Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Future Cardiol ; 20(1): 21-25, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223918

RESUMO

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Assuntos
Bloqueio Atrioventricular , Defeitos dos Septos Cardíacos , Marca-Passo Artificial , Humanos , Ventrículos do Coração/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Bloqueio Atrioventricular/terapia , Átrios do Coração/diagnóstico por imagem
2.
Int J Surg Case Rep ; 105: 108012, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36966716

RESUMO

INTRODUCTION: With the spread of the use of implantable loop recorders (ILRs) by cardiologists for outpatient cardiac monitoring, intrathoracic migration represents a rare but possible complication occurring after the placement of these devices. Very few cases of ILRs intrathoracic migration into the pleural cavity have been reported, followed in even fewer cases by surgical removal of the devices, but in none re-implantation was performed. PRESENTATION OF CASE: We report the first case of a patient with a new generation ILR accidentally migrated into the postero-inferior costophrenic recess of the left pleural cavity, successfully removed by uniportal video-assisted thoracic surgery (VATS) and submitted to re-implantation of a new ILR in the same operating session. DISCUSSION: To reduce the risk of ILRs intrathoracic displacement, the insertion technique must be performed in the most suitable part of the chest wall, with the correct incision and angle of penetration, by an expert operator. When migrated into the pleural cavity, surgical removal should be performed to avoid the onset of early and late complications. A mini-invasive surgical approach by uniportal VATS could be considered as the first choice, ensuring a favourable patient outcome. Re-implantation of a new ILR can be safely performed in the same operating session. CONCLUSION: In case of intrathoracic migration of ILRs, early removal by mini-invasive approach is recommended as well as concomitant re-implantation. Beyond periodic monitoring of ILRs by cardiologists, strict radiological follow-up with chest X-ray is advisable after implantation, in order to early identify any abnormalities and correctly manage them.

3.
World J Clin Cases ; 9(25): 7472-7477, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34616814

RESUMO

BACKGROUND: Laminopathies are rare diseases, whose cardiac manifestations are heterogeneous and, especially in their initial stage, similar to those of more common conditions, such as ischemic heart disease. Early diagnosis is essential, as these conditions can first manifest themselves with sudden cardiac death. Electrical complications usually appear before structural complications; therefore, it is important to take into consideration these rare genetic disorders for the differential diagnosis of brady and tachyarrhythmias, even when left ventricle systolic function is still preserved. CASE SUMMARY: A 60-year-old man, without history of previous disorders, presented in September 2019 to the emergency department because of the onset of syncope associated with hypotension. The patient was diagnosed with a high-grade atrioventricular block. A dual chamber pacemaker was implanted, but after the onset of a sustained ventricular tachycardia during physical exertion, a drug eluting stent was implanted on an intermediate stenosis on the left anterior descending artery, which had previously been considered non-haemodynamically significant. During the follow-up, the treating cardiologist, suspicious of the overall clinical picture, recommended a genetic test for the diagnosis of cardiomyopathies, which tested positive for a pathogenetic mutation of the lamin A/C gene. While awaiting the result of the genetic test and, later, the pacemaker to be upgraded to a biventricular defibrillator, a remote monitoring device was given to the patient in order to minimize in-person clinical evaluations during the coronavirus disease 2019-related lockdown. CONCLUSION: This case aims to raise awareness of the cardiological manifestations of laminopathies, which can be dangerously misdiagnosed as other, more common conditions.

4.
Hip Int ; 30(2_suppl): 42-51, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33267695

RESUMO

INTRODUCTION: There is limited knowledge of the long-term results of metal-on-metal total hip arthroplasty (MoM THA), particularly concerning adverse local tissue reaction (ALTR), Co/Cr ions level and revision rate. Even if MoM bearing surfaces are no longer used, long-term data could help in defining the course and best management for these patients. The purpose of this study is to investigate the clinical outcomes, describe radiological findings including CT metal artefact reduction algorithm for orthopaedic implants (O-MAR) and MRI multi acquisition variable resonance image combination (MAVRIC) in 36-mm MoM THA. METHODS: In this long-term prospective study, 46 consecutive patients with primary MoM THA (mono- or bilateral) were enrolled between 2004 and 2005. Pinnacle acetabular cup, Summit cementless stem with 36-mm metal head and Ultamet CoCr alloy liner (Depuy Inc.) were implanted, in the same centre by the same senior surgeon. Patients were reviewed at 5-, 10- and 15-years, including Co/Cr levels and standard radiographs at every follow-up, whilst the 15-year follow-up included hip sonography, MRI MAVRIC and CT O-MAR. RESULTS: At 15 years, the overall survival rate of the implants (both stems and cups) was 83% (30/36). Revisions were performed in 9% (4/46) because of ALTR, 2% (1/46) septic loosening and 2% periprosthetic fracture. Both Cr and Co concentration increased over time, even though remaining at low level risk at 15 years: Co from 0.11 (+/- 0.18) to 4.29 (+/- 3.26) and Cr from 0.38 (+/- 0.32) to 1.37 (+/- 1.15). Functional scores in non-revised patients showed good to excellent results in more than 90%. Engh-score correlated with time from surgery (p = 0.017) and with sonographic, CT and RM findings (p < 0.05). Concordance has been found between CT and MRI findings (sign-rank test, p = 0.241; Intraclass Correlation Coefficients 0.987); however, no specific MRI or CT lesion patterns could be recognised among symptomatic and non-symptomatic patients. DISCUSSION: The long-term rate of ALTR after 36-mm MoM THA was comparable with previous studies; a regular follow-up for those implants is mandatory. During follow-up Co-Cr levels increased over time and radiography was a suitable screening technique; the Engh score in particular, proved to be a reliable assessment tool. CT O-MAR and MRI with MAVRIC protocols may add valuable data in clinical practice, although MRI is significantly more efficient than CT in the identification of ALTR lesions, peri-articular effusion and in the evaluation of soft tissues.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Seguimentos , Humanos , Laboratórios , Imageamento por Ressonância Magnética , Próteses Articulares Metal-Metal/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA