Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
SICOT J ; 10: 25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38847649

RESUMO

BACKGROUND: Joint-preserving hip operations can help relieve pain and delay the need for long-term joint arthroplasty. Previous research has not identified procedures that can compromise outcomes following total hip arthroplasty (THA). This meta-analysis aims to evaluate the effect of joint-preserving hip operations on outcomes following subsequent THA. METHODS: MEDLINE, EMBASE and Scopus databases were searched from the date of inception until February 2024. All studies comparing outcomes following THA in individuals with (PS) and without prior surgery (NPS) of the femur or pelvis were included. Data on operative time, blood loss, intra- and post-operative complications, functional outcomes, and implant survivorship were extracted. RESULTS: 16 studies, comprising 2576 patients were included (PS = 939, NPS = 1637). The PS group was associated with significantly longer operative time [MD: 8.1, 95% CI: 4.6-11.6], significantly greater blood loss [MD: 167.8, 95% CI: 135.6-200.0], and a higher risk of intra-operative peri-prosthetic fracture [RR: 1.9, 95% CI: 1.2-3.0], specifically, with prior femoral osteotomy. There were no differences in terms of risks of dislocation [RR: 1.8, 95% CI: 1.0-3.2], implant loosening [RR: 1.0, 95% CI: 0.7-1.5], or revision surgery [RR: 1.3, 95% CI: 1.0-1.7] between the two groups. The PS group was associated with significantly poorer improvements in functional outcome [MD: -5.6, 95% CI: -7.6-(-3.5)], specifically, with prior acetabular osteotomy. Implant survivorship in the two groups was comparable after one year [HR: 1.9, 95% CI: 0.6-6.2] but significantly inferior in the PS group after five years [HR: 2.5, 95% CI: 1.4-4.7], specifically, with prior femoral osteotomy. CONCLUSION: Joint-preserving hip operations are associated with greater intra-operative challenges and complications. In subsequent joint arthroplasty, prior acetabular procedures affect functional outcomes while prior femoral procedures influence implant survivorship. Hip pain due to the morphological sequelae of pediatric hip pathology can be debilitating at a young age. Surgical decision-making at that time needs to consider the survivorship of a THA implanted at that young age against the consequences of hip preservation surgery on further THA.

2.
J Mech Behav Biomed Mater ; 138: 105573, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525874

RESUMO

Measurement of the properties of bone as a material can happen in various length scales in its hierarchical and composite structure. The aim of this study was to test the tissue level properties of clinically-relevant human bone samples which were collected from donors belonging to three groups: ageing donors who suffered no fractures (Control); untreated fracture patients (Fx-Untreated) and patient who experienced hip fracture despite being treated with bisphosphonates (Fx-BisTreated). Tissue level properties were assessed by (a) nanoindentation and (b) synchrotron tensile tests (STT) where strains were measured at the 'tissue', 'fibril' and 'mineral' levels by using simultaneous Wide-angle - (WAXD) and Small angle- X-ray diffraction (SAXD). The composition was analysed by thermogravimetric analysis and material level endo- and exo-thermic reactions by differential scanning calorimetry (TGA/DSC3+). Irrespective of treatment fracture donors exhibited significantly lower tissue, fibril and mineral strain at the micro and nanoscale respectively and had a higher mineral content than controls. In nanoindentation only nanohardness was significantly greater for Controls and Fx-BisTreated versus Fx-Untreated. The other nanoindentation parameters did not vary significantly across the three groups. There was a highly significant positive correlation (p < 0.001) between organic content and tissue level strain behaviour. Overall hip-fractures were associated with lower STT nanostrains and it was behaviour measured by STT which proved to be a more effective approach for predicting fracture risk because evidently it was able to demonstrate the mechanical deficit for the bone tissue of the donors who had experienced fractures.


Assuntos
Osso e Ossos , Fraturas do Quadril , Humanos , Envelhecimento , Difração de Raios X , Minerais , Densidade Óssea
3.
Artigo em Inglês | MEDLINE | ID: mdl-34841185

RESUMO

BACKGROUND: Power tools are an integral part of orthopaedic surgery but have the capacity to cause iatrogenic injury. With this systematic review, we aimed to investigate the prevalence of iatrogenic injury due to the use of power tools in orthopaedic surgery and to discuss the current methods that can be used to reduce injury. METHODS: We performed a systematic review of English-language studies related to power tools and iatrogenic injuries using a keyword search in MEDLINE, Embase, PubMed, and Scopus databases. Exclusion criteria included injuries related to cast-saw use, temperature-induced damage, and complications not clearly related to power-tool use. RESULTS: A total of 3,694 abstracts were retrieved, and 88 studies were included in the final analysis. Few studies and individual case reports looked directly at the prevalence of injury due to power tools. These included 2 studies looking at the frequency of vascular injury during femoral fracture fixation (0.49% and 0.2%), 2 studies investigating the frequency of vertebral artery injury during spinal surgery (0.5% and 0.08%), and 4 studies investigating vascular injury during total joint arthroplasty (1 study involving 138 vascular injuries in 124 patients, 2 studies noting 0.13% and 0.1% incidence, and 1 questionnaire sent electronically to surgeons). There are multiple methods for preventing damage during power-tool use. These include the use of robotics and simulation, specific drill settings, and real-time feedback techniques such as spectroscopy and electromyography. CONCLUSIONS: Power tools have the potential to cause iatrogenic injury to surrounding structures during orthopaedic surgery. Fortunately, the published literature suggests that the frequency of iatrogenic injury using orthopaedic power tools is low. There are multiple technologies available to reduce damage using power tools. In high-risk operations, the use of advanced technologies to reduce the chance of iatrogenic injury should be considered. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

4.
J Bone Joint Surg Am ; 103(13): e51, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34228669

RESUMO

BACKGROUND: We performed a systematic review of patient and public involvement in randomized controlled trials (RCTs) in the field of orthopaedic surgery. We assessed the prevalence, extent, and quality of patient and public involvement (PPI) in current academic orthopaedic practice. METHODS: A literature search of the Cochrane, MEDLINE, and Embase databases was performed; we identified RCTs that were published between 2013 and 2020 in the 10 orthopaedic surgery journals with the highest impact factors. Inclusion of studies was based on set criteria, and they were analyzed for their validity. The results were assessed for the rate and the quality of PPI reporting. The Wright and Foster guidelines and the GRIPP2-SF (Guidance for Reporting Involvement of Patients and the Public-2 short form) checklist were used to assess PPI reporting. This review was reported in line with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. RESULTS: An initial 2,107 results were identified. After the screening process, 475 full-text articles were identified and reviewed. Two papers that described PPI were included in this review. One paper used PPI to inform the research question, the choice of primary outcome, the oversight of the study schedule, and the dissemination of the results. The second article used PPI to design the study protocol. Both articles poorly reported the impact of PPI on the research. CONCLUSIONS: To our knowledge, this systematic review is the first to describe the prevalence, extent, and quality of PPI reporting in orthopaedic RCTs. Barriers to adequate PPI reporting are multifactorial and stem from a lack of systematic uptake of PPI guidelines and a lack of compulsory PPI reporting from publishing bodies. CLINICAL RELEVANCE: PPI can improve the quality of clinical trials by focusing on the clinical questions and outcomes that are most important to patients. This article assesses the prevalence of PPI reporting in orthopaedic RCTs.


Assuntos
Pesquisa Biomédica/estatística & dados numéricos , Participação da Comunidade/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Participação do Paciente/estatística & dados numéricos , Lista de Checagem , Guias como Assunto , Humanos , Publicações Periódicas como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Hip Int ; 30(1): 71-77, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30947562

RESUMO

INTRODUCTION: In arthroplasty surgery, positioning of the components must be accurate and reproducible to avoid complications. Conventional guides are often used to align a component, but they require surgical skill and experience, and are prone to error. To this end, a single-use, size-specific, nylon guide (single-use nylon guide) has been developed for the purpose of increasing the accuracy without adding extra cost to the operation. The effectiveness of this type of guide was evaluated in using a synthetic bone study. METHODS: A total of 66 synthetic femurs with the same osteoarthritic morphology were prepared. 3 surgeons participated in the experiments, and each surgeon created a drill hole for the femoral component by using the single-use nylon guide or a commercially-available, conventional, metal, neck-based guide (conventional guide). Anteversion, inclination, and insertion point acquired by the guide were compared between the guides, between surgeons, and to the computer-based plan. RESULTS: Anteversion acquired by the single-use nylon guide (6.7° [4.9-11.5°]) was significantly closer to the plan (14.6°) than that acquired by the conventional guide (4.3° [2.4-8.6°]) (p = 0.03). The insertion point was also significantly closer to the plan for the single-use nylon guide (3.8 mm ± 1.6 mm) than the conventional guide (5.7 mm ± 2.4 mm) (p < 0.001). No significant difference was found for the inclination (p = 0.76). CONCLUSION: A single-use, size-specific nylon guide was effective in acquiring a higher accuracy and precision in anteversion and insertion point than a conventional guide in this synthetic bone, hip resurfacing arthroplasty study. The use of single-use guides in other orthopaedic procedures should be explored.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Prótese de Quadril , Nylons , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Desenho de Prótese
6.
Appl Mater Today ; 15: 377-388, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31281871

RESUMO

An increasing volume of work supports utilising the mechanobiology of bone for bone ingrowth into a porous scaffold. However, typically during in vivo testing of implants, the mechanical properties of the bone being replaced are not quantified. Consequently there remains inconsistencies in the literature regarding 'optimum' pore size and porosity for bone ingrowth. It is also difficult to compare ingrowth results between studies and to translate in vivo animal testing to human subjects without understanding the mechanical environment. This study presents a clinically applicable approach to determining local bone mechanical properties and design of a scaffold with similar properties. The performance of the scaffold was investigated in vivo in an ovine model. The density, modulus and strength of trabecular bone from the medial femoral condyle from ovine bones was characterised and power-law relationships were established. A porous titanium scaffold, intended to maintain bone mechanical homeostasis, was additively manufactured and implanted into the medial femoral condyle of 6 ewes. The stiffness of the scaffold varied throughout the heterogeneous structure and matched the stiffness variation of bone at the surgical site. Bone ingrowth into the scaffold was 10.73±2.97% after 6 weeks. Fine woven bone, in the interior of the scaffold, and intense formations of more developed woven bone overlaid with lamellar bone at the implant periphery were observed. The workflow presented will allow future in vivo testing to test specific bone strains on bone ingrowth in response to a scaffold and allow for better translation from in vivo testing to commercial implants.

7.
Sci Rep ; 9(1): 7416, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-31092837

RESUMO

The cortex of the femoral neck is a key structural element of the human body, yet there is not a reliable metric for predicting the mechanical properties of the bone in this critical region. This study explored the use of a range of non-destructive metrics to measure femoral neck cortical bone stiffness at the millimetre length scale. A range of testing methods and imaging techniques were assessed for their ability to measure or predict the mechanical properties of cortical bone samples obtained from the femoral neck of hip replacement patients. Techniques that can potentially be applied in vivo to measure bone stiffness, including computed tomography (CT), bulk wave ultrasound (BWUS) and indentation, were compared against in vitro techniques, including compression testing, density measurements and resonant ultrasound spectroscopy. Porosity, as measured by micro-CT, correlated with femoral neck cortical bone's elastic modulus and ultimate compressive strength at the millimetre length scale. Large-tip spherical indentation also correlated with bone mechanical properties at this length scale but to a lesser extent. As the elastic mechanical properties of cortical bone correlated with porosity, we would recommend further development of technologies that can safely measure cortical porosity in vivo.


Assuntos
Osso Cortical/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Força Compressiva , Osso Cortical/fisiologia , Osso Cortical/ultraestrutura , Feminino , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiologia , Colo do Fêmur/ultraestrutura , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Tomografia Computadorizada por Raios X , Microtomografia por Raio-X
8.
J Orthop Res ; 37(5): 1123-1132, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30839114

RESUMO

In this computed tomography (CT) morphological study we describe the way the proximal femoral morphology differs with worsening degrees of developmental dysplasia of the hip (DDH) and describe gender differences in patients with DDH. Forty-nine male patients with DDH were matched with 49 females with DDH, using age and the Crowe classification of DDH severity. The femoral length, anteversion, neck-shaft angle, offset, neck length, canal-calcar ratio, canal flare index, lateral center-edge angle, alpha angle, pelvic tilt, and pelvic incidence were measured for each patient on their pre-operative CT scans, prior to total hip arthroplasty surgery. Femoral anteversion and neck length were 16° and 47 mm, 25°and 36 mm, 26° and 43 mm, and 44° and 36 mm, for Crowe I and III males and Crowe I and III females, respectively. The mean male anteversion was 22° (±14), compared to 30° (±15.5) in females (p = 0.02, Confidence Interval: 1.6-14.9). Gender differences in femoral length, neck length and offset lost significance when height-normalized and no other significant gender differences were found. In conclusion, femoral neck length reduces with increasing DDH severity, whilst anteversion tends to increase. Male patients with DDH have significantly less femoral anteversion, which has important implications for osteotomy and arthroplasty surgery in DDH. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Assuntos
Fêmur/patologia , Luxação Congênita de Quadril/patologia , Caracteres Sexuais , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Biomaterials ; 194: 183-194, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30611115

RESUMO

This study explored the regenerative osteogenic response in the distal femur of sheep using scaffolds having stiffness values within, and above and below, the range of trabecular bone apparent modulus. Scaffolds 3D-printed from stiff titanium and compliant polyamide were implanted into a cylindrical metaphyseal defect 15 × 15 mm. After six weeks, bone ingrowth varied between 7 and 21% of the scaffold pore volume and this was generally inversely proportional to scaffold stiffness. The individual reparative response considerably varied among the animals, which could be divided into weak and strong responders. Notably, bone regeneration specifically within the interior of the scaffold was inversely proportional to scaffold stiffness and was strain-driven in strongly-responding animals. Conversely, bone regeneration at the periphery of the defect was injury-driven and equal in all scaffolds and in all strongly- and weakly-responding animals. The observation of the strain-driven response in some, but not all, animals highlights that scaffold compliance is desirable for triggering host bone regeneration, but scaffold permanence is important for the load-bearing, structural role of the bone-replacing device. Indeed, scaffolds may benefit from being nonresorbable and mechanically reliable for those unforeseeable cases of weakly responding recipients.


Assuntos
Regeneração Óssea , Substitutos Ósseos/química , Fêmur/lesões , Alicerces Teciduais/química , Titânio/química , Animais , Feminino , Fêmur/fisiologia , Fêmur/ultraestrutura , Dureza , Nylons/química , Porosidade , Impressão Tridimensional , Ovinos
10.
PLoS One ; 13(7): e0200475, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30001364

RESUMO

OBJECTIVES: Bone material properties are a major determinant of bone health in older age, both in terms of fracture risk and implant fixation, in orthopaedics and dentistry. Bone is an anisotropic and hierarchical material so its measured material properties depend upon the scale of metric used. The scale used should reflect the clinical problem, whether it is fracture risk, a whole bone problem, or implant stability, at the millimetre-scale. Indentation, an engineering technique involving pressing a hard-tipped material into another material with a known force, may be able to assess bone stiffness at the millimetre-scale (the apparent elastic modulus). We aimed to investigate whether spherical-tip indentation could reliably measure the apparent elastic modulus of human cortical bone. MATERIALS AND METHODS: Cortical bone samples were retrieved from the femoral necks of nineteen patients undergoing total hip replacement surgery (10 females, 9 males, mean age: 69 years). The samples underwent indentation using a 1.5 mm diameter, ruby, spherical indenter tip, with sixty indentations per patient sample, across six locations on the bone surfaces, with ten repeated indentations at each of the six locations. The samples then underwent mechanical compression testing. The repeatability of indentation measurements of elastic modulus was assessed using the co-efficient of repeatability and the correlation between the bone elastic modulus measured by indentation and compression testing was analysed by least-squares regression. RESULTS: In total, 1140 indentations in total were performed. Indentation was found to be repeatable for indentations performed at the same locations on the bone samples with a mean co-efficient of repeatability of 0.4 GigaPascals (GPa), confidence interval (C.I): 0.33-0.42 GPa. There was variation in the indentation modulus results between different locations on the bone samples (mean co-efficient of repeatability: 3.1 GPa, C.I: 2.2-3.90 GPa). No clear correlation was observed between indentation and compression values of bone elastic modulus (r = 0.33, p = 0.17). The mean apparent elastic modulus obtained by spherical indentation was 9.9 GPa, the standard deviation for each indent cycle was 0.11 GPa, and the standard deviation between locations on the same sample was 1.01 GPa. The mean compression apparent elastic modulus was 4.42 GPa, standard deviation 1.02 GPa. DISCUSSION: Spherical-tip indentation was found to be a repeatable test for measuring the elastic modulus of human cortical bone, demonstrated by a low co-efficient of repeatability in this study. It could not, however, reliably predict cortical bone elastic modulus determined by platens compression testing in this study. This may be due to indentation only probing mechanical properties at the micro-scale while platens compression testing assesses millimetre length-scale properties. Improvements to the testing technique, including the use of a larger diameter spherical indenter tip, may improve the measurement of bone stiffness at the millimetre scale and should be investigated further.


Assuntos
Densidade Óssea , Osso Cortical/química , Cabeça do Fêmur/química , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Sci Rep ; 7: 43399, 2017 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-28262693

RESUMO

Osteoporosis is characterised by trabecular bone loss resulting from increased osteoclast activation and unbalanced coupling between resorption and formation, which induces a thinning of trabeculae and trabecular perforations. Bisphosphonates are the frontline therapy for osteoporosis, which act by reducing bone remodelling, and are thought to prevent perforations and maintain microstructure. However, bisphosphonates may oversuppress remodelling resulting in accumulation of microcracks. This paper aims to investigate the effect of bisphosphonate treatment on microstructure and mechanical strength. Assessment of microdamage within the trabecular bone core was performed using synchrotron X-ray micro-CT linked to image analysis software. Bone from bisphosphonate-treated fracture patients exhibited fewer perforations but more numerous and larger microcracks than both fracture and non-fracture controls. Furthermore, bisphosphonate-treated bone demonstrated reduced tensile strength and Young's Modulus. These findings suggest that bisphosphonate therapy is effective at reducing perforations but may also cause microcrack accumulation, leading to a loss of microstructural integrity and consequently, reduced mechanical strength.


Assuntos
Alendronato/uso terapêutico , Conservadores da Densidade Óssea/uso terapêutico , Osso e Ossos/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Osteoporose/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea/efeitos dos fármacos , Remodelação Óssea/efeitos dos fármacos , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/lesões , Estudos de Casos e Controles , Módulo de Elasticidade , Feminino , Fraturas Ósseas/patologia , Fraturas Ósseas/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Osteoporose/patologia , Síncrotrons , Resistência à Tração , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA