Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
BMC Ophthalmol ; 22(1): 132, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35331177

RESUMO

BACKGROUND: Full-thickness idiopathic macular hole (IMH) usually causes serious visual deformities and visual acuity loss. Pseudophakic cystic macular edema, also known as Irvine-Gass syndrome, is another entity that causes visual disturbances, and occurs mainly after cataract extraction. We present a case report of a patient that was diagnosed with a full-thickness macular hole that spontaneously closed after the resolution of an Irvine-Gass syndrome, which occurred after an uneventful cataract extraction. CASE PRESENTATION: A 75 years-old female presented with the complaints of decreased visual acuity and color contrast sensitivity on both eyes (OU) and central visual field deformations on her left eye (LE). She was diagnosed with a full-thickness IMH on her LE, and cataract on OU. After an uneventful cataract extraction via phacoemulsification, she developed an Irvine-Gass syndrome at her LE, which was treated topically. The IMH closed spontaneously after the resolution of the Irvine-Gass syndrome, and the patient is being followed with no further complaints. CONCLUSION: The exact mechanism for spontaneous closure of full-thickness idiopathic macular holes is still not completely understood. In this case, we hypothesize that the coalesced intraretinal cysts caused by the Irvine-Gass syndrome formed a bridge-like structure connecting the inner walls of the macular hole, thus connecting the remnants of the Muller cells which enabled the full recovery of the normal foveal structure.


Assuntos
Edema Macular , Facoemulsificação , Perfurações Retinianas , Idoso , Feminino , Fóvea Central , Humanos , Edema Macular/diagnóstico , Facoemulsificação/efeitos adversos , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/etiologia , Perfurações Retinianas/cirurgia , Tomografia de Coerência Óptica
2.
Clinics (Sao Paulo) ; 76: e2913, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34287482

RESUMO

OBJECTIVES: To test conjunctival swabs from patients with laboratory-confirmed severe forms of coronavirus disease 2019 (COVID-19) for the presence of SARS-CoV-2 on real-time reverse-transcription polymerase chain reaction (rRT-PCR). METHODS: Fifty conjunctival swabs were collected from 50 in-patients with laboratory-confirmed severe forms of COVID-19 at the largest teaching hospital and referral center in Brazil (HCFMUSP, São Paulo, SP). The samples were tested for SARS-CoV-2 on rRT-PCR with the primers and probes described in the CDC protocol which amplify the region of the nucleocapsid N gene (2019_nCoV_N1 and 2019_nCoV_N2) of SARS-CoV-2 RNA and compared with naso/oropharyngeal swabs collected within 24 hours of the conjunctival swabs. RESULTS: Five conjunctival samples (10%) tested positive (amplification of the N1 and N2 primer/probe sets) while two conjunctival samples (4%) yielded inconclusive results (amplification of the N1 primer/probe set only). The naso/oropharyngeal swabs were positive for SARS-CoV-2 on rRT-PCR in 34 patients (68%), negative in 14 (28%) and inconclusive in 2 (4%). The 5 patients with positive conjunctival swabs had positive (n=2), negative (n=2) or inconclusive (n=1) naso/oropharyngeal swabs on rRT-PCR. Patients with negative or inconclusive naso/oropharyngeal swabs had the diagnosis of COVID-19 confirmed by previous positive rRT-PCR results or by serology. CONCLUSION: This is the first study to present conjunctival swab rRT-PCR results for SARS-CoV-2 in a Brazilian population. In our sample of 50 patients with severe forms of COVID-19, 10% had positive conjunctival swabs, most of which were correlated with positive naso/oropharyngeal rRT-PCR results.


Assuntos
COVID-19 , Brasil , Humanos , RNA Viral , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Reversa , SARS-CoV-2
3.
Clinics ; 76: e2913, 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1286071

RESUMO

OBJECTIVES: To test conjunctival swabs from patients with laboratory-confirmed severe forms of coronavirus disease 2019 (COVID-19) for the presence of SARS-CoV-2 on real-time reverse-transcription polymerase chain reaction (rRT-PCR). METHODS: Fifty conjunctival swabs were collected from 50 in-patients with laboratory-confirmed severe forms of COVID-19 at the largest teaching hospital and referral center in Brazil (HCFMUSP, São Paulo, SP). The samples were tested for SARS-CoV-2 on rRT-PCR with the primers and probes described in the CDC protocol which amplify the region of the nucleocapsid N gene (2019_nCoV_N1 and 2019_nCoV_N2) of SARS-CoV-2 RNA and compared with naso/oropharyngeal swabs collected within 24 hours of the conjunctival swabs. RESULTS: Five conjunctival samples (10%) tested positive (amplification of the N1 and N2 primer/probe sets) while two conjunctival samples (4%) yielded inconclusive results (amplification of the N1 primer/probe set only). The naso/oropharyngeal swabs were positive for SARS-CoV-2 on rRT-PCR in 34 patients (68%), negative in 14 (28%) and inconclusive in 2 (4%). The 5 patients with positive conjunctival swabs had positive (n=2), negative (n=2) or inconclusive (n=1) naso/oropharyngeal swabs on rRT-PCR. Patients with negative or inconclusive naso/oropharyngeal swabs had the diagnosis of COVID-19 confirmed by previous positive rRT-PCR results or by serology. CONCLUSION: This is the first study to present conjunctival swab rRT-PCR results for SARS-CoV-2 in a Brazilian population. In our sample of 50 patients with severe forms of COVID-19, 10% had positive conjunctival swabs, most of which were correlated with positive naso/oropharyngeal rRT-PCR results.


Assuntos
Humanos , COVID-19 , Brasil , RNA Viral , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Reversa , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA