol ; 24(8 Pt 1): 1286-8, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11523617

RESUMO

This case report describes a patient with complete AV block and a VDD pacemaker who experienced repetitive episodes of symptomatic bradycardia. Episodes occurred due to activation of an automatic beat-to-beat mode switch algorithm. After mode switch to VDI operation, the pacemaker failed to immediately switch back to AV synchronous pacing when regular sinus rhythm (> or = 100 beats per minute) resumed despite adequate P wave sensing. Dizziness was felt for up to several minutes of asynchronous pacing at the lower rate limit until VDD mode was restored. Episodes were completely eliminated by programming the mode switch function from an automatic beat-to-beat algorithm to a fixed rate algorithm.


Assuntos
Bradicardia/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Bloqueio Cardíaco/terapia , Marca-Passo Artificial , Algoritmos , Estimulação Cardíaca Artificial/métodos , Falha de Equipamento , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
13.
Clin Neuropathol ; 20(2): 80-6, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11327302

RESUMO

Giant cell arteritis (GCA) is a disease chiefly found in elderly patients. Intracranial vessels are rarely involved in GCA. Here we report the case of a 19-year-old woman with GCA in the basilar and vertebral arteries. Two weeks after the first symptoms, she developed an aneurysmatical dilatation of the right vertebral artery which ruptured leading to subarachnoid hemorrhage. Although the ruptured right vertebral artery was clipped neurosurgically, she died two days later. Autopsy revealed GCA with focal medial necrosis and intimal thickening of the vertebral arteries and the basilar artery. No other arteries were affected. In the involved vessels, the media exhibited C1q immunoreactivity. At the intimal site of the internal elastic lamina there were increased levels of elastase. Other arterial diseases showing the pattern of GCA were excluded. This case demonstrates that GCA is not necessarily restricted to elderly people. Moreover, this case shows that a GCA-induced aneurysm is a very rare reason for subarachnoid hemorrhage even in young adults.


Assuntos
Aneurisma Roto/patologia , Arterite de Células Gigantes/patologia , Artéria Vertebral/patologia , Insuficiência Vertebrobasilar/patologia , Adulto , Artéria Basilar/patologia , Tronco Encefálico/patologia , Diagnóstico Diferencial , Evolução Fatal , Feminino , Humanos , Complicações Pós-Operatórias/patologia , Hemorragia Subaracnóidea/patologia
15.
Eur Heart J ; 22(2): 174-80, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11161919

RESUMO

AIMS: Implantation of single-lead VDD pacemakers is an established alternative to DDD pacing in patients with atrioventricular block. This study compares the long-term costs of both systems. METHODS AND RESULTS: Three hundred and sixty patients with atrioventricular block received VDD or DDD pacemakers in alternating order. Primary costs of implantation included: devices, leads and operation material, surgeons, nurses, medical technicians, and hospitalization. The mean cost of an uncomplicated DDD pacemaker implantation was defined as 1000 virtual cost-units (CU). Costs of pacemaker related complications or re-operations as well as upgrades from VDD to DDD devices were considered secondary costs and assessed during a mean follow-up period of 42+/-15 months. Pacing efficacy was assessed by event-free survival with maintained atrioventricular synchronized pacing mode. Costs of pacemaker devices were not different (639+/-26 CU in VDD vs 641+/-32 CU in DDD, ns). However, due to lower costs of lead hardware (102+/-10 CU in VDD vs 133+/-14 CU in DDD, P<0.001) and shorter implantation procedures (44.3+/-5.1 min vs 74.4+/-13.5 min, P<0.001), costs of an uncomplicated implantation were 8.9% lower in the VDD group (911+/-35 CU vs 1000+/-39 CU, P<0.001). A smaller complication rate in the VDD group led to a 16.1% reduction of secondary costs (26+/-17 CU year(-1)vs 31+/- 25 CU year(-1), P=0.024). Event-free survival did not differ between groups (83.4% in VDD vs 84.9% in DDD, ns). CONCLUSION: Use of single-lead VDD pacemakers achieves significant reduction of implantation and follow-up costs without loss of therapeutic efficacy compared to conventional DDD systems.


Assuntos
Estimulação Cardíaca Artificial/economia , Bloqueio Cardíaco/economia , Bloqueio Cardíaco/terapia , Marca-Passo Artificial/economia , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
16.
J Am Coll Cardiol ; 37(1): 44-50, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11153771

RESUMO

OBJECTIVES: The aim of this study was to determine the influence of early reperfusion on the course of QT interval and QT interval variability in patients undergoing primary percutaneous transluminal coronary angioplasty (PTCA) in acute myocardial infarction (AMI) and its prognostic implications on major arrhythmic events during one-year follow-up. BACKGROUND: Although early coronary artery recanalization by primary angioplasty is an established therapy in AMI, a substantial number of patients is still threatened by malignant arrhythmias even after early successful reperfusion, which may be caused by an inhomogeneity of ventricular repolarization despite reperfusion. METHOD: Temporal fluctuations of ventricular repolarization were studied prospectively in 97 consecutive patients with a first AMI by measurements of QT interval and QT interval variability during and after successful PTCA (Thrombolysis in Myocardial Infarction flow grades 2 and 3). Continuous beat-to-beat QT interval measurement was performed from 24-h Holter monitoring, which was initiated at admission before PTCA. RESULTS: Reperfusion caused a significant continuous increase of mean RR interval (738 +/- 98 to 808.5 +/- 121 ms; p < 0.001) and a significant decrease of parameters of QT interval (QTc: 440 +/- 32 to 416.5 +/- 37ms; p < 0.001) and QT interval variability (QTcSD: 27.5 +/- 3 to 24.9 +/- 6 ms; p < 0.001) in the majority of patients. However, in patients with major arrhythmic events at the one-year follow-up (sudden cardiac death, ventricular fibrillation or sustained ventricular tachycardia, n = 15), parameters of QT interval remained unaltered after successful reperfusion (QTc: 447.3 +/- 41 to 432.9 +/- 45 ms, p = NS; QTcSD: 35.1 +/- 13.4 to 29.0 +/- 9.1 ms, p = NS). CONCLUSIONS: Reduction of QT interval and QT interval variability after timely reperfusion of the infarct-related artery may be a previously unreported beneficial mechanism of primary PTCA in AMI, indicating successful reperfusion.


Assuntos
Angioplastia Coronária com Balão , Eletrocardiografia Ambulatorial , Síndrome do QT Longo/diagnóstico , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Síndrome do QT Longo/mortalidade , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Traumatismo por Reperfusão Miocárdica/terapia , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA