Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Med Biol Eng Comput ; 54(12): 1949-1957, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27099155

RESUMO

Despite the technological improvement of radiologic, endoscopic and nuclear imaging, the accuracy of diagnostic procedures for tumors can be limited whenever a mass-forming lesion is identified. This is true also because bioptical sampling cannot be properly guided into the lesions so as to puncture neoplastic tissue and to avoid necrotic areas. Under these circumstances, invasive and expensive procedures are still required to obtain diagnosis which is mandatory to plan the most appropriate therapeutic strategy. In order to test if electrical impedance spectroscopy may be helpful in providing further evidence for cancer detection, resistivity measurements were taken on 22 mice, 11 wild-type and 11 sparc-/- (knock out for the protein SPARC: secreted protein acidic and rich in cysteine), bearing mammary carcinomas, by placing a needle-probe into tumor, peritumoral and contralateral healthy fat areas. Tumor resistivity was significantly lower than both peritumoral fat and contralateral fat tissues. Resistivity in sparc-/- mice was lower than wild-type animals. A significant frequency dependence of resistivity was present in tissues analyzed. We conclude that accurate measurements of resistivity may allow to discriminate between tissues with different pathological and/or structural characteristics. Therefore, resistivity measurements could be considered for in vivo detection and differential diagnosis of tumor masses.


Assuntos
Neoplasias Mamárias Experimentais/patologia , Osteonectina/deficiência , Animais , Modelos Animais de Doenças , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Camundongos Endogâmicos BALB C , Agulhas , Osteonectina/metabolismo , Ultrassom
2.
Respir Physiol Neurobiol ; 221: 35-40, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26555081

RESUMO

The aim of the study was to determine in human patients the effect of lung resection on lung compliance and on pleuro-pulmonary fluid balance. Pre and post-operative values of compliance were measured in anesthetized patients undergoing resection for lung cancer (N=11) through double-lumen bronchial intubation. Lung compliance was measured for 10-12 cm H2O increase in alveolar pressure from 5 cm H2O PEEP in control and repeated after resection. No air leak was assessed and pleural fluid was collected during hospital stay. A significant negative correlation (r(2)=0.68) was found between compliance at 10 min and resected mass. Based on the pre-operative estimated lung weight, the decrease in compliance following lung resection exceeded by 10-15% that expected from resected mass. Significant negative relationships were found by relating pleural fluid drainage flow to the remaining lung mass and to post-operative lung compliance. Following lung re-expansion, data suggest a causative relationship between the decrease in compliance and the perturbation in pleuro-pulmonary fluid balance.


Assuntos
Pulmão/cirurgia , Pleura/fisiopatologia , Mecânica Respiratória/fisiologia , Equilíbrio Hidroeletrolítico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Complacência Pulmonar , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Pleura/patologia , Respiração com Pressão Positiva , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA