RESUMO
KEY MESSAGE: Here, we provide an updated set of guidelines for naming genes in wheat that has been endorsed by the wheat research community. The last decade has seen a proliferation in genomic resources for wheat, including reference- and pan-genome assemblies with gene annotations, which provide new opportunities to detect, characterise, and describe genes that influence traits of interest. The expansion of genetic information has supported growth of the wheat research community and catalysed strong interest in the genes that control agronomically important traits, such as yield, pathogen resistance, grain quality, and abiotic stress tolerance. To accommodate these developments, we present an updated set of guidelines for gene nomenclature in wheat. These guidelines can be used to describe loci identified based on morphological or phenotypic features or to name genes based on sequence information, such as similarity to genes characterised in other species or the biochemical properties of the encoded protein. The updated guidelines provide a flexible system that is not overly prescriptive but provides structure and a common framework for naming genes in wheat, which may be extended to related cereal species. We propose these guidelines be used henceforth by the wheat research community to facilitate integration of data from independent studies and allow broader and more efficient use of text and data mining approaches, which will ultimately help further accelerate wheat research and breeding.
Assuntos
Melhoramento Vegetal , Triticum , Triticum/genética , Fenótipo , Genes de Plantas , Grão Comestível/genéticaRESUMO
Ptychography is a scanning coherent diffractive imaging (CDI) technique that relies upon a high level of stability of the illumination during the course of an experiment. This is particularly an issue for coherent short wavelength sources, where the beam intensity is usually tightly focused on the sample in order to maximize the photon flux density on the illuminated region of the sample and thus a small change in the beam position results in a significant change in illumination of the sample. We present an improved ptychographic method that allows for limited stability of the illumination wavefront and thus significantly improve the reconstruction quality without additional prior knowledge. We have tested our reconstruction method in a proof of concept experiment, where the beam instability of a visible light source was emulated using a piezo driven mirror, and also in a short wavelength microscopy CDI setup using a high harmonic generation source in the extreme ultraviolet range. Our work shows a natural extension of the ptychography method that paves the way to use ptychographic imaging with any limited pointing stability coherent source such as free electron or soft X-ray lasers and improve reconstruction quality of long duration synchrotron experiments.
RESUMO
We have fabricated and measured single domain wall magnetoresistance devices with sub-20 nm gap widths using a novel combination of electron beam lithography and helium ion beam milling. The measurement wires and external profile of the spin valve are fabricated by electron beam lithography and lift-off. The critical bridge structure is created using helium ion beam milling, enabling the formation of a thinner gap (and so a narrower domain wall) than that which is possible with electron beam techniques alone. Four-point probe resistance measurements and scanning electron microscopy are used to characterize the milled structures and optimize the He ion dose. Successful operation of the device as a spin valve is demonstrated, with a 0.2% resistance change as the external magnetic field is cycled. The helium ion beam milling efficiency as extracted from electrical resistance measurements is 0.044 atoms/ion, about half the theoretical value. The gap in the device is limited to a maximum of 20 nm with this technique due to sub-surface swelling caused by injected ions which can induce catastrophic failure in the device. The fine patterning capabilities of the helium ion microscope milling technique indicate that sub-5 nm constriction widths could be possible.
RESUMO
Measurement of bone density in the spine and hip by quantitative computed tomography (QCT) and dual photon absorptiometry (DPA) was performed in 36 women with hip fracture. Hip density by DPA was determined at three anatomic subregions of the hip. Comparison to normals revealed an average decrease in hip bone density by 15% below controls. Spine density measurements were not significantly different from that of controls. Correlations of hip and spine densities varied by hip subregion. This study demonstrated that bone density measurement methods and measurement at one axial site may not accurately reflect bone density at appendicular subregions.