Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Small Anim Pract ; 59(3): 174-182, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28960319

RESUMO

OBJECTIVES: The aims of this study were to describe a method for the sonographic assessment of volaemia, to determinate inter- and intra-operator variability and to assess the ability to detect blood loss after blood donation in healthy dogs. MATERIALS AND METHODS: The left kidney was identified in a spleno-renal view, and transverse views of the caudal vena cava and aorta were obtained in 12 dogs. Vessel diameters were measured in B-mode, in duplicate by two operators, and the caudal vena cava:aorta ratio was calculated. Intra- and inter-operator variabilities were assessed using a Bland-Altman method by plotting the differences between the repeated measurements obtained from the same subject by the same operator and by the two operators against their means. Before and after blood donation measurements were compared using paired t-tests or one-sample t-tests, if appropriate. RESULTS: Intra- and inter-operator variability was within the limit of agreement for the vast majority of measurements. After a blood donation of 9·8 ±2·2 mL/kg, the mean aorta measurements were not significantly different from those obtained before blood donation (1·11 versus 1·10, P=0·28), whereas the mean caudal vena cava measurements and caudal vena cava:aorta ratios were significantly lower (1·28 versus 1·01, P<0·0001; 1·17 versus 1·01, P=0·0001, respectively). CLINICAL SIGNIFICANCE: The low intra- and inter-operator variabilities in the caudal vena cava, aorta and caudal vena cava:aorta ratio measurements support their reliability and operator independency. The sonographic assessment of volaemia appears to be a promising non-invasive, repeatable point-of-care ultrasound protocol for assessment and monitoring of blood loss. Further studies are needed to assess the sonographic assessment of volaemia protocol in spontaneously bleeding dogs.


Assuntos
Aorta/diagnóstico por imagem , Doadores de Sangue , Volume Sanguíneo/veterinária , Cães/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Animais , Cães/anatomia & histologia , Feminino , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia/veterinária
2.
J Vet Intern Med ; 31(5): 1420-1429, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28804957

RESUMO

BACKGROUND: When dogs are transfused, blood compatibility testing varies widely but may include dog erythrocyte antigen (DEA) 1 typing and rarely cross-matching. OBJECTIVES: Prospective study to examine naturally occurring alloantibodies against red blood cells (RBCs) and alloimmunization by transfusion using 2 antiglobulin-enhanced cross-match tests. ANIMALS: Eighty client-owned anemic, 72 donor, and 7 control dogs. METHODS: All dogs were typed for DEA 1 and some also for DEA 4 and DEA 7. Major cross-match tests with canine antiglobulin-enhanced immunochromatographic strip and gel columns were performed 26-129 days post-transfusion (median, 39 days); some dogs had an additional early evaluation 11-22 days post-transfusion (median, 16 days). Plasma from alloimmunized recipients was cross-matched against RBCs from 34 donor and control dogs. RESULTS: The 2 cross-match methods gave entirely concordant results. All 126 pretransfusion cross-match results for the 80 anemic recipients were compatible, but 54 dogs died or were lost to follow up. Among the 26 recipients with follow-up, 1 dog accidently received DEA 1-mismatched blood and became cross-match-incompatible post-transfusion. Eleven of the 25 DEA 1-matched recipients (44%) became incompatible against other RBC antigens. No naturally occurring anti-DEA 7 alloantibodies were detected in DEA 7- dogs. CONCLUSIONS AND CLINICAL IMPORTANCE: The antiglobulin-enhanced immunochromatographic strip cross-match and laboratory gel column techniques identified no naturally occurring alloantibodies against RBC antigens, but a high degree of post-transfusion alloimmunization in dogs. Cross-matching is warranted in any dog that has been previously transfused independent of initial DEA 1 typing and cross-matching results before the first transfusion event.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/veterinária , Transfusão de Sangue/veterinária , Teste de Coombs/veterinária , Cães/imunologia , Animais , Anticorpos Anti-Idiotípicos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Isoanticorpos/imunologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA