Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Pharm Sci ; : 106827, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38857708

RESUMO

BACKGROUND: Using accurate, sensitive, reproducible and efficient in vivo cutaneous pharmacokinetics (PK)-based bioequivalence (BE) approaches can promote the development of topical generic products. A clinical dermal open flow microperfusion (dOFM) study has previously demonstrated the BE of topical drug products containing a hydrophilic drug. However, the utility of dOFM to evaluate the topical BE of drug products containing moderately lipophilic drugs, more representative of most topical drugs, has not yet been established. OBJECTIVE: To evaluate the ability of a clinical dOFM study to assess BE of topical products containing two moderately lipophilic drugs that have only minor differences in chemical and physical properties. METHODS: The study included 20 healthy subjects. Four application sites on each thigh were treated with fixed dose lidocaine/prilocaine combination products, and dermal drug concentrations were monitored with two dOFM probes per application site for 12 hours. A reference cream was compared to itself and to an approved generic cream (both serving as positive controls for BE), and to a gel (negative control). BE was established based on AUC0to12h and Cmax using the scaled-average-BE approach. Systemic exposure of both drugs was assessed throughout the study. RESULTS: BE was successfully demonstrated for the positive controls, and not for the negative control, for both drugs. The systemic exposure of both drugs was negligible. CONCLUSIONS: dOFM accurately demonstrated BE between bioequivalent topical creams, sensitively discriminated between different formulations and differentiated the cutaneous PK of both study drugs, even though they differ only slightly in chemical and physical properties. These results support the utility of dOFM as a cutaneous PK BE approach for topical lipophilic drugs, including lidocaine and prilocaine.

3.
Pharm Res ; 41(2): 223-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38158503

RESUMO

PURPOSE: Accurate methods to determine dermal pharmacokinetics are important to increase the rate of clinical success in topical drug development. We investigated in an in vivo pig model whether the unbound drug concentration in the interstitial fluid as determined by dermal open flow microperfusion (dOFM) is a more reliable measure of dermal exposure compared to dermal biopsies for seven prescription or investigational drugs. In addition, we verified standard dOFM measurement using a recirculation approach and compared dosing frequencies (QD versus BID) and dose strengths (high versus low drug concentrations). METHODS: Domestic pigs were topically administered seven different drugs twice daily in two studies. On day 7, drug exposures in the dermis were assessed in two ways: (1) dOFM provided the total and unbound drug concentrations in dermal interstitial fluid, and (2) clean punch biopsies after heat separation provided the total concentrations in the upper and lower dermis. RESULTS: dOFM showed sufficient intra-study precision to distinguish interstitial fluid concentrations between different drugs, dose frequencies and dose strengths, and had good reproducibility between studies. Biopsy concentrations showed much higher and more variable values. Standard dOFM measurements were consistent with values obtained with the recirculation approach. CONCLUSIONS: dOFM pig model is a robust and reproducible method to directly determine topical drug concentration in dermal interstitial fluid. Dermal biopsies were a less reliable measure of dermal exposure due to possible contributions from drug bound to tissue and drug associated with skin appendages.


Assuntos
Pele , Suínos , Animais , Administração Cutânea , Reprodutibilidade dos Testes , Pele/metabolismo
4.
Mol Pharm ; 18(8): 3063-3072, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34247482

RESUMO

Traditionally, cutaneous drug delivery is studied by skin accumulation or skin permeation, while alternative techniques may enable the interactions between the drug and the skin to be studied in more detail. Time-resolved skin profiling for pharmacokinetic monitoring of two Janus Kinase (JAK) inhibitors, tofacitinib and LEO 37319A, was performed using dermal open-flow microperfusion (dOFM) for sampling of perfusate in an ex vivo and in vivo setup in pig skin. Additionally, matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) was performed to investigate depth-resolved skin distributions at defined time points ex vivo in human skin. By dOFM, higher skin concentrations were observed for tofacitinib compared to LEO 37319A, which was supported by the lower molecular weight, higher solubility, lipophilicity, and degree of protein binding. Using MALDI-MSI, the two compounds were observed to show different skin distributions, which was interpreted to be caused by the difference in the ability of the two molecules to interact with the skin compartments. In conclusion, the techniques assessed time- and depth-resolved skin concentrations and were able to show differences in the pharmacokinetic profiles of two JAK inhibitors. Thus, evidence shows that the two techniques can be used as complementary methods to support decision making in drug development.


Assuntos
Inibidores de Janus Quinases/administração & dosagem , Inibidores de Janus Quinases/farmacocinética , Perfusão/métodos , Piperidinas/administração & dosagem , Piperidinas/farmacocinética , Pirimidinas/administração & dosagem , Pirimidinas/farmacocinética , Absorção Cutânea/efeitos dos fármacos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Administração Cutânea , Animais , Composição de Medicamentos/métodos , Feminino , Humanos , Inibidores de Janus Quinases/química , Pessoa de Meia-Idade , Peso Molecular , Piperidinas/química , Pirimidinas/química , Pele/efeitos dos fármacos , Pele/metabolismo , Solubilidade , Suínos , Distribuição Tecidual
5.
Pharm Res ; 37(10): 204, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-32989514

RESUMO

PURPOSE: Dermal open flow microperfusion (dOFM) has previously demonstrated its utility to assess the bioequivalence (BE) of topical drug products in a clinical study. We aimed to characterize the sources of variability in the dermal pharmacokinetic data from that study. METHODS: Exploratory statistical analyses were performed with multivariate data from a clinical dOFM-study in 20 healthy adults evaluating the BE, or lack thereof, of Austrian test (T) and U.S. reference (R) acyclovir cream, 5% products. RESULTS: The overall variability of logAUC values (CV: 39% for R and 45% for T) was dominated by inter-subject variability (R: 82%, T: 91%) which correlated best with the subject's skin conductance. Intra-subject variability was 18% (R) and 9% (T) of the overall variability; skin treatment sites or methodological factors did not significantly contribute to that variability. CONCLUSIONS: Inter-subject variability was the major component of overall variability for acyclovir, and treatment site location did not significantly influence intra-subject variability. These results support a dOFM BE study design with T and R products assessed simultaneously on the same subject, where T and R treatment sites do not necessarily need to be next to each other. Localized variation in skin microstructure may be primarily responsible for intra-subject variability.


Assuntos
Aciclovir/farmacocinética , Perfusão/métodos , Pele/efeitos dos fármacos , Pele/metabolismo , Aciclovir/administração & dosagem , Administração Cutânea , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Absorção Cutânea , Equivalência Terapêutica
6.
J Lipid Res ; 60(4): 758-766, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30696699

RESUMO

Eicosanoids are lipid-mediator molecules with key roles in inflammatory skin diseases, such as psoriasis. Eicosanoids are released close to the source of inflammation, where they elicit local pleiotropic effects and dysregulations. Monitoring inflammatory mediators directly in skin lesions could provide new insights and therapeutic possibilities. Here, we analyzed dermal interstitial fluid samples obtained by dermal open-flow microperfusion in a rat model of skin inflammation. We developed a solid-phase extraction ultra-HPLC/MS/MS method to reliably and precisely analyze small-volume samples and quantified 11 eicosanoids [thromboxane B2, prostaglandin (PG) E2, PGD2, PGF2α, leukotriene B4, 15-HETE, 12-HETE, 5-HETE, 12-hydroxyeicosapentaenoic acid, 13-HODE, and 17-hydroxydocosahexaenoic acid]. Our method achieved a median intraday precision of approximately 5% and interday precision of approximately 8%. All calibration curves showed excellent linearity between 0.01 and 50 ng/ml (R2 > 0.980). In the rat model, eicosanoids were significantly increased in imiquimod-treated inflamed skin sites compared with untreated control sites. Oral treatment with an anti-inflammatory glucocorticoid decreased eicosanoid concentrations. These results show that a combination of tissue-specific sampling with LC/MS analytics is well suited for analyzing small sample volumes from minimally invasive sampling methods such as open-flow microperfusion or microdialysis to study local inflammation and the effect of treatments in skin diseases.


Assuntos
Modelos Animais de Doenças , Eicosanoides/análise , Inflamação/metabolismo , Dermatopatias/metabolismo , Pele/química , Extração em Fase Sólida , Animais , Anti-Inflamatórios/farmacologia , Cromatografia Líquida de Alta Pressão , Eicosanoides/antagonistas & inibidores , Eicosanoides/metabolismo , Glucocorticoides/farmacologia , Inflamação/tratamento farmacológico , Masculino , Ratos , Ratos Sprague-Dawley , Pele/metabolismo , Dermatopatias/tratamento farmacológico , Espectrometria de Massas em Tandem
7.
Biomed Chromatogr ; 32(6): e4194, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29349796

RESUMO

Time-concentration curves for the topical anti-viral drug acyclovir can provide valuable information for drug development. Open flow microperfusion is used for continuous sampling of dermal interstitial fluid but it requires validated methods for subsequent sample analysis. Therefore, we developed a sensitive, selective and high-throughput ultra-high-performance liquid chromatography-high-resolution tandem mass spectrometry method to determine acyclovir in human dermal interstitial fluid and serum. We validated the method over a concentration range of 0.1-25 ng/mL for a sample volume of just 20 µL and employed cation-exchange solid-phase extraction in a fully automated sample treatment procedure. Short- and long-term sample stability data and the analysis of 5000 samples from a clinical trial demonstrate the successful application of our method.


Assuntos
Aciclovir/análise , Aciclovir/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Derme/citologia , Líquido Extracelular/química , Espectrometria de Massas em Tandem/métodos , Aciclovir/sangue , Derme/química , Derme/metabolismo , Líquido Extracelular/metabolismo , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Extração em Fase Sólida , Equivalência Terapêutica
8.
Clin Pharmacokinet ; 56(1): 91-98, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27539717

RESUMO

BACKGROUND: The availability of generic topical dermatological drug products is constrained by the limited methods established to assess topical bioequivalence (BE). A novel cutaneous pharmacokinetic approach, dermal open-flow microperfusion (dOFM), can continuously assess the rate and extent to which a topical drug becomes available in the dermis, to compare in vivo dermal bioavailability (BA) and support BE evaluations for topical products. OBJECTIVE: To evaluate whether dOFM is an accurate, sensitive, and reproducible in vivo method to characterize the intradermal BA of acyclovir from 5 % acyclovir creams, comparing a reference (R) product either to itself or to a different test (T) product. METHODS: In a single-center clinical study, R or T products were applied to six randomized treatment sites on the skin of 20 healthy human subjects. Two dOFM probes were inserted in each treatment site to monitor the intradermal acyclovir concentration for 36 h. Comparative BA (of R vs. R and T vs. R) was evaluated based on conventional BE criteria for pharmacokinetic endpoints (area under the curve and maximum dermal concentration) where the 90 % confidence interval of the geometric mean ratio between the T and R falls within 0.80-1.25. RESULTS: The positive control products (R vs. R) were accurately and reproducibly confirmed to be bioequivalent, while the negative control products (T vs. R) were sensitively discriminated not to be bioequivalent. CONCLUSIONS: dOFM accurately, sensitively, and reproducibly characterized the dermal BA in a manner that can support BE evaluations for topical acyclovir 5 % creams in a study with n = 40 (20 subjects in this study).


Assuntos
Aciclovir/farmacocinética , Antivirais/farmacocinética , Microdiálise/métodos , Creme para a Pele/farmacocinética , Aciclovir/administração & dosagem , Administração Cutânea , Adulto , Antivirais/administração & dosagem , Área Sob a Curva , Feminino , Humanos , Masculino , Creme para a Pele/administração & dosagem , Equivalência Terapêutica
10.
J Allergy Clin Immunol ; 139(3): 923-932.e8, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27502297

RESUMO

BACKGROUND: IL-17A is a key driver of human autoimmune diseases, particularly psoriasis. OBJECTIVE: We sought to determine the role of IL-17A in psoriasis pathogenesis and to identify a robust and measurable biomarker of IL-17A-driven pathology. METHODS: We studied 8 healthy subjects and 8 patients with psoriasis before and after administration of secukinumab, a fully human anti-IL-17A mAb, and used a combination of classical techniques and a novel skin microperfusion assay to evaluate the expression of 170 proteins in blood, nonlesional skin, and lesional skin. For validation, we also tested stored sera from 601 patients with a variety of autoimmune diseases. RESULTS: IL-17A was specifically expressed in lesional compared with nonlesional psoriatic skin (9.8 vs 0.8 pg/mL, P < .001). Proteomic and gene transcription analyses revealed dysregulated antimicrobial peptides, proinflammatory cytokines, and neutrophil chemoattractants, levels of which returned to normal after treatment with secukinumab. ß-Defensin 2 (BD-2) was identified as a biomarker of IL-17A-driven pathology by comparing protein expression in patients with psoriasis versus that in healthy subjects (5746 vs 82 pg/mL in serum, P < .0001; 2747 vs <218 pg/mL in dermis, P < .001), responsiveness to secukinumab therapy, and synergistic induction by IL-17A and TNF-α in epidermal keratinocytes. In a validation set of sera from 601 patients with autoimmune diseases thought to be IL-17A driven, we found that BD-2 levels are most highly increased in patients with psoriatic skin lesions, and in patients with psoriasis, BD-2 levels correlated well with IL-17A levels (r = 0.70, n = 199, P < .001) and Psoriasis Area and Severity Index scores (r = 0.53, n = 281, P < .001). CONCLUSION: IL-17A is a primary driver of skin pathology in patients with psoriasis, and serum BD-2 is an easily measurable biomarker of IL-17A-driven skin pathology.


Assuntos
Interleucina-17/sangue , Psoríase/sangue , beta-Defensinas/sangue , Adulto , Anticorpos Monoclonais/farmacologia , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados , Doenças Autoimunes/sangue , Biomarcadores/sangue , Feminino , Humanos , Masculino , Psoríase/tratamento farmacológico , Psoríase/imunologia , Pele/imunologia , Pele/patologia
11.
Pharm Res ; 33(9): 2229-38, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27271272

RESUMO

PURPOSE: To evaluate the kinetics of topically applied clobetasol-17-propionate (CP-17) in lesional and non-lesional psoriatic skin when released from a commercially available low-strength cream using in vivo dermal open-flow microperfusion (dOFM). METHODS: Twelve patients received Dermovate® cream (CP-17, 0.05%) on small lesional and non-lesional skin test sites for 14 days, once daily. On day 1 and 14, dOFM samples were continuously taken in the dermis for 24 h post-dose and analyzed by LC-MS/MS. Probe depths were assessed by 50 MHz ultrasound scanning. RESULTS: Mixed-effects modelling identified skin condition, treatment duration and probe-depth as kinetics determining variables. The time- and depth-resolved intradermal data revealed (i) slower penetration of CP-17 into lesional than into non-lesional skin, (ii) normalized (faster) skin penetration after repeated dosing, and (iii) no CP-17 accumulation within the dermis independently of the skin condition. CONCLUSIONS: Intradermal investigation of a highly lipophilic drug released from low-strength cream was successfully performed by using dOFM and timely and spatially, i.e., probe-depth dependent, resolved kinetic data were delivered. These data support the assumption that the thickened psoriatic stratum corneum might act as trap compartment which lowers the skin penetration rate for lipophilic topical drugs.


Assuntos
Clobetasol/administração & dosagem , Clobetasol/farmacocinética , Pele/efeitos dos fármacos , Pele/metabolismo , Administração Cutânea , Adulto , Cromatografia Líquida/métodos , Feminino , Humanos , Cinética , Masculino , Perfusão/métodos , Absorção Cutânea/fisiologia , Espectrometria de Massas em Tandem/métodos
14.
Diabetes Technol Ther ; 15(1): 50-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23126579

RESUMO

BACKGROUND: Treatment of type 1 diabetes patients could be simplified if the site of subcutaneous insulin infusion could also be used for the measurement of glucose. This study aimed to assess the agreement between blood glucose concentrations and glucose levels in the interstitial fluid (ISF) that is extracted from the insulin infusion site during periodic short-term interruptions of continuous subcutaneous insulin infusion (CSII). SUBJECTS AND METHODS: A perforated cannula (24 gauge) was inserted into subcutaneous adipose tissue of C-peptide-negative type 1 diabetes subjects (n=13) and used alternately to infuse rapid-acting insulin (100 U/mL) and to extract ISF glucose during a fasting period and after ingestion of a standard oral glucose load (75 g). RESULTS: Although periodically interrupted for extracting glucose (every hour for approximately 10 min), insulin infusion with the cannula was adequate to achieve euglycemia during fasting and to restore euglycemia after glucose ingestion. Furthermore, the ISF-derived estimates of plasma glucose levels agreed well with plasma glucose concentrations. Correlation coefficient and median absolute relative difference values were found to be 0.95 and 8.0%, respectively. Error grid analysis showed 99.0% of all ISF glucose values within clinically acceptable Zones A and B (83.5% Zone A, 15.5% Zone B). CONCLUSIONS: Results show that ISF glucose concentrations measured at the insulin infusion site during periodic short-term interruptions of CSII closely reflect blood glucose levels, thus suggesting that glucose monitoring and insulin delivery may be performed alternately at the same tissue site. A single-port device of this type could be used to simplify and improve glucose management in diabetes.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Líquido Extracelular/metabolismo , Glucose/metabolismo , Hipoglicemiantes/uso terapêutico , Insulina de Ação Curta/uso terapêutico , Adolescente , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Líquido Extracelular/química , Feminino , Humanos , Infusões Subcutâneas , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
15.
Eur J Pharm Biopharm ; 81(3): 635-41, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22554768

RESUMO

BACKGROUND: Methodologies for continuous sampling of lipophilic drugs and high-molecular solutes in the dermis are currently lacking. We investigated the feasibility of sampling a lipophilic topical drug and the locally released biomarker in the dermis of non-lesional and lesional skin of psoriatic patients over 25h by means of membrane-free dermal open-flow microperfusion probes (dOFM) and novel wearable multi-channel pumps. METHODS: Nine psoriatic patients received a topical p-38 inhibitor (BCT194, 0.5% cream) on a lesional and a non-lesional application site once daily for 8 days. Multiple dOFM sampling was performed for 25 h from each site on day 1 and day 8. Patients were mobile as dOFM probes were operated by a novel light-weight push-pull pump. Ultrasound was used to verify intradermal probe placement, cap-LC-MS/MS for BCT194 and ELISA for TNFα analysis. RESULTS: dOFM was well tolerated and demonstrated significant drug concentrations in lesional as well as non-lesional skin after 8 days, but did not show significant differences between tissues. On day 8, TNFα release following probe insertion was significantly reduced compared to day 1. CONCLUSIONS: Novel membrane-free probes and wearable multi-channel pumps allowed prolonged intradermal PK/PD profiling of a lipophilic topical drug in psoriatic patients. This initial study shows that dOFM overcomes limitations of microdialysis sampling methodology, and it demonstrates the potential for PK/PD studies of topical products and formulations in a clinical setting.


Assuntos
Microdiálise/métodos , Psoríase/tratamento farmacológico , Fator de Necrose Tumoral alfa/metabolismo , Administração Cutânea , Adulto , Biomarcadores/metabolismo , Cromatografia Líquida/métodos , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão/métodos , Espectrometria de Massas em Tandem , Fatores de Tempo , Adulto Jovem , Proteínas Quinases p38 Ativadas por Mitógeno/antagonistas & inibidores
16.
Cytokine ; 50(3): 284-91, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20303782

RESUMO

Cytokines are inflammatory mediators of major relevance during sepsis. Recent evidence shows that adipose tissue can produce many distinct cytokines under physiological and pathological conditions, but the role of cytokines produced in adipose tissue was not addressed in sepsis. In the present study the open-flow microperfusion (OFM) technique was used to investigate whether the cytokines produced in subcutaneous adipose tissue (SAT) of patients with severe sepsis correlate with clinical variables. Interstitial fluid effluent samples were collected using an OFM catheter inserted in the abdominal SAT of nine patients with severe sepsis. Blood samples were withdrawn concomitantly and interleukin-1beta (IL-1beta), IL-8, IL-6 and tumor necrosis factor alpha (TNF-alpha) were measured both in SAT effluent and serum samples. Different time profiles were registered for each cytokine. IL-1beta increased in a time-dependent manner, indicating a localized response against the catheter insertion. Interleukin-1beta, 6 and 8 were higher in SAT than in serum suggesting they were locally produced. Diastolic blood pressure (DBP) negatively correlated with IL-1beta, IL-6 and IL-8 in SAT indicating a possible interaction between adipose tissue inflammation and vascular tone regulation. A multiple regression analysis disclosed that mean DBP was significantly related to IL-6 concentrations in SAT (B=-43.9; R-square=0.82; P=0.002).


Assuntos
Pressão Sanguínea/fisiologia , Interleucina-6/biossíntese , Sepse/fisiopatologia , Gordura Subcutânea/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antropometria , Diástole/fisiologia , Feminino , Humanos , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Sepse/sangue , Gordura Subcutânea/fisiopatologia , Fatores de Tempo , Adulto Jovem
17.
Int J Endocrinol ; 2009: 390975, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19946427

RESUMO

Minimally invasive techniques to access subcutaneous adipose tissue for glucose monitoring are successfully applied in type1 diabetic and critically ill patients. During critical illness, the addition of a lactate sensor might enhance prognosis and early intervention. Our objective was to evaluate SAT as a site for lactate measurement in critically ill patients. In 40 patients after major cardiac surgery, arterial blood and SAT microdialysis samples were taken in hourly intervals. Lactate concentrations from SAT were prospectively calibrated to arterial blood. Analysis was based on comparison of absolute lactate concentrations (arterial blood vs. SAT) and on a 6-hour lactate trend analysis, to test whether changes of arterial lactate can be described by SAT lactate. Correlation between lactate readings from arterial blood vs. SAT was highly significant (r2 = 0.71, P < .001). Nevertheless, 42% of SAT lactate readings and 35% of the SAT lactate trends were not comparable to arterial blood. When a 6-hour stabilization period after catheter insertion was introduced, 5.5% of SAT readings and 41.6% of the SAT lactate trends remained incomparable to arterial blood. In conclusion, replacement of arterial blood lactate measurements by readings from SAT is associated with a substantial shortcoming in clinical predictability in patients after major cardiac surgery.

18.
J Diabetes Sci Technol ; 3(1): 110-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20046655

RESUMO

BACKGROUND: Intensive insulin therapy reduces mortality and morbidity in critically ill patients but places great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A cost-effective solution to this resourcing problem could be provided by an effective and reliable automated blood sampling (ABS) system suitable for ex vivo glucose determination. METHOD: The primary study aim was to compare the performance of a prototype ABS system with a manual reference system over a 30 h sampling period under controlled conditions in humans. Two venous cannulae were inserted to connect the ABS system and the reference system. Blood samples were taken with both systems at 15, 30, and 60 min intervals and analyzed using a Beckman glucose analyzer. During the study, blood glucose levels were altered through four meal ingestions. RESULTS: The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.976 (0.953-0.996). The system error was -3.327 ± 5.546% (-6.03-0.49). Through Clark error grid analysis, 420 data pairs were analyzed, showing that 98.6% of the data were in zone A and 1.4% were in zone B. Insulin titration error grid analysis revealed an acceptable treatment in 100% of cases. A 17.5-fold reduction in the occurrence of blood-withdrawal failures through occluded catheters was moreover achieved by the added implementation in the ABS system of a "keep vein open" saline infusion. CONCLUSIONS: Our study showed that the ABS system described provides a user-friendly, reliable automated means for reproducible and accurate blood sampling from a peripheral vein for blood glucose determination and thus represents a promising alternative to frequent manual blood sampling.


Assuntos
Glicemia/análise , Monitorização Fisiológica/métodos , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes
19.
Am J Physiol Endocrinol Metab ; 293(3): E690-6, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17578890

RESUMO

Inflammatory cytokines released from adipose tissue play an important role in different pathological processes. In the present study, we investigated the inflammatory cytokine response of human subcutaneous adipose tissue (SAT) by applying the open-flow microperfusion technique. Four standard 18-gauge microperfusion catheters were inserted into periumbilical SAT of eight healthy male volunteers [29 +/- 3 yr, BMI 24.3 +/- 1.9 (mean +/- SD)]. SAT probe effluents were collected at 60-min intervals for 8 h after catheter insertion. Different perfusion fluids were used to measure the local effect of insulin and/or glucose on the cytokine response. SAT probe effluents were analyzed for IL-1beta, IL-6, CXCL8 (IL-8), and TNF-alpha. SAT concentrations of IL-1beta increased 100-fold from 1.0 +/- 0.2 pg/ml (mean +/- SE) to 101.5 +/- 23.2 pg/ml (P < 0.001) after 8 h. A 130-fold increase was observed for CXCL8, from 49 +/- 29 to 6,554 +/- 1,713 pg/ml (P < 0.001). Furthermore, a 20-fold increase of IL-6 was observed within the first 5 h (from 159 +/- 123 to 3,554 +/- 394 pg/ml; P < 0.001), and a significant decline to 2,154 +/- 216 pg/ml (P < 0.01) was seen thereafter. Finally, TNF-alpha increased from 1.4 +/- 0.6 to 2.5 +/- 0.5 pg/ml (P < 0.05) in hour 2 and remained stable thereafter. Local administration of insulin exerted a stimulatory effect on the inflammatory response of IL-6. In conclusion, SAT exerts a highly reproducible and consistent proinflammatory cytokine response after minimally invasive trauma caused by the insertion of a catheter in humans.


Assuntos
Tecido Adiposo/imunologia , Citocinas/imunologia , Inflamação/imunologia , Pele/imunologia , Pele/lesões , Ferimentos e Lesões/imunologia , Adulto , Humanos , Fatores Imunológicos/imunologia , Inflamação/induzido quimicamente , Insulina , Masculino
20.
J Biomed Opt ; 12(2): 024004, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17477719

RESUMO

An IR-spectroscopy-based bedside device, coupled to a subcutaneously implanted microdialysis probe, is developed for quasicontinuous glucose monitoring with intermittent readouts at 10-min intervals, avoiding any sensor recalibration under long-term operation. The simultaneous estimation of the microdialysis recovery rate is possible using an acetate containing perfusate and determining its losses across the dialysis membrane. Measurements are carried out on four subjects, with experiments lasting either 8 or 28 h, respectively. Using the spectral interval data either from 1180 to 950 or 1560 to 1000 cm(-1), standard errors of prediction (SEPs) between 0.13 and 0.28 mM are achieved using multivariate calibration with partial least-squares (PLS) or classical least-squares (CLS) calibration models, respectively. The transfer of a PLS calibration model using the spectral and reference concentration data of the dialysates from the three 8-h-long experiments to a 28-h monitoring episode with another healthy subject is tested. Including microdialysis recovery for the determination of the interstitial glucose concentrations, an SEP of 0.24 mM is obtained versus whole blood glucose values. The option to determine other metabolites such as urea or lactate offers the possibility to develop a calibration- and reagent-free point-of-care analyzer.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/análise , Microdiálise/métodos , Monitorização Ambulatorial/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Espectrofotometria Infravermelho/métodos , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA