Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Arch Orthop Trauma Surg ; 142(12): 3965-3973, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35083520

RESUMO

INTRODUCTION: Condylar constrained knee arthroplasties (CCKAs) and rotating hinge knee arthroplasties (RHKAs) achieved good outcomes in complex primary total knee arthroplasties (TKAs); however, long-term comparative studies are few. Using an arthroplasty registry, we sought to assess and compare in CCKAs and RHKAs: (1) the intra-operative rates of complications, (2) the survival rates, (3) the reasons for revision, and (4) the adjusted hazard ratios for failure. MATERIALS AND METHODS: 1432 constrained implants in primary TKAs performed for non-oncological indications were included: 703 RHKAs, 729 CCKAs. The two groups were comparable regarding age and gender. Kaplan-Meier curves were used to compare survival rates, multivariate analyses to assess the hazard ratios for failures. RESULTS: The mean follow-up was 4.1 years (range 0-16.3) for CCKAs and 6.8 years (0-18.1) for RHKAs. The intra/peri-operative complications were similar in both the cohorts, with similar rates of femoral and tibial fractures. 10-year implant survival rates were similar in both the cohorts (91.9%, CI 95% 89.2-93.9% in RHKAs; 93.4%, CI 95% 90.3-95.6% in CCKAs). Periprosthetic infection was the most common reason for revision in the two cohorts, followed by aseptic loosening. Breakage occurred in 3 RHKAs (0.4%). CCKAs and RHKAs had a similar distribution of revision causes. Males aged less than 60 had significantly more failures, regardless the constraint degree. Unstemmed CCKAs significantly failed more than RHKAs and stemmed CCKAs. CONCLUSIONS: Both modern CCKAs and RHKAs are viable long-term solutions in complex primary TKAs. More failures should be expected in males aged less than 60. LEVEL OF EVIDENCE: IV, Therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Masculino , Humanos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Desenho de Prótese , Reoperação/efeitos adversos , Falha de Prótese , Resultado do Tratamento , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Seguimentos
3.
J Exp Orthop ; 8(1): 112, 2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-34860310

RESUMO

PURPOSE: The aim is to compare the results of isolated hip arthroscopy in patients with borderline dysplasia with Lateral center edge angle (LCEA) between 18° and 25° with a control group of patients with normal LCEA (> 25°). METHODS: Fifty hip arthroscopies performed in 45 patients were retrospectively evaluated. Exclusion criteria were: age > 40, hip arthritis > grade 2 according to Tonnis classification, femoral head avascular necrosis, pediatric's orthopaedics conditions and true dysplasia with LCEA < 18°.Two groups were identified: group A with 15 hips with LCEA between 25° and 18° and Group control B made of 35 hips with LCEA > 25°. RESULTS: The groups were homogeneous for demography and pre-operative WOMAC and HOOS. Osteoplasty for CAM were performed in 100% of patients in both groups, only in 12 hips (34.4%) in group B we had both femoral and acetabular osteoplasty. Labral repair was performed in 86% of patients in group A, in 60% of patients in group B, capsular plication in 93% of group A, in 5% of case of group B. WOMAC and HOOS statically significant improved in both groups at final follow-up (24 months). No cases in both groups required conversion to total hip arthroplasty. Clinical outcomes of study group were comparable to the control group. CONCLUSION: Even if the present small series is not conclusive, we suggest isolated arthroscopic management of patients with FAI and LCEA between 18° and 25°, but capsular plication and careful labral management are strongly recommended. LEVEL OF EVIDENCE: Level IV.

4.
Skeletal Radiol ; 50(9): 1775-1779, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33532940

RESUMO

OBJECTIVE: Stem anteversion in total hip arthroplasty (THA) has been measured using two different distal references, the posterior condyle (PC) or the transepicondylar axis (TEA). The reliability, the difference in value between these two techniques, and the possible confounding factors are scarcely known. Aims of this work were to assess (1) the intraclass correlation and the difference between the two measurement techniques and (2) the possible influence of condylar dysmorphisms on the anteversion value discrepancy. MATERIALS AND METHODS: A consecutive series of post-THA CT scans were selected, excluding hip dysplasia, end-stage knee osteoarthritis, and replaced knees. Using a surgical planning software, stem anteversion was measured using the PC or the TEA reference. The intraclass reliability was assessed. The anteroposterior femoral condyle diameters were measured: the difference and the ratio were measured and correlated with the stem anteversion values. RESULTS: 91 CT scans were included. Inter/intra-observer TEA measurements were more reliable than PC. The intraclass correlation between PC and TEA anteversion measurements was good, 0.954 (CI 95% 0.922-0965). The mean difference between PC and TEA anteversion was 5.27 ± 2.41°. The difference and the ratio between the two anteroposterior condyle diameters did not influence the anteversion difference (respectively, p 0.797 and p 0.901). CONCLUSIONS: TEA and PC demonstrated to achieve a good correlation, not dependent from the condyle morphology. However, the difference between the two measurements (5°) can severely influence the combined anteversion (10-20%): due to clinical applicability and better inter/intra-observer agreement, TEA should be preferred for measuring stem anteversion.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Osteoartrite do Joelho/cirurgia , Reprodutibilidade dos Testes
5.
Med Princ Pract ; 30(1): 29-36, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32756066

RESUMO

Ceramic-on-ceramic (COC) total hip arthroplasties (THAs) with large heads (>36 mm) were introduced to reduce dislocation rates and restore the hip anatomy as closely as possible to the native one. To date, the literature is scarce and fragmented; a review is desirable to point out the outcomes and the possible specific complications (noise, groin pain, and taperosis). A systematic review about large-diameter COC THAs was conducted according to the PRISMA guidelines. The PubMed and Cochrane databases were searched using the terms "large", "big", "head", "hip", and "ceramic." The methodological quality of the papers was assessed using the MINORS (Methodological Index for Nonrandomized Studies) score. Seven papers (level of evidence: 5 case series and 2 case-control studies) met the inclusion criteria. Clinical outcomes were excellent in >90% of the patients. Groin pain was reported in only 1 article (7%). Radiological outcomes were positive. Minimal revision rates (<2%) were reported at short- to mid-term follow-ups. Dislocation rates were usually <1%. No bearing surfaces failed. No case of trunnionitis was reported. Noise occurred in up to 30% of the patients, mostly squeaking. The noise did not influence clinical outcomes or patients' satisfaction. Noise was inconstantly associated with component positioning, younger age, high articular excursions, and larger sizes. Large-diameter heads in COC THAs (≥40 mm) showed promising clinical and radiological outcomes with minimal revision rates. Noise is a cause of concern and should be carefully evaluated at longer follow-ups and in larger, prospective, and specifically designed case series.


Assuntos
Artroplastia de Quadril/métodos , Cerâmica/química , Prótese de Quadril , Desenho de Prótese/métodos , Fatores Etários , Humanos , Ruído , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Fatores Sexuais , Fatores Socioeconômicos
6.
Clin Lab ; 65(6)2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31232020

RESUMO

BACKGROUND: Ischemia-modified albumin (IMA) derives from naive albumin, modified in the binding region of bivalent ions, as cobalt and iron. The cobalt, released from some types of hip prosthesis seems to be metabolized differently in males and females but the iron ion is more prevalent than cobalt and is detectable in the healthy population. Our aim was to verify if there are any gender- and age-related differences in IMA concentrations and if IMA correlates with cobalt and iron-related proteins. METHODS: IMA, albumin, iron, ferritin, transferrin, and cobalt were measured in 50 men and 50 women divided into two age/fertility-homogeneous groups. RESULTS: Men < 45-years-old showed a statistically significant lower IMA concentration than men ≥ 45 and fertile and menopausal women. Considering all the population studied, IMA does not seem to be correlated with age and is distributed differently by gender; also, Co distribution was different between males and females. CONCLUSIONS: IMA did not correlate with cobalt, iron, ferritin, and transferrin in any group, except for fertile women where IMA presented a statistically significant correlation with serum iron values. Minor expression of IMA in young males together with the results obtained on serum iron in fertile females, could explain the higher accumulation of circulating Co in women compared to men and their different cobalt metabolism.


Assuntos
Biomarcadores/sangue , Cobalto/sangue , Ferro/sangue , Adulto , Estudos de Casos e Controles , Feminino , Ferritinas/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Albumina Sérica/metabolismo , Albumina Sérica Humana , Fatores Sexuais , Transferrina/metabolismo
7.
Chir Organi Mov ; 91(3): 133-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18493831

RESUMO

Femoral neck fractures are progressively increasing, due to higher survival rates, particularly among the female population. The gamma nail was created to treat intertrochanteric fracture types 31-A1, 31-A2 and 31-A3 and in some cases basicervical fractures of type 31-B2-1. Complications can be classified as intraoperative and postoperative. The intraoperative might be related to the nail's introduction site, lag and distal locking screw positions. Postoperative complications depend mostly on an incorrect surgical technique, which can lead to an inaccurate nail position and consequent implant failure. We rarely observe failures caused by severe bone osteoporosis.


Assuntos
Pinos Ortopédicos/efeitos adversos , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA