1.
J Biomed Mater Res B Appl Biomater ; 110(10): 2290-2298, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35657060

RESUMO

Flanged acetabular cups were developed with the rationale that, at insertion, they would increase the pressure of the cement and improve penetration of cement into the acetabular bone. Various studies have been inconclusive regarding their effectiveness. In this work, we aimed to eliminate all confounding factors and measure the pressures generated during acetabular pressurization and cup implantation using a simplified steel acetabulum, high precision pressure transducers, proper surgical techniques and two acetabular cups, identical apart from the addition of a flange to one. It was found that the flanged acetabular component did not significantly increase the pressure in the acetabulum and in some cases reduced the pressures generated when compared to an unflanged cup. The addition of a flange did not reduce the pressure differential between the pole and the rim of the acetabulum, nor did it have a significant effect on pressure lost over the cup implantation period. It was concluded that flanged acetabular cups provide no significant improvement in the pressures generated in the acetabulum during acetabular cup implantation. It is hypothesized that the flange may be seen as a design feature intended to slow the insertion of the cup into the cement, thus requiring the surgeon to apply a larger load in order to correctly position the acetabular cup; in this way larger pressure will be generated.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cimentos Ósseos , Pressão , Desenho de Prótese
2.
Proc Inst Mech Eng H ; 235(2): 133-140, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33054541

RESUMO

Radiolucent lines on immediate postoperative cemented acetabular component radiographs between the PMMA bone cement mantle and bone are an indicator of an increased risk of early loosening. The cause of these lines has yet to be identified. Thermal and chemical necrosis, fluid interposition and cement shrinkage have all been suggested in the literature. The aim of the study reported here was to take an engineering approach - eliminating confounding variables present during surgery - to quantify the size of the interstice created by cement shrinkage when a 50 mm diameter flanged acetabular cup is implanted in a model acetabulum with a 52 mm hemispherical bore under controlled conditions using vacuum and non-vacuum mixed cement. Irrespective of the mixing method used, a significant interstice was created between the bone cement and the mock acetabulum. When the cement was mixed under vacuum the interstice created between the mock acetabulum and the cement mantle was 0.60 mm ± 0.09 mm; when the cement was mixed under non-vacuum conditions the interstice created was 0.39 mm ± 0.15 mm. Possible explanations for radiolucent lines are discussed.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cimentos Ósseos , Humanos , Polimetil Metacrilato , Falha de Prótese , Vácuo