Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 11(1): e041883, 2021 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-33455933

RESUMO

OBJECTIVE: High radiation exposure is a concern because of the association with cancer. The objective was to determine the probability of receiving a high radiation dose from CT (from one or more examinations within a 5-year period) and to assess the clinical context by evaluating clinical indications in the high-dose patient group. DESIGN: Observational cohort study. Effective radiation dose received from one or more CT examinations within a predefined 5-year calendar period was assessed for each patient. SETTING: Hospital setting. PARTICIPANTS: All patients undergoing a diagnostic CT examination between July 2013 and July 2018 at the Maastricht University Medical Center. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome was the probability of receiving a high effective dose, defined as ≥100 mSv, from one or more CT examinations within 5 years as derived from a time-to-event analysis. Secondary outcomes were the clinical indication for the initial scan of patients receiving a high effective dose. RESULTS: 100 672 CT examinations were performed among 49 978 patients including 482 (1%) who received a high radiation dose. The estimated probability of a high effective dose from a single examination is low (0.002% (95% CI 0.00% to 0.01%)). The 4.5-year probability of receiving a high cumulative effective dose was 1.9% (95% CI 1.6% to 2.2%) for women and 1.5% (95% CI 1.3% to 1.7%) for men. The probability was highest in age categories between 51 and 74 years. A total of 2711 (5.5%) of patients underwent more than six CT examinations, and the probability of receiving a high effective dose was 16%. Among patients who received a high effective dose, most indications (80%) were oncology related. CONCLUSIONS: The probability of receiving a high radiation dose from CT examinations is small but not negligible. In the majority (80%) of high effective dose receiving patients, the indication for the initial CT scan was oncology related.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Doses de Radiação , Exposição à Radiação/efeitos adversos
2.
AJR Am J Roentgenol ; 210(5): W226-W233, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29570369

RESUMO

OBJECTIVE: Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality. MATERIALS AND METHODS: One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDIvol) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDIvol versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDIvol values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale. RESULTS: The CTDIvol depended on patient size and scanner type (R2 = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDIvol (R2 = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better. CONCLUSION: We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Tamanho Corporal , Angiografia por Tomografia Computadorizada/normas , Doses de Radiação , Artefatos , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste , Humanos , Iohexol/análogos & derivados , Valores de Referência , Razão Sinal-Ruído , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA