Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Plast Reconstr Surg Glob Open ; 12(1): e5535, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38250205

RESUMO

Background: Polyethylene glycol (PEG) is a synthetic, biodegradable, and hyperosmotic material promising in the treatment of acute peripheral nerve injuries. Our team set out to investigate the impact of fibrin glue upon PEG fusion in a rat model. Methods: Eighteen rats underwent sciatic nerve transection and PEG fusion. Electrophysiologic testing was performed to measure nerve function and distal muscle twitch. Fibrin glue was applied and testing repeated. Due to preliminary findings, fibrin glue was applied to an uncut nerve in five rodents and testing was conducted before and after glue application. Mann-Whitney U tests were used to compare median values between outcome measures. A Shapiro-Wilk test was used to determine normality of data for each comparison, significance set at a P value less than 0.05. Results: PEG fusion was confirmed in 13 nerves with no significant change in amplitude (P = 0.054), latency (P = 0.114), or conduction velocity (P = 0.114). Stimulation of nerves following PEG fusion produced distal muscle contraction in 100% of nerves. Following application of fibrin glue, there was a significant reduction in latency (P = 0.023), amplitude (P < 0.001), and conduction velocity (P = 0.023). Stimulation of the nerve after application of fibrin glue did not produce distal muscle twitch. Five uncut nerves with fibrin glue application blocked distal muscle contraction following stimulation. Conclusions: Our data suggest that fibrin glue alters the nerve's function. The immediate confirmation of PEG fusion via distal muscle twitch is blocked with application fibrin glue in this experimental model. Survival and functional outcome studies are necessary to understand if this has implications on the long-term functional outcomes.

3.
Muscle Nerve ; 55(3): 301-304, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27859377

RESUMO

Distal symmetric polyneuropathy (DSP) is one of the most common problems seen in clinical practice and one of the most frequent reasons for electrodiagnostic (EDx) testing. Most studies have supported the use of EDx testing for patients with suspected DSP. Some recent articles assert that EDx testing has a low yield in suspected DSP and is only needed for atypical presentations (a minority). However, many peer-reviewed articles indicate that EDx frequently changes diagnosis and management, and leads to a better understanding of the underlying pathology, severity, and prognosis. Overall, EDx is appropriate for most patients with new signs and symptoms of DSP. Muscle Nerve 55: 301-304, 2017.


Assuntos
Eletrodiagnóstico , Polineuropatias/diagnóstico , Humanos , Polineuropatias/fisiopatologia
4.
J Electromyogr Kinesiol ; 31: 1-6, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27614047

RESUMO

PURPOSE: To prove that the relationship between sensory latencies and amplitudes is useful in determining the severity of neuropathies. This is achieved by deriving a mathematical relationship between sensory distal latency and amplitude. Determine whether sensory amplitudes below predicted correlate with a worse pathology. PROCEDURES: Patients seen for Nerve Conduction Studies by the Department of Physical Medicine and Rehabilitation at Cooper University Hospital between 12/1/12 and 12/31/14 were invited to participate in a prospective database. The median, ulnar and sural sensory latencies and amplitudes were analyzed with both linear and power regression. Patients with amplitudes above and below the regression curve were compared for latency, amplitude and velocity of other nerves. Carpal Tunnel Patients were analyzed to determine whether Median sensory amplitude below predicted correlated with more severe disease. RESULTS: For the Median nerve, Power Regression Analysis showed a stronger correlation (R2=0.54) than linear regression (R2=0.34). Patients with Median sensory amplitude below the power correlation curve showed significantly longer ulnar sensory latency, and lower sensory amplitude than those above. Carpal Tunnel Syndrome patients with Median sensory amplitude well below predicted by the power relationship showed more advanced disease. For the ulnar and sural sensory nerve, the difference between power and linear regression was not significant. CONCLUSIONS: A power regression curve correlates sensory latency and amplitude better than linear regression. The latency amplitude relationship correlates with other parameters of nerve function and severity of Carpal Tunnel Syndrome. This implies that below predicted sensory amplitude may indicate worse disease, and could be a useful diagnostic tool.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Condução Nervosa , Tempo de Reação , Células Receptoras Sensoriais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndrome do Túnel Carpal/diagnóstico , Feminino , Humanos , Masculino , Nervo Mediano/fisiopatologia , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Nervo Ulnar/fisiopatologia
5.
J Clin Neurophysiol ; 32(3): 244-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25420157

RESUMO

PURPOSE: To determine whether Contraction Induced H Reflexes (CIHR) can accurately detect cervical radiculopathy. METHODS: Comparison of CIHR results with Needle Electromyography at academic outpatient Electromyography/Nerve Conduction laboratories. Participants were all patients over 18 with a needle electromyography diagnosis of cervical radiculopathy. Patients were tested for CIHR in at least two upper extremity muscles in electromyographically proven myotomes bilaterally. Patients were requested to perform a moderate contraction while stimulus was applied proximally (elbow or Erb's point). Outcome measures included H Reflex onset latency and side-to-side latency differences. These were compared against previously established normal values. RESULTS: Overall, 10 of 15 patients who met criteria for cervical radiculopathy showed CIHR abnormalities (sensitivity = 67%; 95% confidence interval, 43-91). Counting each side and level separately, CIHR identified 16/27 radiculopathies (sensitivity = 59.2%; 95% confidence interval, 40.6-77.8). Contraction Induced H Reflexes identified 1 possible radiculopathy not seen on electromyography (specificity = 98%; 95% confidence interval, 95-100). CONCLUSIONS: Contraction induced H Reflexes have a sensitivity and specificity for cervical radiculopathy similar to the resting Gastroc-Soleus H Reflex.


Assuntos
Eletromiografia/métodos , Radiculopatia/diagnóstico , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Contração Muscular , Radiculopatia/fisiopatologia , Reflexo , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA