BJOG ; 131(3): 267-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37522240

RESUMO

OBJECTIVE: To identify vaginal morphology and position factors associated with prolapse recurrence following vaginal surgery. DESIGN: Secondary analysis of magnetic resonance images (MRI) of the Defining Mechanisms of Anterior Vaginal Wall Descent cross-sectional study. SETTING: Eight clinical sites in the US Pelvic Floor Disorders Network. POPULATION OR SAMPLE: Women who underwent vaginal mesh hysteropexy (hysteropexy) with sacrospinous fixation or vaginal hysterectomy with uterosacral ligament suspension (hysterectomy) for uterovaginal prolapse between April 2013 and February 2015. METHODS: The MRI (rest, strain) obtained 30-42 months after surgery, or earlier for participants with recurrence who desired reoperation before 30 months, were analysed. MRI-based prolapse recurrence was defined as prolapse beyond the hymen at strain on MRI. Vaginal segmentations (at rest) were used to create three-dimensional models placed in a morphometry algorithm to quantify and compare vaginal morphology (angulation, dimensions) and position. MAIN OUTCOME MEASURES: Vaginal angulation (upper, lower and upper-lower vaginal angles in the sagittal and coronal plane), dimensions (length, maximum transverse width, surface area, volume) and position (apex, mid-vagina) at rest. RESULTS: Of the 82 women analysed, 12/41 (29%) in the hysteropexy group and 22/41 (54%) in the hysterectomy group had prolapse recurrence. After hysteropexy, women with recurrence had a more laterally deviated upper vagina (p = 0.02) at rest than women with successful surgery. After hysterectomy, women with recurrence had a more inferiorly (lower) positioned vaginal apex (p = 0.01) and mid-vagina (p = 0.01) at rest than women with successful surgery. CONCLUSIONS: Vaginal angulation and position were associated with prolapse recurrence and suggestive of vaginal support mechanisms related to surgical technique and potential unaddressed anatomical defects. Future prospective studies in women before and after prolapse surgery may distinguish these two factors.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Estudos Prospectivos , Estudos Transversais , Resultado do Tratamento , Procedimentos Cirúrgicos em Ginecologia/métodos , Vagina/diagnóstico por imagem , Vagina/cirurgia , Histerectomia Vaginal , Prolapso Uterino/cirurgia , Prolapso de Órgão Pélvico/cirurgia
2.
Int Urogynecol J ; 33(6): 1649-1657, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35394140

RESUMO

INTRODUCTION AND HYPOTHESIS: We present a 3D computational approach for automated clitoral measurements. We hypothesized that computationally derived measurements would be comparable and less variable than reported manual measures. METHODS: In this retrospective study, MRIs of 22 nulliparous women age 20-49 years with normal vaginal and clitoral anatomy were collected. Manual segmentations were performed to reconstruct 3D models of the whole clitoris (glans, body, crura, and bulbs) and vagina. The length, width, and volume of the clitoral structures and the distance between the vagina and clitoral structures were calculated. Computed clitoral morphometrics (length, width) were compared to median [range] values from a previously published cadaver study (N = 22) using the median test and Moses extreme reaction test. Calculated distances were compared to mean (± SD) reported by a 2D MRI study (N = 20) using independent t-test and Levene's test. RESULTS: Overall, computed clitoral morphometrics were similar to manual cadaver measurements, where the majority of length and width measures had ~1-2 mm difference and had less variability (smaller range). All calculated distances were significantly smaller and had smaller SDs than manual 2D MRI values, with two-fold differences in the means and SDs. Large variation was observed in clitoral volumetric measures in our cohort. CONCLUSIONS: The proposed 3D computational method improves the standardization and consistency of clitoral measurements compared to traditional manual approaches. The use of this approach in radiographic studies will give better insight into how clitoral anatomy relates to sexual function and how both are impacted by gynecologic surgery, where outcomes can assist treatment planning.


Assuntos
Clitóris , Imageamento por Ressonância Magnética , Adulto , Cadáver , Clitóris/anatomia & histologia , Clitóris/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Vagina , Adulto Jovem
3.
Comput Methods Programs Biomed ; 208: 106175, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34082373

RESUMO

BACKGROUND AND OBJECTIVE: Pelvic organ prolapse (POP), the herniation of the pelvic organs toward the vaginal opening, is a common pelvic floor disorder (PFD) whose etiology is poorly understood. Traditional methods for evaluating POP are often constrained to external vaginal examination, limited to 2D, or have poor reproducibility. We propose a reliable 3D anatomic coordinate system for standardized 3D assessment of pelvic anatomy using magnetic resonance imaging (MRI). METHODS: The novel 3D anatomic reference system is based on six bony landmarks of the pelvis manually identified in MRI: the ischial spines and the superior and inferior pubic points of the left and right pubic symphysis. The origin of this system is defined as the midpoint of the ischial spines. The reproducibility and applicability of the pelvic coordinate system were evaluated by (1) implementing it in a new method to quantify vaginal position and axis (angulation) in 3D space from MRI segmentations of the vagina and (2) computing the intraclass correlation (ICC) on coordinate system and vaginal measures. The MRI analysis was performed by four non-medically trained observers on five pelvic MRI datasets on approximately five separate occasions. RESULTS: Overall, all bony landmarks had excellent intra-observer reliability and inter-observer reliability (ICC>0.90); intra-observer reliability was moderate-to-good among the vaginal position parameters (0.5

Assuntos
Prolapso de Órgão Pélvico , Feminino , Humanos , Imageamento por Ressonância Magnética , Pelve , Reprodutibilidade dos Testes , Vagina/diagnóstico por imagem
4.
Am J Obstet Gynecol ; 225(5): 506.e1-506.e28, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34087229

RESUMO

BACKGROUND: Prolapse recurrence after transvaginal surgical repair is common; however, its mechanisms are ill-defined. A thorough understanding of how and why prolapse repairs fail is needed to address their high rate of anatomic recurrence and to develop novel therapies to overcome defined deficiencies. OBJECTIVE: This study aimed to identify mechanisms and contributors of anatomic recurrence after vaginal hysterectomy with uterosacral ligament suspension (native tissue repair) vs transvaginal mesh (VM) hysteropexy surgery for uterovaginal prolapse. STUDY DESIGN: This multicenter study was conducted in a subset of participants in a randomized clinical trial by the Eunice Kennedy Shriver National Institute of Child Health and Human Development Pelvic Floor Disorders Network. Overall, 94 women with uterovaginal prolapse treated via native tissue repair (n=48) or VM hysteropexy (n=46) underwent pelvic magnetic resonance imaging at rest, maximal strain, and poststrain rest (recovery) 30 to 42 months after surgery. Participants who desired reoperation before 30 to 42 months were imaged earlier to assess the impact of the index surgery. Using a novel 3-dimensional pelvic coordinate system, coregistered midsagittal images were obtained to assess study outcomes. Magnetic resonance imaging-based anatomic recurrence (failure) was defined as prolapse beyond the hymen. The primary outcome was the mechanism of failure (apical descent vs anterior vaginal wall elongation), including the frequency and site of failure. Secondary outcomes included displacement of the vaginal apex and perineal body and change in the length of the anterior wall, posterior wall, vaginal perimeter, and introitus of the vagina from rest to strain and rest to recovery. Group differences in the mechanism, frequency, and site of failure were assessed using the Fisher exact tests, and secondary outcomes were compared using Wilcoxon rank-sum tests. RESULTS: Of the 88 participants analyzed, 37 (42%) had recurrent prolapse (VM hysteropexy, 13 of 45 [29%]; native tissue repair, 24 of 43 [56%]). The most common site of failure was the anterior compartment (VM hysteropexy, 38%; native tissue repair, 92%). The primary mechanism of recurrence was apical descent (VM hysteropexy, 85%; native tissue repair, 67%). From rest to strain, failures (vs successes) had greater inferior displacement of the vaginal apex (difference, -12 mm; 95% confidence interval, -19 to -6) and perineal body (difference, -7 mm; 95% confidence interval, -11 to -4) and elongation of the anterior vaginal wall (difference, 12 mm; 95% confidence interval, 8-16) and vaginal introitus (difference, 11 mm; 95% confidence interval, 7-15). CONCLUSION: The primary mechanism of prolapse recurrence following vaginal hysterectomy with uterosacral ligament suspension or VM hysteropexy was apical descent. In addition, greater inferior descent of the vaginal apex and perineal body, lengthening of the anterior vaginal wall, and increased size of the vaginal introitus with strain were associated with anatomic failure. Further studies are needed to provide additional insight into the mechanism by which these factors contribute to anatomic failure.


Assuntos
Imageamento por Ressonância Magnética , Pelve/diagnóstico por imagem , Falha de Tratamento , Prolapso Uterino/diagnóstico por imagem , Prolapso Uterino/cirurgia , Idoso , Feminino , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Humanos , Histerectomia Vaginal/efeitos adversos , Imageamento Tridimensional , Pessoa de Meia-Idade , Recidiva
5.
Int Urogynecol J ; 32(4): 809-818, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32870340

RESUMO

INTRODUCTION AND HYPOTHESIS: The protocol and analysis methods for the Defining Mechanisms of Anterior Vaginal Wall Descent (DEMAND) study are presented. DEMAND was designed to identify mechanisms and contributors of prolapse recurrence after two transvaginal apical suspension procedures for uterovaginal prolapse. METHODS: DEMAND is a supplementary cohort study of a clinical trial in which women with uterovaginal prolapse randomized to (1) vaginal hysterectomy with uterosacral ligament suspension or (2) vaginal mesh hysteropexy underwent pelvic magnetic resonance imaging (MRI) at 30-42 months post-surgery. Standardized protocols have been developed to systematize MRI examinations across multiple sites and to improve reliability of MRI measurements. Anatomical failure, based on MRI, is defined as prolapse beyond the hymen. Anatomic measures from co-registered rest, maximal strain, and post-strain rest (recovery) sequences are obtained from the "true mid-sagittal" plane defined by a 3D pelvic coordinate system. The primary outcome is the mechanism of failure (apical descent versus anterior vaginal wall elongation). Secondary outcomes include displacement of the vaginal apex and perineal body and elongation of the anterior wall, posterior wall, perimeter, and introitus of the vagina between (1) rest and strain and (2) rest and recovery. RESULTS: Recruitment and MRI trials of 94 participants were completed by May 2018. CONCLUSIONS: Methods papers which detail studies designed to evaluate anatomic outcomes of prolapse surgeries are few. We describe a systematic, standardized approach to define and quantitatively assess mechanisms of anatomic failure following prolapse repair. This study will provide a better understanding of how apical prolapse repairs fail anatomically.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Estudos de Coortes , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Prolapso Uterino/diagnóstico por imagem , Prolapso Uterino/cirurgia , Vagina/diagnóstico por imagem , Vagina/cirurgia
6.
Comput Methods Biomech Biomed Engin ; 24(2): 122-130, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32885671

RESUMO

Obstructed defecation (OD) is common and may be related to compromised pelvic floor integrity. Magnetic resonance (MR) defecography and statistical shape modeling were used to define pelvic floor shape variations, hypothesizing that State (rest vs peak evacuation) and Group (control vs case) would significantly influence shape. 16 women underwent MR defecography (9 cases vs 7 controls). Midsagittal, 2D pelvic floors were segmented and aligned by corresponding points. Principal component scores were compared using a Two-Way Mixed MANOVA. Three modes described differences between State (p < 0.001) and Group (p = 0.023). The pelvic floor shape differed significantly between women with and without OD and during evacuation.


Assuntos
Constipação Intestinal/patologia , Defecação , Modelos Estatísticos , Diafragma da Pelve/patologia , Análise de Variância , Defecografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Análise de Componente Principal
SELEÇÃO DE REFERÊNCIAS