Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 49(5): 1462-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26530269

RESUMO

OBJECTIVES: Aortic valve replacement (AVR) using a bioprosthesis remains controversial for patients aged 50-65 years. This cohort study reports the very long-term outcomes of AVR using Carpentier-Edwards Perimount pericardial bioprosthesis in this age group. METHODS: From 1984 to 2008, 522 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 516 patients aged 50-65 years (mean age, 60 ± 4 years; 19% female). Multiple valve replacements were excluded fro m our cohort. Baseline demographic, perioperative and follow-up data were recorded prospectively. Mean follow-up was 9 ± 6 years, for a total of 4428 valve-years. Follow-up was complete for 97% of patients included. RESULTS: Operative mortality rate was 2%. One hundred and forty-six late deaths occurred for a linearized rate of 3%/valve-year. Actuarial survival rates averaged 73 ± 2, 59 ± 3 and 35 ± 5% after 10, 15 and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2%. Actuarial freedom from reoperation rates due to structural valve deterioration (SVD) at 10, 15 and 20 years was respectively of 91 ± 2, 76 ± 3 and 50 ± 6%. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 30 ± 3%. Expected valve durability was 19 years for this age group. Age was not a significant risk factor for SVD in this middle-aged population. CONCLUSIONS: In patients aged 50-65 years undergoing AVR with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 19 years. Age was not a significant risk factor for SVD within this age group. Patient selection and attention to timing of reintervention may be determinants of long-term outcomes.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Ann Thorac Surg ; 100(3): 853-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26187006

RESUMO

BACKGROUND: Aortic valve replacement using a bioprosthesis remains controversial for patients younger than 60 years because of missing data on long-term outcomes in this age group. METHODS: From 1984 to 2008, 383 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 373 patients 60 years or younger (mean age, 51.0 ± 9.2 years; 19% female). Multiple valve replacements were excluded from our cohort. Baseline clinical, perioperative, and follow-up data were recorded prospectively. The mean follow-up was 8.6 ± 5.9 years, for a total of 3,299 valve-years. Follow-up was complete for 95.3% of patients included. RESULTS: Operative mortality rate was 1.3%. Eighty-five late deaths occurred, for a linearized rate of 2.6%/valve-year. Actuarial survival rates averaged 78.1% ± 2.6%, 65.6% ± 3.5%, and 46.8% ± 6.0% after 10, 15, and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2.3%. Actuarial freedom from reoperation rates attributable to structural valve deterioration at 10, 15, and 20 years were, respectively, 88.3% ± 2.4%, 70.8% ± 4.1%, and 38.1% ± 5.6%. Competing risk analysis demonstrated an actual risk of explantation secondary to structural valve deterioration at 20 years of 41.6% ± 4.1%. Expected valve durability was 17.6 years for this age group. CONCLUSIONS: In selected patients 60 years or younger undergoing aortic valve replacement with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 17.6 years. Reoperation for structural valve deterioration was associated with a low risk of mortality.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Adolescente , Adulto , Fatores Etários , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA